• Title/Summary/Keyword: resistance change

Search Result 2,426, Processing Time 0.032 seconds

Performance Evaluation of High Strength Concrete with Composite Fibers in Accordance with High Temperature (복합섬유가 혼입된 고강도 콘크리트의 고온가열에 따른 성능 평가)

  • Kim, Seung-Ki;Kim, Woo-Suk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.6
    • /
    • pp.63-71
    • /
    • 2015
  • The objective of the present study is to investigate how elevated temperature ranging from $100^{\circ}C$ to $800^{\circ}C$ as well as room temperature affects the variation of mechanical properties of high strength concrete ($over\;f_{ck}=60MPa\;grade$). In this experiment, specimens were exposed for a period of $2^{\circ}C/min$ to temperatures of $20^{\circ}C$, $100^{\circ}C$, $200^{\circ}C$, $300^{\circ}C$ $400^{\circ}C$, $500^{\circ}C$, $600^{\circ}C$, $700^{\circ}C$ and $800^{\circ}C$, respectively. Accordingly, the study investigated the fire resistance performance of high strength concrete mixed with composite fibers which composed with hybrid fibers and steel fibers. After cooling down to ambient temperature, the following basic mechanical properties were then evaluated and compared with reference values obtained prior to thermal exposure: (i) compressive strength in room temperature; (ii) residual compressive strength; (iii) Poisson's ratio; (iv) weight change; (v) SEM analysis & XRD analysis In addition, XRD and SEM Images analyses were performed to investigate chemical and physical characteristics of high strength concrete with composite fibers according to high temperature.

A Study on Heat Transfer Characteristics of a Closed Two-Phase Thermosyphon with a Low Tilt Angle (낮은 경사각을 갖는 밀폐형 2상 열사이폰의 열전달 특성에 관한 연구)

  • 김철주;강환국;김윤철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.1
    • /
    • pp.1-12
    • /
    • 1996
  • In lots of application to heat exchanger systems, closed two-phase thermosyphons are tilted from a horizontal. If the tilt angle, especially, is less than 30$^{\circ}$, the operational performances of thermosyphon are highly dependent on tilt angle. The present study was conducted to better understand such operational behaviors as mech-anni는 of phase change, and flow patterns inside a tilted thermosyphon. For experiment, an ethanol thermosyphon with a 35% of fill charge rate was designed and manufactured, using a copper tube with a diameter 19mm and a length 1500mm. Through a series of test, the tilt angle was kept constant at each of 4 different values in the range 10~25deg. and the heat supply to the evaporator was stepwisely increased up to 30㎾/$m^2$. When a steady state was established to the thermosyphon for each step of thermal loads, the wall temperature distribution and vapor temperature at the condenser were measured. The wall temperature distributions demonstrated a formation of dry patch in the top end zone of the evaporator, with a values of temperature 20~4$0^{\circ}C$ higher than the wetted surface for a moderate heat flux q≒20㎾/$m^2$. Inspite of the presence of hot dry patch, however, the mean values of boiling heat transfer coefficient at the evaporator wall were still in a good agreement with those predicted by Rohsenow's formula, which was based on nucleate boiling. For the condenser, the wall temperatures were practically uniform, and the measured values of condensation heat transfer coefficient were 1.7 times higher than the predicted values obtained from Nusselt's film condensation theory on tilted plate. Using those two expressions, a correlation was formulated as a function of heat flux and tilt angle, to determine the total thermal resistance of a tilted thermosyphon. The correlation formula showed a good agreement with the experimental data within 20%.

  • PDF

Assessment of β-Lactamase Inhibitor Potential of Medicinal Plant Extracts against Antibiotic-resistant Staphylococcus aureus

  • Dawan, Jirapat;Ahn, Juhee
    • Korean Journal of Plant Resources
    • /
    • v.33 no.6
    • /
    • pp.578-585
    • /
    • 2020
  • This study was designed to assess the possibility of using medicinal plant extracts as β-lactamase inhibitors to control antibiotic-resistant Staphylococcus aureus. The susceptibilities of S. aureus ATCC 15564 (SAWT), ciprofloxacininduced S. aureus ATCC 15564 (SACIP), oxacillin-induced S. aureus ATCC 15564 (SAOXA), and clinically-isolated S. aureus CCARM 3008 (SACLI) to ampicillin were determined in the absence and presence of medicinal plant extracts, including Cleyera japonica (CJ), Carpinus laxiflora (CL), Euphorbia helioscopia (EH), Euscaphis japonica (EJ), Oenothera erythrosepala (OE), and Rosa multiflora (RM). The phenotypic change in the clear inhibition zones around ampicillin disc was observed for SAWT, SACIP, and SAOXA, indicating the production of ampicillinase. Compared to the controls, the MICs of ampicillin against SAWT, SACIP, and SAOXA were decreased from 4 to 0.5 ㎍/mL in the presence of CL, 16 to 4 ㎍/mL in the presence of RM, and 32 to 2 ㎍/mL in the presence of CL, EH, and RM, respectively. The medicinal plant extracts, OE, EJ, and CL, effectively inhibited the β-lactamase activities of SAWT (78%), SACIP (57%), and SAOXA (76%) when compared to the control. This results suggest that the medicinal plant extracts can be used as BLIs to control the antibiotic-resistant S. aureus.

A Study of the recognitive element in the interior design of the private railroad station buildings. (철도민자역사 실내 환경디자인의 인지적 구성요소에 대한 접근 연구)

  • Kim Sang-Joong;Choi Kil-Dong;Kim Seong-Nam
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1718-1724
    • /
    • 2004
  • A station is not only the public space where socially diverse classes get together and cultural interchanges occur but also the personal and emotional space where the meeting and parting occur for each individual. Thus, it is necessity to consider this dual point from the beginning of the plan to make the simple, comfortable, intuitive and friendly environment for the users in the station. Also, it should be capable of active life style of moderner according to the change of the city environment. Furthermore, as a station is not just a single-purpose space anymore but the versatile space where fulfills the user's needs for the multi-function and the desire for diversity. As the station in these days opened 24 hours for users with the modern, commercial and cultural facilities, the interior design for a station needs to be designed to be easy to use, functional and able to vitalize the environment. In order to make a desirable interior environment in a station, first of all, it is required to grasp the characteristic of the space by analyzing the phenomena of an individual or a group act in a existing space formed by the interrelation between the human and the environment. To reduce the resistance against the new environment from the user, in other words, to increase the satisfaction, it is necessity to induce the behavior of the users to the desirable way toward to the new environment. Consequently, positive methodology with recognitive approach through cognitive psychology, spatial behavior research is required.

  • PDF

Implementation of Simplified Electronic Measuring Devices Using Java Applets (자바 애플릿을 이용한 단순화된 전자계측장비의 구현)

  • Kim, Dongsik;Moon, Ilhyun;Woo, Sangyeon
    • The Journal of Korean Association of Computer Education
    • /
    • v.10 no.6
    • /
    • pp.69-77
    • /
    • 2007
  • In this paper we implement main functions of electronic measuring devices, which are essential to design electric/electronic virtual laboratories on the Web. The implemented virtual electronic measuring devices such as virtual analog multimeter(VAM), virtual function generator(VFG), virtual oscilloscope(VOSC) enable the learners to perform the virtual experiments on the Web by simple mouse clicks. In order to show their validity virtual experiments for understanding how to use them are designed. The virtual experiments for measuring resistance(OHM), AC/DC Voltage(ACV/DCV) and DC Current(DCA) by the VAM are illustrated. In addition, the learners can change the frequency of the signal generated from the VFG and measure by the VOSC several types of the signals generated from the VFG such as triangular, pulse, sinusoidal waveforms. The VOSC can measure voltage and current through two channels of it and provide the learners with additional functions such as zooming, trigger, cursor, summing of waveforms. Since the virtual electronic measuring devices have been implemented as forms of Java classes, various types of applications are available according to the structures of virtual laboratories.

  • PDF

Studies on Extrinsic Resistance Extraction Method of PHEMT Using Bias-Dependence of Impedance (바이어스에 따른 임피던스 특성을 이용한 PHEMT의 기생 저항 추출방법에 관한 연구)

  • Park, Duk-Soo;An, Dan;Rhee, Jin-Koo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.41 no.2
    • /
    • pp.59-64
    • /
    • 2004
  • In this paper, a Cold PHEMT equivalent circuit was proposed, and it is applied to extract extrinsic resistances. By using the proposed Cold PHEMT equivalent circuit, the variation of impedance with frequency and bias were mainly emphasized. Especially, the convergence of impedance with frequency and the change in impedance with bias were carefully analyzed, which may be used for fast extraction of extrinsic resistances. The proposed extraction method demonstrated improving of small signal model accuracy than conventional extraction method.

Characterizations on the Thermal Insulation of SiC Coated Carbon-Carbon Composites (탄화규소로 코팅된 탄소-탄소 복합재료의 단열 특성)

  • Seo, Hyoung-IL;Lim, Byung-Joo;Sihn, Ihn Cheol;Bae, Soobin;Lee, Hyung-Ik;Choi, Kyoon;Lee, Kee Sung
    • Composites Research
    • /
    • v.33 no.3
    • /
    • pp.101-107
    • /
    • 2020
  • This study investigates the characterization on the thermal insulation properties of silicon carbide coating on the Cf-C composites. The silicon carbide coatings by chemical vapor deposition on the C/C composites are prepared to evaluate thermal resistance. Firstly, we perform the basic insulation test by thermal shock at 1350℃ in air on the C/C composite and SiC-coated C/C composite. We also performed the burner tests on the surface of the composites at high temperatures such as 1700 and 2000℃, and the weight change after burner tests are measured. The damages on the surface of C/C composite and SiC-coated composite are observed. As a result, the SiC coating is beneficial to protect the C/C composite from high temperature even though damages such as defoliation, crack and voids are observed during burner test at 2000℃.

Properties of Fire Resistance in Tunnel Concrete According to the Changes of Heating Curve (온도가열곡선 변화에 따른 콘크리트의 내화특성)

  • Pei, Chang-Chun;Noh, Sang-Kyun;Lee, Chan-Young;Lee, Jong-Suk;Lee, Jang-Hwa;Han, Cheon-Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.705-708
    • /
    • 2008
  • To obtain tunnel concrete safety in case of fire, this study analyzed fire proof characteristics by fire proof method change, and the results are as follows. As a fire proof characteristics by RABT temperature heating curve, plain concrete experienced severe spalling by initial extremely high temperature. In view of fire proof method, in the cases of organic fiber mixing method and board method, spalling was prevented, and in the case of spray method, severe spalling of over 100mm depth occurred along with exposure of structural concrete including spray coat by heat stress, etc while metal lath, the stiffener, falls off. As for fire proof characteristics by RWS temperature heating curve, in case of organic fiber inclusion, concrete surface experienced fusion of within 5mm, while in the case of spray method, spray coat was severely spalled to a depth of over 100mm causing structural body concrete to expose its reinforcement, and also in the case of board method, board was fused by high temperature, causing structural body concrete be directly exposed to high temperature, which triggered overall fall-off phenomenon, so in such extraordinary high temperature heating condition, establishment of special fire proof measures is needed.

  • PDF

3-D Dynamic Response Characteristics of Seabed around Composite Breakwater in Relation to Wave-Structure-Soil Interaction (파랑-구조물-지반 상호작용에 의한 혼성제 주변 해저지반의 3차원 동적응답 특성)

  • Hur, Dong-Soo;Park, Jong-Ryul;Lee, Woo-Dong
    • Journal of Ocean Engineering and Technology
    • /
    • v.30 no.6
    • /
    • pp.505-519
    • /
    • 2016
  • If the seabed is exposed to high waves for a long period, the pore water pressure may be excessive, making the seabed subject to liquefaction. As the water pressure change due to wave action is transmitted to the pore water pressure of the seabed, a phase difference will occur because of the fluid resistance from water permeability. Thus, the effective stress of the seabed will be decreased. If a composite breakwater or other structure with large wave reflection is installed over the seabed, a partial standing wave field is formed, and thus larger wave loading is directly transmitted to the seabed, which considerably influences its stability. To analyze the 3-D dynamic response characteristics of the seabed around a composite breakwater, this study performed a numerical simulation by applying LES-WASS-3D to directly analyze the wave-structure-soil interaction. First, the waveform around the composite breakwater and the pore water pressure in the seabed and rubble mound were compared and verified using the results of existing experiments. In addition, the characteristics of the wave field were analyzed around the composite breakwater, where there was an opening under different incident wave conditions. To analyze the effect of the changed wave field on the 3-D dynamic response of the seabed, the correlation between the wave height distribution and pore water pressure distribution of the seabed was investigated. Finally, the numerical results for the perpendicular phase difference of the pore water pressure were aggregated to understand the characteristics of the 3-D dynamic response of the seabed around the composite breakwater in relation to the water-structure-soil interaction.

Hardening properties of MMA Monomer Using EPS in addition of Initiator and Promoter (개시제 및 촉진제의 첨가에 따른 EPS 혼입 MMA 수지의 경화특성)

  • Lee, Jung-Hui;Song, Hun;Chu, Yong-Sik;Lee, Jong-Kyu
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.929-932
    • /
    • 2008
  • The unsaturated polyester(UP) and epoxy resin have a superior material properties and a chemical resistance using sewerage pipes rehabilitation. However, UP and epoxy have not a low temperatures harding, the requirement $8{\sim}11$ hours long times harding and heating system used by reinforcement liner. This study is to evaluate the effects of low temperature harding properties methyl methacrylate(MMA) monomer using expanded polystyrene(EPS) in addition of initiator and promoters. From the test result, viscosity tends to increase with increasing EPS contents. However, harding time change of the MMA resins which it follows in addition of the initiator and promoter.

  • PDF