A Validation Model for the Statistical Power Balance Method Using a Reverberation Chamber

  • Lee, Young Seung;Choi, Sung Woong;Park, Seung Keun
    • Journal of electromagnetic engineering and science
    • /
    • v.13 no.3
    • /
    • pp.192-194
    • /
    • 2013
  • This paper proposes a validation model using a reverberation chamber for verification of the effectiveness and accuracy of the statistical power balance (PWB) method. The PWB method treats electromagnetic (EM) field distributions in certain environments as a representative value of an "ensemble" average, so a reverberation chamber is utilized as a testing apparatus to experimentally simulate the sets of measurement field "ensemble" inside a complex environment. Measurements are performed with various test conditions for environmental loss using flat absorbers, and front and side doors of the chamber. Comparison between the PWB analysis and the measurement results shows good agreement, indicating the usefulness of this statistical analysis method for stating the electromagnetic field inside the EM zone as a representative value to general structures.

Acoustic Performance of a Scaled Reverberation Chamber (간이 잔향실의 음향성능)

  • Kang, Hyun-Ju;Kim, Bong-Kee;Kim, Jae Seung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11b
    • /
    • pp.101-104
    • /
    • 2005
  • This study presents experimental results from the performance test of a scaled reverberation chamber for measurement of sound insulation of panels. Experimental investigations were conducted in various parameters such as tunneling effect source locations, and maximum sound transmission loss. It is evident that the tunneling effect which means the variation with specimen location on the test frame gives rise to more than 3 dB deviation. One of the objective of this study that compares measured results between a real reverberation chamber and a simplified test apparatus, by using a specimen of a sandwich panel. It shows qualitatively resonable agreement from which one can find a potential to provide a design tool.

  • PDF

Measuring Scattering Coefficient in 1:10 Reverberation Chamber Using the ISO Method (ISO 방법론 및 1:10 축소잔향실을 이용한 확산률 측정)

  • 전진용;이병권;정갑철
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.252-256
    • /
    • 2001
  • Scattering of surface materials has been known as one of the most important aspects in evaluating the acoustics of concert halls are designed. One of the methods that can reduce the errors in estimating the reverberation time and other acoustic parameters through computer modeling is to calculate scattering coefficient of surface materials. However. so far, no objective and reliable methods measuring scattering coefficient has been suggested. In this situation, ISO has suggested the method of measuring the random-incidence scattering coefficient on surfaces in diffuse field, whereas AES has introduced a method on directional-incidence in free field. In this study, the scattering coefficients of five kinds of hemispheres (1.5, 2.0. 2.5. 3.0. 3.5cm) were measured by using the ISO method in 1:10 reverberation chamber. It was found that 3.0cm hemisphere has the highest scattering coefficient satisfying 95% reliability.

  • PDF

Field Uniformity Analysis of Reverberation Chamber with Asymmetric Structure (비대칭적 구조 전자파 잔향실 전자기장 균일도 해석)

  • 정삼영;이중근;이황재
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.5
    • /
    • pp.837-843
    • /
    • 2001
  • Conventional reverberation chamber has a rectangular structure including mode stirrers or mode-turned stirrers to obtain the field uniformity inside the chamber. This paper explained the way to improve the field uniformity in an asymmetric structure instead of conventional rectangular structure with right-angled planes. Two types of asymmetric structure were considered. One was an asymmetric reverberation chamber using Quadratic Residue Diffuser and the other was an asymmetric chamber with oblique enclosure including fixed Randomly Made Diffusers. The FDTD simulation method was used to analyze the field homogeneous characteristics of these asymmetric reverberation chambers.

  • PDF

Vibration Isolation System of a Large Reverberation Chamber (대형 잔향실의 방진 설계 및 검증)

  • 김영기;김홍배;이동우;우성현;문상무
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.1026-1031
    • /
    • 2003
  • A vibration isolation system fur a large reverberation chamber (1,228㎥, 1,000ton) has been installed. The reverberation chamber generates loud noise and induces high level of vibration to perform spacecraft acoustic environmental tests. The isolation system prevents vibration transfer from the chamber to enclosure buildings. This paper describes logical design process and commissioning experiments of the system. Design criteria have been induced from rigid body model of the chamber. Finite element model has been employed to select the characteristics of rubber pads. A total of 21 rubber pads have been installed between the chamber and supporting pedestals. A sand bag of 800kg was dropped on the chamber floor to measure the natural frequency of the isolation system. Absolute transmissibility has been measured while generating 145㏈ in the chamber. The natural frequency of the chamber is 10.5㎐, which is 80% of estimated value. Overall transmissibility at working frequency range (25㎐-10,000㎐) is less than -6㏈.

  • PDF

Korea Industrial Standardization Draft for ISO 354 (ISO 354 (잔향실법 흡음률 측정방법)의 KS 규격화)

  • Jung, Sung-Soo;Kook, Chan;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.857-860
    • /
    • 2003
  • We introduced the basic direction of revision for KS F 2805 (method for measurement of sound absorption coefficient in a reverberation room). It is fundamentally equal to ISO 354 (measurement of sound absorption in a reverberation room) which was state of ISO/FDIS 354. Two main points were strongly reviewed. First, the sound absorption coefficient values for Type J test specimen mounting was investigated. Next, the reverberation time difference between the conventional method and new additional one, impulse response method were compared.

  • PDF

Analysis of Reverberation Time of Outdoor Space in Apartment Complex According to the Green Wall Conditions (아파트 단지 옥외 공간에서의 녹화 조건에 따른 잔향특성 변화 분석)

  • Cho, Hyun-Min;Shin, Hye-Kyung;Sung, Yo-Han;Kim, Myung-Jun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.874-879
    • /
    • 2014
  • This study is aimed to evaluate the acoustic performances of outdoor apartment complex and to analyze acoustic performances change based on greening conditions. The object space located in Seoul, Yangcheon-gu, Sinjung-dong and classified according to type of space-form. The measurement reverberation time at 500 Hz is 0.86~1.84sec. The simulated reverberation time at 500 Hz is decreased from 1.57sec to 0.57sec in ㅁshape type of 69% treatment with greening and 1.7sec to 0.89sec in ㄷshape type of 70% treatment and 1.05sec to 0.53sec in ㄴshape type of 61.6% treatment.

  • PDF

The effect of diffusers on the measurement of sound absorption in a reverberation room (잔향실법 흡음률 측정에 미치는 확산체의 영향)

  • Han, Hee-Kab;Kim, Kyung-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1194-1197
    • /
    • 2006
  • Recently, international standard for measurement of sound absorption in a reverberation room has been amended. In the revised version, temperature, humidity and air pressure conditions are strictly restricted and also the concrete procedures are presented to reduce the differences in test results by adding inspection of diffusion, measurement uncertainty etc. In this paper, the systematic tests are conducted based on the inspection guide of diffusion defined by ISO 354 and the effects of diffusers on the measurement of sound absorption ratio are considered. As a result, we perceived that the averaged sound absorption ratio in mid and high frequency range is expected to measure around $0.05{\sim}0.1$ higher in high sound absorption material. Therefore, as for the reverberation room for measurement of sound absorption, we need to take into consideration not only the spatial standard deviation of sound pressure mandated by ISO 3741, but also, inspection regulation of diffusion showed by ISO 354.

  • PDF

A Study on the Improvement of Reverberation Room's Performance (잔향실 성능 검증 및 향상 연구)

  • Kim, Sung-Hoon;Joo, Won-Ho;Kim, Dong-Hae;Bae, Jong-Guk
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.171-175
    • /
    • 2006
  • Recently, two reverberation rooms were built up of 300mm thick concrete walls in non-parallel pentagonal shape to measure the sound absorption, transmission, radiation, and impact insulation of acoustical materials, panels, doors, etc. Various acoustic tests, including the sound transmission test, were carried out to investigate their acoustic performances. In order to improve the performance, several modifications on these acoustical parameters, such as the acoustic mode, the position of specimen, the formation of diffuse field, the location of sound source, and flanking transmission, have been conducted. Through a series of tests, the reverberation rooms have been effectively improved so that it could perform a variety of acoustic tests with the international standard. And then, it is expected to be very helpful in developing the low noise design technology for ships.

  • PDF

Comparison Study of Sound Transmission Loss in High Speed Train

  • Kim, Tae-Min;Kim, Jeung-Tae
    • International Journal of Railway
    • /
    • v.4 no.1
    • /
    • pp.19-27
    • /
    • 2011
  • Many studies for improving the railway vehicle's performance and comfort such as speed, weight and noise are currently in progress. Improving the structural characteristics of the vehicle for greater noise insulation is considered important for reducing disturbance due to noise, but measuring transmission loss entails large costs. This study explores an alternative method for estimating and measuring the railway vehicle's transmission loss that involves on applying the numerical analysis coupled with scaled reverberation chamber measurement. The transmission loss measurement using scaled reverberation chamber was performed after the compensation value was found through 1mm thickness(1t) specimen. For numerical analysis, a commercially available acoustics solver VA ONE was used. The proposed method is found to lead to transmission loss measurement comparable to the measurements based on large-scale reverberation chamber. Thus, it can be argued that a reliable method has been developed for measuring railway vehicle's transmission loss.