• Title/Summary/Keyword: risk exposure

Search Result 2,044, Processing Time 0.033 seconds

Effect of Burnout on Post-traumatic Stress Disorder Symptoms Among Firefighters in Korea: Data From the Firefighter Research on Enhancement of Safety & Health (FRESH)

  • Kim, Woojin;Bae, Munjoo;Chang, Sei-Jin;Yoon, Jin-Ha;Jeong, Da Yee;Hyun, Dae-Sung;Ryu, Hye-Yoon;Park, Ki-Soo;Kim, Mi-Ji;Kim, Changsoo
    • Journal of Preventive Medicine and Public Health
    • /
    • v.52 no.6
    • /
    • pp.345-354
    • /
    • 2019
  • Objectives: It is well-known that post-traumatic stress disorder (PTSD) among firefighters contributes to their job-related stress. However, the relationship between burnout and PTSD in firefighters has rarely been studied. This study therefore explored the association between burnout and its related factors, such as trauma and violence, and PTSD symptoms among firefighters in Korea. Methods: A total of 535 firefighters participated in the Firefighter Research on Enhancement of Safety & Health study at 3 university hospitals from 2016 to 2017. The 535 participants received a baseline health examination, including questionnaires assessing their mental health. A Web-based survey was also conducted to collect data on job-related stress, history of exposure to violence, burnout, and trauma experience. The associations among burnout, its related factors, and PTSD symptoms were investigated using structural equation modeling. Results: Job demands (${\beta}=0.411$, p<0.001) and effort-reward balance (${\beta}=-0.290$, p<0.001) were significantly related to burnout. Burnout (${\beta}=0.237$, p<0.001) and violence (${\beta}=0.123$, p=0.014) were significantly related to PTSD risk. Trauma (${\beta}=0.131$, p=0.001) was significantly related to burnout; however, trauma was not directly associated with PTSD scores (${\beta}=0.085$, p=0.081). Conclusions: Our results show that burnout and psychological, sexual, and physical violence at the hands of clients directly affected participants' PTSD symptoms. Burnout mediated the relationship between trauma experience and PTSD.

Prioritizing Environmental Risks of Veterinary Antibiotics Based on the Use and the Potential to Reach Environment (사용량과 잠재적 환경 유출 가능성을 기준으로 한 축산용 항생제의 우선순위 결정)

  • Seo, Young-Ho;Choi, Jun-Keun;Kim, Seung-Kyeong;Min, Hwang-Kee;Jung, Yeong-Sang
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.40 no.1
    • /
    • pp.43-50
    • /
    • 2007
  • Veterinary antibiotics have been widely used to increase feed efficiency, to prevent disease, and to promote growth as well as to control disease. The antibiotics administered can be excreted through the urine and feces. One of the major routes of veterinary antibiotics entering soil and water environment is via the application of animal manure to agricultural land as an organic fertilizer source. Since little is known about impacts of antibiotics on the environment, this study was conducted to prioritize the veterinary antibiotics based on the consumption and potential to reach the environment. Among 83 veterinary antibiotics consumed in Korea, ten antibiotics were used at the greater dose than 25 Mg in 2004. Potential to reach the environment was determined according to excretion rate after administered to animals and sorption affinity to soil solids after applied to agricultural land. Seventeen antibiotic active ingredients (Ais) were classified as 'High' priority in terms of the potential to reach the environment. An overall priority score was determined by combining priority score based on consumption with the degree of potential environment exposure. Twenty veterinary antibiotic AIs were classified as 'Very high' or 'High' priority requiring detailed assessment. The antibiotic AIs were identified four aminoglycosides, two macrolides, two penicillins, five sulfonamides, three tetracyclines, two quinolones, and two miscellaneous. Eight veterinary antibiotic AIs including amoxicillin, carbadox, chlortetracycline, neomycin, oxytetracycline, sulfamethazine, sulfathiazole, and tylosin were identified to have a greater priority of environmental risk in Korea.

The Distribution of Indoor Air Pollutants by the Categories of Public-Use Facilities and Their Rate of Guideline Violation (다중이용시설별 실내공기 오염물질 농도분포 및 기준치 이상 값의 구성비 조사)

  • Joen, Jeong-In;Lee, Hye-Won;Choi, Hyun-Jin;Jeon, Hyung-Jin;Lee, Cheolmin
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.5
    • /
    • pp.398-409
    • /
    • 2021
  • Background: The types and effects of hazardous pollutants in indoor air may vary depending on the characteristics of the sources and pollutants caused by physical and chemical properties of buildings, the influence of outdoor air, and the exposure and use characteristics of residents. Objectives: This study was conducted to provide basic data on the establish of indoor air quality management for different classes of public-use facilities by presenting the characteristics of concentration distribution of hazardous pollutants by different public-use facilities and the status of the excess proportion of exceeding standards. Methods: This study analyzed self-measurement data from public-use facilities taken from 2017 to 2019 A total of 133,525 facilities were surveyed. A total of 10 types of pollutants that have maintenance and recommended standards stipulated in the Indoor Air Quality Control Act from the Ministry of Environment were investigated. The excess proportion and the substances exceeding the criteria for each type of public-use facilities for these pollutants were investigated. Results: As a result of the analysis of the proportion of exceeding the standard for each type of public-use facility, the facilities with the highest excess proportion of the standards for each hazardous pollutant were: PM10 in railway stations (8.93%), PM2.5 in daycare centers (7.36%), CO2 in bus terminals (2.37%), HCHO in postpartum care centers (4.11%), total airborne bacteria in daycare centers (0.69%), CO in museums (0.1%), NO2 in postpartum care centers (1.15%), Rn in museums (0.78%), total volatile organic compounds in postpartum care centers (7.20%) and mold in daycare centers (1.44%). Conclusions: Although uncertainty may arise because this study is a result of self-measurement, it is considered that this study has significance for providing basic data on the establishment in the future of indoor air quality management measures customized for each type of public-use facility.

Performance Analysis of Docker Container Migration Using Secure Copy in Mobile Edge Computing (모바일 엣지 컴퓨팅 환경에서 안전 복사를 활용한 도커 컨테이너 마이그레이션 성능 분석)

  • Byeon, Wonjun;Lim, Han-wool;Yun, Joobeom
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.31 no.5
    • /
    • pp.901-909
    • /
    • 2021
  • Since mobile devices have limited computational resources, it tends to use the cloud to compute or store data. As real-time becomes more important due to 5G, many studies have been conducted on edge clouds that computes at locations closer to users than central clouds. The farther the user's physical distance from the edge cloud connected to base station is, the slower the network transmits. So applications should be migrated and re-run to nearby edge cloud for smooth service use. We run applications in docker containers, which is independent of the host operating system and has a relatively light images size compared to the virtual machine. Existing migration studies have been experimented by using network simulators. It uses fixed values, so it is different from the results in the real-world environment. In addition, the method of migrating images through shared storage was used, which poses a risk of packet content exposure. In this paper, Containers are migrated with Secure CoPy(SCP) method, a data encryption transmission, by establishing an edge computing environment in a real-world environment. It compares migration time with Network File System, one of the shared storage methods, and analyzes network packets to verify safety.

Method development for efficacy testing of veterinary disinfectants using bacteriophage MS2 (Bacteriophage MS2를 이용한 소독제 효력시험 확립에 관한 연구)

  • Rhee, Chae Hong;Kim, Soohee;Han, Bokhee;Kim, Young-Wook;Her, Moon;Jeong, Wooseog
    • Korean Journal of Veterinary Service
    • /
    • v.44 no.3
    • /
    • pp.149-155
    • /
    • 2021
  • In virucidal efficacy testing, the chemical inactivation cannot be determined for all viruses due to the difficulties or the inability to culture sufficiently or the risk of exposure to the viruses. Therefore, disinfectants against these viruses could be evaluated by different methods and surrogate viruses are used as alternative. In this study we developed a method for efficacy testing of veterinary disinfectants using one of the candidate surrogate viruses, bacteriophage MS2, as part of the research on the selection of surrogate viruses for efficiency of efficacy testing of veterinary disinfectants. This method is based on the Animal and Plant Quarantine Agency (APQA) guidelines for efficacy testing of veterinary disinfectants. Bacteriophage and disinfectant are reacted in suspension in accordance with the APQA guidelines and then a newly established double agar layer method is applied for the efficacy test. The double agar layer method is summarized as follows: 1) The bottom agar with 1.5% agar is boiled and cooled before poured into petri dishes at volume of 20 mL, and dried under biological safety cabinet. 2) The top agar with 0.7% agar is boiled and kept at 50℃ before E. coli culture was seeded. 3) The serially diluted bacteriophage MS2-disinfectant mixtures 0.05 mL and E. coli host 0.01 mL (OD600 0.2~0.3) are mixed with 5 mL of top agar and incubate them at 50℃ for 5 min for reaction. 4) The resulting mixture is poured over top of a bottom agar plate and rocked sufficiently to ensure that the top agar covers the entire surface of the bottom agar. 5) The double agar layer is then placed under biological safety cabinet to allow the agar layer to solidify and subsequently incubated at 37℃ for 24 hr. 6) Following incubation, the plates may be inspected for plaques and record results.

Convergence study of blue light transmittance comparison between tips for light curing machine and commercially available blue light blocking lenses and yellow tinted lenses (광중합기용 팁과 시판용 청광 차단 렌즈 및 노란색 착색 렌즈의 청광 투과율 비교 융합 연구)

  • Lee, Sook-Jeong
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.7
    • /
    • pp.125-131
    • /
    • 2021
  • Blue light with strong energy is required for light-curing resin treatment, which is being used more frequently in dentistry. To reduce the risk of exposure to scattered light, we tried to use colored lenses. The tips for light curing machine and a commercially available yellow-type blue-light blocking lens and a yellow lens colored with yellow dye, which are expected to be effective in blocking blue light, were placed in a UV-Vis spectrometer device, and transmission and blocking of blue light were tested respectively. As a result, the average blue light blocking rate of the light curing machine tips was 99.49%, and the C lens with the highest color density among commercially available lenses showed a high blue light blocking rate of 99.54%. In the case of lenses tinted with yellow, the yellow tinted C lens with the highest tint concentration showed 87.57% of blue light blocking rate. It is judged that the side effects related to the eyes caused by blue light can be reduced if a yellow-type commercially available or colored lens is worn along with a light curing machine tip during resin treatment.

Selection of Vaccinia Virus-Neutralizing Antibody from a Phage-Display Human-Antibody Library

  • Shin, Yong Won;Chang, Ki-Hwan;Hong, Gwang-Won;Yeo, Sang-Gu;Jee, Youngmee;Kim, Jong-Hyun;Oh, Myoung-don;Cho, Dong-Hyung;Kim, Se-Ho
    • Journal of Microbiology and Biotechnology
    • /
    • v.29 no.4
    • /
    • pp.651-657
    • /
    • 2019
  • Although smallpox was eradicated in 1980, it is still considered a potential agent of biowarfare and bioterrorism. Smallpox has the potential for high mortality rates along with a major public health impact, eventually causing public panic and social disruption. Passive administration of neutralizing monoclonal antibodies (mAbs) is an effective intervention for various adverse reactions caused by vaccination and the unpredictable nature of emerging and bioterrorist-related infections. Currently, vaccinia immune globulin (VIG) is manufactured from vaccinia vaccine-boosted plasma; however, this production method is not ideal because of its limited availability, low specific activity, and risk of contamination with blood-borne infectious agents. To overcome the limitations of VIG production from human plasma, we isolated two human single-chain variable fragments (scFvs), (SC34 and SC212), bound to vaccinia virus (VACV), from a scFv phage library constructed from the B cells of VACV vaccine-boosted volunteers. The scFvs were converted to human IgG1 (VC34 and VC212). These two anti-VACV mAbs were produced in Chinese Hamster Ovary (CHO) DG44 cells. The binding affinities of VC34 and VC212 were estimated by competition ELISA to $IC_{50}$ values of $2{\mu}g/ml$ (13.33 nM) and $22{\mu}g/ml$ (146.67 nM), respectively. Only the VC212 mAb was proven to neutralize the VACV, as evidenced by the plaque reduction neutralization test (PRNT) result with a $PRNT_{50}$ of ~0.16 mg/ml (${\sim}1.07{\mu}M$). This VC212 could serve as a valuable starting material for further development of VACV-neutralizing human immunoglobulin for a prophylactic measure against post-vaccination complications and for post-exposure treatment against smallpox.

Estimation of PM10 and PM2.5 inhalation dose by travel time and respiratory volume in common transport microenvironments in Seoul, Korea (서울지역 교통수단별 이동시간과 호흡량을 고려한 미세먼지 흡입량 추정에 관한 연구)

  • Lee, Yong-Il;Jung, Wonseck;Hwang, Doyeon;Kim, Taesung;Park, Duckshin
    • Particle and aerosol research
    • /
    • v.14 no.4
    • /
    • pp.97-105
    • /
    • 2018
  • Recently, people's interest in particulate matter (PM) has been increasing, due to its hazardous health effects. The purpose of this study was to investigate the concentrations and as well as the inhaled weight of PM, correlated with person's heart rate in subway, bus, vehicle and bicycle in the major public transportation (Sadang - Jamsil and Nowon - Dongdaemun) in Seoul. The concentration of $PM_{10}$ and $PM_{2.5}$ were measured from each of transportation means and calculated the average concentrations which were 87.2 and $57.8{\mu}g/m^3$ for subway, 62.8 and $42.5{\mu}g/m^3$ for vehicle, 61.5 and $36.8{\mu}g/m^3$ for bus and 53.0 and $29.4{\mu}g/m^3$ for bicycle in $PM_{10}$ and $PM_{2.5}$ respectively. Inhalation dose for $PM_{10}$ and $PM_{2.5}$ were estimated at 248.1 and $139.4{\mu}g$ for bicycle, 56.7 and $39.3{\mu}g$ for vehicle, 49.4 and $29.9{\mu}g$ for bus and 44.3 and $29.1{\mu}g$ for subway, respectively. Even though subway had the highest concentration, the highest inhalation dose was the bicycle. It was due to the long travel time-exposure and breathing rate which leads to maximum of $PM_{10}$ 5.6 and $PM_{2.5}$ with 4.8 times inhalation dose comparing with other modes of transportation. With regards to future studies, the amount of inhalation in each transportation means should be considered in risk assessments of PM.

Evaluation of Angle Dependence on Positional Radioisotope Source Detector using Monte Carlo Simulation in NDT (몬테카를로 시뮬레이션을 이용한 방사선원 위치 검출기의 각도의존성 연구)

  • Han, Moojae;Heo, Seunguk;Shin, Yohan;Jung, Jaehoon;Kim, Kyotae;Heo, Yeji;Lee, Deukhee;Cho, Heunglae;Park, Sungkwang
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.141-146
    • /
    • 2019
  • Radiation sources used in the field of industrial non-destructive pose a risk of exposure due to ageing equipment and operator carelessness. Thus, the need for a safety management system to trace the location of the source is being added. In this study, Monte Carlo Simulation was performed to analyse the angle dependence of the unit-cell comprising the line-array dosimeter for tracking the location of radiation sources. As a result, the margin of error for the top 10% of each slope was 5.90% at $0^{\circ}$, 8.08% at $30^{\circ}$, and 20.90% at $60^{\circ}$. The ratio of the total absorbed dose was 83.77% at $30^{\circ}$ and 53.36% at $60^{\circ}$ based on $0^{\circ}$(100%) and showed a tendency to decrease with increasing slope. For all gradients, the maximum number was shown at $30^{\circ}$ No. 9 pixels, and for No. 10, there was a tendency to drop 7.24 percent. This study has shown a large amount of angle dependence, and it is estimated that the proper distance between the source and line-array dosimeters should be maintained at a distance of not less than 1 cm to reduce them.

Estimation of Ventilation Rates in Korean Homes Using Time-activity Patterns and Carbon Dioxide (CO2) Concentration (시간활동양상 및 이산화탄소 농도를 이용한 한국 주택 환기량 추정)

  • Park, Jinhyeon;Ryu, Hyeonsu;Heo, Jung;Cho, Mansu;Yang, Wonho
    • Journal of Environmental Health Sciences
    • /
    • v.45 no.1
    • /
    • pp.1-8
    • /
    • 2019
  • Objectives: The purpose of this study was to estimate the ventilation rate of residential homes in Korea through tracer gas methods using indoor and outdoor concentrations of carbon dioxide ($CO_2$) and $CO_2$ generation rates from breathing. Methods: In this study, we calculated the number of occupants in a home by time through data on the average number of people per household from the Korean National Statistical Office and also measured the amount of $CO_2$ generation by breathing to estimate the indoor $CO_2$ generation rate. To estimate the ventilation rate, several factors such as the $CO_2$ generation rate and average volume of residential house provided by the Korean National Statistical Office, indoor $CO_2$ concentrations measured by sensors, and outdoor $CO_2$ concentrations provided by the Korea Meteorological Administration, were applied to a mass balance model for residential indoor environments. Results: The average number of people were 2.53 per household and Koreans spend 61.0% of their day at home. The $CO_2$ generation rate from breathing was $13.9{\pm}5.3L/h$ during sleep and $15.1{\pm}5.7L/h$ in a sedentary state. Indoor and outdoor $CO_2$ concentrations were 849 ppm and 407 ppm, respectively. The ventilation rate in Korean residential houses calculated by the mass balance model were $42.1m^3/h$ and 0.71 air change per hour. Conclusions: The estimated ventilation rate tended to increase with an increase in the number of occupants. Since sensor devices were used to collect data, sustainable data could be collected to estimate the ventilation rate of Korean residential homes, which enables further studies such as on changes in the ventilation rate by season resulting from the activities of occupants. The results of this study could be used as a basis for exposure and risk assessment modeling.