• Title/Summary/Keyword: restorative material

Search Result 406, Processing Time 0.022 seconds

A COMPARISON OF THE BOND STRENGTHS BETWEEN SOME CEMENTS AND STAINLESS STEEL MATERIAL (Stainless steel crown을 위한 수종 시멘트의 접착력 비교)

  • Kim, Hong-Ryoul;Jeong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.3
    • /
    • pp.528-537
    • /
    • 1999
  • The purpose of this study was to analyze and compare the bond strengths between stainless steel plate and zinc phosphate cement, polycarboxylate cement and glass ionomer cement, which are frequently used for cementation of stainless steel crowns. Three cementing materials were glued to the poles standing above stainless steel plate, bovine teeth, light cured glass ionomer restorative material and amalgam. And the tensile bond strengths between them were measured with universal testing machine and the results were statistically processed using ANOVA and Student t-test. The obtained results were as follows : 1. On stainless steel plate, glass ionomer cement and polycarboxylate cement showed higher tensile bond strengths compared to zinc phosphate cement, with no significant difference between the former two. 2. On the surface of bovine teeth and glass ionomer restorative material, glass ionomer cement showed highest bond strength, followed by polycarboxylate cement and zinc phosphate cement in order. 3. For amalgam restoration, polycarboxylate cement and glass ionomer cement showed higher tensile bond strengths than zinc phosphate cement, with no significant difference between the former two.

  • PDF

COMPARATIVE STUDY ON THE FLUORIDE RELEASE AND COMPRESSIVE STRENGTH OF SEVERAL F-CONTAINING RESTORATIVE MATERIALS (수종의 불소 함유 수복재의 불소 유리 및 압축 강도에 관한 연구)

  • Park, Jee-Young;Kim, Jong-Soo;Kim, Seung-Oh
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.3
    • /
    • pp.469-476
    • /
    • 2008
  • This study was performed to compare the fluoride release pattern and compressive strength of recently developed resin-modified glass ionomers($Ketac^{TM}$ N 100 and Fuji Fil LC) with those of conventional glass ionomer restorative material(Fuji II LC). Fifteen sample discs(6 mm diameter and 1 mm height) were prepared for each tested material. The fluoride release was measured by pH/ISE meter(750P, Istek, Korea) for 31 days. For compressive strength experiment, fifteen cylindrical specimens were prepared for each tested material. Each specimen was submitted to compressive strength testing in an universal testing machine(Kyung-sung Testing Machine Co., Korea) at crosshead speed of 5.0mm/min until failure. The results can be summarized as follows; 1. Fuji Fil LC released the highest amount of fluoride, followed by Fuji II LC and $Ketac^{TM}$ N 100(p<0.05). 2. The compressive strength of Fuji Fil LC was the lowest(p<0.05). However, no significant difference was found from Fuji II LC and $Ketac^{TM}$ N 100(p>0.05). By considering the above results, careful case selection and accurate clinical application is recommended when using $Ketac^{TM}$ N 100 and Fuji Fil LC.

  • PDF

Comparative color and surface parameters of current esthetic restorative CAD/CAM materials

  • Egilmez, Ferhan;Ergun, Gulfem;Cekic-Nagas, Isil;Vallittu, Pekka Kalevi;Lassila, Lippo Veli Juhana
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.1
    • /
    • pp.32-42
    • /
    • 2018
  • PURPOSE. The purpose of this study was to derive and compare the inherent color (hue angle, chroma), translucency ($TP_{SCI}$), surface gloss (${\Delta}E^*_{SCE-SCI}$), and surface roughness ($R_a$) amongst selected shades and brands of three hybrid CAD/CAM blocks [GC Cerasmart (CS); Lava Ultimate (LU); Vita Enamic (VE)]. MATERIALS AND METHODS. The specimens (N = 225) were prepared into square-shaped ($12{\times}12mm^2$) with different thicknesses and shades. The measurements of color, translucency, and surface gloss were performed by a reflection spectrophotometer. The surface roughness and surface topography were assessed by white light interferometry. RESULTS. Results revealed that hue and chroma values were influenced by the material type, material shade, and material thickness (P < .001). The order of hue angle amongst the materials was LU > CS > VE, whereas the order of chroma was VE > CS > LU. $TP_{SCI}$ results demonstrated a significant difference in terms of material types and material thicknesses ($P{\leq}.001$). $TP_{SCI}$ values of the tested materials were ordered as LU > CS > VE. ${\Delta}E^*_{SCE-SCI}$ and $R_a$ results were significantly varied amongst the materials (P < .001) and amongst the shades (P < .05). The order of ${\Delta}E^*_{SCE-SCI}$ amongst the materials were as follows $LU>VE{\geq}CS$, whereas the order of $R_a$ was $CS{\geq}VE>LU$. CONCLUSION. Nano-ceramic and polymer-infiltrated-feldspathic ceramic-network CAD/CAM materials exhibited different optical, inherent color and surface parameters.

A SCANNING ELECTRON MICROSCOPIC STUDY ON THE ADAPTATION OF ROOT CANAL FILLING MATERIAL TO ROOT CANAL WALL WITH AND WITHOUT SMEAR LAYER (Gutta percha 충전시 도말층 유무에 따른 근관벽과의 접합도에 관한 주사전자현미경적 연구)

  • Moon, Joo-Hoon;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.17 no.2
    • /
    • pp.365-382
    • /
    • 1992
  • The purpose of this study was to evaluate the adaptation of filling material to the dentinal walls of root canals with and without smear layer. Fifty extracted upper and lower anterior teeth were selected, and the root canals were instrumented with K - files 1mm short of the apical foramen by step - back method. The teeth were randomly divided into two groups of 25 each : in the group I, smear layers were not removed, and in the group II, smear layers were removed by 15% EDTA solution. Again the two groups 25 teeth were randomly divided into unfilled contol group and filling groups(lateral, ultrasonic, ULTRAFIL, McSpadden compaction group). Upon completion of root canal filling, the teeth were grooved on the both the labial and lingual surfaces and then split with mallet and chisel. Each specimens were examined with JSM - 840 Scanning Electron Microscope (JEOL., Japan). The results were as follows : 1. In the contol group, dentinal tubules of group I couldn't be distinguished in the canal wall, but those of group II appeared to be open and patent. 2. In the filling groups of group I, the tubular penetration of the sealer or gutta percha couldn't be seen, but in the filling groups of group II, it could be seen except McSpadden compaction group. 3. In the filling groups, ULTRAFIL group showed the best adaptation of filling material to root canal wall among the group I, and lateral and ultrasonic condensation group showed the best adaptation of filling material among the group II. McSpadden compaction group showed the worst adaptation in group I, II. 4. Generally, the group II showed better adapation of filling material to root canal wall than the group I.

  • PDF

AN EXPERIMENTAL STUDY ON THE EFFECT OF VARIOUS HYDROXIDES UPON THE PULP IN DOGS' TEETH (수종수산화물(數種水酸化物)이 치수조직(齒髓組織)에 미치는 영향(影響)에 관(關)한 실험적연구(實驗的硏究))

  • Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.1 no.1
    • /
    • pp.26-32
    • /
    • 1975
  • After a vital pulpotomy in dogs' teeth, the responses of the remaining pulp tissue under hydroxides (calcium hydroxide, magnesium hydroxide, aluminium hydroxide and zinc hydroxide) were studied histologically. The class V cavities were prepared on the teeth and the pulp was amputated. Each hydroxide was placed over the amputated tissue and the cavity was sealed with zinc oxide eugenol cement. Animals were sacrificed after 3 days, 1, 2, and 3 weeks following the operation. The teeth were decalcified, sectioned and stained with hematoxylin and eosin. Microscopic examination reveals as follows; 1. Calcium hydroxide: Inflammatory change was seen in the superficial portion of the remaining pulp tissue at the 3rd day and 1st week. The incompleted calicified material began to be deposited from the canal wall at the 2nd week, and the advanced calcified material was seen at the 3rd week. 2. Magnesium hydroxide: Severe inflammatory change was seen in the superficial portion of the remaining pulp from the 3rd day and the 1st week samples. Inflammatory change was decreased at the 2nd week and the slight calcified material was deposited from the root canal at the 3rd week. 3. Aluminium hydroxide: Severe inflammatory changes were seen in the remaining pulp tissue, the blood vessel was dilated, and the odontoblasts were destroyed at the 3rd day and 1st week. The fibrous degeneration spread to the apex at the 2nd week. There was no evidence of newly formed odontoblasts or deposition of calcified material underneath aluminium hydroxide. 4. Zinc hydroxide: The micrscopic picture was destructive. A thick necrotic layer was found under the amputated surface at the 3rd day and 1st week. Granulation tissue formation as well as chronic inflammatory changes extended to the apical area in the pulp tissue. Also there were no sign of odontoblastic formation or calcified material at the 2nd and 3rd week.

  • PDF

THE EFFECTS OF THERMAL STIMULI TO THE FILLED TOOTH STRUCTURE (온도자극이 충전된 치질에 미치는 영향)

  • Baik, Byeong-Ju;Roh, Yong-Kwan;Lee, Young-Su;Yang, Jeong-Suk;Kim, Jae-Gon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.2
    • /
    • pp.339-349
    • /
    • 1999
  • The dental structure substituted by restorative materials may produce discomfort resulting from hot or cold stimuli. To investigate the effects of this stimuli on the human teeth, thermal analysis was carried out by calculation of general heat conduction equation in a modeled tooth using numerical method. The method has been applied to axisymmetric and two-dimensional model, analyzing the effects of constant temperature $4^{\circ}C\;and\;60^{\circ}C$. That thermal shock was provided for 2 seconds and 4 seconds, respectively and recovered to normal condition of $20^{\circ}C$ until 10 seconds. The thermal behavior of tooth covered with a crown of gold or stainless steel was compared with that of tooth without crown. At the same time, the effects of restorative materials(amalgam, gold and zinc oxide-eugenol(ZOE)) on the temperature of PDJ(pulpo-dentinal junction) has been studied. The geometry used for thermal analysis so far has been limited to two-dimensional as well as axisymmetric tooth models. But the general restorative tooth forms a cross shaped cavity which is no longer two-dimensional and axisymmetric. Therefore, in this study, the three-dimensional model was developed to investigate the effect of shape and size of cavity. This three-dimensional model might be used for further research to investigate the effects of restorative materials and cavity design on the thermal behavior of the real shaped tooth. The results were as follows; 1. When cold temperature of $4^{\circ}C$ was applied to the surface of the restored teeth with amalgam for 2 seconds and recovered to ambient temperature of $20^{\circ}C$, the PDJ temperature decreased rapidly to $29^{\circ}C$ until 3 seconds and reached to $25^{\circ}C$ after 9 seconds. This temperature decreased rather slowly with stainless steel crown, but kept similar temperature within $1^{\circ}C$ differences. Using the gold as a restorative material, the PDJ temperature decreased very fast due to the high thermal conductivity and reached near to $25^{\circ}C$ but the temperature after 9 seconds was similar to that in the teeth without crown. The effects of coldness could be attenuated with the ZOE situated under the cavity. The low thermal conductivity caused a delay in temperature decrease and keeps $4^{\circ}C$ higher than the temperature of other conditions after 9 seconds. 2. The elapse time of cold stimuli was increased also until 4 seconds and recovered to $20^{\circ}C$ after 4 seconds to 9 seconds. The temperature after 9 seconds was about $2-3^{\circ}C$ lower than the temperature of 2 seconds stimuli, but in case of gold restoration, the high thermal conductivity of gold caused the minimum temperature of $21^{\circ}C$ after 5 seconds and got warm to $23^{\circ}C$ after 9 seconds. 3. The effects of hot stimuli was also investigated with the temperature of $60^{\circ}C$. For 2 seconds stimuli, the temperature increased to $40^{\circ}C$ from the initial temperature of $35^{\circ}C$ after 3 seconds of stimuli and decreased to $30^{\circ}C$ after 9 seconds in the teeth without crown. This temperature was sensitive to surface temperature in the teeth with gold restoration. It increased rapidly to $41^{\circ}C$ from the initial temperature of $35^{\circ}C$ after 2 seconds and decreased to $28^{\circ}C$ after 9 seconds, which showed $13^{\circ}C$ temperature variations for 9 seconds upon the surface temperature. This temperature variations were only in the range of $5^{\circ}C$ by using ZOE in the bottom of cavity and showed maximum temperature of $37^{\circ}C$ after 3 seconds of stimuli.

  • PDF

Biodentine-a novel dentinal substitute for single visit apexification

  • Nayak, Gurudutt;Hasan, Mohammad Faiz
    • Restorative Dentistry and Endodontics
    • /
    • v.39 no.2
    • /
    • pp.120-125
    • /
    • 2014
  • Use of an apical plug in management of cases with open apices has gained popularity in recent years. Biodentine, a new calcium silicate-based material has recently been introduced as a dentine substitute, whenever original dentine is damaged. This case report describes single visit apexification in a maxillary central incisor with necrotic pulp and open apex using Biodentine as an apical barrier, and a synthetic collagen material as an internal matrix. Following canal cleaning and shaping, calcium hydroxide was placed as an intracanal medicament for 1 mon. This was followed by placement of small piece of absorbable collagen membrane beyond the root apex to serve as matrix. An apical plug of Biodentine of 5 mm thickness was placed against the matrix using pre-fitted hand pluggers. The remainder of canal was back-filled with thermoplasticized gutta-percha and access cavity was restored with composite resin followed by all-ceramic crown. One year follow-up revealed restored aesthetics and function, absence of clinical signs and symptoms, resolution of periapical rarefaction, and a thin layer of calcific tissue formed apical to the Biodentine barrier. The positive clinical outcome in this case is encouraging for the use of Biodentine as an apical plug in single visit apexification procedures.

Failure of orthograde MTA filling: MTA wash-out? (Orthograde MTA 충전의 실패)

  • Kim, Yu-Ran;Lee, Chan-Young;Kim, Eui-Seoung;Jung, Il-Young
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.6
    • /
    • pp.510-514
    • /
    • 2011
  • Mineral trioxide aggregate (MTA), which was originally developed for repair of root perforations, is a biocompatible material with numerous clinical applications in endodontics. MTA must be allowed to set in the presence of moisture to optimize the material's physical and chemical properties. In the clinic, occasionally unset MTA has been detected after application of MTA on the tooth, and the reason has been unclear. This case report presents MTA washed-out for several years after placement at the root apex as an apical plug, and discusses the reason and things to consider in clinics.

The Clinical Application of an All Ceramic Bridge -A Copy Milling(Celay) Technique (Copy Milling(Celay) System을 이용한 All Ceramic Bridge 임상 증례)

  • Kim, Dae-Hyun
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.9 no.1
    • /
    • pp.82-90
    • /
    • 2000
  • In esthetic dentistry, color and strength are basic requirements for the long-term success of the restorative materials. Several all ceramic systems have been introduced to esthetic dentistry recently. However, the inherent natures of ceramic material, the application of all ceramic system is mainly limited to single tooth restorations. With the improvement of material science, the alumina and zirconia/alumina composite power and block can be applied to fabrication of all ceramic bridges. The conventional inceram core fabrication takes time for sintering however, the shaping of block with a copy milling machine can reduce great amount of time. The block is easy to manipulate and prepare in any shape accurately. This clinical report demonstrates the application of all ceramic ante rior 3 unit bridge with a alumina block in CELAY system.

  • PDF

Tooth-derived bone graft material

  • Kim, Young-Kyun;Lee, Junho;Um, In-Woong;Kim, Kyung-Wook;Murata, Masaru;Akazawa, Toshiyuki;Mitsugi, Masaharu
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.39 no.3
    • /
    • pp.103-111
    • /
    • 2013
  • With successful extraction of growth factors and bone morphogenic proteins (BMPs) from mammalian teeth, many researchers have supported development of a bone substitute using tooth-derived substances. Some studies have also expanded the potential use of teeth as a carrier for growth factors and stem cells. A broad overview of the published findings with regard to tooth-derived regenerative tissue engineering technique is outlined. Considering more than 100 published papers, our team has developed the protocols and techniques for processing of bone graft material using extracted teeth. Based on current studies and studies that will be needed in the future, we can anticipate development of scaffolds, homogenous and xenogenous tooth bone grafts, and dental restorative materials using extracted teeth.