교회 건축물의 실내음향 특성에 관한 연구 (A Study on the Room Acoustics in Churches)

  • 주진수
    • 소음진동
    • /
    • 제9권4호
    • /
    • pp.681-686
    • /
    • 1999
  • In a church, speech intelligibility is very important together with the reverberance for musical activities. In order to obtain the primary data of a acoustical design for churches records were refereed and churches were measured in Europe and Japan. And in the base of measurements, those were judged by subjective hearing test. As some results, it has been found that the room acoustics of churches were different in a country and the reverberation time was perferred two seconds for speech intelligibility. However, although personal deviations were admitted, more long echoes were preferred for the music.

  • PDF

5자유도 잔향 모델을 이용한 실내 잔향 필터 설계를 위한 조건 (Constraints for the Design of Room Reverberation Filter by Using 5-DOF Reverberation Model)

  • 김소희;김양한
    • 한국음향학회지
    • /
    • 제20권2호
    • /
    • pp.58-65
    • /
    • 2001
  • 잔향에 대한 인간의 주관적인 지각을 객관적인 수치로써 나타내는 방법으로 5자유도 잔향 모델이 제안된 바 있다[1]. 5자유도 잔향 모델은 잔향에 대한 다섯 개의 객관적인 평가량들을 이용하여 시간에 따른 음 에너지 감쇠 곡선을 근사한 것으로, 인공적으로 잔향을 합성하고자 할 때 잔향 필터의 설계 기준으로 유용하게 사용될 수 있다. 그러나 이로부터 구현할 수 있는 잔향 필터는 이론적으로 무한히 많을 수 있고, 따라서 인간이 듣기에 부자연스러운 합성음을 만들어 내는 경우도 존재할 수 있다. 본 논문은 5자유도 잔향 모델의 한계를 시간 영역과 주파수 영역으로 나누어 살펴보고 잔향 모델, 즉 원하는 잔향 조건이 주어졌을 때 자연스러운 잔향을 얻기 위해 필요한 필터 설계 기준을 실제 청음 실험을 통하여 제시하고 있다.

  • PDF

소형 잔향실의 확산 음장 보정 계수 측정 연구 (The Study on Correction Factor of a Small Scale Reverberation Chamber to Estimate Transmission Loss)

  • 김태민;김다래;김정태
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.960-965
    • /
    • 2014
  • Transmission loss of specimen is calculated by measuring energy of incident and transmission and using reverberant room of large size. But normal measurement of transmission loss has trouble because it is actually demanded that large area and specimen of certain size is satisfied with condition of diffused sound field. Especially, in case of mechanical component, interested frequency band is mid-frequency band between 500 ~ 2k Hz, and it is used to be available to minimize a reverberation chamber under conditions satisfying acoustic one because production of specimen for transmission loss measurement has limit. But, as in semi-reverberation room, it is difficult to satisfy condition of diffuse sound field and modification factor is applied to complement that. Correction factor when measuring transmission loss using semi-reverberation chamber is required accuracy because it works as main factor determining reliability of reuslts on transmission loss. In this study, it is analyzed that an effect on correction factor based on varying materials and sizes of specimens in order to deduction of it. Also It is confirmed that applied by elicited correction factor with actual railway vehicle's floor has reliability.

  • PDF

축소잔향실의 저주파수 확산음장 형성 방법에 대한 연구 (Study on method of build up low-frequency diffuse sound field in a scaled reverberation chamber)

  • 강준구;강현주;김상렬;최종수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.61-64
    • /
    • 2007
  • This study is dealt with a method to enhance low-frequency diffuse sound field in a scaled reverberation chamber. Because scaled reverberation chamber has not enough room volume, as a result, it shows a few room modes. So it is not build up low-frequency diffuse sound field. A Helmholtz resonator's arrangement is used to improve spatial uniformity of sound pressure at low frequency. The spatial distribution of sound field has been measured before and after control. The standard deviation of sound field has decreased at 315Hz 1/3 Octave band.

  • PDF

ISO 354 (잔향실법 흡음률 측정방법)의 KS 규격화 (Korea Industrial Standardization Draft for ISO 354)

  • 정성수;국찬;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.857-860
    • /
    • 2003
  • We introduced the basic direction of revision for KS F 2805 (method for measurement of sound absorption coefficient in a reverberation room). It is fundamentally equal to ISO 354 (measurement of sound absorption in a reverberation room) which was state of ISO/FDIS 354. Two main points were strongly reviewed. First, the sound absorption coefficient values for Type J test specimen mounting was investigated. Next, the reverberation time difference between the conventional method and new additional one, impulse response method were compared.

  • PDF

잔향실 성능 검증 및 향상 연구 (A Study on the Improvement of Reverberation Room's Performance)

  • 김성훈;주원호;김동해;배종국
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.171-175
    • /
    • 2006
  • Recently, two reverberation rooms were built up of 300mm thick concrete walls in non-parallel pentagonal shape to measure the sound absorption, transmission, radiation, and impact insulation of acoustical materials, panels, doors, etc. Various acoustic tests, including the sound transmission test, were carried out to investigate their acoustic performances. In order to improve the performance, several modifications on these acoustical parameters, such as the acoustic mode, the position of specimen, the formation of diffuse field, the location of sound source, and flanking transmission, have been conducted. Through a series of tests, the reverberation rooms have been effectively improved so that it could perform a variety of acoustic tests with the international standard. And then, it is expected to be very helpful in developing the low noise design technology for ships.

  • PDF

잔향시간 측정 오차의 차음손실에 대한 영향 (Effect of the measurement error of reverberation time on the STL)

  • 신성환;이정권;강현주
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 II
    • /
    • pp.1099-1103
    • /
    • 2001
  • In room acoustics, reverberation time (RT) is the most important and general factor that represents character of room or inner space. However, RT, especially in low frequency range, can have the different value according to the measuring points and methods. This study comprehends the cause of error occurring dominantly in low frequency range when RT is measured and examines that the each error of RT measured in the cabin and reverberation chamber having different properties, influences what extent on sound transmission loss (STL)

  • PDF

흡음형과 공명형 덕트 소음기의 소음저감 성능에 관한 실험적 고찰 (An Experimental Investigation on Noise Reduction Performance of the Absorption and the Resonance Type Duct Silencers)

  • 이영섭;정광섭;이동훈
    • 설비공학논문집
    • /
    • 제22권12호
    • /
    • pp.897-901
    • /
    • 2010
  • A silencer has been widely used for the purpose of suppressing the noises propagated from duct of air conditioning system. The absorption type silencer is usually applied to reduce the noise with high frequency bandwidth. On the order hand, the resonance type silencer is applied to reduce the noise with low-middle frequency bandwidth. The insertion loss of silencer is measured in the reverberation room. The cut-off frequency of reverberation room is 100 Hz. The insertion loss of absorption type silencer is more larger than that for resonance type silencer regardless of changing the flow velocity.

관내법을 이용한 흡.차음 성능 측정방법 (A measuring technology of the absorption ratio and the transmission loss using the tube method)

  • 이장명;김동률
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1998년도 춘계학술대회논문집; 용평리조트 타워콘도, 21-22 May 1998
    • /
    • pp.659-663
    • /
    • 1998
  • To measure the absorption ratio and the transmission loss of a material, a usage of the reverberation room has been popular. However, the reverberation room is expensive to build it and, sometimes, test procedure is not easy. Therefore, to get the data of absorption ratio, several possible technologies has been proposed using the tube. Among these technologies, with the analysis of the spectral density, a convenient method has been introduced to measure both the absorption ratio and transmission loss. The measured data has been compared with the results of the measurement at the reverberation room.

  • PDF

잔향실의 음압분포해석 및 계측치와의 비교 (An Analysis of Sound Pressure Distribution in a Reverberation Room and Comparisons with Measurements)

  • 김현실;김재승;강현주;김상렬
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1997년도 춘계학술대회논문집; 경주코오롱호텔; 22-23 May 1997
    • /
    • pp.669-674
    • /
    • 1997
  • A sound field in a reverberation room is analyzed by using numerical methods and the SPL distributions are compared to the measurements. In numerical predictions, the BEM is employed in the low frequency range, while sound ray tracing method is used for the high frequency range. In the BEM analysis, the surfaces of the empty reverberation room are assumed as rigid boundaries and the damping coefficients are estimated from the measured absorption coefficient. The comparisons with measurements for 100Hz shows good agreement. In the sound ray tracing analysis, the predicted energy decay are in excellent agreements with theoretical results. It is shown that the energy absorption by air damping plays an important role as frequency becomes higher.

  • PDF