• Title/Summary/Keyword: response reconstruction

Search Result 152, Processing Time 0.021 seconds

Concepts of System Function and Modulation-Demodulation based Reconstruction of a 3D Object Coordinates using Active Method (시스템 함수 및 변복조 개념 적용 능동 방식 3차원 물체 좌표 복원)

  • Lee, Deokwoo;Kim, Jisu;Park, Cheolhyeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.5
    • /
    • pp.530-537
    • /
    • 2019
  • In this paper we propose a novel approach to representation of the 3D reconstruction problem by employing a concept of system function that is defined as the ratio of the output to the input signal. Akin to determination of system function (or system response), this paper determines system function by choosing (or defining) appropriate input and output signals. In other words, the 3D reconstruction using structured circular light patterns is reformulated as determination of system function from input and output signals. This paper introduces two algorithms for the reconstruction. The one defines the input and output signals as projected circular light patterns and the images overlaid with the patterns and captured by camera, respectively. The other one defines input and output signals as 3D coordinates of the object surface and the image captured by camera. The first one leads to the problem as identifying the system function and the second one leads to the problem as estimation of an input signal employing concept of modulation-demodulation theory. This paper substantiate the proposed approach by providing experimental results.

Low-power DWT filter bank design using comb filter and fourth-order polynomial (Comb 필터와 4차 다항식을 사용한 저전력 DWT 필터뱅크 설계)

  • Jang Young-Beom;Lee Won-Sang
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.42 no.1
    • /
    • pp.87-94
    • /
    • 2005
  • In this paper a low-power DWT(Discrete Wavelet Transform) design technique is proposed. As basic low-pass filter for analysis bank, comb filter is utilized, and in order to improve frequency response for the comb filter, a fourth order polynomial is also proposed. Another filters are designed by using perfect reconstruction conditions. The lowpass filter coefficients of the analysis filter bank are optimized based on the cost function and perfect reconstruction condition. The number of the multiplications and MSE(Mean Squared Error) performance of the proposed DWT filter bank are compared with those of the JPEG2000 (9, 7) filter bank. It is shown that number of multiplications of the proposed filter bank are saved with 33.3%, and MSE values of the proposed filter bank are also superior to those of the JPEG2000 (9, 7) filter bank.

A Case Report of Treatment of Heterotrophic Calcification in Pseudohypoparathyroidism (가성 부갑상선 기능저하증의 이형 석회화 치험례)

  • Yoon, Sung-Won;Song, Jea-Yong;Kim, Chung-Hun
    • Archives of Plastic Surgery
    • /
    • v.37 no.3
    • /
    • pp.281-284
    • /
    • 2010
  • Purpose: Pseudohypoparathyroidism is a hereditary disorder characterized by symptoms and signs of hypoparathyroidism, typically in association with distinctive skeletal and developmental defects. Hypoparathyroidism is caused by a insufficient end-organ response to PTH (parathyroid hormone). Hypoparathyroidism consists of four types in which the most common form, pseudohypoparathyroidism-Ia, accompany with Albright's hereditary osteodystrophy. We experienced a case of a woman who had been suffering from calcified mass on left foot, diagnosed Albright's hereditary osteodystrophy. Methods: We present a case of a 24-year-old Korean female who visited plastic surgery department with a painful mass on dorsum of the left foot. On the physical exam, bony hard and painful mass, fixed to dermis, was noted. Plain X-ray films demonstrate suspicious calcification on subcutaneous tissue of dorsum of the left foot. The patient was diagnosed pseudohypoparathyroidism 2 years ago at the plastic surgery department. At the visiting time, the laboratory results were within normal range even though the patient actually had a disease. The reason is because the patient has been treated with Vit.D, calcium replacement therapy and thyroid hormone therapy. Moreover, the patient has been treated with anticonvulsant agents due to epilepsy. On the brain computer tomography (CT), calcification was noted on the basal ganglia and dentate nucleus. So we decided the total excision of entire mass from the left foot. Results: We excised main mass with numerous pinhead sized masses which were scattered around the main mass. The $6.0{\times}4.0{\times}0.5\;cm$ sized main mass was bony hard, and its surface was flat and margin was irregular. The permanent biopsy was confirmed that the main mass and all the scattered tiny masses were heterotopic calcification. The patient did not suffer from the pain after the mass excision. The wound has been healed without any problem. Conclusions: Heterotrophic calcification is often accompanied with pseudohypoparathyroidism, but such a huge one is uncommon. We report a case of pseudohypoparathyroidism with heterotrophic calcification developed in dorsum of left foot who was diagnosed by excisional biopsy.

Region Query Reconstruction Method Using Trie-Structured Quad Tree in USN Middleware (USN 미들웨어에서 트라이 구조 쿼드 트리를 이용한 영역 질의 재구성 기법)

  • Cho, Sook-Kyoung;Jeong, Mi-Young;Jung, Hyun-Meen;Kim, Jong-Hoon
    • Journal of Korea Spatial Information System Society
    • /
    • v.10 no.1
    • /
    • pp.15-28
    • /
    • 2008
  • In ubiquitous sensor networks(USN) environment, it is essential to process region query for user-demand services. Using R-tree is a preferred technique to process region query for in-network query environment. In USN environment, USN middleware must select sensors that transfers region query with accuracy because the lifetime of sensors is that of whole sensor networks. When R-tree is used, however, it blindly passes the region query including non-existent sensors where MBR(Minimum Boundary Rectangle) of R-tree is Intersected by region of query. To solve in this problem, we propose a reconstruction of region query method which is a trie-structured Quad tree in the base station that includes sensors in region of query select with accuracy. We observed that the proposed method delays response time than R-tree, but is useful for reducing communication cost and energy consumption.

  • PDF

An Improved Design Method of FIR Quadrature Mirror-Image Filter Banks (개선된 FIR QMF 뱅크의 설계 방법)

  • 조병모;김영수
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.2C
    • /
    • pp.213-221
    • /
    • 2004
  • A new method for design of two-channel finite-impulse response(FIR) quadrature mirror-image filter(QMF) banks with low reconstruction delay using weighting function is proposed. The weighting function used in this paper is calculated from the previous updated filter coefficients vector which is adjusted from iteration to iteration in the design of QMF banks. In this paper, passband and stopband edge frequency are used in design of QMF banks with low delay characteristic in time domain instead of specific frequency interval where the artifacts occur in conventional design method. The investigation of specific frequency interval where artifacts occur can not be required by using passband and stopband edge frequency. Some comparisons of performance are made with other existing design method to demonstrate the proposed method for QMF bank design. and it was observed that the proposed method using the weighted function and passband and stopband edge frequency improves the peak reconstruction error by 0.001 [dB], the peak-to-peak passband ripple by 0.003[dB], SNR with a white noise by 7[dB] and SNR with a step input by 32[dB], but with a reduction of the computational efficiency because of updating the weighting function over the conventional method in Ref [11].

Aperture Correction using Distance-Dependent Backprojection for SPECT Images (거리 의존적 역투사를 이용한 SPECT 영상 구경보정)

  • Lee, Nam-Yong
    • Journal of Korea Multimedia Society
    • /
    • v.11 no.4
    • /
    • pp.434-442
    • /
    • 2008
  • The parallel beam SPECT acquires projection data by using parallel hole collimators in conjunction with photon detectors. Those projection data of the parallel beam SPECT are, however, contaminated by the distance dependent blurring because of the inaccuracy of the point response function of the collimator that is used to define the range of directions where photons can be detected. Thus an efficient aperture correction is required. In this paper we propose a distance dependent backprojection method to overcome the time limitation of iterative aperture correction methods and the performance limitation of Fourier-Distance Relation based method. The proposed method achieves aperture correction and fast image reconstruction by replacing the distance independent backprojection of the direct image reconstruction with the distance dependent one. We conducted several simulations to compare the performance of the proposed method with that of the conventional Fourier-Distance Relation based method. The simulation result shows that the proposed method outperforms the Fourier-Distance Relation based method in spatial resolution and robustness against noise.

  • PDF

Does acellular dermal matrix expand in response to tissue expander inflation?

  • Yang, Chae Eun;Park, Kwang Hyun;Lee, Dong Won;Lew, Dae Hyun;Song, Seung Yong
    • Archives of Plastic Surgery
    • /
    • v.46 no.1
    • /
    • pp.34-38
    • /
    • 2019
  • Background Acellular dermal matrices (ADMs) have recently become widely used in breast reconstruction, but the correlation between the final expander volume and the surface area of the ADM is not well understood. In this study, the expansion of the surface area of ADM and the expander volume was studied retrospectively in cases of acellular dermis-assisted tissue expander breast reconstruction. Methods Twenty cases of immediate breast reconstruction using an ADM-assisted tissue expander from January 2015 to December 2015 were evaluated. In all 20 cases, CGCryoDerm was used as the matrix, with a thickness of 1-3 mm. No slit incisions were made. Finally, the proportional increase in the area of the fully expanded ADM was compared to that of the tissue expander volume. Results The proportional increase in the ADM surface area was calculated to be from 1.1 to 2.46, with a mean value of 1.7. Additionally, under the assumption that the expander had a spherical shape, the increase in its radius (the cube root of its volume) was assessed. The range of the proportional increase in the expander radius was 1.1 to 2.24, with a mean value of 1.66. The proportional increase in the radius of the expanded ADM surface area ranged from 1.04 to 1.34, with a mean ratio of 1.28. Conclusions The results of this study confirmed that the ADM expanded when the tissue expander was inflated. However, the ADM expanded to a lesser extent than the tissue expander, indicating that the muscle and other tissues expanded more than the ADM when the tissue expander was inflated.

A Study on Retrospective of External Radiation Exposure Dose by Optically Stimulated Luminescence of Smart Chip Card (스마트칩 카드을 이용한 광 자극 발광 특성 연구)

  • Park, Sang-Won;Yoo, Se-Jong
    • Journal of radiological science and technology
    • /
    • v.42 no.5
    • /
    • pp.379-385
    • /
    • 2019
  • Radiation is used for various purposes such as cancer therapy, research of industrial and drugs. However, in case of radiation accidents such as terrorism, collapsing nuclear plant by natural disasters like Fukushima in 2011, very high radiation does expose to human and could lead to death. For this reason, many people are concerning about radiation exposures. Therefore, assessment and research of retrospective radiation dose to human by various path is an necessary task to be continuously developed. Radiation exposure for workers in radiation fields can be generally measured using a personal exposure dosimeter such as TLD, OSLD. However, general people can't be measured radiation doses when they are exposed to radiation. And even if radiation fields workers, when they do not in possession personal dosimeter, they also can't be measured exposure dose immediately. In this study, we conduct retrospective research on reconstruction of dose after exposure by using smart chip card of personal items through Optically Stimulated Luminescence (OSL). The OSL signal of smart chip card shows linear response from 0.06 Gy to 15 Gy and results of fading rate 45 %, 48% for 24 and 48 hours due to the natural emission of radiation in sample, respectively. The minimum detectable limit (MDD) was 0.38 mGy. This values are expected to use as correction values for reconstruction of exposure dose.

Comparison of Digital Filters with Wavelet Multiresolution Filter for Electrogastrogram (위전도 신호처리를 위한 웨이브렌 필터와 디지털 필터의 비교)

  • 유창용;남기창;김수찬;김덕원
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.2
    • /
    • pp.109-117
    • /
    • 2002
  • Electrogastrography(EGG) is a noninvasive method for measuring gastric electrical activity on the abdomen resulting from gastric muscle. EGG signals have a very low frequency range (0.0083 ~0.15 Hz) and extremely low amplitude(10~100 uV). Consequently, EGG signal is easily influenced by other noises. Both finite impulse response(FIR) and infinite impulse response (IIR) filters need high orders or have phase distortions for passing very narrow bandwidth of the EGG signal. In this study, we decomposed EGG signals using a wavelet multiresolution method with Daubechies mother wavelet. The EGG signals were decomposed to seven levels. We reconstructed signal by summing the decomposed signals from level four to seven. To evaluate the performance of the wavelet multiresolution filter(WMF) with simulated EGG signal using two kinds of FIR and four kinds of IIR filters., we used two indices; signal to noise ratio(SNR) and reconstruction squared error(RSE). The SNR of WMF had 9.5, 6.9, and 4.7 dB bigger than that of the other filters at different noise levels, respectively. Also, The RSE of WMF had $1.22{\times}10^6, 1.16{\times}10^6, 1.02{\times}10^6$ smaller than that of the other filters at different noise levels, respectively. The WMF performed better in the SNR and RSE than two kinds of FIR and four kinds of IIR filters.

An Efficient Design Method of Linear-Phase Prototype Lowpass Filter for Near-Perfect Reconstruction Pseudo-QMF Banks (근접 완전재생 Pseudo-QMF 뱅크를 위한 선형위상 프로토타입 저역통과 필터의 효율적인 설계 방법)

  • Jeon, Joon-Hyeon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.3C
    • /
    • pp.271-280
    • /
    • 2008
  • M channel near-perfect-reconstruction(NPR) pseudo-QMF banks are a hybrid of conventional pseudo-QMF design and spectral factorization approach where the analysis and synthesis filters are cosine-modulated versions of the prototype-lowpass filter(p-LPF). However, p-LPF H(z) does not have linear-phase symmetry as well as magnitude-distortion optimization since it is obtained by spectral factorization of $2M^{-th}$ band filter $G(z)=z^{-(N-1)}H(z^{-1})H(z)$. A fair amount of attention, therefore, has been focused on the design of filter banks for reducing only alias-cancellation distortion without reconstructed-amplitude distortion. In this paper, we propose a new method for designing linear-phase p-LPF in NPR pseudo-QMF banks, which is based on Maxflat(maximally flat) FIR filters with closed-form transfer function. In addition, p-LPF H(z) is optimized in this approach so that the 2M-channel overall distortion response represented with $G(z)=H^2(z)$ approximately becomes an unit magnitude response. Through several examples of NPR pseudo-QMF banks, it is shown that the peek ripple of the overall magnitude distortion is less than $3.5{\times}10^{-4}\;({\simeq}-70dB)$ and analysis/synthesis filters have the sharp monotone-stopband attenuation exceeding 100 dB.