• Title/Summary/Keyword: right inverse

Search Result 65, Processing Time 0.026 seconds

A Visual Reconstruction of Core Algorithm for Image Compression Based on the DCT (discrete cosine transform) (이산코사인변환 기반 이미지 압축 핵심 알고리즘 시각적 재구성)

  • Jin, Chan-yong;Nam, Soo-tai
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.10a
    • /
    • pp.180-181
    • /
    • 2018
  • JPEG is a most widely used standard image compression technology. This research introduces the JPEG image compression algorithm and describes each step in the compression and decompression. Image compression is the application of data compression on digital images. The DCT (discrete cosine transform) is a technique for converting a time domain to a frequency domain. First, the image is divided into 8 by 8 pixel blocks. Second, working from top to bottom left to right, the DCT is applied to each block. Third, each block is compressed through quantization. Fourth, the array of compressed blocks that make up the image is stored in a greatly reduced amount of space. Finally if desired, the image is reconstructed through decompression, a process using IDCT (inverse discrete cosine transform).

  • PDF

Prewhitening Method for LFM Reverberation by Linear Dechirping (선형 Dechirping 기법을 이용한 LFM 잔향의 백색화 기법)

  • Choi, Byung-Woong;Kim, Jeong-Soo;Lee, Kyun-Kyung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.26 no.3
    • /
    • pp.129-135
    • /
    • 2007
  • In this paper. we propose a prewhitening method for the km reverberation to enhance the target signal. The proposed algorithm uses the dechirping method which inversely compensates the frequency chirp rate of LFM and transforms the LFM reverberation to have stationary frequency property in each data block. Also, using the left and right adjacent beam signals as reference signals. we model frequency response of each data block by AR coefficients. From these coefficients, we implement inverse filter and prewhiten the LFM reverberation of the center beam efficiently.

Assessment of Right Ventricular Function in Patients with Chronic Obstructive Pulmonary Disease Using Echocardiographic Tei Index (만성 폐쇄성 폐질환 환자에서 Tei 지수를 이용한 우심실기능 평가)

  • Oh, Yoon-Jung;Shin, Joon-Han;Kim, Deog-Ki;Choi, Young-Hwa;Park, Kwang-Joo;Hwang, Sung-Chul;Lee, Yi-Hyeong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.50 no.3
    • /
    • pp.343-352
    • /
    • 2001
  • Background : Advanced chronic obstructive pulmonary disease is characterized by progressive pulmonary hypertension leading to right heart dysfunction, which plays a Important role in clinical evaluation but remains difficult and challenging to quantify. The noninvasive doppler echocardiographic value referred to as the Tei index has been suggested as a simple, reproducible and reliable parameter of the right ventricular function. The purpose of this was to assess the right ventricular function in patients with chronic obstructive pulmonary disease using the Tei index and to evaluate its relationship with the pulmonary functional status. Methods : The study population comprised of 26 patients with chronic obstructive pulmonary disease and 10 normal control subjects. The Tei index was obtained by dividing the sum of the isovolumetric contraction and the relaxation times by the ejection time using a pulsed-wave doppler. It was compared with the other available Doppler echocardiographic parameters of systolic or diastolic function and with the pulmonary function of the patients. Results : The Tei indices of the patients with COPD were significantly higher than those of normal subjects($0.45{\pm}0.17$ vs. $0.27{\pm}0.03$, p<0.01). The isovolumetric contraction time/ejection time($0.32{\pm}0.08$ vs. $0.25{\pm}0.05$, p<0.05), the isovolumetric relaxation time/ejection time($0.29{\pm}0.16$ vs. $0.15{\pm}0.08$, p<0.05)and the preejection period/ejection time ($0.46{\pm}0.10$ vs. $0.38{\pm}0.06$, p<0.05) were prolonged and the ejection time ($255.2{\pm}32.6$ vs. $314.2{\pm}16.5$ msec, p<0.05) was significantly shortened in patients with COPD compared to normal subjects. The tei indices were inversely correlated with the $FEV_1$ (r=-0.46, p<0.05) and were prolonged significantly in patients with a severe obstructive ventilatory dysfunction(less than 35% of predicted $FEV_1$) compared to those with a mild and moderate ventilatory dysfunction. The tei indices showed an inverse correlation to with the ejection time (r=-0.469), the isovolumetric contraction time/ejection time(r=0.453), the isovolumetric relaxation time/ejection time(r=0.896) and the preejection period/ejection time(r=0.480). Conclusion : The tei index appeared to be a useful noninvasive means of evaluating the right ventricular function. It revealed a significant correlation with the pulmonary function in patients with COPD.

  • PDF

Alteration of Coagulation and Fibrinolysis System According to Right Ventricular Dysfunction in Chronic Obstructive Pulmonary Disease (만성폐쇄성폐질환에서 우심실 기능 부전에 따른 혈액응고 및 섬유소용해계 변화)

  • Kim, Young;Jang, Yoon Soo;Kim, Hyung Jung;Kim, Se Kyu;Chang, Joon;Ahn, Chul Min;Kim, Sung Kyu;Kwak, Jin Young;Choi, Jin Hwa
    • Tuberculosis and Respiratory Diseases
    • /
    • v.60 no.6
    • /
    • pp.625-630
    • /
    • 2006
  • Background: Pulmonary hypertension in COPD patients is the result of a direct effect of tobacco smoke on the intrapulmonary vessels with the abnormal production of the mediators that control vasoconstriction, vasodilatation, and vascular cell proliferation, which ultimately lead to aberrant vascular remodeling and physiology. COPD patients are prone to the developmint of an acute and chronic thromboembolism with an elevation of the plasma procoagulant and fibrinolytic markers However, the roles of the coagulation and fibrinolysis system on the right ventricular dysfunction in COPD patients are not well defined. We examined the alteration of the coagulation and fibrinolysis system in COPD patients according to the right ventricular function measured using cardiac multidetector computed tomography (MDCT). Methods: The right ventricular ejection fraction (RVEF) was measured using cardiac MDCT in 26 patients who were diagnosed with COPD according to the definition of the GOLD guideline. The plasma level of thrombin antithrombin (TAT) and plasminogen activator inhibitor (PAI)-1 were measured using an enzyme linked immunoassay. Results: The plasma TAT was markedly elevated in COPD patients ($10.5{\pm}19.8{\mu}g/L$) compared with those of the control ($3.4{\pm}2.5{\mu}g/L$) (p<0.01). However, the plasma PAI-1 in COPD patients ($29.6{\pm}20.7ng/mL$) was similar to that in the controls. The plasma TAT showed a significant inverse relationship with the RVEF measured by the cardiac MDCT in COPD patients (r=-0.645, p<0.01). However, the plasma PAI-1 did not show a relationship with the RVEF (r=0.022, p=0.92). Conclusion: These results suggest that the coagulation system in COPD patients is markedly activated, and that the plasma level of TAT might be a marker of a right ventricular dysfunction in COPD patients.

VLSI Design of DWT-based Image Processor for Real-Time Image Compression and Reconstruction System (실시간 영상압축과 복원시스템을 위한 DWT기반의 영상처리 프로세서의 VLSI 설계)

  • Seo, Young-Ho;Kim, Dong-Wook
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.1C
    • /
    • pp.102-110
    • /
    • 2004
  • In this paper, we propose a VLSI structure of real-time image compression and reconstruction processor using 2-D discrete wavelet transform and implement into a hardware which use minimal hardware resource using ASIC library. In the implemented hardware, Data path part consists of the DWT kernel for the wavelet transform and inverse transform, quantizer/dequantizer, the huffman encoder/huffman decoder, the adder/buffer for the inverse wavelet transform, and the interface modules for input/output. Control part consists of the programming register, the controller which decodes the instructions and generates the control signals, and the status register for indicating the internal state into the external of circuit. According to the programming condition, the designed circuit has the various selective output formats which are wavelet coefficient, quantization coefficient or index, and Huffman code in image compression mode, and Huffman decoding result, reconstructed quantization coefficient, and reconstructed wavelet coefficient in image reconstructed mode. The programming register has 16 stages and one instruction can be used for a horizontal(or vertical) filtering in a level. Since each register automatically operated in the right order, 4-level discrete wavelet transform can be executed by a programming. We synthesized the designed circuit with synthesis library of Hynix 0.35um CMOS fabrication using the synthesis tool, Synopsys and extracted the gate-level netlist. From the netlist, timing information was extracted using Vela tool. We executed the timing simulation with the extracted netlist and timing information using NC-Verilog tool. Also PNR and layout process was executed using Apollo tool. The Implemented hardware has about 50,000 gate sizes and stably operates in 80MHz clock frequency.

Assessment of NATM tunnel lining thickness and its behind state utilizing GPR survey (GPR탐사를 통한 NATM터널(무근)라이닝의 두께 분포 및 배면상태 평가)

  • Choo, Jin-Ho;Yoo, Chang-Kyoon;Oh, Young-Chul;Lee, In-Mo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.5
    • /
    • pp.717-733
    • /
    • 2019
  • In this study, lining thickness distribution and its behind state (particularly, its void state) were analyzed using the GPR survey data performed on three currently operating NATM tunnels. Results of GPR analysis showed that void areas were mostly detected between concrete lining and primary support, particularly, near the crown of the tunnels. The lining thickness in the left-hand side of the tunnel was different from that of the right-hand side by 8.6~253.5 mm when measured in transverse direction. It was also found that longitudinal cracks were prevailed in the area lining thickness was sharply changed. Longitudinal thickness distribution at the crown was also studied and tested by performing 3 goodness-of-fit tests in order to find the most suitable thickness distribution. Normal distribution (or similar distribution) fit most suitably to the measured data if the measured average thickness was larger than designed one; Gamma and/or Inverse Gauss distribution fit to the measured data reasonably well if the measured average thickness was less than the designed value of thickness. Since actual lining thickness can be a potential index when assessing the state and safety of the unreinforced NATM tunnel lining, measuring of the lining thickness with GPR survey might be needed rather than assuming the thickness is always constant and same with the designed value.

Retrospective Analysis on Body Weight Changes in the Early Postpartum Period of Women of High-risk Pregnancy Experience and General Health after Korean Medicine Treatments. (산후 한의진료를 받은 고위험산모와 일반산모의 한의진료 체중변화에 대한 후향적 분석)

  • Lee, Eun-Hee
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.34 no.3
    • /
    • pp.65-78
    • /
    • 2021
  • Objectives: This study was aimed to investigate the weight change of the high-risk group and the general maternal group and weight-relating factors in the early postpartum period. Methods: We retrospectively reviewed the medical records of those who received postpartum care from January 1, 2020, to December 31, 2020, in the postpartum care center affiliated with one Korean Medicine hospital. A total of 257 postpartum women's medical charts were included and divided into the high-risk group and the general maternal group. We investigated the weight changes and Body mass index (BMI) of the postpartum women and compared the difference between the two groups after taking the postpartum care. Finally, we used a Pearson correlation analysis to identify the weight-relating factors in the early postpartum period. Results: All the postpartum women showed the following results; 33.81±4.03 years old as the mean age; 22.23±3.28 as pre-pregnancy BMI; 58.21±9.18 kg of pre-pregnancy weight increased into 70.75±9.70 kg in the last month of pregnancy. Of the total 257 patients, 149 (58.0%) of high-risk pregnancy experience and 108 (42.0%) of general pregnancy were included. The edema index right after childbirth was significantly higher in the high-risk group than in the general maternal group (p<0.001), but there was no significant difference in BMI. After treatment with Korean medicine treatments, body weight, BMI, and edema index decreased significantly in both groups (p<0.01). As a result of correlation analysis, weight gain during pregnancy had a significant negative correlation with pre-pregnancy weight and pre-pregnancy BMI and a significant positive correlation with weight and BMI of the last month of pregnancy. In particular, pre-pregnancy BMI and body weight showed a significant negative correlation only in the high-risk group. Postpartum weight loss was significantly positively correlated with pre-pregnancy weight, pre-pregnancy BMI, weight & BMI of the pregnancy last month, weight gain during pregnancy, and decrease in edema (p<0.01) Conclusions: The weight during pregnancy of the high-risk group increased in inverse proportion to the pre-pregnancy BMI. The level of edema right after childbirth was significantly higher than that of the general maternal group, but showed a significant decrease after 2 weeks of Korean medicine treatments. Although it implicates the need for active Korean medicine treatments in the early postpartum period, further studies with controlled groups are needed.

Performance Evaluation of EEG-BCI Interface Algorithm in BCI(Brain Computer Interface)-Naive Subjects (뇌컴퓨터접속(BCI) 무경험자에 대한 EEG-BCI 알고리즘 성능평가)

  • Kim, Jin-Kwon;Kang, Dae-Hun;Lee, Young-Bum;Jung, Hee-Gyo;Lee, In-Su;Park, Hae-Dae;Kim, Eun-Ju;Lee, Myoung-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.5
    • /
    • pp.428-437
    • /
    • 2009
  • The Performance research about EEG-BCI algorithm in BCI-naive subjects is very important for evaluating the applicability to the public. We analyzed the result of the performance evaluation experiment about the EEG-BCI algorithm in BCI-naive subjects on three different aspects. The EEG-BCI algorithm used in this paper is composed of the common spatial pattern(CSP) and the least square linear classifier. CSP is used for obtaining the characteristic of event related desynchronization, and the least square linear classifier classifies the motor imagery EEG data of the left hand or right hand. The performance evaluation experiments about EEG-BCI algorithm is conducted for 40 men and women whose age are 23.87${\pm}$2.47. The performance evaluation about EEG-BCI algorithm in BCI-naive subjects is analyzed in terms of the accuracy, the relation between the information transfer rate and the accuracy, and the performance changes when the different types of cue were used in the training session and testing session. On the result of experiment, BCI-naive group has about 20% subjects whose accuracy exceed 0.7. And this results of the accuracy were not effected significantly by the types of cue. The Information transfer rate is in the inverse proportion to the accuracy. And the accuracy shows the severe deterioration when the motor imagery is less then 2 seconds.

The role of Under-balcony Speaker in the Multimedia Environmental (멀티미디어 환경에서 언더발코니 스피커의 역할)

  • Song, Deog-Geun;Park, Eun-Jin;Lee, Seon-Hee
    • Journal of Satellite, Information and Communications
    • /
    • v.10 no.2
    • /
    • pp.86-89
    • /
    • 2015
  • Formula acoustic characteristics of the room with a double layer, are compared through simulation and actual measurement. The rear area of the under- balcony speakers will cause a delay difference between the main speaker. In the mid / bass parts do not generate sufficient pressure is lowered and comb-Filtering phenomenon occurs significantly. The lower right area of the under- balcony speakers and speaker distance is the sound pressure of the under- balcony speakers to around 2 ~ 3m bigger than the main speakers and the sound image matches the pulpit is broken. Also, under area is more than 5 ~ 6m from the balcony outside speakers and causes differ by more than 10dB lower than the under- balcony speakers depending on the local laws of Translator wins Well, the main speaker at mid / high frequency sounds do not enter the sound pressure variations will drop by a significant. Appropriate arrangement and the output of the speaker according to the position under the balcony, and output of the main speakers are requested to minimize this problem sound. The proper sound design direction for the under- balcony speakers must be presented in order to improve the lower balcony area more pleasant acoustic environment.

Body Composition Variations for Cerebral Infarction Patients Classified as Male and Female in Long-term Care Hospitals

  • Yoo, Chan-Uk;Hwang, Youngjun;Kim, Gunho;Hahn, Eun Joo;Jeon, Gyerok;Kim, Jaehyung
    • Journal of Korea Multimedia Society
    • /
    • v.21 no.6
    • /
    • pp.723-735
    • /
    • 2018
  • Indicators to quantitatively assess the physical conditions can help optimize the effectiveness of rehabilitation therapy for stroke patients. The body composition variations in the paretic and non-paretic regions of stroke patients with cerebral infarction (7 males, 31 females) were analyzed using multi-frequency bioelectrical impedance. Specifically, resistance (R), lean mass (LM), fat mass (FM), extracellular water (ECW), intracellular water (ICW), R/LM relation, basal metabolic rate (BMR)/LM relation were utilized to evaluate the paretic and non-paretic regions of subjects with cerebral infarction. These values showed significant differences in gender and paretic/non-paretic regions. R and FM were high but LM and ICW were lower in female and paralysis. ECW was lower in females than males, but there was no considerable difference between paralysis and non-paralysis in both males and females. In addition, there was an inverse distribution between R and LM in paretic and non-paretic regions, with males on the upper left and females on the lower right. Furthermore, the relationship between BMR and LM showed excellent linearity (slope: 22.17 kcal/day/kg) irrespective of gender, paralysis, and non-paralysis. An easy, non-invasive and quantitative assessment using bioelectrical impedance would provide an useful tool for evaluating patients with cerebral infarction receiving rehabilitation therapy.