• Title/Summary/Keyword: resonance test

Search Result 991, Processing Time 0.025 seconds

Estimation of Mechanical Properties of Concrete in Early Age by Resonance Frequency Test (공명주기식 동탄성계수를 이용한 초기재령 콘크리트의 역학적 성질 예측)

  • Kim, Jin-Keun;Kiim, Hoon;Noh, Jae-Ho
    • Magazine of the Korea Concrete Institute
    • /
    • v.7 no.5
    • /
    • pp.164-171
    • /
    • 1995
  • Drying shrinkage and hydration heat are important factors on the initiation of the crack in con crete at early age. Therefore, the stress caused by hydration heat and drying shrinkage should be .analyzed to predict whether the crack occurrs or not. And, mechanical properties of early age concrete is also required for the predicting crack formation In this study, non-destructive test method of resonance frequency was used to find the relation between dynamic modulus and mechanical properties of concrete in early age. Test results were compared with existing equations, and a new equation based on test. results in this study and other data was also proposed

An Evaluation of Elastic Aspects of PVC/MBS by An Acoustic Resonance Method (음향공진법을 이용한 PVC/MBS의 탄성적 특성 평가)

  • Lee, D.H.;Bahk, S.M.;Park, M.K.
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.603-608
    • /
    • 2001
  • A certain amount of MBS rubber was added to improve toughness of PVC which has a strong tendency of being brittle, producing a mixture, PVC/MBS, from which test specimens were prepared. PVC has strong chemical resistance, oil resistance, frame retardancy and high mechanical strength. Also, it is relatively inexpensive to produce, but shows weakness to impact and difficult for processing. MBS, a typical toughening agent for PVC is generally known, when added in a small amount, to improve impact resistance and to minimize difficulties during the processing of the PVC without adversely affecting the positive aspects of the PVC. In this investigation, attempts were made to observe and determine the variations in elastic and damping constants of the PVC depending on the amounts of MBS added to the mixture, PVC/MBS, and also on the thicknesses of the specimens. An acoustic resonance technique was used for the tests in this investigation. It serves as a method to characterize properties of materials set in vibrational motions, which is initiated by low level stresses generated by externally supplied acoustic energy. Substantial variations were observed in the test results with the addition of the MBS to the PVC. Generally, the magnitudes of elastic constants decrease while the damping capacity improves when MBS rubber was added.

  • PDF

A Study on the Improvement of Radiated Noise in SCR Muffler of Commercial Vehicle (상용차용 SCR 머플러의 방사소음 개선에 관한 연구)

  • Lee, Dong-Won;Kim, Wan-Su;Bae, Chul-Yong;Kim, Chan-Jung;Kwon, Sung-Jin;Lee, Bong-Hyun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.8
    • /
    • pp.816-822
    • /
    • 2008
  • This study presents the design modification for SCR muffler of a commercial vehicle. Its main objective is the reduction of radiated noise at SCR muffler. For this study, the research of five steps were achieved by experimental and CAE analysis. First step is the measurement of radiated noise using impact-acoustic test. Second step is the source identification using experimental modal analysis. The cause of radiated noise source is confirmed by the resonance of end plates at SCR muffler. Third step confirms the possibility of resonance avoidance using SDM analysis applied the mass control. Fourth step is the suggestion of design modification which is the change of mode shape by CAE analysis. Last step is the verification of design modification using SYSNOISE analysis. Finally, the prototype product applied the countermeasure of resonance evasion was manufactured and the reduction of radiated noise at SCR muffler was confirmed by pass-by noise test.

A Study on Resonance and Interference of a Cooling Fan Assembly by Using FEM (유한요소법을 이용한 쿨링팬의 진동 및 간섭에 관한 연구)

  • 정일호;송하종;박태원;김주용
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.919-924
    • /
    • 2004
  • A CFA(Cooling Fan Assembly) is composed of a fan, motor and shroud, which is at the back of the automotive radiator. By forcing the wind to pass, the CFA controls the cooling performance of the radiator. The noise and vibration of the CFA may be primarily due to the resonance between the CFA and engine. The Interference among the fan, shroud and radiator by deformation is considered when the CFA is designed. In this paper, in order to analyze the structural vibration of the CFA for automobiles, a finite element model of the CFA is established by using a commercial FEM code. After the finite element modeling, the natural frequencies and the mode shapes are obtained from the FE analysis. The natural frequencies are obtained from the vibration test as well. Then, the results of the vibration test are compared with those of the FE analysis. The natural frequencies obtained by experiment have a great similarity to the results from FE model. We have confirmed the validity of the FE model and verify the structural safety for the resonance. The stress and displacements are obtained from FE analysis. We have confirmed the safety for the interference and failure.

  • PDF

Study on Analysis of Vibration Characteristics and Modal Test for a Quad-Rotor Drone (쿼드로터형 드론의 진동특성 분석 및 실험에 관한 연구)

  • Kim, Minsong;Kim, Jaenam;Byun, Youngseop;Kim, Jeong;Kang, Beomsoo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.9
    • /
    • pp.707-714
    • /
    • 2016
  • This paper describes analysis results of vibration characteristics and modal test for a small-scale quad-rotor drone. The rotor arm has a slender body with a propeller and motor at its tip. Rotor system generates excitation for an unbalanced mass. Therefore, the drone platform is involved in the possibility of resonance. For advance identification of the possibility of resonance, confirmation of eigen-mode being closest to the propeller operation range is necessary. Material properties of CFRP tubes used for the rotor arm were acquired by finding the natural frequency based on Rayleigh method. A simplified quad-rotor FE model consisting of rotor arm assembly with tip mass was built to perform numerical analysis, and a free-free boundary condition was applied to provide flight status. Modal tests for the actual platform with impact hammer instrument were performed to verify analysis results. Separation margin from hazardous eigen-mode was checked on the propeller operation range.

Emerging Role of Hepatobiliary Magnetic Resonance Contrast Media and Contrast-Enhanced Ultrasound for Noninvasive Diagnosis of Hepatocellular Carcinoma: Emphasis on Recent Updates in Major Guidelines

  • Tae-Hyung Kim;Jeong Hee Yoon;Jeong Min Lee
    • Korean Journal of Radiology
    • /
    • v.20 no.6
    • /
    • pp.863-879
    • /
    • 2019
  • Hepatocellular carcinoma (HCC) can be noninvasively diagnosed on the basis of its characteristic imaging findings of arterial phase enhancement and portal/delayed "washout" on computed tomography (CT) and magnetic resonance imaging (MRI) in cirrhotic patients. However, different specific diagnostic criteria have been proposed by several countries and major academic societies. In 2018, major guideline updates were proposed by the Association for the Study of Liver Diseases, European Association for the Study of the Liver (EASL), Korean Liver Cancer Association and National Cancer Center (KLCA-NCC) of Korea. In addition to dynamic CT and MRI using extracellular contrast media, these new guidelines now include magnetic resonance imaging (MRI) using hepatobiliary contrast media as the first-line diagnostic test, while the KLCA-NCC and EASL guidelines also include contrast-enhanced ultrasound (CEUS) as the second-line diagnostic test. Therefore, hepatobiliary MR contrast media and CEUS will be increasingly used for the noninvasive diagnosis and staging of HCC. In this review, we discuss the emerging role of hepatobiliary phase MRI and CEUS for the diagnosis of HCC and also review the changes in the HCC diagnostic criteria in major guidelines, including the KLCA-NCC practice guidelines version 2018. In addition, we aimed to pay particular attention to some remaining issues in the noninvasive diagnosis of HCC.

EVALUATION OF BONE RESPONSE BY RESONANCE FREQUENCY ANALYSIS OF ANODIZED IMPLANTS

  • Roh Hyun-Ki;Heo Seong-Joo;Rhyu In-Chul
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.6
    • /
    • pp.745-750
    • /
    • 2005
  • Statement of problem. Resonance frequency analysis has been increasingly served as a non-invasive and objective method for clinical monitoring of implant stability. Many clinical studies must be required for standardized data using RFA. Purpose. This study was performed to evaluate RFA value changes in two anodized implant groups. Material and method. Among a total of 24 implants, twelve screw shaped implants as a test group (H2-R8.5) were manufactured, which had a pitch-height of 0.4 mm, an outer diameter of 4.3 mm, a length of 8.5 mm, and external hexa-headed, were turned from 5 mm rods of commercially pure titanium (ASTM Grade IV, Warantec Co., Seoul, Korea), and another twelve implants as a control group were $Br{\aa}nemark$ Ti-Unite MK4 (diameter 4.0 mm, length 8.5 mm). Each group was installed in tibia of rabbit. Two implants were placed in each tibia (four implants per rabbit). Test two implants were inserted in right side and control two in left side. ISQ values were measured using $Osstell^{TM}$ (Integration Diagnostics Ltd. Sweden) during fixture installation, and 12 weeks later and evaluated the RFA changes. Results. Mean and SD of baseline ISQ values of test group were $75.0{\pm}3.4$ and $68.7{\pm}8.1$ for control group. Mean and SO of ISQ values 12 weeks after implant insertion were $73.2{\pm}4.7$ for test group and $72.6{\pm}3.9$ for control group. There were no statistically significant differences between groups in ISQ values after 3 months (P>0.05). From the data, RFA gains after 3 months were calculated, and there was statistically significant difference between groups (P<0.05). Conclusion. Although there were RFA changes between groups, implant stability after experimental period shows alike tendency and good bone responses.

Thickness Measurements of the Base Concrete by the Impact-resonance Test (탄성파 공진법에 의한 기초 콘크리트의 두께 측정)

  • 김영환
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1989.10a
    • /
    • pp.53-58
    • /
    • 1989
  • Thicknesses of the base concrete blocks for large machines were estimated by analyzing the resonance modes of mechanical vibrations. The vibration was produced by the mechanical impact and detected by a wideband conical transcuder. There signals were analyzed by FET and thicknesses were obtained by the peaks of frequency spectrum. The estimated thickness upto 100cm are in good agreement with the real ones. For the layered concrete block, the estimated thickness is dependent on the acoustic reflective index at the boundary of the two layers.

  • PDF

Antenna Factors of Half-wave Resonance Dipole Antennas above the Ground Plane (접지판 위에 놓여진 반파장 공진다이폴 안테나의 안테나 인자)

  • Ki-Chai Kim
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.2 no.4
    • /
    • pp.3-9
    • /
    • 1991
  • This paper presents the characteristics of antenna factors of half-wave resonance dipole antennas above a ground plane. The current distributions on a horizontal and vertical dipole antennas were analyzed by the Galerkin's method of moments, and these solutions are used for calculating the horizontal and vertical antenna factors above the ground plane. It is shown that accurate antenna factors of the horizontal and vertical dipole above the ground plane are required of the radiated emission test.

  • PDF