• 제목/요약/키워드: resistance deterioration

검색결과 423건 처리시간 0.027초

고로슬래그 미분말을 흔입한 고강도콘크리트의 내동해성에 관한 실험적 연구 (Experimental Study on Frost Resistance of High-Strength Concrete Using Granulated Blast-Furnace Slag)

  • 김무한;권영진;강석표;박선규
    • 콘크리트학회논문집
    • /
    • 제12권4호
    • /
    • pp.41-48
    • /
    • 2000
  • This study is to investigate for the frost resistance of high-strength concrete using finely ground granulated blast-furnace slag with experimental parameters, such as water/binder ratio, replacement proportion of granulated blast-furnace slag, air content and methods of curing. The high-strength concrete using granulated blast-furnace slag is effective to resist frost and decrease scaling. The more increasable replacement proportion of granulated blast-furnace slag is, the better the effect is. The high-strength concrete using granulated blast-furnace slag needs hydrating adequately to prevent deterioration by drying in the early curing period. The micro structure of high-strength concrete, increased to the pore number with diameter of 0.03~0.1mm, is changed by using granulated blast-furnace slag, but is presented differently according to water/binder ration and replacement proportion of granulated blast-furnace slag.

Application of Low Voltage High Resistance Grounding in Nuclear Power Plants

  • Chang, Choong-Koo;Hassan, Mostafa Ahmed Fouad
    • Nuclear Engineering and Technology
    • /
    • 제48권1호
    • /
    • pp.211-217
    • /
    • 2016
  • Most nuclear power plants now utilize solid grounded low voltage systems. For safety and reliability reasons, the low voltage (LV) high resistance grounding (HRG) system is also increasingly used in the pulp and paper, petroleum and chemical, and semiconductor industries. Fault detection is easiest and fastest with a solidly grounded system. However, a solidly grounded system has many limitations such as severe fault damage, poor reliability on essential circuits, and electrical noise caused by the high magnitude of ground fault currents. This paper will briefly address the strengths and weaknesses of LV grounding systems. An example of a low voltage HRG system in the LV system of a nuclear power plant will be presented. The HRG system is highly recommended for LV systems of nuclear power plants if sufficient considerations are provided to prevent nuisance tripping of ground fault relays and to avoid the deterioration of system reliability.

폐유리를 혼입한 콘크리트의 황산마그네슘 저항성에 관한 연구 (Magnesium Sulfate Resistance of Concrete Containing Waste Glass)

  • 김영수;정유진;이동운
    • 한국건축시공학회지
    • /
    • 제9권3호
    • /
    • pp.109-116
    • /
    • 2009
  • The magnesium sulfate solution digestion test carried out for resistance of concrete containing waste glass powder on magnesium sulfate attack. Moreover, it yielded S.D.F index was used for the criteria of quantitative assessment to the resistance of magnesium sulfate for the purpose of evaluation of chemical deterioration on concrete. Furthermore, to evaluate for micro-cracks within concrete and external corrosion, the weight variation of specimens and the dynamic elasticity were compared and analyzed and also the applicability was examined using the analysis of product of hydration through out observing external deformation and micro-structural deformation.

고로슬래그를 치환한 보수 모르타르의 내 황산성 평가 (Sulfuric Acid Resistance Evaluation of Repair Mortar Substituted Blast Furnace)

  • 김완수;장종민;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 추계 학술논문 발표대회
    • /
    • pp.25-26
    • /
    • 2019
  • The Reinforced concrete structure is deteriorated in durability due to various deterioration factors such as acid, salt, etc., and thus requires repair and reinforcement. In this study, compressive strength and weight change were measured by substituting blast furnace slag with excellent chemical resistance. As a result, the decrease in compressive strength decreased in proportion to the blast furnace slag substitution rate, and in the case of BFS40, the strength increased after sulfuric acid immersion. The weight change also decreased in proportion to the replacement amount.

  • PDF

비재하 가열실험을 통한 이중강관 CFT기둥의 잔존강도 평가연구 (A Study on the Evaluation of Residual Strength of Double Concrete Filled Tube Column by Unstressed test)

  • 김선희;원용안;최성모
    • 한국강구조학회 논문집
    • /
    • 제24권1호
    • /
    • pp.81-89
    • /
    • 2012
  • 콘크리트 충전강관 기둥은 내부의 콘크리트에 의해 축열효과로 인해 철골기둥에 비해 내화성능이 우수하며, 기둥 단면 내 철근 및 강관을 보강하여 구조적내력 및 내화성능 향상연구가 이루어져 오고 있다. 실제로 보강된 CFT기둥은 고축력을 요구하는 기둥부재로 사용 빈도 수가 증가되고 있는 추세이다. 이러한 상황에서 CFT기둥을 사용한 건축물에 화재가 발생하여 손상을 입게 되었을 경우 성능 저하정도를 정밀하게 측정할 수 있는 기법이 필요하다. 본 연구에서는 화재 발생시 CFT기둥에 대한 내부 온도 분포를 평가 하고, 단면내부의 온도분포에 따라 내부 충전콘크리트와 보강재의 내력 저하 정도를 파악하여 CFT기둥의 전체적인 잔존강도를 평가하고자 한다.

폭렬현상을 고려한 RC구조물의 PBD기반 구조내화설계 기술개발에 관한 연구(I) - 국내외 주요 건설사의 대응방안 - (A Study on the Structural Fire Resistance Performance Design of RC Structural according to the Explosive Spalling(I) - The Countermeasures of General Construction Company -)

  • 이재영;김세종;권영진
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 추계학술논문발표회 논문집
    • /
    • pp.195-201
    • /
    • 2008
  • When reinforced concrete is subjected to high temperature as in fire, there is deterioration in its properties of particular importance are loss in compressive strength, cracking and spalling of concrete, destruction of the bond between the cement paste and the aggregates and the gradual deterioration of the hardend cement paste. Assessment of fire-damaged concrete usually starts with visual observation of color change, cracking and spalling of the surface. In this paper, it was reported the trends of research and practical use on the Explosive Spalling Properties of the High-Strength Concrete.

  • PDF

정전용량 프로브 크기에 대한 엔진오일 상대 유전율 측정 (Measurement Of The Engine Oil Relative Dielectric Constant With Respect To Capacitive Prove Dimension)

  • 김기훈;김영주
    • Tribology and Lubricants
    • /
    • 제27권4호
    • /
    • pp.209-212
    • /
    • 2011
  • The capacitive application(prove) can be used to measure the complex permittivity of dielectric material of various thickness and cross section. This paper presents that we designed the analysis system of engine oil permittivity to know the relation between the engine oil deterioration and the prove dimension. Each of the dimension of capacitive prove is changed and then electric capacity is measured by LCR {Inductance(L), Capacitance (C), and Resistance (R)} meter. The engine oil permittivity has extracted in the prove measurement. As the additional research, this paper suggest the best of the prove dimension for the permittivity measurement.

Strength and durability studies on high strength concrete using ceramic waste powder

  • Karthikeyan, B.;Dhinakaran, G.
    • Structural Engineering and Mechanics
    • /
    • 제61권2호
    • /
    • pp.171-181
    • /
    • 2017
  • This paper summarizes the study on effect of ceramic waste powder as partial substitute to cement in binary blend and along with silica fume in ternary blend high strength concrete in normal and aggressive environments. Strength parameters such as compression & tension and durability indices such as corrosion measurement, deterioration, water absorption and porosity were studied. Ceramic waste powder was used in three different percentages namely 5, 10 and 15 with constant percentage of silica fume (1%) as substitutes to cement in ternary blend high strength concrete was investigated. After a detailed investigation, it was understood that concrete with 15% ceramic waste powder registered maximum performance. Increase of ceramic waste powder offered better resistance to deterioration of concrete.

탄소나노튜브 스마트 복합소재의 전기적 임피던스 변화를 이용한 나노센서의 센싱 특성 연구 (A Study on Sensing Characteristics of Carbon Nanotube Smart Composite Nano Sensors Based on Electrical Impedance Measurement)

  • 강인필
    • 동력기계공학회지
    • /
    • 제13권1호
    • /
    • pp.65-71
    • /
    • 2009
  • To address the need for new intelligent sensing, this paper introduces nano sensors made of carbon nanotube (CNT) composites and presents their preliminary experiments. Having smart material properties such as piezoresistivity, chemical and bio selectivity, the nano composite can be used as smart electrodes of the nano sensors. The nano composite sensor can detect structural deterioration, chemical contamination and bio signal by means of its impedance measurement (resistance and capacitance). For a structural application, the change of impedance shows specific patterns depending on the structural deterioration and this characteristic is available for an in-situ multi-functional sensor, which can simultaneously detect multi symptoms of the structure. This study is anticipated to develop a new nano sensor detecting multiple symptoms in structural, chemical and bio applications with simple electric circuits.

  • PDF

지하 콘크리트 구조물 조인트에 대한 멤브레인 방수시스템의 복합 환경 대응 성능 평가 방법 (Complex Environmental Degradation Resistance Performance Evaluation Method of Membrane Waterproofing Systems for Underground Concrete Structure Joint)

  • 오규환;김병일;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 춘계 학술논문 발표대회
    • /
    • pp.44-45
    • /
    • 2017
  • There are various national standards designed to test the physical properties of waterproofing materials for the respective countries based on each of their environmental parameters, variables and requirements. The problems of these standard systems can be outlined in the following: (1) there are too many test methods and criteria to satisfy in order assess one waterproofing membrane system, and (2) there is currently no known method to compile the separate testing results to provide a comprehensive report on waterproofing system durability. This paper outlines and compares the performance testing results of various types of asphalt waterproofing membrane systems and discusses the potentials of a complex environmental deterioration analysis method.

  • PDF