• Title/Summary/Keyword: residual VOCs

Search Result 12, Processing Time 0.026 seconds

Removal of residual VOCs in a collection chamber using decompression for analysis of large volatile sample

  • Lee, In-Ho;Byun, Chang Kyu;Eum, Chul Hun;Kim, Taewook;Lee, Sam-Keun
    • Analytical Science and Technology
    • /
    • v.34 no.1
    • /
    • pp.23-35
    • /
    • 2021
  • In order to measure the volatile organic compounds (VOCs) of a sample which is too large to use commercially available chamber, a stainless steel vacuum chamber (VC) (with an internal diameter of 205 mm and a height of 50 mm) was manufactured and the temperature of the chamber was controlled using an oven. After concentrating the volatiles of the sample in the chamber by helium gas, it was made possible to remove residual volatile substances present in the chamber under reduced pressure ((2 ± 1) × 10-2 mmHg). The chamber was connected to a purge & trap (P&T) using a 6 port valve to concentrate the VOCs, which were analyzed by gas chromatography-mass spectrometry (GC-MS) after thermal desorption (VC-P&T-GC-MS). Using toluene, the toluene recovery rate of this device was 85 ± 2 %, reproducibility was 5 ± 2 %, and the detection limit was 0.01 ng L-1. The method of removing VOCs remaining in the chamber with helium and the method of removing those with reduced pressure was compared using Korean drinking water regulation (KDWR) VOC Mix A (5 μL of 100 ㎍ mL-1) and butylated hydroxytoluene (BHT, 2 μL of 500 ㎍ mL-1). In case of using helium, which requires a large amount of gas and time, reduced pressure ((2 ± 1) × 10-2 mmHg) only during the GC-MS running time, could remove VOCs and BHT to less than 0.1 % of the original injection concentration. As a result of analyzing volatile substances using VC-P&T-GC-MS of six types of cell phone case, BHT was detected in four types and quantitatively analyzed. Maintaining the chamber at reduced pressure during the GC-MS analysis time eliminated memory effect and did not affect the next sample analysis. The volatile substances in a cell phone case were also analyzed by dynamic headspace (HT3) and GC-MS, and the results of the analysis were compared with those of VC-P&T-GC-MS. Considering the chamber volume and sample weight, the VC-P&T configuration was able to collect volatile substances more efficiently than the HT3. The VC-P&T-GC-MS system is believed to be useful for VOCs measurement of inhomogeneous large sample or devices used inside clean rooms.

연속식 고정층 탑내에서의 휘발성 유기 화합물[VOCs]의 흡착 특성에 관한 연구

  • 최인호;최호석;이현재;구본탁;김인호
    • KSBB Journal
    • /
    • v.15 no.6
    • /
    • pp.578-583
    • /
    • 2000
  • Biofiltration has been identified as a promising method of odor, VOCs and air toxic removal from waste gas streams because of low capital and operating cost, low energy requirements and an absence of residual products requiring further treatment of disposal. Because biofiltration units are microbial systems in-corporationg microorganisms grown on a porous solid media like compost, peat, soil and mixtures of these materials, there is a need to study of the adsorptive behavior of these supports. The purpose of this study was to investigate the major parameters of adsorptive process. We adsorbed VOCs onto peats and bark, and examined the correlations between the interphase mass transfer coefficients and transfer units, at different stream flow rates, VOCs inlet concentrations and bed lengths.

  • PDF

Relation of Groundwater Quality to Land Use on Ulsan Urban area (토지이용도별 울산지역 지하수의 수질특성)

  • Im, Hyun-Chul
    • Journal of the Korean Geophysical Society
    • /
    • v.8 no.3
    • /
    • pp.145-152
    • /
    • 2005
  • 216 groundwater samples for inorganic constituents and 168 samples for VOCs in the Ulsan urban ares and analyzed to relate groundwater chemistry to four land use zones, residence․commercial, industrial, agricultural, and forestry. In general, Na and Cl concentrations in groundwater were high in residence․commercial zone near Taehwa river due to residual saline. Although NO3 contents is high in agricultural zone and VOCs content is high in industrial zone, it seems difficult to relate groundwater pollution to land use zone. Even though groundwater pollution of the area is still low, continuous monitoring is necessary because the city is expanding.

  • PDF

Analysis of Volatile Organic Compounds Emitted from Electronic Parts in PC/Monitor Set (PC/Monitor 구성 전자부품에서 방출되는 휘발성 유기화합물의 분석)

  • Ri, Chang Seop;Choe, Jong Woo;Baek, Kyu Won
    • Journal of the Korean Chemical Society
    • /
    • v.44 no.4
    • /
    • pp.343-349
    • /
    • 2000
  • Volatile Organic Compounds(VOCs) emitted form electronicSince toluene, xylene, cyclohexanone, and benzofuran will bring on the deleterious smell and the health risk, eventhough very small amount of these areexposed to human body, quantitative analysis was achieved by GC-MS system. As a result of these analyses, except PCB(CEM-1) of which is one of the electronic parts, the left of electronic parts represented, imme-diately form 30 minutes to 1 hour after heating, the trends that toluene, xylene, cyclohexanone and phenol were consecuticely emitted very high. and toluene, xylene, phenol, cyclohexanone, and benzofuran from most of the electronic parts were emitted very frequently within the measuring period. Finally, Trans of electronic parts showed the highest concentration of emission, and xylene(550~2482 ${\mu}g/m^2$) was the most noticeably emitting compound of VOCs.

  • PDF

Preliminary Source Apportionment of Ambient VOCs Measured in Seoul Metropolitan Area by Positive Matrix Factorization (PMF를 이용한 수도권지역 VOCs의 배출원 추정)

  • Han J. S.;Moon K. J.;Kim R. H.;Shin S. A.;Hong Y. D.;Jung I. R.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.1
    • /
    • pp.85-97
    • /
    • 2006
  • The PAMS data collected at four sites in Seoul metropolitan area in 2004 were analyzed using the positive matrix factorization (PMF) technique, in order to identify the possible sources and estimate their contributions to ambient VOCs. Ten sources were then resolved at Jeongdong, Bulgwang, Yangpyeong, and Seokmo, including vehicle exhaust, LPG vehicle, petroleum evaporation, coating, solvent, asphalt, LNG, Industry & heating, open burning, and biogenic source. The PMF analysis results showed that vehicle exhaust commonly contributed the largest portion of the predicted total VOCs mass concentration, more than $30\%$ at four sites. The contribution of other resolved sources were significantly different according to the characteristics of site location. In the case of Jeongdong and bulgwang located in urban area, various anthropogenic sources such as coating, solvent, asphalt, residual LPG, and petroleum evaporation contributed about $40\%$ of total VOCs mass. On the other hand, at yangpyeong and Seokmo located in rural and remote area, the portion of these anthropogenic sources was reduced to less than $30\%$ and the contribution of natural sources including open burning and biogenic source clearly observed. These results were considerably corresponding to the emission inventory investigated in this region.

A Field Study on the Evaluation of Slurping and Bioaugmentation Effect in Petroleum Contaminated Area (유류오염지역 정화를 위한 슬러핑과 미생물증진법의 효율평가에 관한 현장 적용성 연구)

  • Park, Eung-Ryeol;Lee, Kwang-Ryeol;Seo, Chang-Il;Cho, Chang-Hwan
    • Journal of Soil and Groundwater Environment
    • /
    • v.17 no.3
    • /
    • pp.32-38
    • /
    • 2012
  • This study was conducted to evaluate the slurping process affecting the variation of free product and VOCs concentration and the bioaugmentation effect on bioremediation process. Free products and soil gas were extracted from 30 extraction wells installed in a petroleum contaminated area. The extraction system was operated for 10 hours per day with 1 hour on-and-off mode. The thickness of free product in extraction well was decreased from 11.7 cm to 4.5 cm and the VOCs concentration was increased from 10.37 ppm to 30.78 ppm during the operation period. After the slurping process for 2 months, contaminated soil was treated with bioremediation process in 2 cells, $15{\times}40$ m, biologically enhanced with adjusting oxygen, moisture and nutrients concentration. Total 1,400 L of microbial inoculant, Naturesys. (Dong Myung Ent. Co.) was added to the pile B, which has an outstanding ability for degrading petroleum hydrocarbons. The results showed that bioremediaton effect in soil with the microorganisms solution is 33% higher than that in soil with only residual bacteria.

Effect of Bacterial Population from Rhizosphere of Various Foliage Plants on Removal of Indoor Volatile Organic Compounds (다양한 관엽식물의 근권부 박테리아 집단이 실내 휘발성 유기화합물질의 제거에 미치는 영향)

  • Chun, Se-Chul;Yoo, Mung-Hwa;Moon, Young-Sook;Shin, Mi-Ho;Son, Ki-Cheol;Chung, Ill-Min;Kays, Stanley J.
    • Horticultural Science & Technology
    • /
    • v.28 no.3
    • /
    • pp.476-483
    • /
    • 2010
  • Total bacterial populations were cultured from the Hydroball cultivation media in the rhizospheres of 9 different plants including $Hedera$ $helix$ L. and $Dracaena$ $deremensis$ cv. Warneckii Compacta, etc. These cultured bacterial populations were studied to test if the bacterial populations in the plant growing pots may play a role on removal of volatile organic compounds (VOCs) such as benzene and toluene in the air. To meet this objective, first, we tested the possibility of removal of VOCs by the cultured total bacteria alone. The residual rates of benzene by the inoculation of total bacterial populations from the different plant growth media were significantly different, ranging from 0.741-1.000 of $Spathiphyllum$ $wallisii$ 'Regal', $Pachira$ $aquatica$, $Ficus$ $elastica$, $Dieffenbachia$ sp. 'Marrianne' Hort., $Chamaedorea$ $elegans$, compared to the control with residual rate of 0.596 (LSD, $P$=0.05). This trend was also similar with toluene, depending on different plants. Based on these results, we inoculated the bacterial population cultured from $P.$ $aquatica$ into the plant-growing pots of $P.$ $aquatica$, $F.$ $elastica$, and $S.$ $podophyllum$ inside the chamber followed by the VOCs injection. The inoculated bacteria had significant effect on the removal of benzene and toluene, compared to the removal efficacy by the plants without inoculation, indicating that microbes in the rhizosphere could play a significant role on the removal of VOCs along with plants.

A Study on Dissolve and Remove Analysis of Pollutants in Drinking Water by Suspected Cancer Causing Organic Chemicals using AOPs (Advanced Oxidation Processes) & M/F Hybird Process (고도산화와 정밀여과막 혼성공정을 이용한 먹는 물에 존재하는 발암원인으로 의심되는 유기화학성분의 분해 및 제거분석에 관한 연구)

  • An, Tai-Young;Park, Mi-young;Hur, Jang-hyun;Jun, Sang-ho;Han, Mi-Ae;An, Yoon-Hee
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.2
    • /
    • pp.193-200
    • /
    • 2007
  • The AOPs research defined by creating a sufficient amount of OH radicals from the dissolution of organic materials through photoxidation and research for a complete elimination of residual organic materials by membrane are actively ongoing. This research focuses on the hybrid processing of AOPs and M/F membrane to dissolve and eliminate organic chemicals in drinking water which are suspected of carcinogens. For this purpose, underground water was used as a source of drinking water for the hybrid processing of AOPs oxidation and M/F membrane, and a pilot plant test device was installed indoor. Carcinogenic chemicals of VOCs and pesticide were artificially mixed with the drinking water, which was then diluted close to natural water in order to examine treatment efficiency and draw optimal operation conditions. The samples used for this experiment include four chemicals phenol, chloroform, in VOCs and parathion, carbaryl in pesticide. As a result of the experiments conducted with simple, and compound solutions, the conditions to sufficiently dissolve and eliminate carcinogenic chemicals from the hybrid processing of where carcinogens were artificially added are : (hydrogen peroxide) prescribed solution 100 mg/L under pH 5.5~6.0, and the temperature $12{\sim}16^{\circ}C$, at the normal temperature and pressure. $d-O_3$ volume of 5.0 ppm and above and 30-40 minutes of reaction time are most appropriate and using MF/UF for membrane was ideal.

Analysis of Volatile Organic Compounds Emitted from Chemical Parts and Monitor Set of PC/Monitor (PC/Monitior 구성 화학부품 및 제품에서 방출되는 휘발성 유기화합물의 분석)

  • Choe, Jong-Woo;Baek, Kyn-Won;Ri, Chang-Seop
    • Journal of the Korean Chemical Society
    • /
    • v.44 no.5
    • /
    • pp.415-421
    • /
    • 2000
  • Volatile organic compounds(VOCs) emitted from PC/Monitor set and chemical parts com-prising of PC/Monitor set were analyzed aran, and xylene of VOCs based on qualitative analysis. As a result of these analyses, when the Wedge Rub-ber of rubber product was heated from 60$^{\circ}C$ to 80$^{\circ}C$, the emission rate(%) of xylene was increased about 2.5 times. But it was evaluated that the left of chemical parts were not affected by temperature except Wedge Rub-ber. The results of qualitative analyses between RGA and GC-MS were a little different respectively. With quantitative analysis, concentration of xylene emitted from cabinet was measured to be maximum as 6029.3 ug/ m$^3$(1.3ppm). The concentrations of toluene, xylene, and benzofuran derived from PC/Monitor set were 10.25${\mu}g/m^3$, 690${\mu}g/m^3$, and 180 ${\mu}g/m^3$, and these concentrations were relatively high levels which can bring on the risk to human health.

  • PDF

Ecotoxicological effects of ballast water effluent teated by an electrolytic method on marine environment

  • Kim, Tae Won;Kim, Keun-Yong;Shon, Myung-Baek;Kim, Young-Soo;Lee, Ji Hyun;Moon, Chang Ho;Son, Min Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.8
    • /
    • pp.1010-1020
    • /
    • 2014
  • Ballast water effluent treated by an electrolytic method contains reactive chlorine species and disinfection by-products (DBPs). In this study, we conducted whole effluent toxicity (WET) testing and ecological risk assessment (ERA) to investigate its ecotoxicological effects on marine environment. WET testing was carried out for three marine pelagic organisms, i.e., diatom Skeletonema costatum, rotifer Brachionus plicatilis and fish Paralichthys olivaceus. The biological toxicity test revealed that S. costatum was the only organism that showed apparent toxicity to the effluent; it showed no observed effect concentration (NOEC), lowest observable effect concentration (LOEC) and effect concentration of 50% (EC50) values of 12.5%, 25.0% and 83.3%, respectively, at brackish water condition. In contrast, it showed insignificant toxicity at seawater condition. B. plicatilis and P. olivaceus also showed no toxicities to the effluent at the both salinity conditions. Meanwhile, chemical analysis revealed that the ballast water effluent contained total residual oxidants (TROs) below $0.03{\mu}g/L$ and a total of 20 DBPs including bromate, volatile halogenated organic compounds (VOCs), halogenated acetonitriles (HANs), halogenated acetic acids (HAAs) and chloropicrin. Based on ERA, the 20 DBPs were not considered to have persistency, bioaccumulation and toxicity (PBT) properties. Except monobromoacetic acid, the ratio of predicted environmental concentration (PEC) to predicted no effect concentration (PNEC) of the other 19 DBPs did not exceed 1. Thus, our results of WET testing and ERA indicated that the ballast water effluent treated by electrolysis and subsequently neutralization was considered to have no adverse impacts on marine environment.