• Title/Summary/Keyword: rotating magnetic field

Search Result 152, Processing Time 0.024 seconds

An Open Gradient Magnetic Separator Assembled Using NdFeB Magnets for a Use of Fine Particles Remover

  • Park, Eon-Byung;Choi, Seung-Duck;Yang, Choong-Jin;Lee, Won-Sub
    • Journal of Magnetics
    • /
    • v.3 no.3
    • /
    • pp.69-73
    • /
    • 1998
  • A drum type magnetic separator was designed and optimized by computer simulation. The separator consisted of rotating outer shell of drum, magnetic flux generator drum which was assembled with numbers of disk type magnet holders, and drum axis around which the magnet holders were fixed. NdFeB magnet blocks were inserted into the disks, and the disks were assembled layer by layer along the drum axis. Magnetic circuits of the separator were simulated on the basis of highest magnetic strength, least cost, and high yield of separation by using a Vector Field S/W employing the Opera-2D program. The separator proved a separation yield of 95% in removing fine iron-base particles, and installed at Hot Rolling Mill of Pohang Iron & Steel Co. In Korea.

  • PDF

Tiny Magnetic Robot Mechanism and Manipulation for Stent Transportation and Installation

  • Yu, Chang-Ho;Kim, Sung Hoon
    • Journal of Magnetics
    • /
    • v.22 no.1
    • /
    • pp.162-167
    • /
    • 2017
  • Magnetic spiral-type microrobots, which are driven by a rotating magnetic field, have excellent locomotive abilities, whereas their medical applications are limited in the terms of function, such as the ability to drill in blood vessels. In this study, we propose a new robot with superior applications using a magnetic spiral-type machine. The proposed robot can be applied to stent transportation and installation without a catheter. In particular, the robot can be applied to the cardiovascular system, cerebrovascular disease, and nonvascular stent applications depending on the robot size. The robot consists of two independent spiral-type machines and four magnets in total. We controlled directions of thrust force of the two machines, respectively, for active locomotion with a task. We conducted a preliminary validation of the proposed robot for stent transportation and installation through experimental analyses.

Multi-axial Force Characteristics of Radial Electrodynamic Wheel (래디알 동전기 휠의 다축력 특성)

  • Jung, Kwangsuk
    • Journal of Institute of Convergence Technology
    • /
    • v.7 no.2
    • /
    • pp.1-5
    • /
    • 2017
  • The rotating electrodynamic wheel over a conductive plate produces thrust force as well as normal force. Specially, separating the conductive plate and spacing apart each part, the lateral stability of the rotating wheel is guaranteed due to the restoring force into neutral position. In this paper, the force characteristics of the electrodynamic wheel rotating over the conductive plate is analyzed using the finite element tool. First, the dominant parameters are identified considering the geometric configuration and the operating condition. And the sensitivity for the parameter deviation is quantified for the high force density. The above topology can be applied as an actuating principle for inter-city train as well as contact-free transfer device.

The Analysis of Temperature Characteristics of a Superconducting Power Supply Due to the Eddy Current (와전류에 의한 초전도 전원장치의 온도특성 해석에 관한 연구)

  • O, Yun-Sang;Bae, Joon-Han;Song, Myung-Kon;Ji, Chang-Sub;Kim, Ho-Min;Ko, Tae-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.175-177
    • /
    • 1996
  • This paper is studied on the numerical analysis of temperature distribution on the Nb-foil due to the eddy current under operating a superconducting power supply. The increase of rotating speed and magnetic flux above critical magnetic field lead to the temperature rising in the normal spot, the heat was distributed in the region of 30% distance from the center of the normal spot, but the most of the heat was transferred to LHe. Under operation of the sc power supply, the increase of rotation speed has the more influence on the temperature rising than that of magnetic flux. we can conclude that the totaling speed of normal spot is the main design consideration of the sc power supply, and get the optimal value of rotating speed.

  • PDF

Characterization and Detection of a Free-falling State of a Mobile HDD Using the Electromechanical Analysis in a Rotating Spindle System (스핀들 회전축계의 기전 연성 해석을 이용한 모바일 HDD의 자유 낙하 특성 및 감지에 관한 연구)

  • Park, Sang-Jin;Jang, Gun-Hee;Kim, Cheol-Soon;Han, Jae-Hyuk
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.1 s.106
    • /
    • pp.12-18
    • /
    • 2006
  • This research investigates the electromechanical characteristics of a spindle motor in a free-falling mobile hard disk drive before unexpected shock. Electromechanical simulation includes a time-stepping finite element analysis of the magnetic field in a speed controlled brushless DC motor and dynamic analysis of the stationary and rotating part linked by the fluid dynamic bearing under the free-falling condition. Analysis results show that the dynamic characteristics of the rotating spindle system during free-falling state have an effect on the relative motion between the stationary and rotating part of HDD. It results from the variation of reaction force in the bearing area due to the gravity force exerted on the rotating part of HDD, and the free-falling condition can be detected by observing the signal of the spindle motor and disk-head interface without using an accelerometer.

Characterization and Detection of a Free-Falling State of a mobile HDD Using Electromechanical Analysis in Rotating Spindle System (스핀들 회전축계의 기전 연성 해석을 이용한 모바일 HDD의 자유 낙하 특성 및 감지에 관한 연구)

  • Park, Sang-Jin;Jang, Gun-Hee;Kim, Cheol-Soon;Han, Jae-Hyuk
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.324-329
    • /
    • 2005
  • This research investigates the electromechanical characteristics of a spindle motor in a free-falling mobile hard disk drive before unexpected shock. Electromechanical simulation includes a time-stepping finite element analysis of the magnetic field in a speed controlled brushless DC motor and dynamic analysis of the stationary and rotating part linked by fluid dynamic bearing under the free-failing condition. Analysis results show that the dynamic characteristics of the rotating spindle system during free-falling state have an effect on the relative motion between the stationary and rotating part of HDD. It results from the variation of reaction force in the bearing area due to the gravely force exerted on the rotating part of HDD, and the free-failing condition can be detected by observing the signal of the spindle motor and disk-head interface without using the accelerometer.

  • PDF

Optical Analysis for the Estimation of Whole Blood Coagulation Time with Magnetic Particles (자성 철 가루를 이용한 혈액 응고시간 측정법의 광학적 해석)

  • Lee, Jaehyun;Choi, Hyoungsoon;Jang, Dongwoo;Nahm, Kie B.
    • Korean Journal of Optics and Photonics
    • /
    • v.24 no.6
    • /
    • pp.338-341
    • /
    • 2013
  • Prothrombin Time (PT) is used as a measure of blood coagulation time. An optical analysis of the signal generating mechanism is described here for the reflection-type arrangement. Thromboplastin added into serum or whole blood initiates the coagulation process. We added a sufficient amount of magnetic particles into the sample before adding thromboplastin and subjected the mixture to a rotating magnetic field. The laser light gets reflected in a periodically modulated fashion with respect to the magnetic field rotation. Analysis of this decaying modulation could produce a reasonable coagulation time. We also introduce a simulation model to explain the signal generating mechanism using LightTools.$^{TM}$

A Study on the Numerical Analysis of Magnetic Flux Density by a Solenoid for MIAB Welding (MIAB용접에서 코일에 의한 자속밀도 분포의 수치적 해석에 관한 연구)

  • Choe, Dong-Hyeok;Kim, Jae-Ung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.12
    • /
    • pp.73-81
    • /
    • 2001
  • The MIAB welding uses a rotating arc as its heat source and is known as an efficient method fur pipe butt welding. The arc is rotated around the weld line by the electro-magnetic force resulting from the interaction of arc current and magnetic field. The electro-magnetic force is affected by magnetic flux density, arc current, and arc length. Especially, the magnetic flux density is an important factor on arc rotation and weld quality. This paper presents a 2D finite element model for the analysis of magnetic flux density in the actual welding conditions. The magnetic flux density is mainly dependent on gap between two pipes, the position of coil from gap center, exciting current, and relative permeability. Thus, the relations between magnetic flux density and main factors were investigated through experiment and analysis. Experiments were performed for the steel pipes(48.1mm O.D and 2.0mm thickness). The analysis results of magnetic flux density reveal that it increases with increasing exciting current, increasing relative permeability, decreasing distance from gap center to coil, and decreasing gap size. It is considered that the results of this study can be used as important data on the design of coil system and MIAB welding system.

  • PDF

A Study on Active Ion Transport Technology to Improve Water Electrolysis System Performance (수전해 시스템 성능 향상을 위한 능동 이온수송 기술 연구)

  • HYEON-JUNG KIM;HAO GUO;SANG-YOUNG KIM
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.34 no.2
    • /
    • pp.132-140
    • /
    • 2023
  • In this study, rotary magnet holder (RMH) was manufactured to analyze the ion transport effect according to the rotating magnetic field for the hydrogen production efficiency by alkaline water electrolyte. In the experiment, the voltage signal according to the magnet arrangement inside the RMH, the rotation speed, and the rotation time was measured using the voltage measurement module. As a result of the voltage signal measurement experiment, the average potential difference increased as the rotation speed of the RMH increased. Through the results of the voltage signal measurement experiment, the most efficient magnet arrangement (case 2) was applied to the RMH to conduct a water electrolysis experiment. A 20% NaOH aqueous solution was filled in the electrolytic cell, and a direct current 2 V constant voltage was applied to measure the current value according to the RMH rotation to compare the hydrogen generation amount. When rotating at 100 RPM, the hydrogen production efficiency increased by 8.06% compared to when not rotating. Considering the area exceeding +25 mA, which was not measured at the beginning of the experiment, an increase in hydrogen production of about 10% or more can be expected.

Dynamic characteristics analysis of the magnetic actuator brake system (MASS) for emergency a car (비상 제동기능을 지닌 전자력 브레이크 시스템(MABS)에 대한 제안 및 동작특성해석)

  • Kang, Jong-Ho;Kim, Tae-Young;Choi, Sang-Min;Jung, Hyun-Kyo
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.68-70
    • /
    • 2006
  • This paper formulates the principle of the magnetic actuator break system (MASS) for emergency situation driving a car. When the exciting break system of a car is broken, MASS will be able to stop the car by the electric system. MASS controls the rotating wheel to slow down gradually while holding and laying the wheel down several ten times per second. We present the magnetic field and dynamic behavior analyses for the magnetic actuator break system using finite element method (FEM) associated with parameter, for calculating the displacement of the moving parts and the supplying current.

  • PDF