• Title/Summary/Keyword: residual time

Search Result 2,097, Processing Time 0.031 seconds

Distributions of Local Supply and Exhaust Effectiveness according to Room Airflow Patterns

  • Han, Hwa-Taik;Choi, Sun-Ho;Lee, Woo-Won
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.10 no.4
    • /
    • pp.177-183
    • /
    • 2002
  • A pulsed tracer gas technique is applied to measure the distributions of local mean age and local mean residual-life-time of air in a half-scale experimental chamber, The airflow patterns in the chamber are visualized by a Helium bubble generator for three different exhaust locations. A supply slot is located at the top of a right wall, and an exhaust slot is at either bottom-left (Case 1), bottom-right (Case 2), or top-left (Case 3) location. Results show that the distributions of local mean age and local mean residual-life-time are different from each other, but both of them are closely related to the airflow pattern in the space. Included are discussions on explaining the variations of overall room ventilation effectiveness depending upon airflow rates for three different supply-exhaust configurations.

Detecting Anomalies in Time-Series Data using Unsupervised Learning and Analysis on Infrequent Signatures

  • Bian, Xingchao
    • Journal of IKEEE
    • /
    • v.24 no.4
    • /
    • pp.1011-1016
    • /
    • 2020
  • We propose a framework called Stacked Gated Recurrent Unit - Infrequent Residual Analysis (SG-IRA) that detects anomalies in time-series data that can be trained on streams of raw sensor data without any pre-labeled dataset. To enable such unsupervised learning, SG-IRA includes an estimation model that uses a stacked Gated Recurrent Unit (GRU) structure and an analysis method that detects anomalies based on the difference between the estimated value and the actual measurement (residual). SG-IRA's residual analysis method dynamically adapts the detection threshold from the population using frequency analysis, unlike the baseline model that relies on a constant threshold. In this paper, SG-IRA is evaluated using the industrial control systems (ICS) datasets. SG-IRA improves the detection performance (F1 score) by 5.9% compared to the baseline model.

Residual strength of spalled high-performance concrete members subjected to fire (화재시 고강도 콘크리트 부재의 폭렬성상에 따른 잔존강도)

  • Choi, Eun-Gyu;Shin, Yeong-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.941-944
    • /
    • 2008
  • This study is aimed to investigate the residual strength of fire damaged high-performance concrete flexural and compressive members. The compressive strength of specimens is 55MPa and the main parameter for comparison is the exposure time to fire. In case of beams, the cover thickness made the differences in spalled section area, residual strength and serviceability. The exposure time to fire did not affect on the spalled section area in case of compressive members without loading. However, the residual strength and stiffness was reduced by the time exposed to fire. This study can be used to estimate the performance of fire damaged high-strength concrete structural members for reusing and to give the information for repairing and strengthening.

  • PDF

The Determination of TRC using an Electrochemical Method (II: Pt electrode) (전기화학적 방법의 TRC(Total residual chlorine) 측정 연구(II: Pt전극 이용))

  • Lee, JunCheol;Pak, DaeWon
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.3
    • /
    • pp.304-310
    • /
    • 2014
  • The conventional methods for total residual chlorine such as iodometry and DPD colorimetric can cause secondary pollution due to additional agents, also have a wide error range. As for alternative, electrochemical method can measure TRC(Total residual chlorine), and is not required as additional agents, also very suitable for using the fields of ballast water because test time is relatively fast. Therefore, this study was investigated for changing charge by agitation, salt concentration, and temperature change. Charge showed differences based on changes of reduction peak with or without agitation. In contrast, TRC and charge were well correlated in constant agitation speed. As TRC and charge were analyzed with high correlations in constant salinity and temperature of ocean, thereby conductivity was firstly measured, and charge had high correlation for TRC in spite of changing salinity and temperature Pt electrode revealed high reliability ($r^2=0.960$) because it was rarely effected by TRC, On the other hand, Au electrode appeared inadequate ($r^2=0.767$) to use sensor in less than 1.0 ppm of TRC. For high accuracy and detection of TRC, Pt and Au electrodes for test time were, respectively, 14 and 22 seconds. As a result, Pt electrode was more valuable than Au electrode in terms of response time.

Simulation for Chlorine Residuals and Effect of Rechlorination in Drinking Water Distribution Systems of Suwon City (수원시 상수관망에서 잔류염소와 재염소주입의 효과 예측)

  • Kim, Kyung-Rok;Lee, Byong-Hi;Yoo, Ho Sik
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.14 no.1
    • /
    • pp.108-116
    • /
    • 2000
  • Chlorine is widely used as a disinfectant in drinking-water systems throughout the world. Chlorine residual was used as an indicator for prediction of water quality in water distribution systems. The variation of chlorine residual in drinking water distribution systems of Suwon city was simulated using EPANET. EPANET is a computerized simulation model which predicts the dynamic hydraulic and water quality behavior within a water distribution system operating over an extended time period. Sampling and analysis were performed to calibrated the computer model in 1999 (Aug. Summer). Water quality variables used in simulations are temperature, roughness coefficient, pipe diameter, pipe length, water demand, velocity and so on. Extended water residence time affected water quality due to the extended reaction time in some areas. All area showed the higher concentration of chlorine residual than 0.2mg/l(standard). So it can be concluded that any area in Suwon city is not in biological regrowth problem. Rechlorination turned out to be an useful method for uniform concentration of free chlorine residual in distribution system. The cost of disinfectant could be saved remarkably by cutting down the initial chlorine concentration to the level which guarantees minimum concentration (0.2mg/l) throughout the distribution system.

  • PDF

Residual Polar Motion excluding Chandler and Annual components

  • Na, Sung-Ho;Baek, Jeong-Ho;Kwak, Young-Hee;Yoo, Sung-Moon;Cho, Jung-Ho;Cho, Sung-Ki;Park, Jong-Uk;Park, Pil-Ho
    • Bulletin of the Korean Space Science Society
    • /
    • 2011.04a
    • /
    • pp.22.1-22.1
    • /
    • 2011
  • Two dominant components of polar motion are the Chandler and the annual components. Recently, the existence of 500-day period component in the Earth's polar motion has been manifested. But its existence is not clear on Fourier spectrum. One cause of difficulty involved here is that the amplitudes of the two main components are slightly variable in time by certain amounts (Chandler: 0.15~0.28 arcsec, annual: 0.09~0.15 arcsec). A residual polar motion time series excluding the two main components for a time span between 1962 Jan and 2010 Nov from IERS C04 time series dataset was constructed by least square fitting. For faithful fitting, 43 time segments of 6.8 year length (each starts on January 1st of successive years) were separately acquired and later combined together. The period of dominant peak in the spectrum of this residual polar motion time series is 490 days. Next peaks have their periods as semi-annual, 300~330 days, ~560 days, 670 days, and 1360 days.

  • PDF

A Study on Welding Residual Stress Measurement by Laser Inteferometry and Spot Heating Method (레이저 간섭법과 점 가열법을 이용한 용접부의 잔류응력 측정에 관한 연구)

  • Hong, Kyung-Min;Lee, Dong-Hwan;Kang, Young-June
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.3
    • /
    • pp.101-108
    • /
    • 2008
  • Residual stress is one of the causes which make defects in engineering components and materials. Many methods have been developing to measure the residual stress. Though these methods provide the information of the residual stress, they also have disadvantage like a little damage, time consumption, etc. In this paper, we devised a new experimental technique to measure residual stress in materials with a combination of laser speckle pattern interferometry and spot heating. The speckle pattern interferometer measures in-plane deformation during the heat provides for much localized stress relief. 3-D shape is used for determining heat temperature and other parameters. The residual stresses are determined by the amount of strain that is measured subsequent to the heat and cool-down of the region being interrogated. A simple model is presented to provide a description of the method. In this paper, we could experimentally confirm that residual stress can be measured by using laser interferometry and spot heating method.

The Effects of the Drive-in Process Parameters on the Residual Stress Profile of the $p^+$ Silicon Thin Film (후확산 공정 조건이 $p^+$ 실리콘 박막의 잔류 응력 분포에 미치는 영향)

  • Jeong, Ok-Chan;Park, Tae-Gyu;Yang, Sang-Sik
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.9
    • /
    • pp.665-671
    • /
    • 1999
  • The paper represents the effects of the drive-in process parameters on the residual stress profile of the $p^+$ silicon film. Since the residual stress profile is notuniform along the direction normal to the surface, the residual stress is assumed to be a polynomial function of the depth. All the coefficients of the polynomial can be determined by measuring of the thicknesses and the deflections of cantilevers and the deflection of a rotating beam with a surface profiler meter and a microscope. As the drive-in temperature or the drive-in time increases, the boron concentration decreases and the magnitude of the average residual tensile stress decreases. Then, near the surface of the $p^+$ film the residual tensile stress is transformed into the residual compressive stress and its magnitude increases.

  • PDF

Residual Life Assessment on Cast Iron Pipes of Water Distribution System (상수도관로중 주철관종의 잔존수명 평가에 관한 연구)

  • Lee, Hyun-Dong;Bae, Chul-Ho;Hong, Seong-Ho;Hwang, Jae-Woon;Kwak, Phill-Jae
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.3
    • /
    • pp.206-214
    • /
    • 2004
  • Residual wall thicknesses, corrosion rates, and residual life of thirty four samples of cast iron pipes(CIPs) and ductile cast iron pipes(DCIPs) collected from water mains of B city were studied to estimate their remaining service life or optimum time of rehabilitation. The internal maximum corrosion depths of samples measured using a dial gauge after shot blasting were twice higher than the external in most cases. Therefore corrosion of water pipes was much more affected by internal water quality than soil. Residual wall thicknesses of DCIPs were higher than those of CIPs. That reason was thought to be that DCIPs have been protected from internal corrosion by lining cement mortar. Residual life calculated by maximum corrosion rate was ranged up to 44 years with 12.40 years average. Since most CIPs were much deteriorated, rehabilitation plan should be established soon in B city. Residual life of DCIP was 33.52 years average. When cement mortar lining is used up by neutralization of DCIPs. DCIP also should be rehabilitated.

Probability-based prediction of residual displacement for SDOF using nonlinear static analysis

  • Feng, Zhibin;Gong, Jinxin
    • Earthquakes and Structures
    • /
    • v.22 no.6
    • /
    • pp.571-584
    • /
    • 2022
  • The residual displacement ratio (RDRs) response spectra have been generally used as an important means to evaluate the post-earthquake repairability, and the ratios of residual to maximum inelastic displacement are considered to be more appropriate for development of the spectra. This methodology, however, assumes that the expected residual displacement can be computed as the product of the RDRs and maximum inelastic displacement, without considering the correlation between these two variables, which inevitably introduces potential systematic error. For providing an adequately accurate estimate of residual displacement, while accounting for the collapse resistance performance prior to the repairability evaluation, a probability-based procedure to estimate the residual displacement demands using the nonlinear static analysis (NSA) is developed for single-degree-of-freedom (SDOF) systems. To this end, the energy-based equivalent damping ratio used for NSA is revised to obtain the maximum displacement coincident with the nonlinear time history analysis (NTHA) results in the mean sense. Then, the possible systematic error resulted from RDRs spectra methodology is examined based on the NTHA results of SDOF systems. Finally, the statistical relation between the residual displacement and the NSA-based maximum displacement is established. The results indicate that the energy-based equivalent damping ratio will underestimate the damping for short period ranges, and overestimate the damping for longer period ranges. The RDRs spectra methodology generally leads to the results being non-conservative, depending on post-yield stiffness. The proposed approach emphasizes that the repairability evaluation should be based on the premise of no collapse, which matches with the current performance-based seismic assessment procedure.