• Title/Summary/Keyword: residential concentration

Search Result 357, Processing Time 0.026 seconds

Studies on the Heavy Metal Content of Ginkgo Leaves Growing in All Around Seoul (서울지역 은행엽중 중금속 함량에 관한 연구)

  • 김민영;강희곤;길혜경
    • Environmental Analysis Health and Toxicology
    • /
    • v.4 no.1_2
    • /
    • pp.35-45
    • /
    • 1989
  • Studies on the heavy metal content of ginkgo leaves growing in all around Seoul. This study was carried out to investigate the concentration of heavy metals and soluble sulfur in ginkgo leaves. These leaves are found growing in park, residential, commercial and industrial areas all around Seoul. These analyzed the quantity of Cd, Co, Cu, Fe, Mn, Ni, Pb, Zn, Hg and soluble surfur in separate samples of washed and unwashed leaves. The results were as follows: 1. This order of heavey metal concentration was found in Seoul area,: Fe>Mn>Zn>Ni>Pb>Cu>Co>Cd>Hg. 2. Pb concentration was higher in the commercial area than in the other areas, and it concentration in washed leaves was higher 96~100% and unwashed leaves 85~170%. 3. In the residential area Ni concentration was significantly higer where about seven times more Ni as found on the top part of the leaves. 4. Water soluble surfur was higest in the inudstrial area, but the percentage on top of the leaves was only 0.04~0.05% simillar with other area. 5. Fe, Zn and Ni were almost positively correlated to each component but negatively correlated between Mn and souble sulfer. All of content except Mn and Ni were significance between each area in washed and unwashed leaves.

  • PDF

A Study on Characteristics of Fire Temperature and Concentration of Toxic Gases while the Door Opening or Closed on Multi-layered Construction (복층건물의 출입문 개방여부에 따른 화재온도분포 및 독성가스 농도 변화특성에 관한 연구)

  • Lee, Jungyun;Kim, Jeonghun;Kim, Eungsik;Kim, Hong
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.2
    • /
    • pp.72-77
    • /
    • 2017
  • In S. Korea, recently, building fire accidents of residential accommodations or recreational facilities have taken place more frequently than before. Among various building constructions, Multi-layered structure, such as office-residential complex, are mostly made in S. korea. $O_2$, $CO_2$, CO, $NO_x$, $SO_x$, and HCl, these gases has toxic hazard and harmful for human body. And it is predicted that different concentration of released gases from diesel pool fire with upper and lower layer. Therefore, this study reports the fire characteristics of Multi-layered structure by analyzing the fire behavior and concentration of combustion gases of a experimental compartment via real scale fire experiment, in order to predict risks and secure safety for similar fire accidents.

A study on the characteristics of wastewater flowrate in land-use of Sogwipo-city in Cheju (제주도 서귀포시지역의 용도지역별 하수발생량 특성에 관한 연구)

  • Jeong, Gwang Ok;Ryu, Seong Pil
    • Journal of Environmental Science International
    • /
    • v.13 no.3
    • /
    • pp.251-262
    • /
    • 2004
  • To identify the characteristics of wastewater flow generated in treatment basins of Seogwipo-city, we selected 3 stations representing the basin and performed 7 times of field survey including 5 times in dry periods and 2 times in wet periods from Feb. 25 to May 27, 2002 for the selected stations. From the analysis of flow data measured for more than 60 days in the interval of 5 minutes and concentration data obtained from laboratory analysis, we can draw several conclusions. First, in the analysis of diurnal variation of wastewater flow for land-use types, we could find the following results: in the residential area, it is observed that wastewater flow rates rise early in the morning for the office-going hour and fall gradually and rise again after the office-leaving hour, showing typical residential wastewater flow pattern, while for the residential and commercial area flow rates rise early in the morning at the office-going hour and move up and down repeatedly within wide range and last till the office-leaving hour, which can be resulted from wastewater that is generated by tourists activated after early in the afternoon, while for the touristy area flow rates rise early in the morning and fall gradually and rise again within wide range. Second, in the analysis of temporal variation of wastewater flow for monthly, it can be observed that in the residential area, in the residential and commercial areas the flow rate of May is higher than that of Feb., March, while for the touristy area flow rate is without monthly because it reflects the movement of population, Third, in wet periods concentration of water-quality item such as SS, BOD, and COD_{cr}$ is high in the beginning of rainfall by first flush, and falls down gradually to reach the steady state, which is the level of wastewater in dry periods after the cease of storm water due to diluting effect resulting from additional runoff water through storm sewers.

Characteristics of Hazardous Volatile Organic Compounds (HVOCs) at Roadside, Tunnel and Residential Area in Seoul, Korea (서울시 도로변, 터널 및 주거지역 대기 중 유해 휘발성 유기화합물의 특성)

  • Lee, Je-Seung;Choi, Yu-Ri;Kim, Hyun-Soo;Eo, Soo-Mi;Kim, Min-Young
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.5
    • /
    • pp.558-568
    • /
    • 2011
  • Hazardous volatile organic compounds (HVOCs) have been increasingly getting concern in urban air chemistry due to photochemical smog as well as its toxicity or potential hazards. In this study, we investigated their concentrations and the properties in tunnel, urban roadside and residential area. As a result, among 36HVOCs measured in this study, BTEX (benzene, toluene, ethylbenzene, xylene) and dichlorodifluoromethane, 1,2,4-trimethylbenzene, trichlorofluoromethane were detected above the concentration of $1{\mu}g/m^3$ in every sampling site and the most abundant compound was toluene. The other compounds were detected at trace level or below the detection limit. In addition, we found that three CFCs (chlorofluorocarbons), such as CFC-12, CFC-11, CFC-113, were persistently detected because of the emission in the past. Toluene to benzene ratio (T/B) at tunnel and roadside were calculated to be 4.3~5.3 and at residential area 15.4, suggesting that the residential area had several emission sources other than car exhaust. The ratio of X/E (m,p-xylene to ethylbenzene) ratio was calculated to be 1.8~2.1 at tunnel, 1.7 at roadside and 1.2 at residential area, which means this ratio reflected well the relative photochemical reactivity between these compounds. Good correlation between m,p-xylene and ethylbenzene ($r^2$ > 0.85) were shown in every study sites. This indicated that correlation between $C_2$-alkylbenzenes were not severely affected by 3-way catalytic converter. In this study, it was demonstrated that the concentration of benzene was very low, compared with national air quality standard (annual average of $5{\mu}g/m^3$). Its concentration were $2.52{\mu}g/m^3$ in roadside and $1.34{\mu}g/m^3$ in residential area. We thought this was the result of persistent policy implementation including the reduction of benzene content in gasoline enforced on January 1, 2009.

Characteristics of Hazardous Air Pollutants in the Steel Industrial City, Pohang ( I ) - Polycyclic Aromatic Hydrocarbons (철강산업도시 포항지역 유해대기오염물질의 오염특성 ( I ) - 다환방향족탄화수소)

  • Baek, Kyung-Min;Seo, Young-Kyo;Cho, Byoung-Yoon;Baek, Sung-Ok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.2
    • /
    • pp.233-243
    • /
    • 2018
  • This study was carried out to characterize the ambient levels of PAH concentrations in Pohang city, where steel industry has been intensively developed. A large amount of PAH emissions from steel production and related industries in Pohang are concerned about the environmental health hazards of nearby residents. TSP samples were seasonally collected during 10 days at four sites in Pohang from April to December 2010. Each sample was collected for 24 hours using high-volume air sampler. All samples were extracted by $soxtec^{TM}$ before concentration of 1.0 mL. The concentrates were analyzed by GC/MS. The prevailing wind direction was southwest and west-southwest in Pohang during the measurement period. Variations of TSP concentrations appeared to be similar between four sites. The highest TSP concentration was found in fall, while the lowest in summer. The highest PAH concentration was found at an industrial site, while the lowest at a residential/commercial site. In the case of BaP, the average concentration at the industrial site was $0.63{\pm}0.66ng/m^3$, which was approximately 2 times of the residential/commercial site. The paired t-test (p<0.05) showed significant differences between industrial and residential area. Particulate PAH concentrations were higher in the winter and lower in the summer. The concentrations of BaP in winter were 2~10 times higher than those in the other three seasons. This study clearly demonstrated the impact of steel industry on the elevated levels of PAH in Pohang city.

Efficiency of Removal for PM10 and $NO_2$ by Air Cleaner in Residential Indoor Environment with Monte-Carlo Simulation (확률론적 모의실험을 이용한 공기청정기의 실내공기중 PM10과 $NO_2$ 제거효율에 관한 연구)

  • Lee , Cheol-MIn;Kim , Yoon-Shin;Lee , Tae-Hyung;Kim , Jong-Cheol;Kim , Jung-Ho
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.3
    • /
    • pp.221-229
    • /
    • 2004
  • We estimated decreasing rate of indoor air pollutants which are PM10 and $NO_2$ by the air cleaner in indoor environment. This study respectively examined concentration of PM10 and $NO_2$ two times in 34 sites located in Seoul and Kyung-gi Do from April to September in 2003. Sectional period was respectively divided for operating the air cleaner and non-operating the air cleaner. Moreover, questionnaire was executed to grasp physical characteristic of objective building and residential characteristic of residents by using method of self-entry. There was a trend that concentration of PM10 and $NO_2$ separated number of residents during operating period respectively decreased among indoor air. According to the existence of smoker in indoor, both concentration of PM10 and $NO_2$ during operating period decreased in each case, and according to existence of pets, both cases decreased concentration of pollutants by operating the air cleaner. We used Monte-Calro simulation to remove uncertainty and identify efficiency of eliminated pollutants such as PM10 and $NO_2$ by the air cleaner. Average efficiency of removal for PM10 and $NO_2$ were 61.84${\pm}$23.04% and 48.67${\pm}$18.03% respectively.

Runoff Characteristics of Non-point Pollutants Source in Suwon City (수원시 비점오염물질의 유출 특성)

  • Chi, Hong-Jin;Lee, Sang-Eun;Lee, Jae-Dong
    • Journal of Environmental Science International
    • /
    • v.22 no.4
    • /
    • pp.493-505
    • /
    • 2013
  • This study was to investigate the runoff characteristics of non-point pollutants source at the urban area in Suwon city. The highest T-N and T-P concentration of rainfall runoff observed in agricultural area. In residential area, the highest $BOD_5$ and SS concentration of rainfall runoff was investigated. During rainfall events, the peak concentrations of SS and $BOD_5$ were observed after 1~2 hours of rainfall in urban area. Whereas, the peak concentrations occurred within 1~2 hours after rainfall and then the highest concentrations of SS and $BOD_5$ sharply decreased, showing strong first flush effect in urban area. The EMC results indicated that the highest value of T-N and T-P in agricultural area was observed. While residential area was shown the lowest EMC value as T-N and T-P. Non-point pollutant loads on the land use types in urban area were investigated in the order of residential>industrial>agricultural>highway. $BOD_5$ and SS loads on urban watershed were investigated in the order of Suwon>Hwangguji>Seoho>Wonchunri. Whereas, T-N and T-P loads on urban watershed were investigated in the order of Hwangguji>Suwon>Wonchunri>Seho.

A Study on the Level of Air Pollution and Noise in Pusan Area (부산의 지역별 대기오염과 소음정도에 관한 조사연구)

  • Cho, G.I.;Moon, D.H.;Lee, J.T.;Sin, H.R.;Kim, Y.W.;Park, H.J.;Pae, K.T.;Lee, C.U.
    • Journal of Preventive Medicine and Public Health
    • /
    • v.23 no.4 s.32
    • /
    • pp.391-403
    • /
    • 1990
  • In order to assess the degree of atmospheric pollution and noise and to contribute the health improvement of residents in Pusan, the author measured the levels of CO, $SO_2,\;NO_2$, TSP, HCHO and noise in 8 areas (industrial, residential and park areas) from January to March in 1990. The results were as follows : 1. Sasang industrial area was significantly higher($2.85{\pm}0.84ppm$) in the average concentration of CO than other areas. However, there no areas to affect the human body in terms of CO concentration. 2. In general, industrial area was significantly higher ($0.134{\pm}0.084ppm$) in the average concentration of $SO_2$ than other areas, and it was the lowest ($0.009{\pm}0.005ppm$) in the Namchon-dong area. 3. Industrial ($0.033{\pm}0.009ppm$) and residential area ($0.029{\pm}0.004ppm$) were significantly higher in the average concentration of $NO_2$ than Park area ($0.009{\pm}0.001ppm$). However, there were no areas to affect the human body in terms of $NO_2$ concentration. 4. Sasang industrial area was the highest ($580.4{\pm}415.26{\mu}g/m^3$) at the average concentration of TSP and Hae-Un Dae area was the lowest ($97.22{\pm}37.86{\mu}g/m^3$). But TSP concentration showed the level to affect the human body in most areas. 5. Industrial area was significantly higher ($2.25{\pm}1.15ppb$) in the average concentration of HCHO than residential ($1.13{\pm}0.25ppb$) and park area ($1.33{\pm}0.20ppb$). 6. Industrial area was significantly higher ($77.28{\pm}6.92dB(A)$) in the level of noise than residential ($65.77{\pm}3.76dB(A)$) and park area ($64.65{\pm}5.25dB(A)$). In comparison with regional Standard Noise Level, howeverm the average noise level of residential and park area was higher than that of the Standard. In general, the level of pollution of industrial complex areas was relatively higher than those of residential and park areas. Among the industrial areas, sasang area was worst in most items. Both $SO_2$ and TSP showed the level to affect the human body in most of studied areas. It is necessary to install a new Air Quality Standard for HCHO to screen our environmental pollution.

  • PDF

A Study on the Spatial Characteristics of Senior Residential Complexes (노인 거주 복합시설의 공간 특성에 관한 연구)

  • Lee, Eun-Ryung;Soh, Jun-Young;Lee, Sang-Ho
    • Korean Institute of Interior Design Journal
    • /
    • v.17 no.2
    • /
    • pp.67-74
    • /
    • 2008
  • In Korea, multi-functional senior residential complexes have become very popular since the end of 1990 by integrating the functions of nursing homes and health care facilities, so that the elderly can maintain their regular healthy life and receive health care when needed depending on their aging stage. Accordingly, it is increasingly important to conduct research on such multi-functional residential facilities. In this study, 6 cases of Korean senior residential complexes and 6 cases of comparable Japanese facilities, which were built earlier than Korea, are compared, and the following results are derived from the comparison. 1. In terms of the shared space, the parallel type and the unified type are found to share more space among complex types. Especially, the low-story concentration type and the eccentric type are found to share space the most. 2. In Korea, an average shared rate is found to be 46.8%; and the rates of a supplied-space, a common-shared-space, and a maintenance-space are found to be 29.73%, 36.33%, and 32.93%, respectively. In Japan's case, an average shared space is found to be 22.31%; and the corresponding rates for the above 3 spaces.

Configuring a Residential Hologram System to Complement the Cognitive Function of the Elderly (고령자 인지기능 지원을 위한 주택 내 홀로그램 시스템 구성)

  • Lee, Eun-Ji;Park, Sung-Jun
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.11
    • /
    • pp.67-74
    • /
    • 2018
  • With the rapid increase in the elderly population, numerous problems arise related to the decreased cognitive function such as the declines of reaction time and concentration which are both resulting from ageing. Recently, ICT-based smart home and other residential services are being developed as a means of complementing human cognitive functions, but the elderly, who are in most cases digital-illiterate, find it hard to utilize these tools actively and if so it usually takes longer time and endeavor for the elderly to be familiarized with ICT devices. In this context, this study suggests a configuration of the holographic system in houses that complement the cognitive function of the elderly with the consideration of the interaction with the vision which is a critical function in the cognitive process. The method of this study consists of a literature review on topics including the characteristics of the cognitive function among the elderly, holographic technology and residential services; a configuration of residential services for different space types, depending on the aspects of the cognitive function among the elderly; and finally a suggestion of a holographic system configuration and application depending on various scenarios.