• 제목/요약/키워드: resin acid

검색결과 774건 처리시간 0.022초

Mechanical Properties of Unidirectional Carbon-carbon Composites as a Function of Fiber Volume Content

  • Dhakate, S.R.;Mathur, R.B.;Dham, T.L.
    • Carbon letters
    • /
    • 제3권3호
    • /
    • pp.127-132
    • /
    • 2002
  • Unidirectional polymer composites were prepared using high-strength carbon fibers as reinforcement and phenolic resin as matrix precursor with keeping fiber volume fraction at 30, 40, 50 and 60% respectively. These composites were carbonized at $1000^{\circ}C$ and graphitised at $2600^{\circ}C$ in the inert atmosphere. The carbonized and graphitised composites were characterized for mechanical properties as well as microstructure. Microscopic studies were carried out of the polished surface of carbonized and graphitised composites after etching by chromic acid, to understand the effect of fiber volume fraction on oxidation at fiber-matrix interface. It is found that the flexural strength in polymer composites increases with fiber volume fraction and so does for the carbonised composites. However, the trend was found to be reversed in graphitised composites. In all the carbonized composites anisotropic region has been observed at fiber-matrix interface which transforms into columnar type microstructure upon graphitisation. The extension of strong and weak columnar type microstructure is function of fiber volume fraction. SEM microscopy of the etched surface of the sample reveal that composites containing 40% fiber volume has minimum oxidation at the interface, revealing a strong interfacial bonding.

  • PDF

Primer Bonding agent, 복합레진 내의 볼소의 법랑질에 대한 항우식 작용 (THE ANTICARIOGENIC EFFECT OF F IN PRIMER, BONDING AGENT AND COMPOSITE RESIN IN THE CAVOSURFACE ENAMEDL AREA)

  • 박성호
    • Restorative Dentistry and Endodontics
    • /
    • 제21권2호
    • /
    • pp.635-641
    • /
    • 1996
  • This study was designed to evaluate the anti cariogenic effect of F in primers, bonding agents, composite resins or glass ionomer cements in enamel. Twenty-five extracted teeth were selected and a cavity was prepared on either the buccal or the lingual surface of each tooth. After pumicing and etching, the samples were divided into 5 groups. In group A, the samples were primed, bonded and filled with ART bond and Brilliant Enamel (Coltene, Switzerland). Group B composed of Optibond and Herculited XRV (Kerr, USA), group C composed of Syntac and Tetric(Vivadent, Lichtenstein), and group D composed of Scotch-bond Multipurpose and Z 100 (3M, YSA). In group E, the samples were filled with glass ionomer cement (Fuji II LC, Japan), All surfaces except the 2mm beyond the cavosurface margin of the sample were protected, and samples were then put into an acid buffer for 3 days to develop the initial caries. The samples were then sectioned through the filling body into thin wafers and then examined with a polarizing microscope under water imbibition. The fluoride in primer, bonding agent, or composite filling material did not prevent the initial caries in the enamel area adjacent to the filling body whereas the fluoride in the glass ionomer did prevent the initial stage caries.

  • PDF

FDM 3D Printing 적층조건에 따른 기계적 물성의 연구 (A study of mechanical properties with FDM 3D printing layer conditions)

  • 김범준;이태흥;손일선
    • Design & Manufacturing
    • /
    • 제12권3호
    • /
    • pp.19-24
    • /
    • 2018
  • Fused deposition Modeling (FDM) is one of the most widely used for the prototype of parts at ease. The FDM 3D printing method is a lamination manufacturing method that the resin is melted at a high temperature and piled up one by one. Another term is also referred to as FFF (Fused Filament Fabrication). 3D printing technology is mainly used only in the area of prototype production, not in production of commercial products. Therefore, if FDM 3D printer is applied to the product process of commercial products when considered, the strength and dimensional accuracy of the manufactured product is expected to be important. In this study, the mechanical properties of parts made by 3D printing with FDM method were investigated. The aim of this work is to examine how the mechanical properties of the FDM parts, by changing of processing FDM printing direction and the height of stacking layer is affected. The effect of the lamination direction and the height of the stacking layer, which are set as variables in the lamination process, by using the tensile specimen and impact specimen after the FDM manufacturing process were investigated and analyzed. The PLA (Poly Lactic Acid) was used as the filament materials for the 3D printing.

Simultaneous Liquid Chromatography Tandem Mass Spectrometric Determination of 35 Prohibited Substances in Equine Plasma for Doping Control

  • Kwak, Young Beom;Yu, Jundong;Yoo, Hye Hyun
    • Mass Spectrometry Letters
    • /
    • 제13권4호
    • /
    • pp.158-165
    • /
    • 2022
  • Many therapeutic class drugs such as beta-blocker, corticosteroids, NSAIDs, etc are prohibited substances in the horse racing industry. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) technology makes it possible to isolate drugs from interference, enables various drug analyses in complex biological samples due to its sensitive sensitivity, and has been successfully applied to doping control. In this paper, we describe a rapid and sensitive method based on solid-phase extraction (SPE) using solid phase cartridge and LC-MS/MS to screen for different class's 35 drug targets in equine plasma. Plasma samples were pretreated by SPE with the NEXUS cartridge consisted non-polar carbon resin and minimum buffer solvent. Chromatographic separation of the analytes was performed on ACQUITY HSS C18 column (2.1 × 150 mm, 1.8 ㎛). The elution gradient was conducted with 5 mM ammonium formate (pH 3.0) in distilled water and 0.1% formic acid in acetonitrile at a flow rate of 0.25 mL/min. The selected reaction monitoring (SRM) mode was used for drug screening with multiple transitions in the positive ionization mode. The specificity, limit of detection, recovery, and stability was evaluated for validation. The method was found to be sensitive and reproducible for drug screening. The method was applied to plasma sample analysis for the proficiency test from the Association of Racing Chemist.

Separation and Purification of Antioxidant Peptide from Fermented Whey Protein by Lactobacillus rhamnosus B2-1

  • Hao Guo;Lei Fan;Lin Ding;Wenqin Yang;Chuangang Zang;Hong Guan
    • 한국축산식품학회지
    • /
    • 제43권1호
    • /
    • pp.10-24
    • /
    • 2023
  • In this study, a antioxidant activity peptide fraction was separated and purified from metabolites of whey protein fermented by Lactobacillus rhamnosus B2-1. The fermentation sample was separated by macroporous resin D101 and Sephadex G-15. The collected fractions were tested for antioxidant and antitumor activities. In order to test the antioxidant activity of fractions, Hydroxyl (·OH), 2,2'-azino-bis (3-ethylbenzothiazoline-6-sulfonic acid (ABTS), and Oxygen Radical Absorbance Capacity (ORAC) were used. The final purified peptide B11 showed highest ABTS and ·OH radical scavenging rate by 84.36±1.89% and 62.43±2.64%, respectively, and had an ORAC activity of 1,726.44±2.76 μM Trolox equivalent/g. Further, the inhibitory effect of B11 on the proliferation of LoVo human colon cancer cells, KB and Cal-27 human oral cancer cells were enhanced with increasing concentrations of B11. B11 contains 51.421% amino acids, with Glu and Asp being the major constituents. In this study, we obtained peptide fraction B11 with antioxidant activity, which is promising for development.

Real-time identification of the separated lanthanides by ion-exchange chromatography for no-carrier-added Ho-166 production

  • Aran Kim;Kanghyuk Choi
    • 대한방사성의약품학회지
    • /
    • 제7권2호
    • /
    • pp.69-77
    • /
    • 2021
  • No-carrier-added holmium-166 (n.c.a 166Ho) separation is performed based on the results of separation conditions using stable isotopes dysprosium (Dy) and holmium (Ho) to minimize radioactive waste from separation optimization procedures. Successful separation of two adjacent lanthanides was achieved by cation-exchange chromatography using a sulfonated resin in the H+ form (BP-800) and α-hydroxyisobutyric acid (α-HIBA) as eluent. For the identification process after separation of stable isotopes, the use of chromogenic reagents alternatively enables on-line detection because the lanthanides are hardly absorb light in the UV-vis region or exhibit radioactivity. Four different chromogenic reagents were pre-tested to evaluate suitable coloring reagents, of which 4-(2-Pyridylazo)resorcinol is the most recommendable considering the sensitivity and specificity for lanthanides. Lanthanide radioisotopes (RI) were monitored for separation with an RI detector using a lab-made separation LC system. Under the proper separation conditions, the n.c.a 166Ho was effectively obtained from a large amount of 100 mg dysprosium target within 2 hrs.

Effect of adhesive application method on repair bond strength of composite

  • Hee Kyeong Oh;Dong Hoon Shin
    • Restorative Dentistry and Endodontics
    • /
    • 제46권3호
    • /
    • pp.32.1-32.10
    • /
    • 2021
  • Objectives: This study aimed to evaluate the effect of the application method of universal adhesives on the shear bond strength (SBS) of repaired composites, applied with different thicknesses. Materials and Methods: The 84 specimens (Filtek Z350 XT) were prepared, stored in distilled water for a week and thermocycled (5,000 cycles, 5℃ to 55℃). They were roughened using 400-grit sandpapers and etched with phosphoric acid. Then, specimens were equally divided into 2 groups; Single Bond Universal (SU) and Prime&Bond Universal (PB). Each group was subdivided into 3 subgroups according to application methods (n = 14); UC: 1 coat + uncuring, 1C: 1 coat + curing, 3C: 3 coats + curing. After storage of the repaired composite for 24 hours, specimens were subjected to the SBS test and the data were statistically analyzed by 2-way analysis of variance and independent t-tests. Specimens were examined with a stereomicroscope to analyze fracture mode and a scanning electron microscope to observe the interface. Results: Adhesive material was a significant factor (p = 0.001). Bond strengths with SU were higher than PB. The highest strength was obtained from the 1C group with SU. Bonding in multiple layers increased adhesive thicknesses, but there was no significant difference in SBS values (p = 0.255). Failure mode was predominantly cohesive in old composites. Conclusions: The application of an adequate bonding system plays an important role in repairing composite resin. SU showed higher SBS than PB and the additional layers increased the adhesive thickness without affecting SBS.

미·이용업 폐기물 인모의 목재접착제 원료화 가능성 탐색 (Investigating The Potential of Human Hair Produced from The Beauty Parlor and Barbershop as a Raw Material of Wood Adhesives)

  • 양인;안세희
    • Journal of the Korean Wood Science and Technology
    • /
    • 제45권5호
    • /
    • pp.599-612
    • /
    • 2017
  • 본 연구는 미 이용원에서 폐기물로 발생되는 인모(人毛)의 NaOH 가수분해물, 도계 폐기물인 닭피의 $H_2SO_4$ 가수분해물 그리고 phenol-formaldehyde prepolymer (PF)를 가교제로 혼합하여 접착제를 조제하고, 이에 대한 물성 및 열수불용해율 측정결과를 통하여 인모의 목질판상재용 접착제의 원료화 가능성을 확인하기 위하여 수행하였다. 인모는 80% 이상의 케라틴계 단백질로 구성되어 있으며, 회분 함유량이 0.1% 미만으로 매우 낮았다. 인모에 함유된 단백질의 아미노산 가운데 glutamic acid의 함량이 가장 높았으며, 다음으로 cysteine, serine, arginine, threonine 순으로 조사되었다. 인모를 이용하여 조제한 접착제의 고형분 함량은 인모의 가수분해 조건 및 PF의 종류에 따라 33 - 41%의 범위였으며, 점도는 상온에서 $300-600mPa{\cdot}s$로 분사형 접착제로서 사용이 가능한 것으로 조사되었다. 접착제의 내수성을 비교하기 위하여 측정한 열수불용해율은 5% 농도의 NaOH 수용액에서 반응시킨 인모의 가수분해물, 고형분 함량을 기준으로 5 wt%의 $H_2SO_4$를 닭피에 첨가하여 반응시켜 준비한 가수분해물을 첨가하여 제조하고 경화시킨 접착제에서 높았다. 한편, PF에서 F/P의 몰비는 열수불용해율에 영향을 미치지 않았다. 이렇게 조제된 접착제의 열수불용해율을 현재 목질판상재 제조에 사용하고 있는 석유화학계 합성수지와 비교한 결과, 30 wt%의 PF로 조제한 인모 접착제는 전반적으로 요소 수지보다 낮은 것으로 조사되었다. 그러나 PF의 함량을 35 wt%까지 증가시켰을 때, 열수불용해율은 요소수지를 크게 상회하였으며, 멜리민-요소수지에 접근하는 것으로 조사되었다. 이와 같은 실험과 아울러 경제성을 분석한 결과, 적정조건에서 가수분해한 인모와 가교제로 35 wt%의 PF로 조제한 인모 접착제는 목질 판상재용 접착제로 적용이 가능할 것으로 판단된다.

가압경수로형 원전에서 발생된 폐수지의 $^{14}C$$^3H$ 동시 분리 및 측정 (Simultaneous Separation and Determination of $^{l4}C\;and\;^3H$ in Spent Resins from PWR Nuclear Power Plants)

  • 박순달;김정석;김종구;한선호;지광용
    • 방사성폐기물학회지
    • /
    • 제5권3호
    • /
    • pp.179-188
    • /
    • 2007
  • 가압경수로형 원자력발전소의 운영과정에서 발생된 폐수지내 $^{14}C$$^3H$의 분포특성을 조사하였다. $Na_2^{14}CO_3$ 표준용액을 사용한 $^{14}C$의 회수율 측정결과, 사용한 산의 종류에 관계없이, 3 N-HCl $3\;N-HNO_3,\;3\;N-H_2SO_4$, 주입한 $^{14}C$ 농도 $0.72\;Bq{\sim}460\;Bq$ 범위에서 $81%{\sim}100%$의 회수율을 나타내었다. 같은 장치를 사용하여 HTO 표준용액 증류에 의한 $^3H$의 회수율은 주입한 $^3H$ 농도 $0.60\;Bq{\sim}435\;Bq$ 범위에서 $81%{\sim}101%$ 이었다. 습식산화-산용출법에 의한 폐수지의 $^{14}C$$^3H$ 동시분리시, $3\;N-H_2SO_4$를 사용했을 때 다른 감마핵종에 의한 방해가 없었으며, $^3H$ 포집액이 섬광제와 잘 혼합되었다. 그러나 3 N-HCl을 사용했을 때 $^3H$ 포집용액에서 $^{60}Co,\;^{134}Cs,\;^{137}Cs$$^{54}Mn$ 등의 감마핵종이 검출되었다. 또한 Sample Oxidizer에 의한 $^3H$ 포집용액에서도 $^{60}Co,\;^{134}Cs,\;^{137}Cs$$^{54}Mn$ 등이 검출되었으며, $^{14}C$ 포집용액에서는 $^{134}Cs,\;^{137}Cs$이 검출되었다. 폐수지의 총 $^{14}C$ 함량중 약 70% 이상이 무기 탄소로 확인되었다. 30개 폐수지 시료중 8개 고방사능 폐수지의 $^{14}C$$^3H$의 평균농도는 각각 $19000\;Bq/g{\pm}41000\;Bq/g,\;670\;Bq/g{\pm}460\;Bq/g$이었으며 22개 저방사능폐수지에서는 각각 $4.2\;Bq/g{\pm}4.3\;Bq/g,\;6.0\;Bq/g{\pm}5.3\;Bq/g$이 검출되었다. 고방사능 폐수지의 평균 $^{14}C/^3H$비는 28로 저방사능 폐수지의 0.70에 비해 높게 나타났으며, $^{14}C$$^3H$의 농도는 서로 비례하는 경향을 보였다.

  • PDF

Silane의 처리시기와 타액오염이 도재-레진 시멘트의 전단 결합강도에 미치는 영향 (The effect of silane treatment timing and saliva contamination on shear bond strength of resin cement to porcelain)

  • 노영선;류재준;서규원
    • 대한치과보철학회지
    • /
    • 제47권1호
    • /
    • pp.61-69
    • /
    • 2009
  • 서론: 인접 자연치와 아름답고 자연스런 조화를 이루는 심미적 치료를 위해 도재 수복물은 대중적인 치료방법의 하나로 잡고 있다. 임상에서 도재 수복물이 제작 후 치아에 시멘트로 접착을 하기 전 먼저 구강 내에서 시적할 때 수복물 표면에 타액, 혈액, 시적용 시멘트 등으로 인해 오염될 수 있다. 연구 목적: 이 연구의 목적은 도재 수복물로 사용되고 있는 라미네이트 도재에 실란 결합제의 처리 시기를 달리할 때와 도재 수복물을 치아에 시적 할 때 타액의 오염여부가 실란 결합제의 물리적, 화학적 반응성에 미치는 영향을 관찰하여 도재와 레진 시멘트 사이의 결합력의 안정성을 평가하는 것이다. 연구 재료 및 방법: 라미네이트용 도재를 360개의 원반모형과 5개의 정사각형 모형으로 제작하여 20군으로 나눈다. 각 군에 표면처리를 달리 한 뒤 푸리에 적외선 분광계, 접촉각 측정기와 인스트론 만능 시험기를 이용해 화학적, 물리적 비교를 하였다. 통계는 각 군의 전단 결합 강도의 유의성을 검증하기 위하여 일원분산분석(ANOVA) 후 사후검정은 던넷 다중비교 (Dunnett's multiple comparison)를 시행하였다 (P > .05). 연구 결과: 푸리에 적외선 분광 자료에 의해 본 타액 오염 및 실란의 처리 시기에 따른 화학적 변화는 크지 않았다. 접촉각은 타액 오염 후 낮아졌으나 인산으로 산 부식 후 각도가 증가하였다. 전단 결합강도값은 열 순환후의 군에서 미리 실란으로 보호한 경우에 유의한 차이가 있었다. 결론: 수복물의 내구성에 영향을 미치는 다양한 구강환경과 유사한 조건에서 수복물의 물성평가를 같이 고려해 볼 때 실란 결합제를 이용한 수복물의 접착시 실란 결합제를 수복물에 미리 도포하여 일정시간의 경과 후 수복물을 접착하며, 타액 오염이 발생할 경우 인산으로 수복물을 세척하는 것이 유용한 방법 임을 알 수 있었다