• 제목/요약/키워드: restorative material

검색결과 406건 처리시간 0.025초

광중합형 구치부 수복재료의 중합수축량과 중합수축력 (AMOUNT OF POLYMERIZATION SHRINKAGE AND SHRINKAGE STRESS IN COMPOSITES AND COMPOMERS FOR POSTERIOR RESTORATION)

  • 박성호;이순영;조용식;김수선;이창재;김영주;이봉희;이광성;노병덕
    • Restorative Dentistry and Endodontics
    • /
    • 제28권4호
    • /
    • pp.348-353
    • /
    • 2003
  • The purpose of present study was to evaluate the polymerization shrinkage stress and amount of linear shrinkage of composites and compomers for posterior restoration. For this purpose, linear polymerization shrinkage and polymerization stress were measured. For linear polymerization shrinklage and polymerization stress measurement, custom made Linometer (R&B, Daejon, Korea) and Stress measuring machine was used (R&B, Daejon, Korea). Compositers and compomers were evaluated: Dyract AP (Dentsply Detrey, Gumbh. German) Z100 (3M Dental Products, St. Paul. USA) Surefil (Dentsply Caulk, Milford, USA) Pyramid (Bisco, Schaumburg, USA) Synergy Compact (Coltene, Altstatten, Switzerland), Heliomolar (Vivadent/Ivoclar, Liechtenstein), and Compoglass (Vivadent Ivoclar/Liechtenstein) were used. 15 measurements were made for each material. Linear polymerization shrinkage or polymerization stress for each material was compared with one way ANOVA with Tukey at 95% levels of confidence. For linear shrinkage: Heliomolar, Surefil

불소의 농도와 Seed Material이 Crystal Growth에 미치는 영향 (EFFECTS OF FLUORIDE CONCENTRATION AND SEED MATERIAL ON SEEDED CRYSTAL GROWTH)

  • 오승연;정일영;금기연;이찬영
    • Restorative Dentistry and Endodontics
    • /
    • 제22권2호
    • /
    • pp.560-574
    • /
    • 1997
  • The present study was undertaken to investigate the crystal growth onto human enamel mineral and synthetic hydroxyapatite(HA) seeds in media resembling the enamel fluid composition. Effects of fluoride at high concentrations on the precipitation were also examined in a bench-top crystal growth model adopting a miniaturized reaction column. The Ca, P and F concentrations and pH values of the inlet and outlet solutions were determined. The recovered solid samples were weighed to assess the amount of minerals precipitated during the experimental period, and finally viewed under a scanning electron microscope. Remarkable findings were that 1) both biological and synthetic seeds with the same total surface areas yielded similar amounts of crystal growth, 2) the amount of crystal growth was accelerated in a manner depending on fluoride concentrations in the media, 3) SEM observations disclosed that without the addition of fluoride, precipitation of thin, plate-like OCP crystals became prominent, but by increasing the fluoride concentration(beyond 1ppm F), rod-like crystals having a pointed edge were most frequently observed, without any evidence for precipitation of the plate-like crystals. Furthermore, the dimension of rod-like crystals was increased in proportion to fluoride concentrations, 4) there was no difference in the morphological feature of precipitated mineral phase upon seeding between human enamel seed and synthetic HA seed. The overall results support the view that the seeded crystal growth model is of value to gain insight into the mechanism of enamel crystal growth under fluoride regimens.

  • PDF

Retention of BioAggregate and MTA as coronal plugs after intracanal medication for regenerative endodontic procedures: an ex vivo study

  • Amin, Suzan Abdul Wanees;Gawdat, Shaimaa Ismail
    • Restorative Dentistry and Endodontics
    • /
    • 제43권3호
    • /
    • pp.18.1-18.12
    • /
    • 2018
  • Objectives: This study compared the retention of BioAggregate (BA; Innovative BioCeramix) and mineral trioxide aggregate (MTA; Angelus) as coronal plugs after applying different intracanal medications (ICMs) used in regenerative endodontic. Materials and Methods: One-hundred human maxillary central incisors were used. The canals were enlarged to a diameter of 1.7 mm. Specimens were divided into 5 groups (n = 20) according to the ICM used: calcium hydroxide (CH), 2% chlorhexidine (CHX), triple-antibiotic paste (TAP), double-antibiotic paste (DAP), and no ICM (control; CON). After 3 weeks of application, ICMs were removed and BA or MTA were placed as the plug material (n = 10). The push-out bond strength and the mode of failure were assessed. The data were analyzed using 2-way analysis of variance, the Tukey's test, and the ${\chi}^2$ test; p values < 0.05 indicated statistical significance. Results: The type of ICM and the type of plug material significantly affected bond strength (p < 0.01). Regardless of the type of ICM, BA showed a lower bond strength than MTA (p < 0.05). For MTA, CH showed a higher bond strength than CON, TAP and DAP; CHX showed a higher bond strength than DAP (p < 0.01). For BA, CH showed a higher bond strength than DAP (p < 0.05). The mode of failure was predominantly cohesive for BA (p < 0.05). Conclusions: MTA may show better retention than BA. The mode of bond failure with BA can be predominantly cohesive. BA retention may be less affected by ICM type than MTA retention.

치아용 유리침윤 알루미나에서 파괴거동에 미치는 미세구조 및 어닐링 효과 (Microstructure and annealing effect on fracture behavior in the dental glass-infiltrated alumina)

  • 정종원;최성철
    • 한국결정성장학회지
    • /
    • 제10권4호
    • /
    • pp.330-336
    • /
    • 2000
  • 치아 대체용 재료로서 응용되고있는 유리침윤 알루미나 복합체에서 미세구조 및 압입응력이 파괴거동에 미치는 영향을 헤르찌안 및 비커스 압입시험을 사용하여 조사하였다. 유리침윤 알루미나의 압입 응력벽형 거동은 높은 하중에서 약간의 비선형성을 보이는 준소성과 전형적인 헤르찌안 콘 균열을 동시에 나타내고 있으며, 계면 접합 시험편을 이용한 표면아래의 손상에서도 이를 확인할 수 있었다. 일차 성형체의 압입 응력-변형 곡선은 기공형태 및 입자크기에 크게 의존하고있지만, 유리침윤 공정이후 제조된 복합체에서는 큰 차이를 보이지 않았다. 복합체의 파괴는 준소성 변형 영역에서 일어나고 있으며, 헤르찌안 압입응력장이 재료손상 및 파괴거동에 미치는 영향을 이론적으로 조사하여 압입응력이 재료의 손상에 미치는 영향이 매우 크다는 것을 알았다. 그러나 압입시험후 행해진 어닐링 공정은 알루미나의 파괴거동에 변화를 가져왔으며, 이는 어닐링 공정을 통해 재료가 받은 응력장이 치료되었음을 알 수 있었다.

  • PDF

A STUDY ON SURFACE OF VARIOUS ABUTMENT SCREWS

  • Park Chan-Ik;Chung Chae-Heon;Choi Han-Cheol
    • 대한치과보철학회지
    • /
    • 제41권3호
    • /
    • pp.351-359
    • /
    • 2003
  • Statement of problem: Regardless of any restoration, most of case, we used in screw connection between abutment and implant. For this reason, implant screw loosening has been remained problem in restorative practices. Purpose: The purpose of this study was to compare surface of coated/plated screw with titanium and gold alloy screw and to evaluate physical property of coated/plated material after scratch test in FESEM investigation Material and methods: GoldTite, titanium screw provided by 3i (Implant Innovation, USA) and TorqTite, titanium screw by Steri-Oss (Nobel Biocare, USA) and gold screw, titanium screw by AVANA (Osstem Implant, korea) - were selected for this study. Each abutment screw surface was observed at 100 times, and then screw crest, root, and slope were done more detailed numerical value, at 1000 times with FESEM. A micro-diamond needle was also prepared for the scratch test. Each abutment screw was fixed, micro-diamond scratch the surface of head region was made at constant load and then was observed central region and periphery of fine trace through 1000 times with FESEM. Results: The surface of GoldTite was smoother than that of other kinds of screw and had abundant ductility and malleability compared with titanium and gold screw. The scratch test also showed that teflon particles were exfoliated easily in screw coated with teflon. Titanium screw had a rough surface and low ductility. Conclusion: It was recommended that the clinical use of gold-plated screw would prevent a screw from loosening. CLINICAL IMPLICATIONS Clinical use of gold-plated screw would prevent a screw from loosening because it had abundant ductility and malleability compared with titanium and gold screw.

가시광선과 아르곤 레이저에 의해 중합된 글라스 아이오노머와 레진 수복물 주변 법랑질의 항우식 효과에 관한 비교 연구 (A COMPARATIVE STUDY ON THE ANTICARIOGENECITY OF ENAMEL SURFACE ADJACENT TO GLASS IONOMER AND RESIN RESTORATION POLYMERIZED BY VISIBLE LIGHT AND ARGON LASER)

  • 유병규;김종수;김용기
    • 대한소아치과학회지
    • /
    • 제25권1호
    • /
    • pp.62-75
    • /
    • 1998
  • The main purpose of this study was to compare the anticariogenecity of glass ionomer restorative material polymerized by argon laser versus visible light, The results from the present study can be summarized as follows; 1. Under the polarized light microscope, the specimens of laser-cured group showed the shallower lesion body than that of visible-light cured group, both in the stage of lesion initiation and progression. 2. Glass ionomer material cured by visible light showed shallower body of lesion than that of composite resin cured by argon laser at the stage of lesion progression(p<0.05). It was suggested fluoride released from the glass ionomer might have the additive anticariogenic effect. 3. Statistical difference between groups on depth of lesion body was evident after lesion progression (p<0.05). It was suggested that anticariogenic effect by argon laser was more effective at the stage of lesion progression than the lesion initiation. 4. The increment of lesion body during progression was highest in group IV (p<0.05). 5. Based upon the above-mentioned results of this study, it can be concluded that the advantage of anticariogenic effect and short curing time of argon laser in glass ionomer polymerization should be considered in children and adolescents whose caries activity is relatively higher.

  • PDF

Cytotoxicity of newly developed pozzolan cement and other root-end filling materials on human periodontal ligament cell

  • Song, Minju;Yoon, Tae-Sun;Kim, Sue-Youn;Kim, Euiseong
    • Restorative Dentistry and Endodontics
    • /
    • 제39권1호
    • /
    • pp.39-44
    • /
    • 2014
  • Objectives: The purpose of this study was to evaluate in vitro cytotoxicity of the pozzolan cement and other root-end filling materials using human periodontal ligament cell. Materials and Methods: Endocem (Maruchi), white ProRoot MTA (Dentsply), white Angelus MTA (Angelus), and Super EBA (Bosworth Co.) were tested after set completely in an incubator at $37^{\circ}C$ for 7 days, Endocem was tested in two ways: 1) immediately after mixing (fresh specimens) and 2) after setting completely like other experimental materials. The methods for assessment included light microscopic examination, cell counting and WST-1 assay on human periodontal ligament cell. Results: In the results of microscopic examination and cell counting, Super EBA showed significantly lower viable cell than any other groups (p < 0.05). As the results of WST-1 assay, compared with untreated control group, there was no significant cell viability of the Endocem group. However, the fresh mixed Endocem group had significantly less cell viability. The cells exposed to ProRoot MTA and Angelus MTA showed the highest viability, whereas the cells exposed to Super EBA displayed the lowest viability (p < 0.05). Conclusions: The cytotoxicity of the pozzolan cement (Endocem) was comparable with ProRoot MTA and Angelus MTA. Considering the difficult manipulation and long setting time of ProRoot MTA and Angelus MTA, Endocem can be used as the alternative of retrofilling material.

Fracture resistance of upper central incisors restored with different posts and cores

  • Rezaei Dastjerdi, Maryam;Amirian Chaijan, Kamran;Tavanafar, Saeid
    • Restorative Dentistry and Endodontics
    • /
    • 제40권3호
    • /
    • pp.229-235
    • /
    • 2015
  • Objectives: To determine and compare the fracture resistance of endodontically treated maxillary central incisors restored with different posts and cores. Materials and Methods: Forty-eight upper central incisors were randomly divided into four groups: cast post and core (group 1), fiber-reinforced composite (FRC) post and composite core (group 2), composite post and core (group 3), and controls (group 4). Mesio-distal and bucco-lingual dimensions at 7 and 14 mm from the apex were compared to ensure standardization among the groups. Twelve teeth were prepared for crown restoration (group 4). Teeth in other groups were endodontically treated, decoronated at 14 mm from the apex, and prepared for posts and cores. Resin-based materials were used for cementation in groups 1 and 2. In group 3, composite was used directly to fill the post space and for core build-up. All samples were restored by standard metal crowns using glass ionomer cement, mounted at $135^{\circ}$ vertical angle, subjected to thermo-mechanical aging, and then fractured using a universal testing machine. Kruskal-Wallis and Mann-Whitney U tests were used to analyze the data. Results: Fracture resistance of the groups was as follows: Control (group 4) > cast post and core (group 1) > fiber post and composite core (group 2) > composite post and core (group 3). All samples in groups 2 and 3 fractured in restorable patterns, whereas most (58%) in group 1 were non-restorable. Conclusions: Within the limitations of this study, FRC posts showed acceptable fracture resistance with favorable fracture patterns for reconstruction of upper central incisors.

분광광도법을 사용한 수종 역충전재의 근단부 폐쇄효과에 관한 연구 (SPECTROPHOTOMETRIC EVALUATION OF SEALING EFFECTS OF SEVERAL ROOT-END FILLING MATERIALS)

  • 이진규;박상진;최경규;최기운
    • Restorative Dentistry and Endodontics
    • /
    • 제28권6호
    • /
    • pp.449-456
    • /
    • 2003
  • The purpose of this study is to evaluate the sealing effect of several root-end filling materials using spectrophotometric analysis. 180 single root teeth with one canal were instrumented and canal filled. Root resected and root end preparation was made. Teeth were randomly classified to S experimental group(MTA, EBA, IRM, TCP, ZOE) and 1 control group according to root-end filling material MTA group used PRO ROOT MT A, EBA group used Super EBA. TCP group used NEW APATITE LINER TYPE II main component of which is ${\alpha}-tricalcium$ phosphate (TCP). According to manufacture's instruction experimental material was mixed and retrfilled. After 2% methylene blue solution penetration absorbance for each test sample was measured with spectrophotometer (JASCO UV-530, Japan). The mean absorbance of control and experimental group was as follows; MTA: 0.092, IRM: 0.226, Super EBA: 0.255, ZOE: 0.374, Control: 0.425, TCP: 0.501 and the result analyzed by Turkey test at P=0.05 level. Conclusions of this study are as follows; 1. The absorbance increase in following sequence MTA, IRM, Super EBA, ZOE, Control. TCP. 2. MTA showed the least leakage but was not significant with IRM or Super EBA and was significant with control or TCP(p<0.05). 3. TCP had the most leakage and was not significant with control group.

수종 불소함유 이장용 시멘트의 불소 유리량과 상아질로의 불소흡착정도 (THE IN VITRO STUDY ON FLUORIDE RELEASE AND FLUORIDE UPTAKE TO DENTIN FROM FLUORIDE CONTAINING LINER / BASE CEMENTS)

  • 고효지;정현주;오원만
    • Restorative Dentistry and Endodontics
    • /
    • 제18권1호
    • /
    • pp.27-37
    • /
    • 1993
  • The purpose of this study was to determine the fluroide release levels of new fluoride-containing liner/base cements and the fluoride uptake by dentin surfaces. Ten specimens of each brand (Fuji ionomer Type III, Fuji Lining LC, Timeline, Vitrebond and XR ionomer) were made, polymerized and placed in fluoride-free distilled water at $37^{\circ}C$, 100% relative humidity for 24 hours. The extracting solution of specimen was exchanged and fluoride release was measured daily for the 30 days. For fluoride uptake study, twenty-five extracted human lower molars were sectioned longitudinally in the mesiodistal direction with a diamond disc. Five teeth were filled with each material and then stored at $37^{\circ}C$, 100% humidity for 4 weeks. Fluoride uptake by dentin from the test materials was evaluated using electron probe micro X-ray analyzer. The following results were obtained : 1. The amounts of fluoride release showed no significant difference between Fuji ionomer Type III and Fuji Lining LC, but showed significant difference between other groups. XR ionomer released significantly greater fluoride than any other group(P<.001). 2. All the materials have a burst effect which more fluoride released in then first 3 day and showed significant decrease over the test period (P<0.001). 3. XR ionomer group showed fluoride penetration to approximately $50{\mu}m$ deep in dentin. But other material groups showed very little fluoride uptake by dentin.

  • PDF