• Title/Summary/Keyword: risk level monitoring

Search Result 267, Processing Time 0.022 seconds

Risk Analysis for Protecting Personal Information in IoT Environments (사물인터넷(IoT) 환경에서의 개인정보 위험 분석 프레임워크)

  • Lee, Ae Ri;Kim, Beomsoo;Jang, Jaeyoung
    • Journal of Information Technology Services
    • /
    • v.15 no.4
    • /
    • pp.41-62
    • /
    • 2016
  • In Internet of Things (IoT) era, more diverse types of information are collected and the environment of information usage, distribution, and processing is changing. Recently, there have been a growing number of cases involving breach and infringement of personal information in IoT services, for examples, including data breach incidents of Web cam service or drone and hacking cases of smart connected car or individual monitoring service. With the evolution of IoT, concerns on personal information protection has become a crucial issue and thus the risk analysis and management method of personal information should be systematically prepared. This study shows risk factors in IoT regarding possible breach of personal information and infringement of privacy. We propose "a risk analysis framework of protecting personal information in IoT environments" consisting of asset (personal information-type and sensitivity) subject to risk, threats of infringement (device, network, and server points), and social impact caused from the privacy incident. To verify this proposed framework, we conducted risk analysis of IoT services (smart communication device, connected car, smart healthcare, smart home, and smart infra) using this framework. Based on the analysis results, we identified the level of risk to personal information in IoT services and suggested measures to protect personal information and appropriately use it.

Survey of Institutional Review Board Risk Level Classification of Clinical Trials Among Korean University Hospitals (임상시험심사위원회(Institutional Review Board)의 임상시험에 대한 위험평가 분류조사연구)

  • Lee, Sun Ju;Kang, Su Jin;Maeng, Chi Hoon;Shin, Yoo Jin;Yoo, Soyoung
    • The Journal of KAIRB
    • /
    • v.4 no.2
    • /
    • pp.36-41
    • /
    • 2022
  • Purpose: The purpose of this study is to evaluate how university hospital Institutional Review Boards (IRBs) in Korea classify risk when reviewing clinical trial protocols. Methods: IRB experts (IRB chairman, vice chairman, IRB administrator) in the university hospitals obtaining a Human research protection program (HRPP) or IRB accreditation in Korea were asked to fill out the Google Survey from September 1, 2020 to October 10, 2020. Result: Among the 23 responder hospitals, 8 were accredited by the American Association for Human Research Protection Program (AAHRPP) and 8 were accredited by the HRPP of Ministry of Food and Drug Safety (MFDS). Seven were accredited by Forum for Ethical Review Committees in Asia and the Western Pacific or Korea National Institution for Bioethics Policy. Thirteen of 23 hospitals (56.5%) had 4 levels (less than minimal, low, moderate, high risk), 4 hospitals had 3 levels (less than, slightly over, over than minimal risk), 1 hospital had 5 levels (4 levels plus required data safety monitoring board), and 1 hospital had 2 levels (less than, over than minimal risk) risk classification system. Thirteen of 23 hospitals (56.5%) had difficulty classifying the risk levels of research protocols. Fourteen hospitals (60.9%) responded that different standards among hospitals for risk level determination associated with clinical trials will affect the subject protection. Six hospitals (26.1%) responded that it will not. Three hospitals (13.0%) responded that it will affect the beginning of the clinical trial. To resolve differences in standards between hospitals, 14 hospitals (60.9%) responded that either the Korean Association of IRB or MFDS needs to provide a guideline for risk level determination in clinical trials: 5 hospitals (21.7%) responded education for IRB members and researchers is needed; 3 hospitals (13.0%) responded that difference among institutions needs to be acknowledged; and 1 hospital (4.3%) responded that there needs to be communication among IRB, investigator, and sponsor. Conclusion: After conducting a nationwide survey on how IRB in university hospital determines risk during review of clinical trials, it is reasonable to use 4-level risk classification (less than minimal, low, moderate, high risk); the most utilized method among hospitals. Moreover, personal information and conflict of interest associated with clinical trials have to be considered when reviewing clinical trial protocols.

  • PDF

Weld Quality Monitoring System Development Applying A design Optimization Approach Collaborating QFD and Risk Management Methods (품질 기능 전개법과 위험 부담 관리법을 조합한 설계 최적화 기법의 용접 품질 감시 시스템 개발 응용)

  • Son, Joong-Soo;Park, Young-Won
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.6 no.2
    • /
    • pp.207-216
    • /
    • 2000
  • This paper introduces an effective system design method to develop a customer oriented product using a design optimization process and to select a set of critical design paramenters,. The process results in the development of a successful product satisfying customer needs and reducing development risk. The proposed scheme adopted a five step QFD(Quality Function Deployment) in order to extract design parameters from customer needs and evaluated their priority using risk factors for extracted design parameters. In this process we determine critical design parameters and allocate them to subsystem designers. Subsequently design engineers develop and test the product based on these parameters. These design parameters capture the characteristics of customer needs in terms of performance cost and schedule in the process of QFD, The subsequent risk management task ensures the minimum risk approach in the presence of design parameter uncertainty. An application of this approach was demonstrated in the development of weld quality monitoring system. Dominant design parameters affect linearity characteristics of weld defect feature vectors. Therefore it simplifies the algorithm for adopting pattern classification of feature vectors and improves the accuracy of recognition rate of weld defect and the real time response of the defect detection in the performance. Additionally the development cost decreases by using DSP board for low speed because of reducing CPU's load adopting algorithm in classifying weld defects. It also reduces the cost by using the single sensor to measure weld defects. Furthermore the synergy effect derived from the critical design parameters improves the detection rate of weld defects by 15% when compared with the implementation using the non-critical design parameters. It also result in 30% saving in development cost./ The overall results are close to 95% customer level showing the effectiveness of the proposed development approach.

  • PDF

Microbial Risk Assessment and HACCP Plan for the Safe Production of Dry Aged Meat (안전한 건식 숙성육 제조를 위한 미생물 위해평가 및 HACCP 적용 방안)

  • Oh, Hyemin;Lee, Hyun Jung;Jo, Cheorun;Yoon, Yohan
    • Journal of the FoodService Safety
    • /
    • v.3 no.1
    • /
    • pp.8-18
    • /
    • 2022
  • Dry-aging is one of the traditional aging processes, especially for beef. This aging process is being popular, because it produces unique brown/roasted flavor and texture that consumers prefer. However, as it is exposed to outside without packaging food safety concerns have been raised. The objective of this study was to investigate the presence of total aerobic bacteria (TAB) and pathogenic bacteria in manufacturing environment and suggest the safety management plan for the production of dry-aged meat. Surface samples from 66 environmental and 6 beef carcass samples were collected. According to the monitoring results, the contamination levels of TAB were in the order of shelves (5.4±1.1 Log CFU/cm2), cotton gloves (2.9±0.2 Log CFU/cm2), and door knobs (2.8±0.4 Log CFU/cm2) in the dry-aging room. In the door knobs, the level of mold was higher than that of yeast. These results indicate that the mold spores may be cross-contaminated with environmental factors inside the aging room. The risk factors that may occur during the manufacturing process were presented and possibility of risk was determined. From the aspect of microbiology, aging and trimming steps were determined as the critical control points. The temperature of the aging room should be maintained below 10℃ and the humidity below 75-85%. Based on the monitoring and the risk assessment of the dry-aging process, we prepared the safety management plan for the production of dry-aged meat, and it should be useful in improving the food safety of dry-aged meat.

Aggregate Risk Assessment on Xylene and Ethylbenzene (자일렌과 에틸벤젠에 대한 매체통합위해성평가 연구)

  • Seo, Jung-Kwan;Kim, Taksoo;Kim, Pilje
    • Journal of Environmental Science International
    • /
    • v.22 no.2
    • /
    • pp.163-171
    • /
    • 2013
  • The aggregate risk assessment on xylene and ethylbenzene was carried out according to the guidance established newly in 2010 with the purpose of providing information for risk management. In human exposure assessment, the results indicated that lower ages were exposed more and that, in the interior space at home, the highest level of human exposure occurred via inhalation. At outdoor spaces, exposures via inhalation and drinking were less than 1%. In human health risk characterization, xylene showed HI(Hazard Index) < 1 in all ages. When reasonable maximum exposure(RME) was applied, HI for young children was 0.64. The HI of ethylbenzene was also below 1(0.02~0.04) in all ages, indicating no potential risk. From this study, it is considered that xylene need to be continous monitoring with interest because this substance may be more sensitive on young age group. In additon, to reduce the uncertainty of the risk assessment, the korean exposure factors on young age group such as infant, children had to be established as soon as possible.

A Study of Musculoskeletal Disorders at a Subway Train Repair Plant in Korea (국내 지하철 정비 사업장의 근골격계질환 실태조사에 관한 연구)

  • Kim, Cheol-Hong;Gwon, Yeong-Jun;Baek, Seung-Ryeol;Son, Gyeong-Il
    • Journal of the Ergonomics Society of Korea
    • /
    • v.23 no.3
    • /
    • pp.121-134
    • /
    • 2004
  • A research project was conducted to study work-related musculoskeletal disorders (MSDs) at subway train repair plant in Korea. The project was consisted of 4 main parts; education on the topics of MSDs for all workers, symptom survey, medical check-up, investigation of MSD risk factors. The result of symptom survey showed that 95.2% of the respondents complained pains on at least one part of the body. After cross-sectional analysis of various information and risk factors, 86.8% of respondents were considered as active health surveillance level 1 that require continuous monitoring on their symptoms and working conditions. And 57.1% of the respondents were considered as active health surveillance level 2 that needed medical check-ups for proper medical treatment. The analysis of occupational risk factors revealed that handling of heavy object (46.15%) and repeated awkward postures (46.15%) were two most contributing risk factors for the on-set of MSD at this work site followed by static strain (7.7%), and vibration and impact (3.8%). Medical examination was performed by an industrial medicine MD on 156 workers those considered as active health surveillance level 2. The result showed that 35 workers (20.7%) were considered as MSD patient group at severe level, and 68.6 workers (68.6%) were considered as moderate group and 18 workers (10.6%) were considered minor or normal group those have no symptom.

Development of Multi-Sensor based River Monitoring Technology for River Flood Risk surveillance (하천 홍수 위험 감시를 위한 다중센서 기반 하천 관측 기술 개발)

  • Jang, Bong-Joo;Jung, In Taek
    • Journal of Korea Multimedia Society
    • /
    • v.23 no.11
    • /
    • pp.1372-1382
    • /
    • 2020
  • This paper proposes a core technology for a micro river monitoring terminal device suitable for flood monitoring in small rivers and valleys. Our proposed device is basically equipped with a 77GHz radar, gyro and accelerometer sensors. To measure the flow velocity and water level, we proposed a signal processing technique that extracts pure water energy components from the observed Doppler velocity and reflection intensity from the radar. And to determine the stability of the river structure equipped with our device, we constantly monitor the displacement of the measured values of the gyro and accelerometer sensors. Experimental result verified that our method detects pure water energy in various river environments and distinguishes between flow velocity and water level well. And we verified that vibration and position change of structures can be determined through a gyro sensor. In future research, we will work to build a secure digital twin river network by lowering the cost of supplying RF-WAV devices. Also we expect our device to contribute to securing a preventive golden time in rivers.

The Development of an Automatic Aquaculture System -1. Using a model tank- (양어장 자동화 시스템의 개발 -1. 모형 수조를 중심으로-)

  • KANG Ho-Won;LEE Seong-Ho;KIM Je-Yoon;JEONG Seok-Kwon;KIM Sang-Bong
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.28 no.3
    • /
    • pp.294-300
    • /
    • 1995
  • In aquaculture industrial field, an automatic management and control system is needed to cope with the difficulties such as expensive wage, ripe age of management worker and risk according to the unexpected change of environmental conditions in the aquarium. This paper introduces an automatic aquarium monitoring and control system. The system is developed using PC single board computer. A PC can be connected to multi-single hoard computers, and the communication between PC and single board computers is based on RS-422/485 interfacing method. The physical data of pH, DO, temperature and water level etc. are real-timely treated in the single board computer though individual transducers, transfered to the main monitoring PC through RS-422/485 communication, and those data are graphically shown on the PC monitor. Furthermore, the environmental circumstance can be monitored through the image processing system, and the emergency system can be operated under the condition of environmental incident such as electric power stoppage, DO deficiency, pump shut down and low level water etc.

  • PDF

Management in the EPC Business for Overseas Power Plant Projects (해외 발전플랜트 EPC 사업의 리스크 분석 및 관리방안)

  • Park, Euiseung;Yoo, Hoseon;Lee, Jae-Heon
    • Plant Journal
    • /
    • v.7 no.3
    • /
    • pp.48-64
    • /
    • 2011
  • In this work, risks in EPC project for overseas power plant projects are analyzed and risk management methods are suggested to reduce cost and to shorten time. 79% of risks occurred in the engineering phase for S project located in South-East Asia. The impact scales of risks on major project objectives which are cost, time, scope, and quality are analyzed as 3.5, 3.8, 2.7, and 3.7, respectively. The level of impact scales is very similar to each other except the impact scale of scope. The risk management methods suggested in this study have to be applied at the appropriate time to manage risks effectively. After that, risks are managed continuously by monitoring.

  • PDF

Intensive Care Unit Nurses' Knowledge and Nursing Practices regarding Bedside Electrocardiograph Monitoring (중환자실 간호사들의 침상모니터 심전도 관찰 관련 지식 및 간호행위)

  • Kang, Jeong Hee;Suh, In Sun;Kim, Ji Young
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.20 no.1
    • /
    • pp.60-70
    • /
    • 2014
  • Purpose: Bedside electrocardiograph (ECG) monitoring is continuously used for assessing patients' cardiac status in intensive care units. However, it has not been explored whether it is used with proper knowledge and nursing practices; if not, its usage will be limited and the risk for compromised patient safety might be significant. This study, therefore, explored knowledge and nursing practices regarding bedside ECG monitoring in nurses working at intensive care units. Methods: Participants in this survey research were a convenience sample of 156 nurses from 25 intensive care units distributed in five hospitals with more than 1,000 beds each in Seoul, South Korea. Results: Participants showed limited and incorrect knowledge and nursing practices. Only 4 (2.6%) participants correctly answered to all electrode placement sites of RA, LA, LL, and V1. Lead II was the most frequently monitored unit regardless of the main purpose of ECG monitoring, and nursing practices to manage noisy signals did not include skin care at the top priorities. Conclusion: Educators and clinicians alike need to make an effort to ensure that a safe level of knowledge and practices for the monitoring is maintained in order to make sure that patient outcomes are not compromised.