• 제목/요약/키워드: resistance capacity

검색결과 1,649건 처리시간 0.032초

고로슬래그 미분말을 사용한 고유동콘크리트의 내동해성에 관한 실험적 연구 (An Experimental Study on the Frost Resistance of High-Flowing Concrete Using Granulated Blast-Furnace Slag)

  • 김무한;권영진;강석표
    • 콘크리트학회논문집
    • /
    • 제12권2호
    • /
    • pp.43-51
    • /
    • 2000
  • This study is to investigate for the frost resistance of high-flowing concrete using finely ground granulated blast-furnace slag with experimental parameters, such as type of binder, type of superplasticizer and method of curing. The resistance to freezing and thawing of high-flowing concrete by type of binder and superplasticizer is presented differently. Though the frost resistance of high-flowing concrete is satisfactory under standard condition, it is required that high-flowing concrete has entrained air like plain concrete. Because the critical spacing factor, being capacity of frost resistance, of high-flowing concrete is longer that of plain concrete, the frost resistance of high-flowing concrete, using finely ground granulated furnace blast slag, is superior to that of plain concrete.

3상 초전도케이블의 불평형 부하운전시 열.전류 저항에 의한 운전특성연구 (A Study on the operational characteristics of Thermal.Current Resistance of 3 phase HTS Cable under Unbalanced load operation)

  • 이근준;황시돌;이현철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.189-1-190-1
    • /
    • 2008
  • A high temperature superconducting(HTS) power cable is available for high capacity current in normal condition. But resistance was appeared to operate unbalance load by thermal current characteristic. This characteristic of HTS power cable used to design for unstated condition. And than, It used to understand and analyze characteristic of power cable thermal and critical current. This study appeared that quench resistance reason from shield and former current rise to superconductor(SC) current. The resistance of SC occurred that the cable temperature rise to fault current after decreased critical current. The quench resistance of SC increased in temperature or decreased in critical current. So the quench resistance of SC correlated with resistance of both shield and former current. It need to sufficiently influenced the parameters of HTS cable design.

  • PDF

780 MPa급 TRIP강의 저항 점용접부 강도 및 파단에 미치는 Paint Baking의 영향 (Effect of Paint Baking on the Strength and Failure of Spot Welds for 780 TRIP Steels)

  • 손종우;남대근;김동철;박영도
    • Journal of Welding and Joining
    • /
    • 제28권2호
    • /
    • pp.66-73
    • /
    • 2010
  • Conventional fracture test of resistance spot weld had been performed without consideration of paint baking process in automobile manufacturing line. This study was aim to investigate the effect of paint baking on fracture mode and load carrying capacity in fracture test for resistance spot welded 780TRIP steels. With paint baking cycle after resistance spot welds, peel tests and microhardness were conducted on the as-welded and baked samples. Resistance spot welds in AHSS (Advanced High Strength Steels) are prone to display partial interfacial fractures during fracture test or vehicle crash. Baking cycle increased the load-carrying capacity of the resistance spot welded samples and improved the fracture appearance from partial to full button fracture for the L-type peel tests. Specially, the differences in fracture appearance are apparent when the nugget size of spot welds is small enough to produce the partial interfacial fracture. The comparison of macrohardness and microstructure between as-welded and baked samples showed that there are no large difference in change the fracture mode. However, the results of the instrumented indentation test suggested that fusion zone and HAZ of baked sample have less tensile and yield strength and proves that the tempering effects are applied and enhanced the resistance to fracture on welds with application of baking cycle.

내진성능평가시 횡보강근이 없는 RC 보-기둥 접합부의 전단내력 평가 (Seismic Assessment of Shear Capacity of RC Beam-Column Joints Without Transverse Re-bars)

  • 이영욱
    • 한국지진공학회논문집
    • /
    • 제23권5호
    • /
    • pp.249-259
    • /
    • 2019
  • To study the seismic resistance of the shear capacity of the RC beam-column joints of two-story and four-story RC buildings, sample buildings are designed with ordinary moment resisting frame. For the shear capacity of joints, the equations of FEMA 356 and NZ seismic assessment are selected and compared. For comparison, one group of buildings is designed only for gravity loads and the other group is designed for seismic and gravity loads. For 16 cases of the designed buildings, seismic performance point is evaluated through push-over analysis and the capacity of joint shear strength is checked. Not only for the gravity designed buildings but also for seismic designed buildings, the demand of joint shear is exceeding the capacity at exterior joints. However, for interior joint, the demand of joint shear exceeds the capacity only for one case. At exterior joints, the axial load stress ratio is lower than 0.21 for gravity designed buildings and 0.13 for seismic designed buildings.

등가변형을 이용한 테이터 말뚝의 지지력 산정 (Estimation of Axial toad Capacity for Tapered Piles Using Equivalent Transformation)

  • 전성남;서경범;송원준;이준환
    • 한국지반공학회논문집
    • /
    • 제25권8호
    • /
    • pp.57-64
    • /
    • 2009
  • 본 연구에서는 등가변형을 이용하며 테이퍼 말뚝의 지지력을 산정하는 방법을 제안하였다. 지반조건과 테이퍼각도를 고려하여 지지력을 산정하던 기존의 방법과 달리, 테이퍼말뚝의 지지력산정시 콘관입시험 결과를 활용하도록 하였다. 이때 테이퍼말뚝은 등가변형을 이용하여 형태를 단순화 시켰으며 이를 통해 실무에서 비교적 쉽게 지지력을 산정 할 수 있는 방법을 제안하였다. 제안된 방법의 검증을 위해 실내시험과 현장시험을 실시하였다. 실내모형시험 결과로부터 측정된 극한지지력과 본 연구에서 제안된 방법에 의한 예측값을 비교한 결과 표준편차는 $0.05{\sim}0.121$, COV는 $0.04{\sim}0.05$의 값을 보여 대체적으로 유사한 결과를 보였으며, 현장시험은 약 2.5%의 오차를 보여 측정값에 근접함을 알 수 있었다. 그 결과 제안된 지지력 산정법은 테이퍼말뚝의 지지력을 비교적 정확하게 예측하는 것으로 나타났다.

자기 유변 유체와 영구 자석을 이용한 회전 엑츄에이터의 개발 (MR rotary brake development with permanent magnet)

  • 권순우;박영진
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.183-186
    • /
    • 1997
  • This paper presents the new MR rotary brake with a permanent magnet, based on the shear operating mode. Due to the permanent magnet, the MR rotary brake can give the nominal resistance to the external disturbance and give the fail safe capacity to the system even when the power supply is accidentally cut off. As we apply the positive or negative current to the electric magnet coil, the resistance torque of the MR rotary brake can be reduced to the value less than the nominal resistance or increased up to the magnetic saturation point.

  • PDF

용접구조용 강재 적용 대형 보부재의 내화성능 연구 (Study of Fire Resistance for Long Span Beams Made of Submarine Structural Steels)

  • 권인규
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 추계 학술논문 발표대회
    • /
    • pp.149-150
    • /
    • 2015
  • Structural beam plays a key role to carry the applied load on the floors. And then the beam have to sustain the applied load and its load-bearing capacity in fire situation. In this study to know the fire resistance performance of long span beam made of a submarine structural steels, an engineering method is used using mechanical and thermal properties of structural steel at high temperature.

  • PDF

말뚝기초의 국제적 설계기준에 관한 고찰 (Study on International Code of Practice for Pile Foundation)

  • 윤길림;권오순;차재선
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 말뚝기초위원회 워크샵
    • /
    • pp.35-52
    • /
    • 1999
  • This paper addresses on new codes of practice, limit state design; load resistance factored design and Eurocode 7, which have recently been adopted by foundation engineers in North America and European Communities. A brief description of the limit state design concepts and some introductions to Australia and Sweden national code for pile foundation are made on behalf of pile capacity determination. Also, simple closed form solution for rational resistance factor when resistance is log-normally distributed, has been derived for pile foundation.

  • PDF

선형열원법에 의한 지중유효열전도도와 보어홀 전열저항 해석 (Analysis of Effective Soil Thermal Conductivities and Borehole Thermal Resistances with a Line Source Method)

  • 이세균;우정선;노정근
    • 한국태양에너지학회 논문집
    • /
    • 제30권4호
    • /
    • pp.71-78
    • /
    • 2010
  • Investigation of the effective soil thermal conductivity(k) is the first step in designing the ground loop heat exchanger(borehole) of a geothermal heat pump system. The line source method is required by New and Renewable Energy Center of Korea Energy Management Corporation in analyzing data obtained from thermal response tests. Another important factor in designing the ground loop heat exchanger is the borehole thermal resistance($R_b$). There are two methods to evaluate $R_b$ : one is to use a line source method, and the other is to use a shape factor of the borehole. In this study, we demonstrated that the line source method produces better results than the shape factor method in evaluating $R_b$. This is because the borehole thermal resistance evaluated with the line source method characteristically reduces the temperature differences between an actual and a theoretical thermal behaviors of the borehole. Evaluation of $R_b$ requires soil volumetric heat capacity. However, the effect of the soil volumetric heat capacity on the borehole thermal resistance is very small. Therefore, it is possible to use a generally accepted average value of soil volumetric heat capacity($=2MJ/m^3{\cdot}K$) in the analysis. In this work, it is also shown that an acceptable range of the initial ignoring time should be in the range of 8~16hrs. Thus, a mean value of 12 hrs is recommended.

Experiments and theory for progressive collapse resistance of ECC-concrete composite beam-column substructures

  • Weihong Qin;Wang Song;Peng Feng;Zhuo Xi;Tongqing Zhang
    • Structural Engineering and Mechanics
    • /
    • 제85권1호
    • /
    • pp.65-80
    • /
    • 2023
  • To explore the effect of Engineered Cementitious Composite (ECC) on improving the progressive collapse resistance of reinforced concrete frames under a middle column removal scenario, six beam-column substructures were tested by quasistatic vertical loading. Among the six specimens, four were ECC-concrete composite specimens consisting of different depth of ECC at the bottom or top of the beam and concrete in the rest of the beam, while the other two are ordinary reinforced concrete specimens with different concrete strength grades for comparison. The experimental results demonstrated that ECC-concrete composite specimens can improve the bearing capacity of a beam-column substructure at the stages of compressive arch action (CAA) and catenary action in comparison with ordinary concrete specimen. Under the same depth of ECC, the progressive collapse resistance of a specimen with ECC at the beam bottom was superior to that at the beam top. With the increase of the proportion of ECC arranged at the beam bottom, the bearing capacity of a composite substructure was increased, but the increase rate slows down with the proportion. Meanwhile, the nonlinear numerical analysis software MSC Marc was used to simulate the whole loading process of the six specimens. Theoretical formulas to calculate the capacities of ECC-concrete composite specimens at the stages of flexural action, CAA and catenary action are proposed. Based on the research results, this study suggests that ECC should be laid out at the beam bottom and the layout depth should be within 25% of the total beam depth.