• Title/Summary/Keyword: residential distribution

Search Result 451, Processing Time 0.026 seconds

Patterns of the main VOCs concentration in ambient air around Shiwha Area (시화공단 지역의 주요 휘발성물질 농도 분포 특성)

  • Byeon, Sang-Hoon;Lee, Jeong-Geun;Kim, Jeong-Keun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.1
    • /
    • pp.61-68
    • /
    • 2010
  • In this study, we investigated the concentrations of volatile organic compounds (VOCs) in Shiwha area and compared the characteristics of both industrial area and residential area. The passive samplers were set 6 times each for a month in 21 locations at industrial and residential area to obtain 6 VOCs including benzene, trichlorobenzene, toluene, ethyl benzene, xylene and stylene. Above all, toluene was the most abundant VOCs in the ambient air both in industrial and residential area. Average TVOC concentration of industrial area was 1.86 times higher than that of residential area, and it was greatly reduced in winter compared with summer. Furthermore, the average BTEX concentrations showed that all concentrations of industrial area were 1.94~5.39 times higher than those of residential area except benzene which were similar to each other. In winter, the concentration of ethyl benzene and xylene were significantly decreased by comparing with summer: but benzene concentrations were increased. Also, BTEX relative ratio was as follows: toluene>benzene>ethylbenzene>xylene. Correlation coefficients among VOCs were confirmed that VOCs in ambient air of industrial area were generally more related to each other than that of residential area. On the whole, the concentrations of VOCs in industrial area were higher, and it seems to be potential that industrial area affects the distribution of VOCs to residential area.

Evaluation of Heavy Metal Pollution in Soil on the Playgrounds for Children in I area (I시 어린이 놀이터의 토양 중 중금속 오염에 관한 연구)

  • 이충대;이윤진;조남영
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.3
    • /
    • pp.57-62
    • /
    • 2001
  • The study was conducted to measure the heavy metal pollution of soils at the playground for children and to investigate the characteristics of heavy metals distribution I city. The studied area was divided into two: the residential area and the industrial area. The samples of the sands and soils were collected from both areas. The results were obtained as follows. All average concentration of 6 different heavy metals was found to be lower than the standard of soil pollution. Zn, Pb and cu concentrations were higher than other species of heavy metals. The contents of heavy metals in the soil were higher than the sands. The average contents of Zn, Pb, Cu, As, Hg and Cd in soil were 38.36, 9.53, 7.31, 0.03, 0.18 and 0.09 mg/kg respectively. Comparing with the residential area, heavy metal concentrations of the industrial area were 4.60, 1.49, 2.60 and 4.29 times for Zn, Pb, Hg and Cd in soils, respectively.

  • PDF

Estimation Method of Variable Composition Rate and Error Compensation Method of Aggregative Model for Reactive Power by Variable Composition Rate (가변구성비 추정기법과 이를 이용한 무효전력 축약모델의 오차보정기법 개발)

  • Lee, Dae-Jong;Lee, Jong-Pil;Lim, Jae-Yoon;Ji, Pyeong-Shik
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.60 no.4
    • /
    • pp.186-192
    • /
    • 2011
  • Recently, due to the expansion of electric power demands, nonlinear load such as converters and inverters connected to the electric power distribution system, and extensive application of harmonic generation sources with power electric devices, disturbance of the electric power system and its influences on industries have been continuously increasing. In this research, we develop a novel aggregation algorithm by considering the harmonics characteristics for residential loads. Using data sets acquired from various experiments, we analyzed load characteristics according to harmonics and presented the results obtained the proposed method.

Development of Current Harmonics Estimation Method by Considering the Characteristics of Input Voltage (인가전압의 특성을 고려한 주거용 부하의 전류성분 추정기법 개발)

  • Ji, Pyeong-Shik
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.60 no.4
    • /
    • pp.181-185
    • /
    • 2011
  • Due to the increasing of nonlinear loads such as converters and inverters connected to the electric power distribution system, and extensive application of harmonic generation sources with power electronic devices, disturbance of the electric power system and its influences on industries have been continuously increasing. Thus, it is difficult to construct accurate load model for active and reactive power in environments with harmonics. In this research, we develop current harmonics estimation method based on Extreme Learning Machine (ELM) with fast learning procedure for residential loads. Using data sets acquired from various residential loads, the proposed method has been intensively tested. As the experimental results, we confirm that the proposed method makes it possible to effective estimate current harmonics for various input voltage.

Deriving Ecological Protective Concentration of Cadmium for Korean Soil Environment

  • Lee, Woo-Mi;Nam, Sun-Hwa;An, Youn-Joo
    • Environmental Engineering Research
    • /
    • v.18 no.4
    • /
    • pp.241-246
    • /
    • 2013
  • For effective and efficient environmental management, developed countries, such as the Netherlands, UK, Australia, Canada, and United States apply ecological risk assessment, and they have an autonomous risk assessment methodology to protect native receptors. In this study, soil ecological protective concentration (EPC) of cadmium in Korea was derived using Korean ecological risk assessment methodology. The soil EPC of cadmium was calculated using probabilistic ecological risk assessment based on species sensitivity distribution. The soil EPC was calculated according to land use for residential/agricultural and industrial/commercial purposes. The chronic soil EPCs for residential/agricultural and industrial/commercial lands were derived to be 1.58 and 9.60 mg/kg, respectively. These values were similar to soil EPC of European Commission, the Netherlands, UK, and Canada. However, these values were lower than the established Korean soil standard, because the current soil standard was based on human risk. Therefore, the impact on an ecosystem when establishing environmental standard should be considered.

Analysis of Characteristics of Residential Distribution Line for PLC Modem Design (PLC 모뎀설계를 위한 옥내 배선 특성분석)

  • Hong, Duc-Pyo;Lee, Jin-Mok;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1524-1526
    • /
    • 2005
  • This paper describes the measurement and analysis of the basic line constants in PLC(Power Line Communication) in the residential building. An apartment is considered as one of the conventional residences to get the line constants in this paper and Agilent 4263B LCR Meter is used to measure the detailed values each area and the specific results and the averaged analysis data are shown in the tables. The measured results no different from the calculated values with using conventional formula due to the line arrangement neglected factors, complex permittivity, and etc. Also, this paper describes many kinds of lines and wiring figures of domestic construction. Finally, it is utilized with the analyzed line characteristics in frequency domain as a planning reference of PLC.

  • PDF

An Assessment on Harmonics Effect in Customer and the Distributed Power System during Grid Connection of Residential Fuel Cell System (가정용 연료전지 시스템의 계통연계 시 수용가 및 배전계통에서의 고조파 영향 평가)

  • Park, Chan-Eom;Jung, Jin-Soo;Han, Woon-Ki
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.6
    • /
    • pp.1280-1285
    • /
    • 2011
  • Recently, due to the use of fossil fuels for electric power production, carbon emissions increased excessively. Thereby, in order to replace fossil fuels, many studies about fossil fuels such as solar and fuel cell energy source are progressing. Fuel cell system has high energy conversion efficiency. Also, fuel cell system is environmentally friendly system because the carbon emission is almost not occur. Therefore, the fuel cell system is considered as the core technology of in the fields of the future energy and environmental. Fuel cell system has an effect on distribution power system because another power source of other than large power plants. So, fuel cell system can be degradation reason of power quality in the power system. In this paper, we constructed the system for an assessment on harmonics effect. The system is composed with power source, harmonics generation and linear load, fuel cell system. we also performed assessment on harmonics effect in customer and the distributed power system during grid connection of residential fuel cell system. An assessment cases are divided into three. A Case 1 is state that residential load and fuel system are connected to grid, Case 2 is state that residential load and harmonics load are connected to grid, and Case 3 is state that all loads are connected to grid. As a output of fuel cell system is increase, analysis results based on assessment system showed that power quality became more aggravation as effect of harmonics.

Geomorphological Environments of High-density Residential Zone in Baekseokdong, Cheonan, Chungnam in the Bronze Age (충남 천안 백석동 청동기 시대 주거지 밀집 구역의 지형 환경)

  • Park, Jong-Chul;Park, Ji-Hoon
    • Journal of the Korean association of regional geographers
    • /
    • v.17 no.3
    • /
    • pp.297-312
    • /
    • 2011
  • Understanding the distribution and location characteristics of the settlements is preliminary study on discovering the formation and extinction process of the settlements used information of archeological excavation. So far, most researchers have been concerned about the location-environment of the dwelling. However, this study focuses on the understanding of the geomorphological environments in high-density residential zone. The study area is located in Cheonan, Chungnam, South Korea. It is called the Baekseokdong Heritage Group, which has 205 dwelling sites in the bronze age. This study is considered micro-landforms of hillslope, slope, and aspect from a view of geomorphological environments. In the study area, The high-density residential zones, the bronze ages dwelling sites are concentrated, consists mainly of slope land between undulated plain and semi -gentle of crest slope or crest flat, and south-facing aspect(southwest-south-southeast).

  • PDF

A Study on the Proposal of Building Technologies for Reducing $CO_2$ Emission of Buildings(Focused on the Multi-Family Residential Buildings) (건물의 $CO_2$ 배출 저감 건축기술요소 제안에 관한 연구(공동주택을 중심으로))

  • Lee, Jong-Sik;Kang, Hae-Jin;Park, Jin-Chul;Rhee, Eon-Ku
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.91-96
    • /
    • 2009
  • First, the base model of multi-family residential buildings are selected, and then the $CO_2$ reduction building technologies that are applicable for multi-family residential buildings are induced by analyzing the examples and then an optimal plan for when the $CO_2$ reduction building technologies can be integrated and applied to the base model was formulated. In the results of converting the energy consumption and reduction amount from the building technologies into $CO_2$ emissions to analyze the distribution ratio compared to the entire $CO_2$ emissions; the heat recovery ventilator is 0.5%, the photovoltaic system is $1.9%{\sim}5.9%$, the solar hot water heating system is $6.3%{\sim}13.1%$ and the ge thermal heat-pump system is 39.0% when both heating and hot water heating are applied. An optimally integrated application method for the building technologies is in charge of heating and hot water heating through the geothermal source heat pump system and in charge of the electricity load through the photovoltaic system(45.2%).

  • PDF

Detection of Airborne Respiratory Viruses in Residential Environments (주거환경 공기 중 호흡기 바이러스의 검출)

  • Park, Keun-Tae;Moon, Kyong-Whan;Kim, Hyung-Tae;Park, Chan-Jung;Jeong, Ho-Chul;Lim, Young-Hee
    • Journal of Environmental Health Sciences
    • /
    • v.37 no.4
    • /
    • pp.306-314
    • /
    • 2011
  • Objectives: Respiratory virus infections are the most common disease among all ages in all parts of the world and occur through airborne transmission. The purpose of this study was to detect and quantitate human respiratory viruses in residential environments. Methods: Air samples were collected from the residential space of apartments in the Seoul/Gyeonggi-do area. The samples were collected from indoor and outdoor air. Among respiratory viruses, influenza A virus, influenza B virus, parainfluenza virus, metapneumovirus, respiratory syncytial virus, and adenovirus were investigated by multiplex polymerase chain reaction. Among the virus-positive samples, we performed adenovirus quantification by real-time polymerase chain reaction. Results: Virus detection rates were 44.0%, 3.8%, 3.4%, and 17.3% in spring, summer, autumn, and winter, respectively. The virus detection rate was higher in winter and spring than in summer and autumn. Adenovirus was most commonly detected, followed by influenza A virus and parainfluenza virus. Virus distribution was not significantly different between indoor and outdoor environments. Conclusions: Although virus concentrations were not high in residential environments, residents in houses with detected viruses may have an increased risk of exposure to airborne respiratory viruses, especially in winter and spring.