• Title/Summary/Keyword: residual time

Search Result 2,097, Processing Time 0.037 seconds

Characterization Study of Crude Oil Degrading Microbiology Isolated from Incheon Bay (인천 연안에서 분리한 원유 분해 미생물의 특성 연구)

  • Choi, Hye Jin;Oh, Bo Young;Han, Young Sun;Hur, Myung Je;Kim, Jong-Guk
    • Journal of Life Science
    • /
    • v.24 no.6
    • /
    • pp.694-699
    • /
    • 2014
  • Indigenous microorganisms play decisive roles in biodegradation. In this study, eighty strains of hydrocarbon-degrading microbes were isolated from Incheon Bay. Among them, 12 strains were selected by an oil film collapsing method. The bacterial strain 'Incheon9' was eventually selected based on its relatively higher lipase and emulsification activities, and was identified as Acinetobacter sp. (NCBI accession code: KF54854). The optimum condition for the growth and emulsification activity of Acinetobacter sp. Incheon9 was $20^{\circ}C$, pH 7, and 1% NaCl. The optimum time for the best production of biosurfactant was 72 hrs. The oil degradation ability of Acinetobacter sp. Incheon9 was investigated by measuring the residual oils in the culture medium by gas chromatography (FID). This research provides foundational data for eco-friendly environmental remediation by microorganisms.

Probabilistic Stability Analysis of Unsaturated Soil Slope under Rainfall Infiltration (강우침투에 대한 불포화 토사사면의 확률론적 안정해석)

  • Cho, Sung-Eun
    • Journal of the Korean Geotechnical Society
    • /
    • v.34 no.5
    • /
    • pp.37-51
    • /
    • 2018
  • The slope failure due to the rainfall infiltration occurs frequently in Korea, since the depth of the weathered residual soil layer is shallow in mountainous region. Depth of the failure surface is shallow and tends to pass near the interface between impermeable bedrock and soil layer. Soil parameters that have a significant impact on the instability of unsaturated slopes due to rainfall infiltration inevitably include large uncertainties. Therefore, this study proposes a probabilistic analysis procedure by Monte Carlo Simulation which considers the hydraulic characteristics and strength characteristics of soil as random variables in order to predict slope failure due to rainfall infiltration. The Green-Ampt infiltration model was modified to reflect the boundary conditions on the slope surface according to the rainfall intensity and the boundary condition of the shallow impermeable bedrock was introduced to predict the stability of unsaturated soil slope with shallow bedrock under constant rainfall intensity. The results of infiltration analysis were used as inputs of infinite slope analysis to calculate the safety factor. The proposed analysis method can be used to calculate the time-dependent failure probability of soil slope due to rainfall infiltration.

Purification and Characterizationn of Biosurfactant from Marine Pseudomonas sp. CHCS-2 (해양으로부터 분리한 Pseudomonas sp. CHCS-2가 생산하는 Biosurfactant의 정제 및 특성에 관한 연구)

  • 류병호;김학주
    • KSBB Journal
    • /
    • v.10 no.5
    • /
    • pp.582-588
    • /
    • 1995
  • A marine microorganism producing biosurfactant was isolated from the oil polluted coast of Chung-Mu in Korea, and was identified as Pseudomonas sp.. It produced the biosurfactanl and its optimum culture conditions for pH and salt concentration were 8.0 and 3.0%, respectively. The productivity of biosurfactant from this strain was affected by the nitrogen source used. For the oil resolvability of the biosurfactant, the residual oil in the culture broth with 2% Kuwait crude oil at each time of 48, 96, and 132hr was investigated by gas chromatography. As result of this experiment, it was verified that the biosurfactant acted on C10-C14, of Kuwait crude oil and so the oil was decomposed. The biosurfactant isolated from the supernatant was purified by adsorption to Amberliter XAD-7 and followed by gel chromatography (Sephadex G-100) and HPLC. The purified biosurfactant showed a high value of emulsifying activity at $40^{\circ}C$ and the emulsifying stability was maintained at the temperature range of $30^{\circ}C$$60^{\circ}C$. The purified biosurfactant reduced the interfacial tension of Kuwait crude oil remarkably and showed improved dispersing ability compared to those of commercial surfactants such as Tween 80, Tween 60 and SDS.

  • PDF

Determination of Optimum Coagulant Dosage for Effective Water Treatement of Chyinyang Lake - The Effect of Coagulant Dosing on Removal of Algae- (진양호소수의 효과적인 정수처리를 위한 최적응집제 주입량 결정 -조류제거를 위한 응집제 주입효과-)

  • 이원규;조주식;이홍재;임영성;허종수
    • Journal of Environmental Science International
    • /
    • v.8 no.5
    • /
    • pp.625-631
    • /
    • 1999
  • This study was performed to determine the optimum coagulant dosing for effective treatment of raw water in Chinyang lake. Removal rates of algae and characteristics of the water according to coagulants dosage were investigated by treatment with Microcystis aeruginosa, which is a kind of blue-green algae, to the raw water below 5NTU. The coagulants dosage for maximum removal rate of algae were 30 mg/$\ell$ of Alum, 30 mg/$\ell$ of PAC and 10 mg/$\ell$ of PACS, respectively. The removal rate of algae in 30 mg/$\ell$ of PAC was highest as 85% compared with the other treatments. At the point of maximum removal rate of algae, the removal rates of turbidity were 34%, 66% and 22% in Alum, PAC and PACS, respectively. Residual Al was decreased depend upon decreasing turtidity in water by treatment of Alum or PAC, but decreased depend upon increasing turbidity in water by treatment of PACS. The removal rate of ${Mn}_{2+}$ in water was high in the order of Alum, PAC and PACS treatment. And ${Fe}_{2+}$ in water was not changed by treatemnt of these coagulants. Particle numbers distributions according to the particle size of suspended solids that were not precipitated at 8 min. of settling time after treatment of coagulants dosage for the maximum removal rate of algae were investigated. Most of the particle sizes were below 30 $\mu$m and particle numbers distributions below 10 $\mu$m were 64%, 56% and 66% by treatment of Alum, PAC and PACS, respectively. Zeta potential was in the range of -6.1~-9.7 mV at optimum coagulants dosage for algae removal.

  • PDF

Effect of Aqueous Chlorine Dioxide Treatment on the Decomposition of Pesticide Residues (이산화염소수 처리에 의한 잔류농약 분해 효과)

  • Kim, Kyu-Ri;Song, Kyung-Bin
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.38 no.5
    • /
    • pp.601-604
    • /
    • 2009
  • This study was conducted to examine the effect of aqueous chlorine dioxide treatment as a washing method on removal of pesticide residues. Three pesticides of chlorpyrifos, diazinon, and metalaxyl, which are commonly used in vegetable crops, were treated with 10, 50, and 100 ppm of aqueous chlorine dioxide and decomposition of the pesticides was determined using gas chromatography. Three pesticides used in this study were decomposed by aqueous chlorine dioxide treatment and removal rate was proportional to treatment time as well as concentration of aqueous chlorine dioxide. In particular, 100 ppm of aqueous chlorine dioxide treatment decreased the pesticides efficiently. In addition, lettuce was treated by dipping in distilled water and 100 ppm aqueous chlorine dioxide, respectively, and was compared regarding removal efficiency of the pesticides. The results revealed that washing with 100 ppm aqueous chlorine dioxide for 10 min was the most effective for removing the pesticides. These results suggest that aqueous chlorine dioxide can be used as a washing method of fresh produce to remove the residual of pesticides.

Multi-Modulus Blind Equalization Algorithm (다중 Modulus 블라인드 등화 알고리즘)

  • Choi, Ik-Hyun;Kim, Chul-Min;Oh, Kil-Nam;Choi, Soo-Chul
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.2
    • /
    • pp.465-468
    • /
    • 2005
  • MMA(Multi-Modulus Algorithm) is inferior at a initial equalization in high ISI(intersymbol interference), because it is the inaccurate decision. To improve this probel SMMA(Sliced Multi-Modulus Algorithm) is based on using the MCMA(Modified Constant Modulus Algorithm). SMMA is a improved capability than MMA in high SNR but is inaccurate decision in low SNR. In this paper, We propose some multi-modulus blind equalization algorithm scheme. It is a method of operation in some multi-modulus algorithm which does no obstruct a convergence property at the initial equalization in the low SNR. Proposed algorithm improves the steady-state performance. And it uses residual ISI of the equalizer output in order to decide the optimum switching time between the single modulus and the multi-modulus algorithm.

  • PDF

Evaluation of Treatment Efficiency using non-Control Indicator in Drinking Water Treatment Process (미규제 수질인자를 이용한 정수공정의 효율성 평가)

  • Lee Jae-Young;Kang Mee-A
    • The Journal of Engineering Geology
    • /
    • v.16 no.2 s.48
    • /
    • pp.153-159
    • /
    • 2006
  • The discharges of time, technology and finance was increased and it was difficult to use water resources effectively by serious water pollutions. Thus the main aim of this work was focused on effectiveness of water treatment process using non-controlled indicators such as UV absorbance($E_{260}$) and particle counts that provided analytical results with simple and rapid. The soluble aluminum was increased by the increase of aluminum doses for turbidity removals It means that the water quality was not controlled by only turbidity monitoring cause maximum turbidity removal did not guarantee minimum residual aluminum in an aluminum-based coagulation. E removal efficiency appeared to be the promising indicator for monitoring the effectiveness of the water quality process such as coagulation and nanofiltration membranes for arsenic(V). On the basis of the particle monitoring, it was also found that the particle counts could be used very useful for changing the coagulants in real water treatments.

Thermal Release of LiCl Waste Salt from Pyroprocessing (파이로프로세싱 발생 LiCl염폐기물의 열발생)

  • Kim, Jeong-Guk;Kim, Kwang-Rag;Kim, In-Tae;Ahn, Do-Hee;Lee, Han-Soo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.7 no.2
    • /
    • pp.73-78
    • /
    • 2009
  • The decay heat of Cs and Sr contained in a LiCl waste salt, generated from an electrolytic reduction process in pyroprocessing of spent nuclear fuel, has been calculated. The calculation has been carried out under some assumptions that most of the LiCl waste is purified and recycled to main process, and the residual is fabricated to make a waste form. As a result, the decay heat from daughter nuclides such as Ba and Y seems to be maximum 4.6 times higher than that from their parent nuclides such as Cs and Sr. The thermal release from Cs and Sr in the LiCl waste is the maximum around the first one month, so an cooling system operation for some time at the beginning would be suggested to control a rapid increase in the temperature of the LiCl waste salt.

  • PDF

Development of electric safety control system for incapable operation of ELB and MCB using the low voltage distribution line (저압 배전선로의 누전 및 배선용 차단기의 오동작 방지를 위한 전기안전 제어장치 개발)

  • Kwak, Dong-Kurl;Shin, Mi-Young;Jung, Do-Young;Kim, Hyo-Jin;Baek, Seong-Hyun;Choi, Byung-Seub
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.371-372
    • /
    • 2007
  • The major causes of electrical fire are classified to short circuit fault, overload fault, electric leakage and electric contact failure. The occurrence factor of the fire is electric arc or spark accompanied with electrical faults. Residual Current Protective Device (RCD), that is Earth Leakage Circuit Breaker(ELB) and Molded_case Circuit Breaker (MCB), of high sensitivity type used at low voltage wiring cuts off earth leakage and overload, but the RCD can't cut off electric arc or spark to be a major factor of electrical fire. As the RCDs which are applied low voltage distribution panel are prescribed to rated breaking time about 30[ms] (KS C 4613), the RCDs can't perceive to the periodic electric arc or spark of more short wavelength level. To be improved on such problem, this research development is proposed to a auxiliary control apparatus for RCD trip on electric arc or spark due to electrical fire. Some experimental results of the proposed apparatus is confirmed to the validity of the analytical results.

  • PDF

Correction on Current Measurement Errors for Accurate Flux Estimation of AC Drives at Low Stator Frequency (저속영역에서 교류전동기의 정확한 자속추정을 위한 전류측정오차 보상)

  • Cho, Kyung-Rae;Seok, Jul-Ki
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.65-73
    • /
    • 2007
  • This paper presents an on-line correction method of current measurement errors for a pure-integration-based flux estimation down to 1-Hz stator frequency. An observer-based approach is taken as one possible solution of eliminating the dc offset and the negative sequence component of unbalanced gains in the synchronous coordinate. At the same time, the positive sequence component estimation is performed by creating an error signal between a motor model reference and an estimated q-axis rotor flux established by a permanent magnet (PM) in the synchronous coordinate. The compensator utilizes a PI controller that controls the error signal to zero. The proposed technique further contains a residual error compensator to completely eliminate miscellaneous disturbances in the estimated flux. The developed algorithm has been implemented on a 1.1-kW permanent magnet synchronous motor (PMSM) drive to confirm the effectiveness of the proposed scheme.