• Title/Summary/Keyword: retaining structures

Search Result 265, Processing Time 0.031 seconds

Behavior Analysis Using FEM for Earth Retaining Wall of Soft Rock Fracture Zone (FEM을 이용한 연암 파쇄대 지반의 흙막이 벽체 거동 분석)

  • Jang, Gi-Soo;Park, Min-Chul;Shin, Hyo-Hee;Lee, Song
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.4
    • /
    • pp.30-37
    • /
    • 2013
  • A soft rock fracture zone is an important element for rock slope or earth retaining, however stability studies of earth retaining wall have been lack. Therefore, this study is analyzed for a behavior of earth retaining wall with condition of fracture zone or no fracture zone and then a numerical analysis (Finite Element Method) was performed considering interaction with field monitoring data between ground and structures. As a result, applied horizontal displacement on retaining wall is correspond between result of numerical analysis and field monitoring data and displacement point stress distribution with fracture zone condition analyzed to be stable side but no fracture zone condition is expressed to be unstable side. The results of this study is purpose for applying safety construction as a top priority at field when designing for future.

Cooperative bearing behaviors of roadside support and surrounding rocks along gob-side

  • Tan, Yunliang;Ma, Qing;Zhao, Zenghui;Gu, Qingheng;Fan, Deyuan;Song, Shilin;Huang, Dongmei
    • Geomechanics and Engineering
    • /
    • v.18 no.4
    • /
    • pp.439-448
    • /
    • 2019
  • The bearing capacity of roadside support is the key problem in gob-side entry retaining technology. To study the cooperative bearing characteristics of the roof-roadside support-floor along the gob-side entry retaining, a mechanical model of the composite structure of the roof-roadside support-floor was first established. A method for determining the structural parameters of gob-side entry retaining was then proposed. Based on this model, adaptability analysis of roadside support was carried out. The results showed that the reasonable width of the gob-side entry roadway was inversely proportional to the mining height, and directly proportional to the bearing strength of the roof and floor. And the reasonable width of the "flexible-hard" roadside support was directly proportional to its own strength, and inversely proportional to the width of the gob-side entry retaining. When determining the position and size of the roadside support along the gob-side entry retaining, the surrounding rock environment should be fully considered. Measured results from case study also show the rationality of the model and calculation method.

Urban Excavation and Observational Method (도심지 지하굴착 및 정보화 시공)

  • Kim, Hak-Moon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.10a
    • /
    • pp.3-14
    • /
    • 2005
  • Reliable predictions of the movement of earth retaining structures and the ground adjacent to braced walls in urban excavation are often difficult due to many variable factors. The ground settlement and the damage of adjacent structures in urban excavation has been an important issue. Therefore, the stability of the adjacent structures must be secured with the excavation support and research on the protection of adjacent structure is necessary. This study showed an urban excavation case and introduce observation method for case of damage behavior in urban excavation.

  • PDF

Finite Element Analysis of Engineering Restoration of Dry Stone Wall Foundations (석조문화재 기초부의 공학적 복원을 위한 유한요소법 해석)

  • Kim, Sung-Su;Jung, Young-Hoon;Kim, Soo-Il;Lee, Kwang-Wu
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.1130-1141
    • /
    • 2010
  • Even though a number of historic structures in Korea need to be repaired, an intensive research on their engineering performance has rarely been investigated. Herein, we attempted to provide a methodological approach via the explicit finite element analysis to investigate geotechnical aspect of the performance of the dry-stone wall structures. To do so, we summarized relevant literature on the world-wide historic stone structures as well as its analysis in terms of modern geotechnical engineering. The method of the explicit finite element analysis has been briefly summarized. The numerical results on an idealized block structure show that the displacement of blocks and the distribution of earth pressure is different from the conventional theory of the retaining wall because of the discrete nature of the dry-stone wall structure.

  • PDF

A study on the Remote Control System for Measuring Gradient of temporary earth retaining structure (흙막이 가시설 구조물의 무선원격계측관리시스템에 관한 연구)

  • Woo, Jong-Yeol;Hong, Seong-Wook;Kim, Sang-Won;Seo, Yong-Chil;Shin, Chan-Ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.05b
    • /
    • pp.49-52
    • /
    • 2011
  • This study concerned with the retention structures or inverted temporary building for displacement measurement in the underground soil after drilling a vertical tilt sensor attached to the vertical distance required to maintain a real-time measurement and management in order to install the wireless measuring devices installed in the field through remote control and management program for the safety of retaining structures temporary building be found on the internet in real time temporary building the retention is to develop a safety management system. And based on this technology to monitor the future status of the various structures possible to add a variety of sensors and Life Cycle Prediction of the structure and needs to evolve into intelligent systems and wireless networks using wireless communications infrastructure systems based on expanding domestic market penetration by developing instrumentation pioneer in overseas markets as well as the activation can also be judged.

  • PDF

Calculation of Reasonable Equivalent Uniform Pressure Height and Lateral Earth Pressure Characteristics of Retaining Structures (옹벽에 작용하는 수평토압 특성 분석 및 합리적인 등가상재하중 높이 산정)

  • Lee, Kicheol;Chung, Moon-Kyung;Seo, Seunghwan;Kim, Dongwook
    • Journal of the Korean Geosynthetics Society
    • /
    • v.18 no.4
    • /
    • pp.139-149
    • /
    • 2019
  • For retaining wall designs, horizontal earth pressure induced by traffic loads over the walls is calculated based on equivalent uniform pressure height. The AASHTO LRFD design standards propose equivalent uniform pressure height of traffic loads; however, the equivalent uniform pressure height is calibrated using the US standard trucks. As the domestic standard trucks are different from the US standard trucks, in this study, new domestic equivalent uniform pressure height is proposed using the Boussinesq theory varying vehicle directions, Poisson's ratios of pavement layers, and retaining wall height. The proposed equivalent uniform pressure heights are generally higher than those proposed by the AASHTO design standards because the axle loads and their densities of two domestic standard trucks are higher than those of the US standard trucks. The most highest equivalent uniform pressure height was found for traffic direction perpendicular to longitudinal direction of retaining wall.

Displacement Comparison of a Braced Retaining Wall by Elasto-Plastic Analysis Program (탄소성 해석프로그램에 의한 버팀지지 흙막이벽의 변위 비교)

  • 신방웅;김상수;오세욱;김동신
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.03b
    • /
    • pp.395-402
    • /
    • 2000
  • Recently, the deep excavations have been peformed to utilize the under ground space. As the ground excavation is deeper, the damage of the adjacent structure and the ground occurs frequently. The analysis of the retaining structures is necessary to the safety of the excavation works. There are many methods such as elasto-plastic, FEM, and FDM to analyze the displacement of the retaining structure. The elasto-plastic method is generally used in practice. In this thesis, GEBA-1 program by the Nakamura-Nakajawa elasto-plastic method was developed. The program for Windows was used the Visual Basic 6.0, and the Main of the program consists of three subroutines, SUB1, SUB2, and SUB3. The lateral displacement of the wall was analyzed by the developed program GEBA-1, SUNEX, and EXCAD, and compared with the measured displacement by the Inclinometer(at three excavation work sites). The excavation method of each site is braced retaining wall using H-pile. Each excavation depth is 14m, 14m, or 8.2m. The results of the analyses are the followings ① In the multi-layer soil, the lateral displacement by the GEBA-1 and EXCAD which is considering the distribution of the strut load is equal to the measured displacement. Elasto-plasto programs can't consider the change of the ground water in clay. Therefore, the analysis displacement was expected only 20% of the measured wall displacement. ③ At the final excavation step, the maximum lateral displacement of analysis and field occurred 7∼18m at the 85∼92% of the excavation depth. ④ The maximum lateral displacement in clay, as 50mm, occurred on the ground surface.

  • PDF

Review of the Nomenclature of the Retaining Ligaments of the Cheek: Frequently Confused Terminology

  • Seo, Yeui Seok;Song, Jennifer Kim;Oh, Tae Suk;Kwon, Seong Ihl;Tansatit, Tanvaa;Lee, Joo Heon
    • Archives of Plastic Surgery
    • /
    • v.44 no.4
    • /
    • pp.266-275
    • /
    • 2017
  • Since the time of its inception within facial anatomy, wide variability in the terminology as well as the location and extent of retaining ligaments has resulted in confusion over nomenclature. Confusion over nomenclature also arises with regard to the subcutaneous ligamentous attachments, and in the anatomic location and extent described, particularly for zygomatic and masseteric ligaments. Certain historical terms-McGregor's patch, the platysma auricular ligament, parotid cutaneous ligament, platysma auricular fascia, temporoparotid fasica (Lore's fascia), anterior platysma-cutaneous ligament, and platysma cutaneous ligament-delineate retaining ligaments of related anatomic structures that have been conceptualized in various ways. Confusion around the masseteric cutaneous ligaments arises from inconsistencies in their reported locations in the literature because the size and location of the parotid gland varies so much, and this affects the relationship between the parotid gland and the fascia of the masseter muscle. For the zygomatic ligaments, there is disagreement over how far they extend, with descriptions varying over whether they extend medially beyond the zygomaticus minor muscle. Even the 'main' zygomatic ligament's denotation may vary depending on which subcutaneous plane is used as a reference for naming it. Recent popularity in procedures using threads or injectables has required not only an accurate understanding of the nomenclature of retaining ligaments, but also of their location and extent. The authors have here summarized each retaining ligament with a survey of the different nomenclature that has been introduced by different authors within the most commonly cited published papers.

Analysis of the Segmental Reinforced Retaining Wall Behavior by Field Monitoring (현장계측을 통한 블럭식 보강토 옹벽의 거동분석)

  • Shin, Eun Chul;Lee, Chang-Seup
    • Journal of the Korean Geosynthetics Society
    • /
    • v.3 no.1
    • /
    • pp.3-15
    • /
    • 2004
  • Geogrid reinforced soil structures with segmental block facing have been increased since 1990's, because of the convenience of installation and the flexible appearance. In this paper, the behavior of the segmental reinforced retaining wall was analysed with the results of field monitoring. The height and length of reinforced wall are 12m and 25m, respectively. The field measurement equipments are horizontal and vertical earth pressure cells, settlement plate, strain gauge, inclinometer, and displacement pin. Based on the field monitoring, the horizontal earth pressure was approximately 0.3times higher than that of the theoretical method and the maximum tensile strength of reinforcement was 26.2kN/m. The displacement of facing wall was 23mm at the point of 7.1m height of the wall and toward the wall facing. The results of the study indicate that the segmental reinforced retaining wall is in a stable condition because of good compaction & reinforcement effects, and long period of construction time. Finally, the computer program of SRWall is very useful tool to design the segmental reinforced retaining wall.

  • PDF

Analysis of the Impact on Prediction Models Based on Data Scaling and Data Splitting Methods - For Retaining Walls with Ground Anchors Installed (데이터 스케일링과 분할 방식에 따른 예측모델의 영향 분석 - 그라운드 앵커가 설치된 흙막이 벽체 대상)

  • Jun Woo Shin;Heui Soo Han
    • The Journal of Engineering Geology
    • /
    • v.33 no.4
    • /
    • pp.639-655
    • /
    • 2023
  • Recently, there has been a growing demand for underground space, leading to the utilization of earth retaining walls for deep excavations. Earth retaining walls are structures that are susceptible to displacement, and their measurement and management are carried out in accordance with the standards established by the Ministry of Land, Infrastructure, and Transport. However, managing displacement through measurement can be considered similar to post-processing. Therefore, in this study, we not only predicted the horizontal displacement of a retaining wall with ground anchors installed using machine learning, but also analyzed the impact of the prediction model based on data scaling and data splitting methods while learning measurement data using machine learning. Custom splitting was the most suitable method for learning and outputting measurement data. Data scaling demonstrated excellent performance, with an error within 1 and an R-squared value of 0.77 when the anchor tensile force and water pressure were standardized. Additionally, it predicted a negative displacement compared to a model that without scaling.