• Title/Summary/Keyword: resonance test

Search Result 991, Processing Time 0.026 seconds

Ground Vibration Test for Korean Utility Helicopter (한국형 기동헬기 전기체 지상진동시험)

  • Kim, Se-Hee;Kwak, Dong-Il;Jung, Se-Un;Choi, Jong-Ho;Kim, Joung-Hun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.6
    • /
    • pp.495-501
    • /
    • 2013
  • Korean Utility Helicopter (KUH) has been designed to avoid the blade passing frequency and any instability due to a coupling of dynamic characteristics between the main rotor and the airframe in ground operation. For these design objectives, the vibration analysis and the ground resonance analysis were performed to analyze the dynamic characteristics of the airframe and the main rotor. Then, the whirl-tower test was conducted to identify the dynamic characteristics of the main rotor and the ground vibration test (GVT) was conducted to identify the dynamic characteristics of the airframe. The GVT for KUH was conducted with the test conditions and test articles established in consideration of each flight and ground condition. This paper shows the method and technique for performing the GVT for KUH and presents the correlation technique and the results for the correlated analysis model.

Improvement and Operation of a Helicopter Tail-Fan Performance Test System (헬리콥터 테일팬 시험장치 개조 및 운용)

  • Lee, Je-Dong;Song, Keun-Woong;Kang, Hee-Jung;Sim, Jung-Wook;Kim, Seung-Bum
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11b
    • /
    • pp.41-44
    • /
    • 2005
  • This paper described improvement and operation of a 'Tail-Fan' anti-torque performance test system KARI (Korea Aerospace Research Institute) developed a 'Tail-Fan' anti-torque system of a helicopter and a performance test-rig to test the performance of the Tail-Fan. The test-rig was improved for full rotating test in 4300rpm(100%). Machinery and hydraulic parts ware changed to reduce vibration and to increase safety. To find the operation rotating speed for the performance test, vibration test were carried out rising accelerometers on tail gear box. The performance test conditions of the Tail-Fan to avoid a resonance were found from vibration test results. The Tail-Fan operation tests were performed safely frier to carry out performance test.

  • PDF

The Operation and Vibration Characteristics of Tail-Fan Performance Test System (테일팬 성능시험장치의 운용과 진동특성)

  • Song, Ken-Woong;Kim, Jun-Ho;Kang, Hee-Jung;Rhee, Wook;Sim, Jung-Wook
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.508-512
    • /
    • 2004
  • This paper described operation and vibration characteristics of 'Tail-Fan' performance test system. KARI(Korea Aerospace Research Institute) developed 'Tail-Fan' system as a kind of helicopter anti-torque system(ATS) and designed ATS performance test-rig for Tail-Fan system performance test. Test-rig consists of driving parts, supporting parts and rotating parts. For Tail-Fan system performance tests, firstly, test-rig operation tests were carried out for verification of design specifications. Secondly, natural frequencies of fan blade and test-rig were measured respectively. Lastly, to find the operation rotating speed for performance tests, vibration tests using accelerometers on tail gear box(TGB) were carried out. Through the fanplot and vibration test results, Tail-Fan performance test conditions to avoid a resonance were found and performance tests were well done safely.

  • PDF

Investigation of the BSR Noise characteristics in Seat Cushion-frame with respect to Vibration Durability Test Using Multi-simulator (다축 가진기를 이용한 시트 쿠션 프레임의 내구 전후 BSR 진동특성 연구)

  • Choi, Ho-Il;Nam, Jae-Hyun;Kang, Jae-Young;Park, Jung-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.8
    • /
    • pp.4776-4783
    • /
    • 2014
  • Many studies have examined the reduction of primary noise sources, but quality-related noise, such as BSR, is rarely studied. This study describes the quantitative BSR test method using a multi-axial simulator. The sine sweep test was conducted to detect the system resonance and its relation to BSR noise with high frequency. This method is applied to the seat frame with/without the vibration durability test. The results showed that the $1^{st}$ lateral resonance leads to higher BSR frequency noise. In addition, the reduction of the lateral mode system stiffness after the durability test results in a decrease in the BSR noise in sine sweep test mode.

Analysis of Ultrasonic Resonance Signal in Multi-Layered Structure (다중접착구조물의 초음파 공진 신호 분석)

  • Kim, Dong-Ryun;Kim, Jae-Hoon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.4
    • /
    • pp.401-409
    • /
    • 2012
  • Ultrasonic testing are far superior to other nondestructive tests for detecting the disbond interface which occurred in adhesive interface. However, a solid rocket motor consisting of a steel case, rubber insulation, liner, and propellant poses many difficulties for analyzing ultrasonic waves because of the superposition of reflected waves and large differences in acoustic impedance of various materials. Therefore, ultrasonic tests for detecting the disbond interface in solid rocket motor have been applied in very limited areas between the steel case and rubber insulation using an automatic C-scan system. The existing ultrasonic test cannot detect the disbond interface between the liner and propellant of a solid rocket motor because most of the ultrasonic waves are absorbed in the rubber material which has low acoustic impedance. This problem could be overcome by analyzing the resonance frequency from the frequency spectrum using the ultrasonic resonance method. In this paper, a new technique to detect the disbond interface between the liner and propellant using ultrasonic resonance characteristics is discussed in detail.

Detection of Micro-Crack Using a Nonlinear Ultrasonic Resonance Parameters (비선형 초음파공명 특성을 이용한 미세균열 탐지)

  • Cheong, Yong-Moo;Lee, Deok-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.4
    • /
    • pp.369-375
    • /
    • 2012
  • In order to overcome the detection limit by the current nondestructive evaluation technology, a nonlinear resonant ultrasound spectroscopy(NRUS) technique was applied for detection of micro-scale cracks in a material. A down-shift of the resonance frequency and a variation of normalized amplitude of the resonance pattern were suggested as the nonlinear parameter for detection of micro-scale cracks in a materials. A natural-like crack were produced in a standard compact tension(CT) specimen by a low cycle fatigue test and the resonance patterns were acquired in each fatigue step. As the exciting voltage increases, a down-shift of resonance frequency were increases as well as the normalized amplitude decrease. This nonlinear effects were significant and even greater in the cracked specimen, but not observed in a intact specimen.

Bone Response to Anodized Titanium Implants in Rabbits

  • Lee, Jae-Hyun;Lee, Cheol-Won;Kim, Chang-Hyen;Pyo, Sung-Woon
    • Journal of Korean Dental Science
    • /
    • v.4 no.1
    • /
    • pp.26-32
    • /
    • 2011
  • Purpose: The quality of implant surface is one of the factors that influence wound healing of implant site and subsequently affect osseointegration. The objective of modification of the surface properties of an implant is to affect the biological consequence. The purpose of this study is to evaluate the biologic response of osseous tissue to anodized implants. Materials and Methods: Two machined titanium implants for control group were installed in a tibia of each rabbit and two anodized implants for test group were installed in the other tibia of each rabbit. At the moment the implants were installed, resonance frequency analysis (RFA) values were measured. After healing periods of 1, 2, 3, and 7 weeks, the implants were uncovered and RFA values were measured again. Removal torque was measured for one implant in the test group and one implant in the control group. Histological evaluation was executed in the other implants. Results: Both of test group and control group have the tendency of greater RFA change rate and removal torque value as healing periods became longer, but were statistically insignificant (P>0.05). However, in the case of the same healing period, the test group tended to have greater RFA change rate and removal torque than the control group (P<0.05). More active new bone formation from endosteal surface was noted on the anodized surface than machined surface in specimen after 1 week. There were no significant differences between the test group and control group in histological evaluations. Conclusion: In summary, the anodized surface showed slightly favorable results and it is postulated that it may facilitate improved stability in bone.

Attention Degradation of Occupant Driving Vehicle on Cross-country Test Road According to Vibration Exposure Time (야지 시험로 주행 진동 노출 시간에 따른 탑승자의 주의력 저하에 관한 연구)

  • Park, Dong-Jun;Choi, Moon-Gee;Song, Jong-Tak;Ahn, Se-Jin;Jeong, Weui-Bong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.27 no.2
    • /
    • pp.155-161
    • /
    • 2017
  • When a military vehicle is driven on a cross-country road, the occupants are exposed to vibration at a body resonance. In case that the exposure continues for too long period, the attention ability of the occupant could be affected by the vibration exposure. In the study, it was experimentally tried to find if there is a correlation between degradation of attention and vibration exposure. Two kinds of test among various psychological attention tests were employed, which were selected with considering a situation of carrying out military mission on vehicle. At the result, the searching test for controlled attention showed significant degradation in the accuracy and performance time in case of exposure at the vibration. And the attention degradation appeared to be greater when the vibration exposure increases. The dual task test for divided attention showed the difference between vibration and non-vibration condition, but showed it is insignificant for the attention to degrade by increasing exposure time.

Development of Optimum Cushioning Packaging System of Strawberry for Domestic Parcel Delivery Service (국내 택배용 딸기의 적정 완충포장 시스템 개발)

  • Jung, Hyun Mo;Kim, Su Il;Park, Jong Min
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.26 no.2
    • /
    • pp.113-118
    • /
    • 2020
  • Due to the rapid increase in cyber shopping mall of agricultural products, the parcel delivery service industry also increased, making it necessary to design an optimum packaging for agricultural products. And Due to the recent increase in strawberry consumption, there is also a need for a packaging system for parcel delivery service. In order to establish the criteria for optimum cushioning packaging design of strawberries, the bioyield strength of strawberries by storage time was measured through the ASABE test standards, and the peak acceleration in the resonance frequency and resonance frequency bands of strawberries was measured through the vibration test regulated in the ASTM test specifications. Tray cup pad and corrugated fiberboard box of delivery strawberries were designed using FEM theoretical analysis of contact stress and resonant frequency. In addition, an optimum packaging system was developed with a cushioning and vibration design considering the impact characteristics when distributing agricultural products. Through the performance evaluation and on-site evaluation of the optimum packaging system of strawberries for parcel delivery service, the random PSD test results of the delivery showed a 74% reduction in the acceleration level, and the actual distribution test of the delivery showed that the damage rate of strawberries was not more than 6.7%, indicating that it was possible to use the optimum packaging of strawberries for delivery.

Finite element analysis of stabilization splint pressure distribution in a patient with disc displacement without reduction: A preliminary study

  • Acing Habibie Mude;Muhammad Ikbal;Mukhsan Putra Hatta;Irfan Sugianto;Edy Machmud;Fadhlil Ulum A Rahman;Imran Irsal;Eka Fibrianti;Muthia Mutmainnah Bachtiar;Thalib Rifky Samdany Abdullah Syeban Attamimi
    • Imaging Science in Dentistry
    • /
    • v.54 no.3
    • /
    • pp.251-256
    • /
    • 2024
  • Purpose: This study was performed to investigate the pattern of condylar pressure distribution in the discs of a patient diagnosed with disc displacement without reduction. Materials and Methods: This research consisted of a pre- and post-test observational clinical study. A patient diagnosed with disc displacement without reduction underwent treatment with an occlusal splint for 3 months. Finite element analysis employed a 3-dimensional model constructed from magnetic resonance images of the patient, taken both before the application of the splint and 3 months after its use. Results: The post-test model demonstrated a decrease in condylar pressure on the disc, with measurements dropping to 72 MPa from the pre-test level of 143 MPa. In the pre-test, the pressure distribution pattern was concentrated on the lateral posterior border, whereas in the post-test, it shifted toward the intermediate zone of the disc. Conclusion: Utilization of a stabilization splint for 3 months resulted in decreased pressure and a marked change in the pressure distribution pattern on the temporomandibular disc.