• Title/Summary/Keyword: reverse operation

Search Result 384, Processing Time 0.024 seconds

New convergence scheme to improve the endurance characteristics in flash memory (새로운 Convergence 방법을 이용한 플래시 메모리의 개서 특성 개선)

  • 김한기;천종렬;이재기;유종근;박종태
    • Proceedings of the IEEK Conference
    • /
    • 2000.06b
    • /
    • pp.40-43
    • /
    • 2000
  • The electrons and holes trapped in the tunneling oxide and interface-states generated in the Si/SiO$_2$ interface during program/erase (P/E) operations are known to cause reliability problems which can deteriorate the cell performance and cause the V$_{th}$ window close. This deterioration is caused by the accumulation of electrons and holes trapped in the oxide near the drain and source side after each P/E cycle. we propose three new erase schemes to improve the cell's endurance characteristics: (1)adding a Reverse soft program cycle after the source erase operation, (2)adding a detrapping cycle after the source erase operation, (3)adding a convergence cycle after the source erase operation. (3) is the most effective performance among the three erase schemes have been implemented and shown to significantly reduce the V$_{th}$ window close problem. And we are able to design the reliable periperal circuit of flash memory by using the (3).(3).

  • PDF

PID Tuning Based on RCGA Using Ziegler-Nichols Method (Ziegler-Nichols를 이용한 실수코딩 유전 알고리즘 기반의 PID 튜닝)

  • Park, Ji-Mo;Kim, Go-Eun;Kim, Jin-Sung;Park, Sung-Man;Heo, Hoon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.5
    • /
    • pp.475-481
    • /
    • 2009
  • Real-coded genetic algorithm(RCGA) has better performances than conventional genetic algorithm about dealing with a large domain, the precision and the constrain problem. Also the RCGA has advantage of operation time because it doesn't have to following about decoding operation. In this paper the ranges of PID gains are limited based on Ziegler-Nichols method to consider a long operation time problem that is the main problem of genetic algorithm. Result shows proposed method represents better performance without ignored about result of ZN tuning method and reduces the calculation time.

Compensation Technique for Current Sensorless Digital Control of Bridgeless PFC Converter under Critical Conduction Mode

  • Kim, Tae-Hun;Lee, Woo-Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.6
    • /
    • pp.2310-2318
    • /
    • 2018
  • Critical conduction mode (CRM) operation is more efficient than continuous conduction mode (CCM) operation at low power levels because of the valley switching of switches and elimination of the reverse recovery losses of boost diodes. When using a sensorless digital control method, an error occurs between the actual and the estimated current. Because of the error, it operates as CCM or discontinuous conduction mode (DCM) during CRM operation and also has an adverse effect on THD of input current. In this paper, a current sensorless technique is presented in an inverter system using a bridgeless boosted power factor correction converter, and a compensation method is proposed to reduce CRM calculation error. The validity of the proposed method is verified by simulation and experiment.

A Viterbi Decoder with Efficient Memory Management

  • Lee, Chan-Ho
    • ETRI Journal
    • /
    • v.26 no.1
    • /
    • pp.21-26
    • /
    • 2004
  • This paper proposes a new architecture for a Viterbi decoder with an efficient memory management scheme. The trace-back operation is eliminated in the architecture and the memory storing intermediate decision information can be removed. The elimination of the trace-back operation also reduces the number of operation cycles needed to determine decision bits. The memory size of the proposed scheme is reduced to 1/($5{\times}$ constraint length) of that of the register exchange scheme, and the throughput is increased up to twice that of the trace-back scheme. A Viterbi decoder complying with the IS-95 reverse link specification is designed to verify the proposed architecture. The decoder has a code rate of 1/3, a constraint length of 9, and a trace-forward depth of 45.

  • PDF

Counter-Rotating Type Pumping Unit (Impeller Speeds in Smart Control)

  • Kanemoto, Toshiaki;Komaki, Keiichi;Katayama, Masaaki;Fujimura, Makoto
    • International Journal of Fluid Machinery and Systems
    • /
    • v.4 no.3
    • /
    • pp.334-340
    • /
    • 2011
  • Turbo-pumps have weak points, such as the pumping operation is unstable on the positive slope of the head curve and/or the cavitation occurs at the low suction head. To improve simultaneously both weak points, the first author invented the unique pumping unit composed of the tandem impellers and the peculiar motor with the double rotational armatures. The front and the rear impellers are driven by the inner and the outer armatures of the motor, respectively. Both impeller speeds are automatically and smartly adjusted in response to the pumping discharge, while the rotational torques between both impellers/armatures are counter-balanced. Such speeds contribute to suppress successfully not only the unstable operation at the low discharge but also the cavitation at the high discharge, as verified with the axial flow type pumping unit in the previous paper. Continuously, this paper investigates experimentally the effects of the tandem impeller profiles on the pump performances and the rotational speeds against the discharge, using the impellers whose loads are low and/or high at the normal discharge. The worthy remarks are that (a) the unstable operation is suppressed as expected and the shut off power is scarcely large in the smart control, (b) the blade profile contributes to determine the discharge giving the maximum/minimum rotational speed where the reverse flow may incipiently appears at the front impeller inlet, (c) the tandem impeller profiles scarcely affect the rotational speeds, while the loads of the front and the rear impellers are same, but (d) the impeller with the low load must run faster and the impeller with the high load must run slower at the same discharge to take the same rotational torque, and (e) the reverse flow at the inlet and the swirling velocity component at the outlet of the front impeller with the high load require making the rotational speed of the rear impeller with low load fairly faster at the lower discharge.

A Study on the wiring Control Method of Hand & Auto Operation of an easy Elevator (간이 승강기 수.자동 배선제어방식에 관한 연구)

  • Wee, Sung-Dong;Gu, Hal-Bon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.596-602
    • /
    • 2002
  • An easy elevator for learning originated is opened to compare the existed learning equipment, and it had a high studying efficient that the sequence control circuit can opens and closes with the wire. The structure of equipment to be controlled from the first floor to the fifth floors is demonstrated a constructive apparatus by a lamp atc to express the function of the open-close of the door according to the cage moving with a mechanical actuation of the forward-reverse breaker and the motor of load and a mechanical actuation of hand-operation control components of push-button S/W and L/S and relay etc. These components let connects each other in order to control of the elevator function with the auto program and the designed sequence control circuit. Consequent1y the process of these functions of 1~5steps could operates the cage with an auto program of the elevator and the sequence control circuit. The sequence control circuit is controlled by the step of forward and reverse to follow as that the sensor function of the L/S1~L/S5 let posit with the control switchs of S/W1~S/W5 of PLC testing panel and switchs of S/W1~S/W5 installed on the transparent acryl plate of the frame. In here, improved apparatus is a hand-auto operation combined learning equipment to study the principle and a technique of the originated sequence control circuit and the auto program of PLC.

  • PDF

Development of the Pilot System for Radioactive Laundry Waste Treatment Using UV Photo-Oxidation Process and Reverse Osmosis Membrane

  • Park, Se-Moon;Park, Jong-Kil;Kim, Jong-Bin;Shin, Sang-Woon;Lee, Myung-Chan
    • Nuclear Engineering and Technology
    • /
    • v.31 no.5
    • /
    • pp.506-511
    • /
    • 1999
  • The pilot system for radioactive liquid laundry waste was developed with treatment capacity, 1ton/hr and set up in the Yong Kwang unit #4. The system is composed of tank module, RO systems and a UV/$H_2O$$_2$photo-oxidation unit. The RO system consists of the BW unit (low-pressure RO for brackish water desalination) and the SW unit (high-pressure RO for seawater desalination). The BW unit possesses 4 RO membranes and it can reduce the feed water volume down to 1/10. This concentrated feed water can be reduced again up to 1/10 in its volume in the SW unit composed of 4 RO membranes. The UV/$H_2O$$_2$ photo-oxidation process unit was used for the detergent degradation. The operation of the pilot system was carried out and verified in its capability through the continuous operation and concentration operation using the actual liquid waste from the power plant. The design criteria and data for industrialization were yielded. The efficiency of the UV/$H_2O$$_2$ photo-oxidation process and the optimum operational procedure were evaluated. The decontamination factors for radioactive cobalt and cesium were measured. This on-site test showed the experimental result in the DF$\geq$300 and volume reduction factor$\geq$100.

  • PDF

Development of Hardware and Monitoring Software for Stable Operation of Fire Pumps (소방펌프의 안정적 운영을 위한 하드웨어 및 모니터링 소프트웨어 개발)

  • Ku, Bonhyu;Kim, Doo-Hyun;Kim, Sung-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.4
    • /
    • pp.28-35
    • /
    • 2022
  • This study is aimed to develop a safety diagnosis system for fire pumps that detects normal and abnormal signals for the stable operation of the system. Hence, the following activities were carried out: first, a threshold value was identified for the normal operation and six abnormal operations (adherence of impeller, absence of water source, separation of pump and motor, run-stop operation, air inflow into the casing, and reverse-phase loss of the power line) reflecting changes in the current, flow and pressure of fire pumps; secondly, based on the identified signals, an algorithm capable of detecting three abnormal signals was developed and in terms of hardware, a current, pressure and flow sensor suitable for the analogue input values of NI-6009 was designed and installed. This combination of the hardware and software is applicable as a diagnosis system to ensure the stable operation of fire pumps.

Design of high-speed preamble searcher adequate for RACH preamble structure in WCDMA reverse link receiver (RACH 프리앰블 구조에 적합한 WCDMA 역방향 링크 수신기용 고속 프리앰블 탐색기의 설계)

  • 정은선;도주현;이영용;정성현;최형진
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.8A
    • /
    • pp.898-908
    • /
    • 2004
  • In this paper, we propose a high speed preamble searcher feasible for RACH(Random Access Channel) preamble structure in WCDMA reverse link receiver. Unlike IS-95, WCDMA system uses AISMA(Acquisition Indication Sense Multiple Access) process. Because of the time limit between RACH preamble transmission and AI(Acquisition Indicators), and the restriction on the number of RACH signatures assigned to RACH preamble, fast acquisition indication is required for efficient operation. The preamble searcher proposed in this paper is based on 2-antenna system and has adopted FHT algorithm that has the radix-2 16 point FFT structure. The acquisition speed using FHT is 64 times faster than the conventional method that correlates each signature. Based on their fast aquisition scheme, we improved the acquisition performance by calculating the correlation up to the 4096 chips of the total preamble length. The performance is analyzed by using Neyman-pearson method. The proposed algorithm has been applied for the implementation of WCDMA reverse link receiver modem successfully.

Development of Electric Actuator Position Control System for Automatic Shuttle Shifting of Tractor (트랙터의 전후진 자동 변속을 위한 전자식 액추에이터의 위치 제어 시스템 개발)

  • Choi, Chang-Hyun;Woo, Mi-Na;Lee, Dae-Hyun;Kim, Yong-Joo;Jeong, Jin-Hee
    • Journal of Biosystems Engineering
    • /
    • v.35 no.4
    • /
    • pp.224-230
    • /
    • 2010
  • The purpose of this study was to develop position control system of an electric actuator for automatic shuttle shifting of a tractor. The electric actuator was installed at the link of the forward-reverse gearshift of the tractor transmission, and controlled in the ranges of forward, neutral, and reverse positions. The position control system of the electric actuator was developed based on PID (Proportional Integral Derivative) controller and transfer function of the electric actuator. The coefficients of the PID controller were determined by Ziegler-Nichols (Z-N) method and optimized using simulation program. The prototype AMT (Automated Manual Transmission) test unit of the tractor was installed and used to evaluate the performance of the position control. The evaluation system for the control performance consisted of forward-reverse actuator, motor driver, and controller. The tests were conducted as the controlled positions of the actuator were changed from neutral position to forward, neutral, and reverse positions in sequence. The sequential tests were repeated 20 times. The operations of changing the gearshift were considered as the step response of the control system. Maximum overshoot, settling time, and steady-state error were analyzed. The results showed that performance of the position control system was reasonable and qualified. The maximum overshoots, the steady-state errors, and the settling times of the position control system were 10~20%, 1~5%, and 0.92~1.49 sec, respectively. The modifications of the electric actuator will be required to enhance the performance of position control during field operation.