• Title/Summary/Keyword: resistance change

Search Result 2,426, Processing Time 0.035 seconds

Comparision of Heat Exchanging Performance Depending on Different Arrangement of Heat Exchanging Pipe (II) (열회수장치의 열교환 파이프배치형식별 열교환 성능 비교(II))

  • Suh, Won-Myung;Kang, Jong-Guk;Yoon, Yong-Cheol;Kim, Jung-Sub
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.281-285
    • /
    • 2001
  • This study was carried out to improve the performance of heat recovery device attached to exhaust gas flue connected to combustion chamber of greenhouse heating system. Three different units were prepared for the comparison of heat recovery performance; AB-type(control unit) is exactly the same with the typical one fabricated for previous study of analyzing heat recovery performance in greenhouse heating system, other two types(C-type and D-type) modified from the control unit are different in the aspects of airflow direction(U-turn airflow) and pipe arrangement. The results are summarized as follows; 1. In the case of Type-AB, when considering the initial cost and current electricity fee required for system operation, it is expected that one or two years at most would be enough to return the whole cost invested. 2. Type-C and Type-D, basically different with Type-AB in the aspect of airflow pattern, are not sensitive to the change of blower capacity with higher than $25\;m^{3}/min$. Therefore, heat recovery performance was not improved so significantly with the increment of blower capacity. This is assumed to be that air flow resistance in high air capacity reduces the heat exchange rate as well. Never the less, compared with control unit, resultant heat recovery rate in Type-C and Type-D were improved by about 5% and 13%, respectively. 3. Desirable blower capacity for these heat recovery units experimented are expected to be about $25\;m^{3}/min$, and at the proper blower capacity, U-turn airflow units showed better heat recovery performance than control unit. But, without regard to the type of heat recovery unit, it is recommended that comprehensive consideration of system's physical factors such as pipe arrangement density, unit pipe length and pipe thickness, etc., are required for the optimization of heat recovery system in the aspects of not only energy conservation but economic system design.

  • PDF

Attenuator using Lossy Left-Handed Transmission Line and Vector Modulator Application (손실이 있는 Left-Handed 전송선로를 이용한 감쇠기와 벡터 변조기 응용)

  • Kim, Seung-Hwan;Kim, Ell-Kou;Kim, Young;Yoon, Young-Chul
    • Journal of Advanced Navigation Technology
    • /
    • v.13 no.3
    • /
    • pp.399-405
    • /
    • 2009
  • This paper proposes a design of attenuator based on meta-material structure and its application. The unit-cell attenuator based on the lossy transmission line consists of the CRLH(Composite Right/Left Handed) transmission line and PIN diodes to be controlled internal loss according to diode bias voltage to change resistance of diode. Also, to reduce the initial losses, there is used parallel connection of PIN diodes. To increase attenuations, it is connected a cascade unit-cell of attenuator with periodic structure. The attenuation quantities of unit-cell are about 10dB and phase variations are 15o maximum at 1.5 GHz ~ 2.5 GHz. Also, its application is represented a vector modulator.

  • PDF

Cardiac Performance of Turtle Heart in Various pH of Perfusate (자라에서 본 관류액(灌流液) pH와 심장박출량(心臟搏出量))

  • Yang, Il-Suk
    • The Korean Journal of Physiology
    • /
    • v.9 no.1
    • /
    • pp.69-76
    • /
    • 1975
  • Cardiac performances were analyzed in intact turtle heart(Amyda japonica), perfusing with turtle Ringer-Locke's solution containing various hydrogen ion concentration, at several levels of arterial and venous pressure. 1. Ventricular work increased when venous pressure, or venous filling pressure increased, and also increased when arterial pressure increased. 2. The higher the arterial pressure, the lower the cardiac to output, for arterial pressure is the resistance to the ventricular blood flow. On the other hand, in specific arterial pressure, cardiac output was proportional to the venous filling pressure. 3. Heart rates did not change significantly during the perfusion with Ringel· solution of various pH. 4. In the heart Perfused with Ringer solution of various pH, ventricular work was the highest at PH 7.6 (at 6 $cmH_2O$ arterial pressure and 8 $cmH_2O$ venous pressure, the ventricular work was 63.09m$\cdot$cm). However, within the range of pH $7.1{\sim}7.6$, there were no significant changes in cardiac output and ventricular work. Below the level of pH 7.0, ventricular work decreased to less than 56% of maximium value (at $6cmH_2O$ arterial pressure and $8cmH_2O$ venous Pressure, ventricular work was 36.0$gm{\cdot}$ at pH 7.0). At pH 7.7 ventricular work decreased to less than 48% of maximum value (ventricular work: 30.0 $gm{\cdot}$). The nature of the cardiac performance at the various arterial and venous pressures was similar to that of normal heart. 5. Turtle heart seemed to be relatively insensitive to acid-base disturbances. The mechanism of negative inotropic effect of hydrogen ion was discussed.

  • PDF

Charge-discharge capacity and AC impedance of $LiMn_{2-y}M_{y}O_{4}$(M=Mg, Zn) cathode ($LiMn_{2-y}M_{y}O_{4}$(M=Mg, Zn) 정극의 충방전 용량 및 AC 임피던스 특성)

  • 정인성;위성동;이승우;구할본
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.455-458
    • /
    • 2001
  • Spinel $LiMn_{2-y}$$M_{y}$ $O_4$powder was prepared solid-state method by calcining the mixture of LiOH - $H_2O$, Mn $O_2$, ZnO and MgO at 80$0^{\circ}C$ for 36h. To investigate the effect of substitution with Mg, Zn cation, charge-discharge experiments and initial impedance spectroscopy performed. The structure of $LiMn_{2-y}$$M_{y}$ $O_4$crystallites was analyzed from powder X-ray diffraction data as a cubic spinel, space group Fd3m. all cathode material showed spinel phase based on cubic phase in X-ray diffraction. Ununiform which calculated by (111) face and (222) face was constant in spite of the change of y value, except PUf\ulcorner LiM $n_2$ $O_4$. The discharge capacities of the cathode for the cation subbstitUtes $LiMn_{2-y}$$M_{y}$ $O_4$/Li cell at the 1st cycle and at the 40th cycle were about 120~124 and 108~112mAh/g except LiM $n_{1.9}$Z $n_{0.1}$ $O_4$/Li cell, respectively. This cell capacity is retained by 93% after 40th cycle. AC impedance of $LiMn_{2-y}$$M_{y}$ $O_4$/Li cells revealed the similar resistance of about 65~110$\Omega$ before cycling. before cycling.g.g.

  • PDF

Electrical Properties as the ratio of ZnO/$Mn_3$$O_4$ of NTC Thermistor with $Mn_3$$O_4$-NiO-CuO-$Co_3$$O_4$-ZnO system for Inrush Current Limited (돌입전류 제한용 $Mn_3$$O_4$-NiO-CuO-$Co_3$$O_4$-ZnO계 NTC 써미스터에서 ZnO/$Mn_3$$O_4$비에 따른 전기적 특성)

  • 윤중락;김지균;권정렬;이현용;이석원
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.6
    • /
    • pp.472-477
    • /
    • 2000
  • Oxides of the form Mn$_{4}$/O$_{4}$-CuO-Co$_{3}$/O$_{4}$-NiO-ZnO present properties that make them useful as power NTC thermistor for current limited. Electrical properties of Mn$_{3}$/O$_{4}$-CuO-Co$_{3}$/O$_{4}$-CuO-Co$_{3}$/O$_{4}$-NiO-ZnO power NTC thermistor such as I-V characteristics tim constant activation energy and heat dissipation coefficient measured as a function of temperature and composition. In Mn$_{4}$/O$_{4}$-CuO-Co$_{3}$/O$_{4}$-NiO-ZnO system with the 5wt% addition of Co$_{3}$/O$_{4}$ it can be seen that resistivity and B-constant were increased as the ratio of ZnO/Mn$_{3}$/O$_{4}$ was increased. Heat dissipation constant, I-V characteristics and time constant showed similar behaviour compared with those of conventional thermistors. In particular resistance change ratio ($\Delta$R) the important factor for reliability varied within $\pm$5% indicating the compositions of these products could be available for power thermistor.

  • PDF

Nucleation and growth mechanism of nitride films deposited on glass by unbalanced magnetron sputtering

  • Jung, Min J.;Nam, Kyung H.;Han, Jeon G.
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2001.06a
    • /
    • pp.14-14
    • /
    • 2001
  • Nitride films such as TiN, CrN etc. deposited on glass by PVD processes have been developed for many industrial applications. These nitride films deposited on glass were widely used for not only decorative and optical coatings but also wear and corrosion resistance coatings employed as dies and molds made of glass for the example of lens forming molds. However, the major problem of nitride coatings on glass by PVD process is non-uniform film owing to pin-hole and micro crack. It is estimated that nonuniform coating is influenced by a different surface energy between metal nitrides and glass due to binding states. In this work, therefore, for the evaluation of nucleation and growth mechanism of nitride films on glass TiN and CrN film were synthesized on glass with various nitrogen partial pressure by unbalanced magnetron sputtering. Prior to deposition, for the examination of relationship between surface energy and film microstructure plasma pre-treatment process was carried out with various argon to hydrogen flow rate and substrate bias voltage, duty cycle and frequency by using pulsed DC power supply. Surface energy owing to the different plasma pre-treatment was calculated by the measurement of wetting angle and surface conditions of glass were investigated by X-ray Photoelectron Spectroscopy(XPS) and Atomic Force Microscope(AFM). The microstructure change of nitride films on glass with increase of film thickness were analyzed by X-Ray Diffraction(XRD) and Scanning Electron Microscopy(SEM).

  • PDF

Evaluation on Fire Test for the Concrete Filled Steel Tube Column -Fire Damage Evaluation on Steel Tube and Concrete after a Fire Test- (콘크리트충전 강관기둥의 내화실험에 대한 고찰 -재하가열실험후의 강관 및 콘크리트 화재손상평가를 중심으로-)

  • Park, Ki-Chang;Choi, Sung-Mo;Kim, Dong-Kyu
    • Journal of Korean Society of Steel Construction
    • /
    • v.12 no.6
    • /
    • pp.759-767
    • /
    • 2000
  • In this study, the time dependent internal stress changes of a Concrete Filled Steel Tube(CFT) column during a fire test were quantitatively analyzed. The strain ratio of a CFT column on the different loads was measured by tensile strength tests in terms of yield strength, tensile strength average extensibility and elasticity modulus. To understand the internal material properties change of concrete in CFT column damaged due to a fire, the compressive strength and elastic modulus tests were measured on a core sample from the center of the steel tube after the fire test. The elastic modulus test measured the strain from the stress. To determine the fire temperature of the test material, a differential thermal analysis was done. From the tested result, the gained data were conducted and an analysis method was suggested. The purpose of this work is to suggest a basic data for structure regulation enactments of the internal fire design of CFT.

  • PDF

Fashion Design Study on Korean Traditional Image Suitable for Ramie Fabric(I) - The Application of Aesthetic Property of Goguryeo Era Clothing - (모시 소재에 적합한 한국적 이미지의 의상디자인 개발에 대한 연구(제1보) - 고구려 시대 복식의 미적 특징을 적용하여 -)

  • Lee, Mi-Yeon;Lee, Kun-Hee
    • The Research Journal of the Costume Culture
    • /
    • v.16 no.1
    • /
    • pp.130-144
    • /
    • 2008
  • A recent concern about Goguryeo era reflects the efforts to find out our spiritual roots, which have descended from the ancient times; Goguryeo clothing study leads to analysis of our national spirit in terms of form. This study aims to analyze formal property and intrinsic meaning of Goguryeo clothing for Korean ramie clothing design and draw traditional images to derive design elements applicable to ramie clothing. On the basis of technical books, newspaper article, internet and precedent studies, theoretical study on Goguryeo clothing and ramie property was followed up with positive study to analyze the clothing on the Goguryeo ancient tomb mural. The results are as follows: First, a progressive spirit is to progress and develop anything actively; This spirit represents Goguryeo people's ambition and racial characteristic as horse-riding people; The rigidity of ramie fabric is suitable for expressing straight silhouettes and detail in Goguryeo dress. Second, a fluidity means flowing property in opposition to fixation; in the case of clothing, it has a tendency to change form according to body motions; The extensibility and crease-resistance of ramie fabric is suitable to express pleated skirts and holds high design value for modern people who tend to regard clothing as important individuality expression. Third, a universal property to introduce and receive; as Goguryeo was a prosperous country established by conquering an open plain, the period formed a society that recognized diversity by introducing foreign cultures freely; a universality suggests the direction of modernization of traditional ramie clothing and stimulates us to discovert new design through compromise between various cultures rather than to stick to traditional style. Considering the fact that precedent studies on traditional clothing are concentrated upon the Joseon period and also limited to formal analysis, this study aims to derive design elements for actual clothing making. These results are expected to be used as basic material for study as well as reference for designers who wish to design modern Korean clothing.

  • PDF

A Study on the Sulfur-Resistant Catalysts for Water Gas Shift Reaction II. Effect of Alkali Metal Salt on the Activity of CoMo Catalyst (황에 저항성을 가지는 수성가스 전환반응 촉매의 연구 II. CoMo 촉매의 활성에 미치는 알칼리 금속염의 영향)

  • Kim, Joon Hee;Lee, Ho In
    • Journal of the Korean Chemical Society
    • /
    • v.42 no.6
    • /
    • pp.696-702
    • /
    • 1998
  • The effect of alkali metal salt on the activity of Co-Mo catalyst which has high resistance to sulfur poisoning for water gas shift reaction(WGSR) was studied. Two groups of catalysts were prepared to investigate the effects of anion and cation in alkali metal salts. For K-doped catalysts made with various potassium salts having different anion, the catalytic activity was explained to depend mainly on the BET surface area. Among the catalysts prepared by various nitrates of alkali metal as precursor, the Li-doped catalyst showed the best activity, and the others did not make significant differences giving relatively low activities. And the change of BET surface area by varying the loading of alkali metal showed a similar trend to that of activity. In this case, the activity was dependent on both BET surface area and the ratio of $Mo^{6+}$ with a tetrahedral coordination symmetry to $Mo^{6+}$ with an octahedral one, $Mo^6+[T]/Mo^{6+}[O]$ value.

  • PDF

Electrochemical Properties of Polypyrrole/Polyfuran Polymer Composite Electrode (피롤/퓨란 고분자 복합체 전극의 전기화학적 성질)

  • Cha, Seong Keuck
    • Journal of the Korean Chemical Society
    • /
    • v.42 no.6
    • /
    • pp.664-671
    • /
    • 1998
  • Poly pyrrole polymer(ppy) has an excellent electrical conductivity and can be easily polymerized on anode to give various morophology according to doped anion on electroactive sites. To improve the properties of brittleness, ageing and hydrophobisity, poly furan polymer(pfu) having a high initiation potential was anodically implanted in this porous ppy film matrix to get the Pt/ppy/pfu(x)type of polymer composite electrode. Cyclic voltammetry and electrochemical impedance methods were used to these electrode, where $PF_6^-,\; BF_4^-$, and $ClO_4^-$ ions were employed as dopants. The composition of the pfu(x) at the electrode was changed from 0 to 1.10, but the range was useful only at 0.1 to 0.2 as the redox electrode. The polymer composite electrode doped with $PF_6^-$ was better in charge transfer resistance by a factor of 40 times and in double layer capacitance by a factor of 20 times than others. The charge transfer in the polymer film of the electrode was influenced on frequency change and equivalent circuit of this electrode had Warburg impedance including mass transfer.

  • PDF