• Title/Summary/Keyword: residual view

Search Result 154, Processing Time 0.029 seconds

Efficient De-quantization Method based on Quantized Coefficients Distribution for Multi-view Video Coding (다시점 영상 부호화 효율 향상을 위한 양자화 계수 분포 기반의 효율적 역양자화 기법)

  • Park, Seung-Wook;Jeon, Byeong-Moon
    • Journal of Broadcast Engineering
    • /
    • v.11 no.4 s.33
    • /
    • pp.386-395
    • /
    • 2006
  • Multi-view video coding technology demands the very high efficient coding technologies, because it has to encode a number of video sequences which are achieved from a number of video cameras. For this purpose, multi-view video coding introduces the inter-view prediction scheme between different views, but it shows a limitation of coding performance enhancement by adopting only new prediction method. Accordingly, we are going to achieve the more coding performance by enhancing dequantizer perfermance. Multi-view video coding is implemented basically based on H.264/AVC and uses the same quantization/de-quantization method as H.264/AVC does. The conventional quantizer and dequantizer is designed with the assumption that input residual signal follows the Laplacian PDF. However, it doesn't follow the fixed PDF type always. This mismatch between assumption and real data causes degradation of coding performance. To solve this problem, we propose the efficient de-quantization method based on quantized coefficients distribution at decoder without extra information. The extensive simulation results show that the proposed algorithm produces maximum $1.5\;dB{\sim}0.6\;dB$ at high bitrate compared with that of conventional method.

A numerical study on the suction performance of a submerged cargo pump (수중 카고 펌프의 흡입성능에 관한 수치해석적 연구)

  • Kim, Joon-Hyung;Choi, Young-Seok;Lee, Kyoung-Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.11 no.6
    • /
    • pp.18-23
    • /
    • 2008
  • In this paper, effects of inlet shape on the performance of a submerged cargo pump were numerically studied using a commercial CFD code ANSYS-CFX. The inlet shape, especially the gap between pump and suction well, is an important parameter in a point of view of performances of submerged cargo pump due to its effects on the residual and also hydraulic performance of the pump, respectively. To investigate the optimized gap, the overall performance degradations were calculated with the gap. In addition to that, the flow field through the gap was investigated to explain the effect of velocity non-uniformity on the performance of the pump impeller.

A cross - sectional analysis of scientific and technological performance for the railroad R&D (철도 R&D의 과학기술적 성과에 대한 횡단면 분석)

  • Park, Man-Soo;Bang, Yoon-Seok;Kwon, Yong-Jang;Moon, Dae-Seop;Lee, Hi-Sung
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.1582-1590
    • /
    • 2011
  • An analysis of the railroad industry for R&D investments has been insufficient whereas there are lots of analysis of accumulation of technology, economic performances and ripple effects for macroscopic view and other industry of R&D investments. This study decided intellectual rights, patent, and paper as common indicators of scientific and technological performances for setting up performance targets through surveying and analysis of preceding study and verified a appropriateness of scientific and technological performances for railroad R&D 11 projects which were successfully finished. Preceding study has been set up performance targets by research investments as input, but this study made a performance target by model through a cross-sectional and residual analysis of performances of railroad R&D 11 Projects in applying research investments, capital investments, inner labor cost and inner labor cost per man and research time as inputs, and verified a validity and a empirical analysis through analysis of other project.

  • PDF

Fire Resistance Test of Steel Fiber Reinforced Concrete (강섬유보강콘크리트의 내화성에 관한일실험)

  • 윤재환
    • Fire Science and Engineering
    • /
    • v.1 no.1
    • /
    • pp.19-26
    • /
    • 1987
  • In this study, fire resistance of steel fiber reinforced concrete was investigated Cylindrical and prismatic specimens made of Ordinary Portland Cement plain concrete and steel fiber reinforced concrete were exposed to heating in accordance with a standard time-temperature curve as specified in KS·F22 57, method of fire resistance test for structural parts of buildings, the period of heating was 1 hour and 2 hours. After the fire resistance test, mechanical properties of specimens such as compressive and bending strength, stress-strain curve, static and dynamic modulus of elasticity and bending toughness were investigated. Also the cracks and spallings of the specimens were observed. From the test results, it was confirmed that steel fiber reinforced concrete has a excellent fire resistance than plain concrete in the view of higher residual strength of concrete and smaller crackings because of steel fibers in concrete.

  • PDF

The Proportional Likelihood Ratio Order for Lindley Distribution

  • Jarrahiferiz, J.;Mohtashami Borzadaran, G.R.;Rezaei Roknabadi, A.H.
    • Communications for Statistical Applications and Methods
    • /
    • v.18 no.4
    • /
    • pp.485-493
    • /
    • 2011
  • The proportional likelihood ratio order is an extension of the likelihood ratio order for the non-negative absolutely continuous random variables. In addition, the Lindley distribution has been over looked as a mixture of two exponential distributions due to the popularity of the exponential distribution. In this paper, we first recalled the above concepts and then obtained various properties of the Lindley distribution due to the proportional likelihood ratio order. These results are more general than the likelihood ratio ordering aspects related to this distribution. Finally, we discussed the proportional likelihood ratio ordering in view of the weighted version of the Lindley distribution.

Thick Copper Substrate Fabrication by Air-Cooled Lapping and Post Polishing Process (공기 냉각 방식의 래핑을 이용한 구리 기판 연마 공정 개발)

  • Lee, Ho-Cheol;Kim, Dong-Jun;Lee, Hyun-Il
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.19 no.5
    • /
    • pp.616-621
    • /
    • 2010
  • New type of the base material of the light-emitting diode requires copper wafer in view of heat and electrical conductance. Therefore, polishing process of the substrate level is needed to get a nanometer level of surface roughness as compared with pattern structure of nano-size in the semiconductor industry. In this paper, a series of lapping and polishing technique is shown for the rough and deflected copper substrate of thickness 3mm. Lapping by sand papers tried air cooling method. And two steps of polishing used the diamond abrasives and the $Al_2O_3$ slurry of size 100mm considering the residual scratch. White-light interferometer proved successfully a mirror-like surface roughness of Ra 6nm on the area of $0.56mm{\times}0.42mm$.

INVESTIGATIONS ON VARIABLE WELD PENETRATIONS IN GTA WELDING OF AUSTENITIC AND MARTENSITIC STAINLESS STEELS

  • Puybouffat, Sylvain;Chabenat, Alain;Boudot, Cecile;Marya, Surendar
    • Proceedings of the KWS Conference
    • /
    • 2002.10a
    • /
    • pp.752-756
    • /
    • 2002
  • Variable weld bead penetrations related to the base metal chemistry of stainless steels in GTA welding have been under constant investigations due to their industrial implications. It has been proposed that among other elements, the sulfur content of steels determines the weld pool geometry, particularly its penetration. It is suggested that the surface tension temperature gradient of steels becomes positive with appropriate dosing in sulfur and results in inward melt flow, propitious for deeper welds. However, the chemistry of industrial steels is complex due to the presence of multiple minor elements either deliberately added or remnant impurity traces. With this in view, investigations on 41 austenitic and nine martensitic stainless steels were carried to see if there existed any possible relation between the weld profile and some of the designated elements. The results suggest no direct correlation between sulfur or any other major or trace element and weld penetration. At first glance the results are contradictory to what is often asserted.

  • PDF

An Experimental Study on Allowable Size of Incomplete Penetration in Butt Joint Bridge Weld Considering Fatigue Strength (교량의 피로강도를 고려한 맞대기용접부 불안전용입 한계결함 결정에 관한 연구)

  • 백영남;장영권
    • Journal of Welding and Joining
    • /
    • v.18 no.3
    • /
    • pp.68-75
    • /
    • 2000
  • The incomplete penetration(IP) discontinuity in butt joint weld, which is detected during safety analysis of the steel bridge by nondestructive evaluation(NDE) method, is classified as unacceptable defect according to the NDE codes and standards. In fact, there are a little allowance in butt joint weld in the view point of design criterion, and also detected IP discontinuity should be classified and evaluated for the fatigue strength and residual life estimation. In this study, we performed fatigue test to evaluate the fatigue strength of high strength steel(SWS490A) containing IP discontinuities in various size, the results compared and classified according to the bridge construction standard specification which published by korea administration of construction and traffic. Experimental results could be used to evaluate and estimate the IP discontinuities considering different stress range in butt joint bridge weld during periodic safety inspection.

  • PDF

Multi-view residual image coding technique using adaptive quantization and scanning method (적응적 양자화 및 스캔 방법을 이용한 다시점 차영상 부호화에 관한 연구)

  • 임정은;손광훈
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.3A
    • /
    • pp.249-257
    • /
    • 2002
  • 본 논문에서는 스테레오/다시점 영상을 효율적으로 압축할 수 있는 차 영상 부호화 방법을 제안한다. 예측된 영상과 원 영상의 차이 정보를 보다 효율적으로 전송하기 위하여 DCT를 기반으로 차 영상 부호화를 하게 되는데 DCT 계수들의 방향성을 이용하여 양자화 및 스캔 방법을 각 블록의 특성에 따라 다르게 적용하였다. 특히 다시점 영상의 부호화는 첫 번째 시점 영상을 기준 영상으로 정하여 나머지 시점 영상을 기준 영상으로부터 변이를 추정하여 복원하는 방식과 다시점 영상 중 가려진 영역의 비율을 고려하여 가려진 영역이 상대적으로 제일 적은 영상을 기준 영상으로 설정하여 나머지 영상을 변이 추정하여 복원하는 방법으로 나누어 실험하였다. 실험 결과 모든 압축률에 대하여 제안 방식이 기존의 차 영상 부호화 방법보다 우수함을 확인하였고, 가려진 영역의 상대적인 비율을 고려하여 다시점 영상을 부호화한 제안 방식이 기존의 방식 및 첫 번째 시점을 기준 영상으로 설정하여 부호화한 제안 방식보다 우수함을 확인하였다.

Analytics of PIV Measurement and Its Application for Higher Performances

  • NISHIO Shigeru;SUGII Yasuhiko
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2001.12a
    • /
    • pp.62-74
    • /
    • 2001
  • Present paper describes the principles of PIV measurement approaching from the analytical view, which enables to explain the general form of principles covering all the PIV measurement, and that gives theoretical basis for its higher measurement performances. The explanation of the measurement principles started from the definition of governing equation in differential form as same as the gradient method, and the integral along the particle path line was executed to show the principle of the correlation method with same basis. The integral processes clearly shows the analytical reason why the correlation peak gives the terminal point of path line, and how the effects of deformation and rotation of fluid appears in the correlation map. These results have no differences from our experiences and understandings of the conventional PIV measurement definition in final form. However, the analytical approach enable to understand those facts a priori, and it makes easy to achieve the innovative higher performances of measurement. Analytical explanation clearly shows the behavior of the residual errors caused by the fluid motion, and it enables to analyze the measurement uncertainty theoretically.

  • PDF