• 제목/요약/키워드: reverberation room method

검색결과 69건 처리시간 0.02초

축소잔향실의 저주파수 확산음장 형성 방법에 대한 연구 (Study on method of build up low-frequency diffuse sound field in a scaled reverberation chamber)

  • 강준구;강현주;김상렬;최종수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.61-64
    • /
    • 2007
  • This study is dealt with a method to enhance low-frequency diffuse sound field in a scaled reverberation chamber. Because scaled reverberation chamber has not enough room volume, as a result, it shows a few room modes. So it is not build up low-frequency diffuse sound field. A Helmholtz resonator's arrangement is used to improve spatial uniformity of sound pressure at low frequency. The spatial distribution of sound field has been measured before and after control. The standard deviation of sound field has decreased at 315Hz 1/3 Octave band.

  • PDF

관내법을 이용한 흡.차음 성능 측정방법 (A measuring technology of the absorption ratio and the transmission loss using the tube method)

  • 이장명;김동률
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1998년도 춘계학술대회논문집; 용평리조트 타워콘도, 21-22 May 1998
    • /
    • pp.659-663
    • /
    • 1998
  • To measure the absorption ratio and the transmission loss of a material, a usage of the reverberation room has been popular. However, the reverberation room is expensive to build it and, sometimes, test procedure is not easy. Therefore, to get the data of absorption ratio, several possible technologies has been proposed using the tube. Among these technologies, with the analysis of the spectral density, a convenient method has been introduced to measure both the absorption ratio and transmission loss. The measured data has been compared with the results of the measurement at the reverberation room.

  • PDF

임펄스응답을 이용한 실내음향 측정 시스템 (Room Acoustic Measurement System Using Impulse Response)

    • 한국음향학회지
    • /
    • 제18권5호
    • /
    • pp.63-67
    • /
    • 1999
  • 최근 들어 실내음향 특성의 측정과 평가를 위해 백색잡음을 이용한 잔향시간 측정법 대신에 임펄스응답을 이용한 측정법이 널리 이용되고 있다. 이 방법은 재현성이 우수하고 다양한 실내음향 특성치들을 한꺼번에 산출할 수 있어 전통적인 잔향시간 측정법에 비해 여러 가지 장점을 가지고 있다. 본 연구에서는 MLS(Maximum Length Sequence) 신호를 이용하여 실내에서의 임펄스 응답을 측정하고 이를 후처리(post-processing) 하여 잔향시간(EDT, RT), 명료도 지수(C50, C80, D, U50, U80, AI), 음의 크기 지수(G) 등, 주로 실의 음성음향 성능을 측정하는 시스템을 구축하였다. 본 연구에서는 측정시스템과 후처리 프로그램의 구성, 몇몇 실내공간에 대한 시험 측정의 결과 및 고찰 등에 대해 소개하고자 한다.

  • PDF

수음실 잔향 시간변화에 따른 바닥충격음레벨 특성 - 잔향실을 중심으로 - (Floor Impact Sound Pressure Level Characteristics by the Change of Reverberation Time in a Reverberation Chamber)

  • 정정호;김정욱;정재군
    • 한국소음진동공학회논문집
    • /
    • 제23권3호
    • /
    • pp.274-281
    • /
    • 2013
  • Field measurement method of heavy/soft impact sound pressure level which is regulated in JIS and ISO has been using in Korea, Japan and Canada. It is reported that heavy/soft impact sound pressure level was varied by the sound field condition of receiving room such as sound absorption power and room volume. In this study, it is checked that heavy/soft impact sound pressure level was affected by the receiving sound field condition. Rubber ball and bang machine sound pressure level was measured in the vertically connected reverberation chamber. In oder to check the effect of receiving sound field on heavy/soft impact sound pressure, sound absorption power was changed with polyester sound absorption blankets with air space and glass wool. The reverberation time at 1 kHz band was changed from 10 s to 0.2 s by sound absorption material. Rubber ball sound pressure level measured without sound absorption material was 58 dB in $L_{i,Fmax,AW}$, but the level was 46 dB with sound absorption treatment. From this result, it is confirmed that sound field correction method is needed in the heavy/soft impact sound pressure level measurement method using bang machine and rubber ball.

시편의 크기에 따른 흡음계수 변화 연구 (A Study on the Sound Absorption Coefficient by Varying Sample Size)

  • 정성수;이우섭;조문재;서상준
    • 한국소음진동공학회논문집
    • /
    • 제11권5호
    • /
    • pp.83-88
    • /
    • 2001
  • The sound absorption coefficient of glass wool (bulk density of 48 kg/m:1 and 32 kg/m7) was measured by reverberation room method as varying their cross-sectional area. The results show that the absorption is larger for smaller samples because of edge effect. The absorption coefficient with two different kinds of sources. 1/.7-octave band and while noise, gives similar values.

  • PDF

잔향실의 음압분포해석 및 계측치와의 비교 (An Analysis of Sound Pressure Distribution in a Reverberation Room and Comparisons with Measurements)

  • 김현실;김재승;강현주;김상렬
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1997년도 춘계학술대회논문집; 경주코오롱호텔; 22-23 May 1997
    • /
    • pp.669-674
    • /
    • 1997
  • A sound field in a reverberation room is analyzed by using numerical methods and the SPL distributions are compared to the measurements. In numerical predictions, the BEM is employed in the low frequency range, while sound ray tracing method is used for the high frequency range. In the BEM analysis, the surfaces of the empty reverberation room are assumed as rigid boundaries and the damping coefficients are estimated from the measured absorption coefficient. The comparisons with measurements for 100Hz shows good agreement. In the sound ray tracing analysis, the predicted energy decay are in excellent agreements with theoretical results. It is shown that the energy absorption by air damping plays an important role as frequency becomes higher.

  • PDF

충격 시험의 출력 데이터에 기초한 유사잔향 시간을 이용한 도자기의 결함 탐지법 (Fault Detection Method for Ceramic Cup by Pseudo Reverberation Time Based on Output Data by Impact Test)

  • 박석태
    • 한국음향학회지
    • /
    • 제25권6호
    • /
    • pp.257-268
    • /
    • 2006
  • 도자기 컵의 결함여부를 판정하는 간편한 방법으로 실내에서 충격 시험으로 추정한 유사잔향시간을 사용하는 방법을 제시하였다. 정상적인 도자기 컵과 미세한 균열이 있는 컵에 대하여 충격 시험을 하여 발생하는 충격음에서 구한 슈레더 곡선에서 잔향 시간을 추정하였다. 충격 가진 막대의 종류와 가진 위치, 경계 조건에 따라 잔향 시간을 추정하였고 추정된 잔향 시간으로부터 도자기 컵의 결함 유무를 효과적으로 파악할 수 있는지를 기술하였다

5자유도 잔향 모델을 이용한 실내 잔향 필터 설계를 위한 조건 (Constraints for the Design of Room Reverberation Filter by Using 5-DOF Reverberation Model)

  • 김소희;김양한
    • 한국음향학회지
    • /
    • 제20권2호
    • /
    • pp.58-65
    • /
    • 2001
  • 잔향에 대한 인간의 주관적인 지각을 객관적인 수치로써 나타내는 방법으로 5자유도 잔향 모델이 제안된 바 있다[1]. 5자유도 잔향 모델은 잔향에 대한 다섯 개의 객관적인 평가량들을 이용하여 시간에 따른 음 에너지 감쇠 곡선을 근사한 것으로, 인공적으로 잔향을 합성하고자 할 때 잔향 필터의 설계 기준으로 유용하게 사용될 수 있다. 그러나 이로부터 구현할 수 있는 잔향 필터는 이론적으로 무한히 많을 수 있고, 따라서 인간이 듣기에 부자연스러운 합성음을 만들어 내는 경우도 존재할 수 있다. 본 논문은 5자유도 잔향 모델의 한계를 시간 영역과 주파수 영역으로 나누어 살펴보고 잔향 모델, 즉 원하는 잔향 조건이 주어졌을 때 자연스러운 잔향을 얻기 위해 필요한 필터 설계 기준을 실제 청음 실험을 통하여 제시하고 있다.

  • PDF

전통주택의 차음성능 평가에 관한 실험적 연구 (An Experimental Study on the Sound Insulation Performance of Korean Traditional Houses)

  • 김선우;이태강;김형렬;김항;최은석
    • 한국소음진동공학회논문집
    • /
    • 제16권2호
    • /
    • pp.141-148
    • /
    • 2006
  • Korean traditional houses have been evolved and developed in many years, adopting the natural environment to control exterior conditions. These control method are various Passive system of using natural materials, considering micro climate, building lay out, and these system are much natural and ecological to make the comfortable indoor climate than active systems of the present houses. This study aims to analyzed the acoustical characteristics of Korean traditional houses varied with lay out and floor plan to reflect the way of control for environmental condition. The reverberation time and level difference between rooms of the main living room and other main floored room, master room and kitchen are measured in each houses. As a result, the reverberation time of Korean traditional rooms are below 0.6 second, and the sound insulation performance of Korean traditional door are mostly very low grade with D-15. The level difference between rooms are low grade not to meet minimum class except between main living room and master room away from main living building. These above results show that our traditional house are much more emphasized seeking visual privacy of rooms than aural privacy.

수음실 잔향시간 변화에 따른 중량 충격음 레벨 특성 - 실험실 환경을 중심으로 - (Floor Impact Sound Pressure Level Characteristics by the Change of Reverberation Time in Mock-up Test Rooms)

  • 정정호;이병권;연준오;전진용
    • 한국소음진동공학회논문집
    • /
    • 제24권4호
    • /
    • pp.339-347
    • /
    • 2014
  • Floor impact sound in high-rise apartment building became one of social problems. A lot of civil complaints on floor impact sound occur continuously and the number of disputes between neighbors in small and aged apartment buildings is increasing. Interests on heavy-weight impact sound pressure level measurement and evaluation method is increased. Previous study reported that heavy-weight impact sound level was changed by the sound field condition of receiving reverberation chamber. In this study, heavy-weight impact sound pressure level change by the receiving sound field condition was measured in standard test facility and mock-up test room. These two experimental conditions were designed to simulate averaged living room of common apartment units. By the change of sound absorption power in receiving room, heavy-weight impact sound pressure level in most of frequency bands were changed in standard test facility and mock-up room. Normalized maximum sound pressure level regulated in ISO 16032 showed wider range of heavy/soft impact sound pressure level. Heavy/soft impact sound pressure level change was became smaller by the application of standardized maximum sound pressure level and ISO/CD 10140-3 Amd 2 method. In the case of standardized maximum sound pressure level, absolute sound pressure level changed. From these results, receiving sound field correction method regulated in ISO/CD 10140-3 Amd 2 is needed for the precision measurement and evaluation of heavy-weight impact sound.