• Title/Summary/Keyword: resistance detection

Search Result 558, Processing Time 0.031 seconds

Analysis of conductive mechanism on self-diagnosis FRP (자기진단 FRP의 도전기구 해석)

  • 임현주;이학용;신순기;이준희
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2003.04a
    • /
    • pp.27-30
    • /
    • 2003
  • In order to apply fracture detection we fabricated the CP-FRP using carbon-powder and analyzed conductive mechanism of it. The composites showed lower initial resistance as the carbon powder and amount of glass fiber(TEX) was used much more. When those are compared with each other that before and after bending test, the more cracks observed in matrix after bending test. We become to know that the conductivity of the composites depends on percolation structure of carbon powder.

  • PDF

High Impedance Fault Detection using Wavelet Transform (Wavelet 변환을 이용한 고저항 지락고장 검출)

  • Kim, Hyun;Kim, Chul-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.12
    • /
    • pp.1492-1497
    • /
    • 1999
  • High impedance fault(HIF) is defined as fault the general overcurrent relay can not detect or interrupt. Especially when HIF occur in residential areas, energized high voltage conductor results in fire hazard, equipment damage or personal threat. This paper proposes the model of the high impedance fault in transmission line using the ZnO arrester and resistance to be implemented within EMTP. The performance of the proposed model is tested on a typical 154[kV] korean transmission line system under various fault conditions. Wavelet transform is efficient and useful for the detection of high impedance fault in power system, because it uses variable windows according to frequency. In this paper, HIF detection method using wavelet transform can distinguish HIF form similar fault like arcfurance load, capacitor bank switching and line switching.

  • PDF

Development of Fault Detection and Noise Cancellation Algorithm Using Wavelet Transform on Underground Power Cable Systems (웨이블렛을 이용한 지중송전계통 고장검출 및 노이즈 제거 알고리즘 개발)

  • Jung, Chae-Kyun;Lee, Jong-Beom
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.7
    • /
    • pp.1191-1198
    • /
    • 2007
  • In this paper, the fault detection and noise cancellation algorithm based on wavelet transform was developed to locate the fault more accurately. Specially, noise cancellation algorithm was based on the correlation of wavelet coefficients at multi-scales. Fault detection, classification and location algorithm were tested by EMTP simulation on real power cable system. From these results, the faults can be detected and located even in very difficult situations, such as at different inception angle and fault resistance.

Lightweight Intrusion Detection of Rootkit with VMI-Based Driver Separation Mechanism

  • Cui, Chaoyuan;Wu, Yun;Li, Yonggang;Sun, Bingyu
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.11 no.3
    • /
    • pp.1722-1741
    • /
    • 2017
  • Intrusion detection techniques based on virtual machine introspection (VMI) provide high temper-resistance in comparison with traditional in-host anti-virus tools. However, the presence of semantic gap also leads to the performance and compatibility problems. In order to map raw bits of hardware to meaningful information of virtual machine, detailed knowledge of different guest OS is required. In this work, we present VDSM, a lightweight and general approach based on driver separation mechanism: divide semantic view reconstruction into online driver of view generation and offline driver of semantics extraction. We have developed a prototype of VDSM and used it to do intrusion detection on 13 operation systems. The evaluation results show VDSM is effective and practical with a small performance overhead.

Detection of Vancomycin Resistance Genes and Antibiotic Resistance Characteristics of Enterococcus spp. Isolated from Inland Pollution Sources Near Shellfish Farms on the West Coast of South Korea (서해안 패류양식장 인근 육상오염원에서 분리한 장구균의 Vancomycin 내성 유전자 검출 및 항생제 내성 특성)

  • Jeong, Yeon Gyeom;Park, Bo Mi;Hwang, Jin Ik;Kim, Min Ju;Oh, Eun Gyoung
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.55 no.5
    • /
    • pp.505-513
    • /
    • 2022
  • In this study, 143 strains of Enterococcus spp. were isolated from inland pollution sources near shellfish farms on the west coast of South Korea. Not all isolated Enterococcus spp. strains possessed vancomycin resistance genes (VanA and VanB). However, since vancomycin-resistance Enterococcus (VRE) have been detected not only in the clinical field but also out in the world, it is possible that the VRE gene may be transferred to other bacterial strains commonly found in coastal waters where seafood is produced. It is important to monitor trends in the appearance of VRE. In addition, antimicrobial resistance patterns of isolates were examined in this study. Overall antimicrobial resistance rates were high: ciprofloxacin (32.2% of isolates resistant), chloramphenicol (30.8%), quinupristin/dalfopristin (19.6%), and tylosin (15.4%). Eight E. faecium strains (6.2%), out of the 129 strains assessed, showed multidrug resistance. All multidrug-resistant E. faecium showed resistance to erythromycin, quinupristin/dalfopristin, tetracycline, and tylosin, in all 14 strains. All multidrug-resistant E. faecalis showed resistance to erythromycin, quinupristin/dalfopristin, tetracycline, and tylosin. Both multidrug-resistant E. faecium and multidrug-resistant E. faecalis showed common resistance to erythromycin, quinupristin/dalfopristin, tetracycline, and tylosin.

Detection of Inducible Clindamycin Resistance Genes (ermA, ermB, and ermC) in Staphylococcus aureus and Staphylococcus epidermidis

  • Mazloumi, Mohammad Javad;Akbari, Reza;Yousefi, Saber
    • Microbiology and Biotechnology Letters
    • /
    • v.49 no.3
    • /
    • pp.449-457
    • /
    • 2021
  • The aim of the present study was to survey the frequency of inducible and constitutive phenotypes and inducible cross-resistant genes by regulating the methylation of 23S rRNA (ermA, ermB, and ermC) and macrolide efflux-related msrA gene in Staphylococcus aureus and S. epidermidis strains. A total of 172 bacterial isolates (identified based on standard tests), were examined in this study. Antibiotic susceptibility was determined by the disk diffusion method, and all isolates were evaluated with respect to inducible and constitutive phenotypes. The presence of ermA, ermB, ermC, and msrA genes was investigated by a PCR assay. The constitutive resistance phenotypes showed a higher distribution among the isolates. R phenotype was detected more among S. epidermidis isolates (46.25%). ermB, ermC, and msrA genes were detected more in methicillin-resistant S. aureus (MRSA) and methicillin-resistant S. epidermidis (MRSE) isolates that had R and HD phenotypes (>77% strains). The ermA gene had the lowest frequency among MRSA, MRSE, MSSA, and MSSE strains (<14% isolates). Distribution of inducible resistance genes in MRSA and MRSE strains, and possibly other species, leads to increased constitutive resistance to erythromycin, clindamycin, and other similar antibiotics. Therefore, it can be challenging to treat infections caused by these resistant strains.

Analysis on an improved resistance tuning type multi-frequency piezoelectric spherical transducer

  • Qin, Lei;Wang, Jianjun;Liu, Donghuan;Tang, Lihua;Song, Gangbing
    • Smart Structures and Systems
    • /
    • v.24 no.4
    • /
    • pp.435-446
    • /
    • 2019
  • The existing piezoelectric spherical transducers with fixed prescribed dynamic characteristics limit their application in scenarios with multi-frequency or frequency variation requirement. To address this issue, this work proposes an improved design of piezoelectric spherical transducers using the resistance tuning method. Two piezoceramic shells are the functional elements with one for actuation and the other for tuning through the variation of load resistance. The theoretical model of the proposed design is given based on our previous work. The effects of the resistance, the middle surface radius and the thickness of the epoxy adhesive layer on the dynamic characteristics of the transducer are explored by numerical analysis. The numerical results show that the multi-frequency characteristics of the transducer can be obtained by tuning the resistance, and its electromechanical coupling coefficient can be optimized by a matching resistance. The proposed design and derived theoretical solution are validated by comparing with the literature given special examples as well as an experimental study. The present study demonstrates the feasibility of using the proposed design to realize the multi-frequency characteristics, which is helpful to improve the performance of piezoelectric spherical transducers used in underwater acoustic detection, hydrophones, and the spherical smart aggregate (SSA) used in civil structural health monitoring, enhancing their operation at the multiple working frequencies to meet different application requirements.

High Prevalence of Fluoroquinolone- and Methicillin-Resistant Staphylococcus pseudintermedius Isolates from Canine Pyoderma and Otitis Externa in Veterinary Teaching Hospital

  • Yoo, Jong-Hyun;Yoon, Jang-W.;Lee, So-Young;Park, Hee-Myung
    • Journal of Microbiology and Biotechnology
    • /
    • v.20 no.4
    • /
    • pp.798-802
    • /
    • 2010
  • Recently, a total of 74 Staphylococcus pseudintermedius isolates were collected from clinical cases of canine pyoderma and otitis externa in Korea. In this study, we examined in vitro fluoroquinolone resistance among those isolates using a standard disc diffusion technique. The results demonstrated that, except for one isolate, approximately 18.9% to 27.0% of the isolates possessed bacterial resistance to both veterinary- and human-licensed fluoroquinolones including moxifloxacin (18.9% resistance), levofloxacin (20.3% resistance), ofloxacin (24.3% resistance), ciprofloxacin (25.7% resistance), and enrofloxacin (27.0% resistance). Most surprisingly, 14 out of 74 (18.9%) isolates were resistant to all the five fluoroquinolones evaluated. Moreover, a PCR detection of the methicillin resistance gene (mecA) among the 74 isolates revealed that 13 out of 25 (52.0%) mecApositive isolates, but only 7 out of 49 (14.3%) mecA-negative isolates, were resistant to one or more fluoroquinones. Taken together, our results imply that bacterial resistance to both veterinary- and human-use fluoroquinolones becomes prevalent among the S. pseudintermedius isolates from canine pyoderma and otitis externa in Korea, as well as that the high prevalence of the mecA-positive S. pseudintermedius isolates carrying multiple fluoroquinolones resistance could be a potential public health problem.

Self-Diagnosis of Damage in Carbon Fiber Reinforced Composites Using Electrical Residual Resistance Measurement (잉여 전기 저항 측정을 이용한 탄소 섬유 강화 복합재의 파손 측정)

  • Kang, Ji-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.4
    • /
    • pp.323-330
    • /
    • 2009
  • The objective of this research was to develop a practical integrated approach using extracted features from electrical resistance measurements and coupled electromechanical models of damage, for in-situ damage detection and sensing in carbon fiber reinforced plastic(CFRP) composites. To achieve this objective, we introduced specific known damage (in terms of type, size, and location) into CFRP laminates and established quantitative relationships with the electrical resistance measurements. For processing of numerous measurement data, an autonomous data acquisition system was devised. We also established a specimen preparation procedure and a method for electrode setup. Coupon and panel CFRP laminate specimens with several known damage were tested. Coupon specimens with various sizes of artificial delaminations obtained by inserting Teflon film were manufactured and the resistance was measured. The measurement results showed that increase of delamination size led to increase of resistance implying that it is possible to sense the existence and size of delamination. A quasi-isotropic panel was manufactured and electrical resistance was measured. Then three different sizes of holes were drilled at a chosen location. The panel was prepared using the established procedures with six electrode connections on each side making a total of twenty-four electrodes. Vertical, horizontal, and diagonal pairs of electrodes were chosen and the resistance was measured. The measurement results showed the possibility of the established measurement system for an in-situ damage detection method for CFRP composite structures.

Implementation of Film Type Sensor for Synthetic Lube Oil and High Pressure Hydraulic Fluid Leak Detection (합성 윤활유 및 고압 작동유 누출감지 필름형 센서의 구현)

  • Park, No-Jin;Yu, Dong-Kuen;Yu, Hong-Kuen
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.4
    • /
    • pp.266-271
    • /
    • 2014
  • Chemical sensors are used in various industrial facilities such high-risk and prevent the leakage of substances, important in life and environmental protection and the safe use of industry, used for management. In particular, high-temperature environments such as power generation equipment of the rotating part due to leakage generated by the various oil, power plants Shut Down, fire, work environment (exposure to various chemical solution and gas leak) and various water, air and soil pollution causes. Thus, over the long term through various channels such as crops and groundwater contamination caused by the slow, serious adverse effect on the ecosystem. In this paper, synthetic lube oil and high pressure hydraulic fluid leakage and immediately detect a new Printed Electronic implementation of technology-based film-type sensors, and its performance test. Thus, industrial accidents and environmental pollution and for early detection of problems, large accidents can be prevented. Experimental results of the synthetic lube oil and high pressure hydraulic fluid solution after the contact time depending on the experiment and the oil solution of the sensor material of the conductive porous PE resistance value by a chemical reaction could be confirmed that rapid increase. Also implemented in the film-type oil sensor electrical resistance change over time of the reaction rate and the synthetic lube oil is about 2 minutes or less, the high pressure hydraulic fluid is less than about 1 minute was. Therefore, more high-pressure hydraulic fluid such as a low volatility synthetic lube oils are the resistance change and the reaction rate was confirmed to be the slowest.