• Title/Summary/Keyword: rod-coil

Search Result 54, Processing Time 0.029 seconds

Performance Test of Search Coil Sensors with Different Core Types

  • Hyeonji Kang;Ho Jin;Yunho Jang;Seungmin Lee;Hyeonhu Park;Juhyeong Kim;Wooin Jo
    • Journal of Astronomy and Space Sciences
    • /
    • v.41 no.3
    • /
    • pp.139-148
    • /
    • 2024
  • A search coil magnetometer (SCM) is a common equipment to observe energy transmission and vibrations in space physics, enabling measurements across a wide frequency range of up to tens of kilohertz. This study proposes the designs of a magnetic core that allows a low-mass sensor and improves its performance: a rod core, sheet-stacked core, and rolling-sheet core. Subsequently, the performance of each sensor was investigated. The sheet-stacked core using the cobalt-based alloy exhibited the highest sensitivity, although it exhibited instability beyond 20 kHz. In contrast, the rod and rolling-sheet core sensors demonstrated stability in the magnetic field measurements (10 Hz-40 kHz). Moreover, the noise equivalent magnetic induction (NEMI) of the rod- and rolling-sheet core sensors were 0.014 pT Hz-1/2 and 0.012 pT Hz-1/2 at 1 kHz, respectively. The rolling-sheet core with high relative permeability achieved a mass reduction of over three times that of the rod core while exhibiting sufficient sensitivity.

Raman Spectroscopic Characterization of a Rod-Coil Liquid Crystalline Oligomer-LiCF₃SO₃ Complex

  • 유수창;한근옥;김동희;오남근;이명수;고석범;조인호
    • Bulletin of the Korean Chemical Society
    • /
    • v.17 no.11
    • /
    • pp.1004-1009
    • /
    • 1996
  • The interactions between a rod-coil liquid crystalline oligomer, ethyl 4-[4'-oxy-4-biphenylcarbonyloxy]-4'-biphenylcarboxylate with poly(ethylene oxide) (DP=12) (12-4) and LiCF3SO3 have been characterized by using Raman spectroscopy. Band assignments were made comparing the spectrum of 12-4 with those of the poly(ethylene glycol) monomethyl ether(PEGME) (Mw=550) and the ethyl-4'-hydroxybiphenyl-4-carboxylate (EHBPC), which are the coil and mesogen analogues, respectively. Analyzing characteristic bands of the 12-4-salt complex, we have found that the bands belonging to the coil and mesogenic units are changed in both intensities and frequencies. The spectral changes were interpreted from the viewpoint of the complexation between 12-4 and the Li+ ion. However, the possibility that the spectral changes in the mesogenic unit are not due to the complexation with the Li+ ion, but due to the conformational changes by the intercalation of nondissociated LiCF3SO3, is not ruled out.

Synthesis and Characterization of Poly(alkyl $\alpha$, L-glutamate-co-ethylene oxide)

  • Kim, Gunwoo;Kim, Jin-Yeol;Daewon Sohn;Lee, Youngil
    • Macromolecular Research
    • /
    • v.10 no.1
    • /
    • pp.49-52
    • /
    • 2002
  • Rod-coil amphiphilic block copolymers, PALG-PEOs, poly(alkyl $\alpha$, L-glutamate-co-ethylene oxide)s, were successfully synthesized in three steps: 1) esterification of L-glutamic acid, 2) synthesis of ${\gamma}$-alkyl L-gultamate N-carboxyanhydride, and 3) polymerization of NCA monomers. These molecules form polymeric micelles with the hydrophobic core and hydrophilic corona in aqueous solution, which were characterized by light scattering and static fluorescence measurement.

A Study on the Development of Low Frequency Electronic Ignition Trans for Large Combustors (대형연소기에 적용되는 저주파 전자식 점화 트랜스 개발에 관한 연구)

  • Lee, Ho-kyun;Park, Jung-cheul
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.4
    • /
    • pp.223-229
    • /
    • 2022
  • In this paper, the ignition trans used in boilers was studied. Regardless of the change in the ignition rod length and the ignition rod gap, the output frequency was measured between 59.5 and 61.3 Hz, and it was found that the low frequency circuit operated normally. When the ignition rod gap changed by 2 to 10 mm, the ignition rod length was measured from 2.8A to 3.45A at 30cm. The ignition rod length was measured from 9.37 A to 14.5 A at 500 cm and from 13.2 A to 32.6 A at 1000 cm. As the ignition rod length and the ignition rod gap increased, the current increased. As a result of measuring the secondary coil output voltage. The ignition rod length was measured from AC 0.84 kV to AC 1.75 kV at 30 cm, AC 1.17 kV to AC 1.944 at 500 cm, and AC 1.4 kV to AC 7.18 kV at 1000 cm. As the ignition rod length and the ignition rod gap increased, the output voltage of the secondary coil also increased. As a result of measuring the output voltage of the ignition trans, the ignition rod length was measured from DC 1.11 kV to DC 1.57 kV at 30cm, DC 2.49 kV to DC 3.72 kV at 500cm, and DC 3.78 kV to DC 9.42 kV at 1000cm, and the power voltage increased as the ignition rod length and interval increased.

The utilities of U-shape EM sensor in stress monitoring

  • Wang, Guodun;Wang, Ming L.
    • Structural Engineering and Mechanics
    • /
    • v.17 no.3_4
    • /
    • pp.291-302
    • /
    • 2004
  • In this paper, load monitoring technologies using U-shape Magnetoelastic (EM or ME) sensors have been exploited systemically for the first time. The steel rod to be tested is the Japan 7 mm piano steel rod. The load dependence of the magnetic properties of the piano steel rod was manifested. Two experimental designs of U-shape magnetoelastic sensors were introduced, one with double pick-up concentric coils wound on the rod to be tested, the other with pick-up coil on one yoke foot. The former design is used to derive the correlation of the relative permeability with elastic tension, while the latter is aimed to reflect the stress induced magnetic flux variation along the magnetic circuit. Magnetostatic simulations provide interpretations for the yoke foot sensing technology. Tests with double pick-up coils indicate that under proper working points (primary voltages), the relative permeability varies linearly with the axial load for the Japan 7 mm piano steel rod. Tests with pick-up coil on the yoke foot show that the integrated sensing voltage changes quadratically with the load, and error is more acceptable when the working point is high enough.

Simulation of magnetostrictive Terfenol-D rod dynamics using a coupled FE-BEM

  • Jarng, Soon-Suck
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.298-307
    • /
    • 1999
  • This paper describes the application of the coupled FE-BEM (finite element-boundary element method) for the numerical harmonic analysis of the linear dynamic behaviour of a magnetostrictive Terfenol-D rod in water. The magnetostrictive rod is three-dimensionally simulated to transduce applied electric current in a helical coil around the rod to mechanical displacement. The theoretical derivation of the magnetostrictive matrix equation is described in detail. The steady-state resonance response of the displacement is shown. In addition, the directivity pattern and the radiation impedance are also shown.

  • PDF

High Precision Solenoid Type Nuclear Reactor Control Rod Position Indicator (고정밀도 솔레노이드 방식의 원자로 제어봉 위치지시기)

  • Baek, Min-Ho;Hong, Hoon-Bin;Park, Hee-June
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.11
    • /
    • pp.1848-1853
    • /
    • 2016
  • Control Rod Position Indicator in nuclear reactor vessel has developed for small reactor in Korea. Because of severe environment in reactor vessel, target of this study is to develop the suitable position indicator. In this study, solenoid type position indicator made of Mineral Insulated Cable(MI Cable) was introduced to adapt in severe environment. And inductance of the solenoid was used to indicate the rod position for high precision. But problem of this concept is that a linear slope of inductance is changed by temperature effect. To resolve this problem, two sensing coils were introduced for temperature compensation. A role of the sensing coil is to make reference linear equation about certain temperature. To confirm this concept, also, inductance of solenoid and sensing coils were measured at room and high temperature (${\sim}300^{\circ}C$). The results of measurement show that the position error of sensing coil between room and high temperature was about 2%. But it was identified that this error was resulted from insufficient test environment (temperature error between solenoid and sensing coils was about 2% at high temperature condition). Therefore, solenoid type position indicator shows that it is very suitable in reactor vessel as a high precision rod position indicator.

Simulation of tracking errors for non-circular cutting using voice coil motor (VCM을 이용한 비원형 형상 가공의 궤적 오차 시뮬레이션)

  • Hwang J.D.;Kwak Y.K.;Kim S.H.;Ahan J.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.57-58
    • /
    • 2006
  • A Simulation model is developed to minimize the path tracking errors when the non-circular cutting is done by a VCM(voice coil motor) driven tool. The relationship between PWM(Pulse Width Modulation) duty ratio and velocity of voice coil motor is theoretically derived from combining the circuit equation for the coils and the motion equation for the magnetic rod of the voice coil motor. The path tracking errors are showed differently according to the rotational speed, the number of segments and the control period in digital control. Given a required accuracy in the non-circular cutting, the optimal values for those parameters are determined based on the developed simulation model.

  • PDF

Synthesis and microphase-separated structures of rod-coil triblock polymers

  • Uchida, Satoshi;Tanimura, Kotaro;Ishizu, Koji
    • Proceedings of the Polymer Society of Korea Conference
    • /
    • 2006.10a
    • /
    • pp.326-326
    • /
    • 2006
  • The combination of living anionic and coordination polymerization techniques enabled to synthesize the polystyrene-b-polyisoprene-b-poly (butyl isocyanate) triblock polymers. Their microphase-separated structures were zig-zag structures for high ${\phi}_{PIC}$ samples, and hockey-puck structures were also observed. The phase diagram for PSt-b-PIp-b-PIC rod-coil polymers was different from that for PS-PBd-PMMA triblock polymers, and it was found that ${\phi}_{PIC}$ was the important factor to determine the microphase-separated structures.

  • PDF