• Title/Summary/Keyword: resistance test

Search Result 6,837, Processing Time 0.032 seconds

Effect of PVA Fiber and Silica Fume Addition on Chloride Penetration Resistance of Alkali-Activated Slag (PVA 섬유와 실리카흄 첨가가 알칼리 활성 슬래그의 염화물 침투 저항성에 미치는 영향)

  • Yoon, Hyun No
    • Journal of Urban Science
    • /
    • v.12 no.2
    • /
    • pp.13-18
    • /
    • 2023
  • This study investigates the effect of polyvinyl alcohol (PVA) fiber and silica fume addition on the chloride penetration resistance of alkali-activated slag. Silica fume was added to replace slag at the dosage of 0, 5, 10, and 20% by weight of the binder, while PVA fiber was added at the dosage of 0, 1, and 2% by volume of the mixture. Samples were synthesized via alkali activator with 1.0 of silicate modulus and cured at room temperature for 28 days. Compressive strength test, permeable voids volume test, water absorprtion test, and rapid chloride penetration test were conducted for measuring the charaterisitics of alkali-activaed slag. The results showed that increasing silica fume content up to 10% in alkali-activated slag improved compressive strength and chloride penetration resistance. Addition of PVA fibers up to 1% by volume enhanced strength and chloride penetration resistance, but exceeding this led to reduced strength and durability due to increased void formation in the matrix.

Electrical Resistance Measurement in Characterizing the Internal Damage of Carbon Nanotube/Polypropylene Nanocomposites (전기저항 측정법을 이용한 탄소나노튜브/폴리프로필렌 나노복합재료의 내부 손상 예측)

  • Kim, Hak-Soo;Kwon, Dong-Jun;Wang, Zuo-Jia;Gu, Ga-Young;Kim, Dae-Sik;Lee, Chun-Soo;Park, Joung-Man
    • Composites Research
    • /
    • v.26 no.3
    • /
    • pp.201-206
    • /
    • 2013
  • The electrical resistance measurement was investigated as a damage monitoring method. In this study, 0.5 wt% Carbon nanotube reinforced polypropylene (CNT/PP) composites were evaluated under compressive fatigue loading. The shape of specimens was $20^{\circ}$ curved round type. Compression strength and electrical resistance were measured at different sections of specimen during compression. The microcracks of CNT/PP composites were detected based on the changing ratio of electrical resistance. Micro-damage during compressive fatigue test could be detected by electrical resistance measurements. The reason is that the contact points of CNTs in composites decreased under fatigue loading. During compressive fatigue test, larger change of electrical resistance was detected at the microcrack sections. It was proved that microcracks could be detected by electrical resistance measurement under compression test, whereas the real delamination parts were consistent with the predicted results by electrical resistance measurement.

The combustion test of assuming in parking space for fire resistance (지하주차장의 내화성능 평가를 위한 차량연소실험)

  • Kang, Seung Goo;Kim, Dong Jun;Lee, Jae Young;Harada, Kazunori;Kwon, Young Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.48-50
    • /
    • 2013
  • In this study, Car fire for test using ISO 9705 10MW Large Scale Calorimeter. Especially, study on the underground parking for the fire resistance performance. The underground parking lot of the fire resistance regulations in according to with the standard heating curve in Korea. Because of this burning car through experiments to the propose a new heating curve.

  • PDF

A Study on the Physical Properties of Recycled Asphalt Mixtures Using Glass Fiber Reinforcement (유리섬유 보강재를 이용한 재활용 아스팔트 혼합물의 물리적 특성에 관한 연구)

  • Park, Ki Soo;Yoo, Pyeong Jun
    • International Journal of Highway Engineering
    • /
    • v.20 no.4
    • /
    • pp.27-34
    • /
    • 2018
  • PURPOSES : The objective of this study is to evaluate the physical properties of recycled asphalt mixtures reinforced with glass fiber. METHODS : Firstly, mixing design was conducted on recycled asphalt mixture for use of 50% recycled aggregate. Various laboratory tests were performed on four types of recycled asphalt mixtures with different glass fiber content to evaluate the physical properties. The laboratory tests include indirect tensile strength test, dynamic modulus test, Hamburg wheel tracking test and tensile-strength ratio to evaluate cracks, rutting and moisture resistance of mixtures. RESULTS : The indirect tensile strength of fiber reinforced glass increased about 139.4%. As a result of comparing the master curves obtained by the dynamic modulus test, the elasticity was low in the low temperature region and high in the high temperature region when the glass fiber was reinforced. The glass fiber contents of PEGS 0.3%, Micro PPGF 0.1% and Macro PPGF 0.3% showed the highest moisture resistance and rutting resistance. CONCLUSIONS : The test results show that use of glass fiber reinforcement can increase the resistance to cracking, rutting, and moisture damage of asphalt mixtures. It is also necessary to validate the long-term performance of recycled asphalt mixtures with glass fiber using full scale pavement testing and field trial construction.

Highly Accelerated Life Tests for Auto-Connector in Use-Environment (자동차 환경을 고려한 커넥터의 가속시험에 관한 연구)

  • Kim Jong-Gurl;Kim Jin-Hawn
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2004.11a
    • /
    • pp.229-235
    • /
    • 2004
  • This paper treats accelerated life tests for automotive connector. The contact resistance of connector is explained by some factors; the use time(calender time, real cycle), stresses and loads adapted in auto test. The relationships between contact resistance and some factors are compared and analyzed by regression models in various test conditions; field use-environment, manufacturer's test environment, and accelerated test condition. The consistency between of manufacturer's test and field test is examined. Finally, the future study on accelerated test for automotive connector is presented.

  • PDF

Chemical Resistance Characteristics of Concrete Surface Coating Agent with Flexibility (유연성을 갖는 콘크리트 표면보호재의 내화학적 특성)

  • Han, Sang-Hoon;Yoon, Ju-Yong;Lee, Byung-Ro;Hong, Ki-Nam
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.3
    • /
    • pp.96-103
    • /
    • 2012
  • The purpose of this study is evaluate the ability of coating materials developed in order to prevent the durability deterioration of the concrete structure. Neutralization test, freezing and thawing test, and sulfate resistance test were performed in this study. Test results show that the developed coating material is effective against durability deterioration.

Study on the procedure to obtain an attainable speed in pack ice

  • Kim, Hyun Soo;Jeong, Seong-Yeob;Woo, Sun-Hong;Han, Donghwa
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.10 no.4
    • /
    • pp.491-498
    • /
    • 2018
  • The cost evaluation for voyage route planning in an ice-covered sea is one of the major topics among ship owners. Information of the ice properties, such as ice type, concentration of ice, ice thickness, strength of ice, and speed-power relation under ice conditions are important for determining the optimal route in ice and low operational cost perspective. To determine achievable speed at any designated pack ice condition, a model test of resistance, self-propulsion, and overload test in ice and ice-free water were carried out in a KRISO ice tank and towing tank. The available net thrust for ice and an estimation of the ice resistance under any pack ice condition were also performed by I-RES. The in-house code called 'I-RES', which is an ice resistance estimation tool that applies an empirical formula, was modified for the pack ice module in this study. Careful observations of underwater videos of the ice model test made it possible to understand the physical phenomena of underneath of the hull bottom surface and determine the coverage of buoyancy. The clearing resistance of ice can be calculated by subtracting the buoyance and open water resistance form the pre-sawn ice resistance. The model test results in pack ice were compared with the calculation results to obtain a correlation factor among the pack ice resistance, ice concentration, and ship speed. The resulting correlation factors were applied to the calculation results to determine the pack ice resistance under any pack ice condition. The pack ice resistance under the arbitrary pack ice condition could be estimated because software I-RES could control all the ice properties. The available net thrust in ice, which is the over thrust that overcomes the pack ice resistance, will change the speed of a ship according to the bollard pull test results and thruster characteristics (engine & propulsion combination). The attainable speed at a certain ice concentration of pack ice was determined using the interpolation method. This paper reports a procedure to determine the attainable speed in pack ice and the sample calculation using the Araon vessel was performed to confirm the entire process. A more detailed description of the determination of the attainable speed is described. The attainable speed in 1.0 m, 90% pack ice and 540 kPa strength was 13.3 knots.

Evalulation of Specific Gravity in Post Member by Drilling Resistance Test

  • Park, Chun-Young;Kim, Se-Jong;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.34 no.2
    • /
    • pp.1-9
    • /
    • 2006
  • The structural wooden members of the ancient building are deteriorated by fungi and termite over time. The deteriorate of the members causes the decrease of the specific gravity and the strength of it, so the stability of the building is threatened. Therefore, in this study, the evaluation of the specific gravity, which is correlated with the strength of the wood, was conducted in the post member using Nondestructive Evaluation (NDE) - Drilling Resistance Test (DRT). For the purpose of it, the specific gravity and drilling resistance of small specimens was measured to obtain the correlation between the specific gravity and the drilling resistance. And then, the drilling resistance test of the post members, which were expected to have the deteriorated parts, was performed. Consequently, the correlation between the specific gravity and the drilling resistance was very high ($R^2=0.89$) and the distributions of the specific gravity were evaluated for the each member. Also, the results were verified by the visual inspection of the cross section of it. Especially, the various variations of the wood member such as the deteriorated parts with termite or fungi and the crack could be detected exactly but the knot couldn't because the drill could pass by or could not penetrate the knot.

A Study on the Development of a Dry PFB Method with High Fire Resistance (고강도콘크리트 내화성능을 확보한 건식화 PFB 공법 개발에 관한 연구)

  • Kim, Woo-Jae;Jung, Sang-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2008.11a
    • /
    • pp.49-52
    • /
    • 2008
  • The present study was to develop a dry PFB method similar to the existing gypsum board construction method in order to apply the existing wet PFB method that uses fire-resistant adhesive. It was found that the existing wet method can produce concrete compressive strength of 80MPa and fire resistance of 3 hours with 30mm PF boards. The goal of development in this study was fire resistance of 3 hours through dry construction of 15mm fire-resistant boards. 1. Improved PF board was prepared by adding inorganic fiber to existing board and using aggregate with grain size of 3mm or less. Molding was done at temperature higher than that for existing PF board molding. While wet curing is used for existing PF boards, this study used dry curing in order to enhance heat insulation performance. 2. According to the results of fire resistance test, when the dry PF method was applied, the temperature of the main reinforcing bar was 116℃ in 15mm, 103.8℃ in 20mm, and 94℃ in 25mm, and these results satisfied the current standards for fire resistance control presented by the Ministry of Land, Transport and Maritime Affairs. When a 3-hour fire resistance test was performed and the external properties of the specimen were examined, the outermost gypsum board hardly remained and internal PF board maintained its form without thermal strain.

  • PDF

Dynamic Behaviors of Shelly Sand in Cyclic Simple Shear Test (반복단순전단 시험에 의한 패각질 모래의 동적 거동)

  • Yoon, Yeo-Won;Yoon, Kil-Lim;Choi, Jae-Kwon;Kim, Jae-Kwon;Kim, Seung-Hyun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.1358-1366
    • /
    • 2006
  • In order to study the effects of shell contents on the liquefaction resistance of the shelly sand, NGI cyclic simple shear tests were performed for the shelly sands with shell contents of 0%, 5%, 10%, 20% and 30% under the effective vertical stress of 50kPa, 100kPa and 150kPa for 40% and 55% of relative density, respectively. Cyclic simple shear test results showed that for the low effective vertical stress, liquefaction resistance increased rapidly with the increase of shell contents in both 40% and 55% relative density. On the other hand, for the high effective vertical stress, the liquefaction resistance increased slightly in 40% relative density whereas the resistance was almost same in 55% relative density. Liquefaction resistance decreased with increasing effective vertical stress for both 40% and 55% relative density. In the same effective vertical stress and shell contents, liquefaction resistance increased with the increase of relative density of sands.

  • PDF