DOI QR코드

DOI QR Code

Aggregate Risk Assessment on Xylene and Ethylbenzene

자일렌과 에틸벤젠에 대한 매체통합위해성평가 연구

  • Received : 2012.09.20
  • Accepted : 2013.01.28
  • Published : 2013.02.28

Abstract

The aggregate risk assessment on xylene and ethylbenzene was carried out according to the guidance established newly in 2010 with the purpose of providing information for risk management. In human exposure assessment, the results indicated that lower ages were exposed more and that, in the interior space at home, the highest level of human exposure occurred via inhalation. At outdoor spaces, exposures via inhalation and drinking were less than 1%. In human health risk characterization, xylene showed HI(Hazard Index) < 1 in all ages. When reasonable maximum exposure(RME) was applied, HI for young children was 0.64. The HI of ethylbenzene was also below 1(0.02~0.04) in all ages, indicating no potential risk. From this study, it is considered that xylene need to be continous monitoring with interest because this substance may be more sensitive on young age group. In additon, to reduce the uncertainty of the risk assessment, the korean exposure factors on young age group such as infant, children had to be established as soon as possible.

Keywords

References

  1. ATSDR, 2007, Toxicological profile for xylene.
  2. ATSDR, 2010, Toxicological profile for ethylbenzene.
  3. Back, S. O., Kim, Y. S., 1998, Characterization of air quality in various types of indoor environments in urban areas: focusing on homes, offices, and restaurants, J. KAPRA., 14(4), 343-360.
  4. Chung, M. H., Jung, S. M., Kim, M. Y., Kim, G. W., Park, J. C., 2007, A field survey of indoor air environment of schools, Korean journal of airconditioning and refregeration engineering., 19(12), 865-873.
  5. Daejeon metropolitan waterworks authority, 2009, Consumer confidence report.
  6. Ha, D. H., Pyun, M. K., Lee, B. W., Kim, J. H., Kim, S. T., 2008, A study on the concentration levels of VOCs at the underground parking lots in Daejeon, Journal of Korean society for indoor environment., 5(1), 1-11.
  7. Jang, J. H., Jo, S. N., Kim, S. Y., Kim, S. J., Jeong, H. G., 2007, Korean exposure factors handbook.
  8. Jeon, J. M., Jeong, M. H., Lee, H. S., Kang, B. W., 2010, Characteristics of indoor hazardous pollutants in classroom of schools, Journal of Korean society for indoor environment., 7(1), 47-61.
  9. Jo, W. K., Park, K. H., 1999, Commuter exposure to volatile organic compounds under different driving conditions, Atmos. Env., 33, 409-417. https://doi.org/10.1016/S1352-2310(98)00201-5
  10. Jung, S. W., Yang, W. H., Son, B. S., 2007, Health risk assessment by potential exposure of $NO_{2}$ an VOCs in apartments., Kor. J. Env. Hlth., 33(4), 242-249. https://doi.org/10.5668/JEHS.2007.33.4.242
  11. Kim, Y. D., 2007, Measurement of classroom air quality in large cities in summer, Journal of the Korean solar energy society., 27(1), 63-74.
  12. Kim, Y. H., Yang, W. H., Son, B. S., 2007, Estimation of total exposure to benzene, toluene and xylene by microenvironmental measurements for iron mill workers, Kor. J. Env. Hlth., 33(5), 359-364. https://doi.org/10.5668/JEHS.2007.33.5.359
  13. Koh, Y. J., Kim, S. D., Park, S. Y., Jang, S. K., 2009, Childrens' health risk assessment on indoor hazardous air pollutants of preschool facility, J. Env. Hlth. Sci., 35(2), 78-85.
  14. Lee, C.M., Kim, Y. S., No, Y. M., Kim, J. C., Jeon, H. J., LEE, S. D., 2004, Health risk assessment of exposure to indoor air pollutants in office building, J Korean Soc Occup Environ Hyg., 14(3), 251-263.
  15. Maroni, M., Seifert, B., Lindvall, T(Eds.)., 1995, Indoor Air Quality comprehensive reference book. Elsevier, Amsterdam.
  16. Ministry of Environment, 2005, A Survey of non regulated public and small scaled facilities(I).
  17. Ministry of Environment, 2006, A study on management plans of indoor air quality by transport.
  18. Ministry of Environment, 2010, The guideline of procedures and methods for risk assessment (Regulation No.415, Ministry of Environment).
  19. Ministry of Environment, 2011, Environmental health Master plans on environmetal health(2011-2020).
  20. NIER, 2006, Measurement-method establishment and characterization of indoor air quality in Daycare centers, publication No. 2006-47-829.
  21. NIER, 2007, Annual Report of Ambient Air Quality in Korea.
  22. NIER, 2008, Annual Report of Ambient Air Quality in Korea.
  23. NIER, 2009a, Annual Report of Ambient Air Quality in Korea.
  24. NIER, 2009b, A Study on Management of Major Indoor Air Pollutants by House Type in Korea(I): Indoor Air Pollution and Health Effects in Residential Apartment.
  25. NIER, 2010, A Study on Management of Major Indoor Air Pollutants by House Type in Korea(II): Indoor air pollutants and health effects in residential detached and multiplex/terraced house, publication No. 2010-34-1209.
  26. NIER, 2011, The principle and methods of exposure assessment for chemical risk assessment.
  27. Statistics Korea, 2009, Time-use survey, http://survey.go.kr/lifestyle.
  28. Seoul Metropolitan Government, 2009, Consumer Confidence Report.
  29. US EPA, 1989, Risk assessment guidance for superfund volume I-Human health evaluation manual(Part A)
  30. US EPA, 2008, Child-specific exposure factors handbook.
  31. US EPA, 2011a, Exposure Factors Handbook : 2011 edition.
  32. US EPA, 2011b, http://www.epa.gov/iris.
  33. VCCEP, 2005, Voluntary Children's Chemical Evaluation Program(VCCEP) Tier 1 Pilot Submission(Xylene category). American Chemistry Council Benzene, Toluene, Xylenes VCCEP Consortium.
  34. Waterworks Headquarters Incheon Metropolitan City, 2009, Consumer confidence report.