• Title/Summary/Keyword: risk zone

Search Result 309, Processing Time 0.321 seconds

Establishment and Application of an Integrated Platform for Navigation Safety Information (항행안전정보 통합 플랫폼 구축 및 활용방안에 관한 연구)

  • Kim, Do-Hoon
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.26 no.2
    • /
    • pp.129-138
    • /
    • 2020
  • This study recognizes problems in the current system of providing navigation safety information (NSI), which is centered on merchant ships, to prevent maritime accidents of fishing boats and small vessels in coastal areas. The system proposed in this study is an effective method of providing NSI to support the safe navigation of small vessels such as fishing boats. First, the status and characteristics of recent maritime accidents were examined, and NSI service targets were identified. Second, the limitations of the current NSI system were determined, and measures were proposed to establish an NSI Integrated Platform (NSIP) that ensures the integration, accessibility, and usability of NSI for a substantial portion of the public. Third, to utilize the NSIP, various NSIs are applied as additional information for the electronic chart system used in the e-navigation ship terminals being developed in connection with the Korean e-navigation project. Functions that set the audiovisual alarm function to automatically operate when a ship enters a navigation risk zone is proposed. These functions are technically achieved by reviewing expert opinions of related organizations and professional producers. The results of this study suggest that NSI can be applied to small vessels such as fishing boats, through the Korean e-Navigation project, to prevent maritime accidents caused by the human error of navigators.

Appropriateness of Location of Nuclear Accident Evacuation Shelters based on Population Characteristics and Accessibility -The Case of Busan Gijang-gun, Geumjeong-gu and Haeundae-gu in Korea- (인구특성과 접근성을 고려한 방사능재난 대피시설 입지 적정성 분석 -부산광역시 기장군, 금정구, 해운대구를 대상으로-)

  • DONG, Ah-Hyeon;LEE, Sang-Hyeok;KANG, Jung-Eun
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.22 no.4
    • /
    • pp.131-145
    • /
    • 2019
  • Korea has set up a radiation emergency planning zone based on the 「Act on Physical Protection and Radiological Emergency」 to protect residents living near nuclear power plants in the event of nuclear disasters. Little research has been conducted on the appropriateness of existing nuclear evacuation facilities because of a general lack of interest in nuclear accidents. This research addresses this gap by analyzing the location adequacy of evacuation facilities in Busan's emergency protection planning area based on vulnerable populations and accessibility analyses. The Gijang-gun which has the greatest risk, shows that only 4.05% of the total urban area was included in the evacuation service area within 5 minutes while only 36.93% of Geumjeong-gu and 37.23% of Haeundae-gu were included in the evacuation-enabled area. In addition, evaluation facilities in the elderly population hotspots were lacking, and there was a wide gap between dongs within the same Gu. Thus, additional evacuation facilities need to be designated and installed considering the spatial equity between areas and safety of both the public and vulnerable populations.

Bacterial Community of Traditional Doenjang in Longevity Area and Antagonistic Effect against Bacillus cereus (장수지역 전통된장의 미생물 군집 및 바실러스 세레우스 길항 효과)

  • Jeon, Doo-Young;Yoon, Gi-Bok;Yoon, Yeon-Hee;Yang, Soo-In;Kim, Jung-Beom
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.45 no.7
    • /
    • pp.1035-1040
    • /
    • 2016
  • This study investigated the prevalence of foodborne pathogens and the bacterial community of traditional Doenjang collected from a longevity area in Korea as well as the antagonistic effect of traditional Doenjang isolates against Bacillus cereus to estimate the microbiological safety of traditional Doenjang. Aerobic bacteria showed $10^6{\sim}10^9CFU/g$, whereas coliform bacteria was not detected. Foodborne pathogens were not detected except B. cereus, which was detected in seven samples out of 10 Doenjang samples. A total of 327 isolates were identified from traditional Doenjang. The isolates consisted of Bacillus subtilis 155 (47.4%), Bacillus licheniformis 68 (20.8%), Bacillus amyloliquefaciens 46 (14.1%), and Bacillus pumilus 18 (5.5%). Antagonistic effect against B. cereus was detected in 20 (6.1%) of 327 isolates, which consisted of B. subtilis (12 strains), B. amyloliquefaciens (5 strains), and B. licheniformis (3 strains). The inhibitory zone for the antagonistic effect was 9.0~12.0 mm in diameter. Although a small amount of traditional Doenjang was tested in this study, these results indicated that the potential risk of B. cereus in traditional Doenjang is lower than generally presumed. It is necessary to monitor the antagonistic effect of traditional Doenjang isolates against B. cereus.

Seepage Behaviors on the Box Culvert Side of Enlarged Levee (하천 보축제체의 배수통문 구조물 측면부 침투 특성)

  • Yang, Hakyoung;Kim, Youngmuk
    • Journal of the Korean GEO-environmental Society
    • /
    • v.21 no.4
    • /
    • pp.19-30
    • /
    • 2020
  • This numerical study is to investigate the seepage characteristics of the side of the structure in the event of leakage from the structural connection part of the drainage structure installed through the enlarged levee, and to analyze the effect of piping on the stabilization of the levee by the lateral penetration behavior. To take into account lateral seepage behavior, 2D and 3D numerical analyses were performed on the same model, and the effect of lateral seepage was analyzed to assess the validity of the numerical analysis. As a result, when leakage occurs and a lateral seepage is considered with the gate located on the riverside land, the maximum pore water pressure near the leakage point of the structure has been reduced by half compared to the normal seepage state where no leakage occurred. Excessive variation in the pore pressure was shown at the lower part of the structure, especially if lateral seepage is not considered. As a water level rises to the high water level, it shows the hydraulic gradient was larger than the critical hydraulic gradient, which will be vulnerable to long-term piping. If a gate is located in the inland and side seepage is not considered, the effect of the seepage water such as hydraulic gradient and seepage velocity is underestimated compared with the case of considering side seepage. The maximum hydraulic gradient is relatively small when lateral seepage is neglected if a gate is located in the riverside land and there was might be a risk of piping or loss of material. In addition, the period exceeding the critical hydraulic gradient was interpreted as a short time zone. As a result, it is considered that the possibility of piping can be underestimated if side seepage is ignored.

Prevalence of Abnormal Cervical Cytology in HIV-Negative Women Participating in a Cervical Cancer Screening Program in Calmette Hospital, Cambodia

  • Hav, Monirath;Eav, Sokha;Heang, Nicole;Pich, Pintuna;Lim, Davy;Leang, Vitou;Korn, Aun;Lay, Sanine;Pluot, Michel;Kruy, Leangsim
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.7
    • /
    • pp.3101-3103
    • /
    • 2016
  • Background: According to the most recent estimation of GLOBOCAN, Cambodia has the highest incidence and mortality rate of cervical cancer in Southeast Asia. A screen-and-treat strategy using visual inspection with acetic acid (VIA test) and cryotherapy has been implemented in Cambodia's national cervical cancer screening program since 2013. However, where resources are available, cervical cytology with or without high-risk HPV DNA testing is the preferred screening method used in this country. Aim: This study aims to calculate the prevalence of abnormal cervical cytology and explain the possible factors contributing to a reduced quality of cervical cytology among women participating in a hospital-based cervical cancer screening program in Cambodia. Materials and Methods: A descriptive study was conducted using information from the cytology and pathology database in the Department of Pathology of Calmette Hospital between January 2012 and December 2015. Prevalence of abnormal cervical cytology, based on the Bethesda 2001 classification, was calculated. Data on the adequacy of cytological specimens were analyzed in order to explain the factors contributing to a reduced quality of cervical cytology interpretation. Results: Among 6,207 women who participated in the cervical cancer screening program at Calmette Hospital during 2012 and 2015, 388 (6.25%) had abnormal cytology, which could be classified into Atypical Squamous Cells of Undetermined Significance (92 cases; 1.48%), Atypical Squamous Cells - Cannot Exclude High-Grade Intraepithelial Lesion (13 cases; 0.21%), Atypical Glandular Cells (11 cases; 0.18%), Low-Grade Squamous Intraepithelial Lesion (221 cases; 3.56%), High-Grade Squamous Intraepithelial Lesion (26 cases; 0.42%), and Squamous Cell Carcinoma (25 cases; 0.40%). Unsatisfactory smears made up 12.2% of the total cases. The most frequently identified factor leading to unsatisfactory smears was the absence of cells from the transformation zone. Conclusions: The present study showed an overall prevalence of abnormal cervical cytology of 6.25%, which is comparable to that in many large population-based studies in the Asia Pacific region. Nevertheless, the remarkably high rate of unsatisfactory smears in this study justifies further improvement in specimen sampling among Cambodian gynecologists.

Impervious Surface as a Thematic Parameter of Analysis for Childhood Asthma Hospitalizations : Spatio-temporal Approaches (소아천식 유병율 분포의 분석변수로서 불투수면 : 시공간적 접근)

  • Um, Jung-Sup
    • Journal of the Korean association of regional geographers
    • /
    • v.16 no.6
    • /
    • pp.706-723
    • /
    • 2010
  • The impervious surface was frequently employed as a proxy of the total environmental burden in the urban area. The impervious surface was extracted from a satellite image and the GIS (Geographical Information System) database for childhood asthma hospitalizations was generated for a total of 62,136 children using the National Health Insurance database of South Korea. Children living in an impervious environment do result in almost twice as many hospitalizations (26.58%) for asthma, as compared to the sub-urban pervious living (15.82%). Furthermore, the risk zones with persistently high hospitalizations for three years were specifically identified over the impervious sub-district alone. The impervious zone showed a small inter-year variation of hospitalizations (r: 0.937) while the sub-urban pervious fringe was found to display a yearly variation(r: 0.371). The strong temporal autocorrelation means that the impervious areas have frequent long-lived hospitalizations for asthma, thus children living in impervious areas were likely to have had more chronic asthma attacks than those living in pervious areas. These experimental results indicate that an impervious surface as thematic parameter of analysis is a crucial explanatory variable for asthma hospitalizations and its longer persistence among children.

  • PDF

The Impact of Land Use Structure and Vector Habitat Conditions on the Incidence of Malaria-A Case Study in High-Incidence Areas (매개모기의 서식환경과 토지이용 구조가 말라리아 발생에 미치는 영향 - 말라리아 고위험지역을 대상으로)

  • Kim, Ju-Hye;Park, Sun-Yurp
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.16 no.3
    • /
    • pp.12-24
    • /
    • 2013
  • Eradication of endemic malaria was declared in mid 1980's in Korea, but the number of malaria cases has been oscillating for the past 10 years since the reemergence of the disease in early 1990's. The occurrence of malaria has been concentrated near the demilitarized zone(DMZ), and the regional characteristics of the disease are evident. Considering the spatial variations of malaria incidence across the high-risk areas, the hotspot of the disease, it seems that the occurrence of the disease is influenced by the natural and human environment in the region. Malaria is an infectious disease that is transmitted to humans by the bites of vector-mosquitoes carrying malaria parasites, and it depends on specific climatic and sociodemographic factors. Malaria transmission is highly climate-sensitive, and temperature is the most important component. In addition, human contacts with vector-mosquitoes and the distance between human residence and mosquito habitats are crucial conditions determining malaria incidence rates. The present study aimed to test a hypothesis that the spatial characteristics of malaria incidence depended on local climatic conditions, relative proportions of mosquito habitats, and the distance between mosquito habitats and human residence using meteorological and satellite-based land cover data.

A Study on Obtaining Feedback Function of Disaster Information Management using Information & Communication Technology (ICT기술을 이용한 방재정보 관리의 환류기능 확보에 관한 연구)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.1
    • /
    • pp.73-88
    • /
    • 2015
  • Due to the cases of recent global warming and unusual weather etc., large-scale natural disasters such as typhoons, floods, snow damage occur frequently across the continents such as Southeast Asia and North America, South America etc. and risks of earthquakes and tsunami are also increasing gradually in Korea which has been regarded as a safe zone and disaster types are also being diversified such as typhoons, floods, heat waves, heavy snow and damage scale is also enlarged. In addition, due to geographical characteristics or lack of infrastructure, disasters tended to occur intensively around a specific region or city in the past but disasters occur throughout the country in recent years so preparation for disaster prevention has emerged as an urgent challenge issue. Therefore, considering that the plan of obtaining the effective feedback function of disaster Information is very important in the proactive and software aspects for disaster reduction, this paper analyzed this three aspects of contents, procedural and contextual aspects and proposed the plan. First, in the content aspect, building disaster prevention information communication Infrastructure, building urban and regional disaster prevention system, obtaining concurrency and sharing of information and second, in the procedural aspect, active utilization of ICT(Information and Communication Technology) of the prevention stage, disaster prevention information collection and analysis reinforcement of the preparation stage, improvement of decision-making structure and field command system of the response stage, recovery system related information promotion of the recovery stage were proposed as alternatives and finally, in the contextual aspect, if disaster prevention information is effectively managed through maintenance of disaster prevention information related systems, obtaining domainality by disaster prevention work, improvement of the ability to judge the situation, obtaining comprehensive and feedback function etc, it is considered to significantly contribute to reducing natural disasters.

Evaluation of Extremely Low Frequency Magnetic Fields emission Level from High Voltage Transmission Lines (고압 송전선로에서 극저주파 자기장 영향평가 적용에 관한 연구)

  • Jung, Joon Sig;Choi, Sung Ho;Jeon, Hyung Jin;Kim, Yoon Shin;Hong, Seung Cheol
    • Journal of Environmental Impact Assessment
    • /
    • v.23 no.5
    • /
    • pp.353-363
    • /
    • 2014
  • The purpose of this study was to investigated the ELF-MF emission level of various environments such as 258 facilities near located to high voltage transmission lines and 120 high voltage transmission lines, 17 underground cable lines. In addition, ELF-MF reduction rate according to separation distance was calculated by using simulations. An appropriate separation distance showing below 4mG was at least 70m. In the case of the appropriate separation distance for 120 high voltage transmission lines, 154kV required 20m of separation distance and 345kV required 60m of separation distance. The simulation results showed that the appropriate separation distance showing below 4mG was 40m and 60m for overhead 154kV and 345kV respectively. To adjust the worst conditions considering the aspects of environmental impact assessment study and the electric power currents that will increase in the future, the appropriate minimum separation distance for HVTL is judged to be above 70m in this study. Thus, there is a need to establish the greenbelt or buffer zone within 70m so as to create an environment in which the receptors are not exposed and thereby eliminate the risk factors of ELF-MF against humans.

Applying a Two-channel Video Streaming Technology Front and Rear Vehicle Wireless Video Monitoring System (2채널 영상 스트리밍 기술을 적용한 차량용 전. 후방 무선 영상 모니터링 시스템)

  • Na, HeeSu;Won, YoungJin;Yoon, JungGeun;Lee, SangMin;Ahn, MyeongIl;Kim, DongHyun;Moon, JongHoon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.12
    • /
    • pp.210-216
    • /
    • 2014
  • In this paper, it was proposed to develop front and rear image monitoring system for vehicle that help a driver to cope with urgent situation about a dangerous element. When parking a vehicle, the risk factors to be formed by the dead zone can be resolved by using anterior and posterior cameras of the vehicle. In embedded system environment, a SoC(System on Chip) and two high-resolution CMOS (Complementary metal-oxide-semiconductor) image sensors were used to transfer two high-resolution image data through he TCP/ IP-based network. To transfer image data through he TCP/ IP-based network, the images received by two cameras were compressed by using H.264 and they were transmitted with wireless method(Wi-Fi) by using real-time transport protocol (Real-time Transport Protocol). Transmission loss, transmission delay and transmission limit were solved in wireless (Wi-Fi) environment and the bit-rate of two image data compressed by H.264 was adjusted. And the system for the optimal transmission in wireless (Wi-Fi) environment was materialized and experimented.