• 제목/요약/키워드: research tendon

검색결과 217건 처리시간 0.028초

Reconstruction of the Heel and Distal Leg Using Pedicled Dorsalis Pedis Island Flap (유경 족배 도서형 피판을 이용한 족부 및 하지 원위부 재건술)

  • Lee, Mun-Mo;Yu, Chang-Eun
    • Archives of Reconstructive Microsurgery
    • /
    • 제12권2호
    • /
    • pp.112-118
    • /
    • 2003
  • Purpose : Soft tissue defect and exposed tendons and bones with concomitant infection in the foot and lower leg have to be covered with vascularized flap as the one stage treatment. Authors have performed 6 cases of pedicled dorsalis pedis island flaps under the loupes magnification and evaluated the benefits. Materials and methods : From 1994 through 2003, we have performed 6 pedicled dorsalis pedis island flaps for reconstruction of soft tissue defects in the foot and lower leg. The causes were trauma in 3 cases, skin necrosis and secondary infection after Achilles tendon repair in 2 cases and acute osteomyelitis in 1 case. Average age was 38 years and 5 cases were male and 1 female. The results of the procedure was evaluated by survival of the island flap, comfort in putting on shoes and walking, comfort in the donor site, comfort in the recipient site and range of motion of the ankle joint. Results : All pedicled dorsalis pedis island flaps survived except 1. Three cases felt discomfort in the dorsum of foot as the donor site and 1 case of the Achilles tendon ruptured and repaired showed limited dorsiflexion of ankle joint. Conclusion : Nonmicrosurgical pedicled dorsalis pedis island flaps under the loupes magnification are one of the useful treatment methods because procedure is rapid, survival is confident and overall reconstructive results are good.

  • PDF

Comparison of Totally Prefabricated Bridge Substructure Designed According to Korea Highway Bridge Design (KHBD) and AASHTO-LRFD

  • Kim, Tae-Hoon
    • International Journal of Concrete Structures and Materials
    • /
    • 제7권4호
    • /
    • pp.319-332
    • /
    • 2013
  • The purpose of this study was to investigate the design comparison of totally prefabricated bridge substructure system. Prefabricated bridge substructure systems are a relatively new and versatile alternative in substructure design that can offer numerous benefits. The system can reduce the work load at a construction site and can result in shorter construction periods. The prefabricated bridge substructures are designed by the methods of Korea Highway Bridge Code (KHBD) and load and resistance factor design (AASHTO-LRFD). For the design, the KHBD with DB-24 and DL-24 live loads is used. This study evaluates the design method of KHBD (2005) and AASHTO-LRFD (2007) for totally prefabricated bridge substructure systems. The computer program, reinforced concrete analysis in higher evaluation system technology was used for the analysis of reinforced concrete structures. A bonded tendon element is used based on the finite element method, and can represent the interaction between the tendon and concrete of a prestressed concrete member. A joint element is used in order to predict the inelastic behaviors of segmental joints. This study documents the design comparison of totally prefabricated bridge substructure and presents conclusions and design recommendations based on the analytical findings.

Feasibility Study of Estimating Prestress Force of Grouted Tendons (종진동특성을 이용한 부착식 텐던의 긴장력 추정 타당성 연구)

  • Kim, Byeong Hwa;Jang, Jung Bum;Lee, Hong Pyo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • 제30권2A호
    • /
    • pp.103-111
    • /
    • 2010
  • A feasibility study for nondestructively estimating prestress force of a grouted tendon using axial vibrations has been investigated. Total eight prestressed concrete beams with different stress levels have been specially designed and constructed for this investigation. The various axial vibration tests have been conducted in order to extract the dynamic characteristics of the prestressed concrete beams. It turns out that the axial frequency, elastic wave velocity and elastic modulus are nonlinearly increased as the prestress force level increases. It seems that the axial vibration characteristics of the existing grouted tendons are a feasible indicator for the identification of their tensile force.

Applications of Gelatin in Food and Biotechnology

  • Yang, Jae-Sung
    • Preventive Nutrition and Food Science
    • /
    • 제2권3호
    • /
    • pp.263-268
    • /
    • 1997
  • Gelatin is a high molecular weight polypeptide derived fro mcollgen, theprimary protein component of animal connective tissues, which include bone, skin and tendon. Gelatin is usually produced from two different sources of raw materials (skins or bones) which are processed in two ways(line or acid). According to this pretreatment, gelatin can be divided into elatin type A(acid) and B(lime). The market is essentially driven by thre demand sectors: food, harmaceuticals(capsules) and photography. Although there is some potential threat in the photography sector, the oher tow sectors are well placed for futher growth.

  • PDF

Reconstruction of the Extremities with the Dorsalis Pedis Free Flap (족 배 유리 피부판을 이용한 사지 재건술)

  • Lee, Jun-Mo;Kim, Moon-Kyu
    • Archives of Reconstructive Microsurgery
    • /
    • 제8권1호
    • /
    • pp.77-83
    • /
    • 1999
  • The skin on the dorsum of the foot is a source of the reliable thin and sensory cutaneous free tissue transplantation with or without tendon, bone and joint. A composite flap with attached vascularized tendon grafts for the combined loss of skin and tendon on the dorsum of the hand and foot offers an immediate one stage solution to this problem. The flap provides a very durable innervated tissue cover for the heel of the foot and the dorsum of the hand and an osteocutaneous transfer combined with the second metatarsal. The major dorsalis pedis artery is constant in size, but the first dorsal metatarsal artery is variable in size and location. The dorsal surface of the foot receives sensory innervation through the superficial peroneal nerve and the first web through the deep peroneal nerve. Authors had performed 5 dorsalis pedis free flap transplantation in the foot and hand at Department of Orthopedic Surgery, Chonbuk National University Hospital from August 1993 through August 1997 and followed up for the period of between 19 and 67 months until March 1999. The results were as follows 1. 5 cases dorsalis pedis free flap transfer to the foot(4 cases) and the hand(1 case) were performed and the recipient was foot dorsum and heel 2 cases each and hand dorsum 1 case. 2 All of 5 cases(100%) were survived from free flap transfer and recipient artery was dorsalis pedis artery(2 cases), anterior tibial artery(1 case), posterior tibial artery(1 case) and ulnar artery(1 case) and recipient veins were 2 in number except in the hand. 3. Long term follow up of the exterior and maceration was good and sensory recovery was poor 4. Donor site was covered with full thickness skin graft obtained from one or both inguinal areas at postoperative 3rd week and skin graft was taken good and no morbidity was showed.

  • PDF

Stabilization of Recurrent Medial Shoulder Luxation by Use of Three Bone Anchors in a Dog (재발성 내측 어깨 탈구를 보이는 개에서 본 앵커를 이용한 외과적 치료 증례)

  • Yoon, Hun-Young;Roh, Mi-Young;Jeong, Soon-Wuk
    • Journal of Veterinary Clinics
    • /
    • 제30권1호
    • /
    • pp.45-48
    • /
    • 2013
  • A 12-year-old male poodle weighing 2.0 kg presented for evaluation of right thoracic limb lameness. The owner reported that the dog showed recurrent bilateral shoulder joint luxation after a car accident for a year. Recently, the left shoulder joint appeared well maintained, but right shoulder joint luxation was exacerbated. On physical examination, the dog showed non-weight bearing lameness on the right thoracic limb. Craniocaudal radiographic views revealed medial displacement of the right humerus. Mediolateral radiographic views revealed overlap of the glenoid cavity and humeral head. Muscle atrophy of the right thoracic limb, reduced biceps brachii muscle tendon tone, a tear of the medial glenohumeral ligament, and a rupture of the subscapularis tendon were identified intraoperatively. Transposition of the biceps muscle tendon was performed. However, at 7 days, there was evidence of right shoulder reluxation on radiographs. The second surgery was performed with two $2mm{\times}6mm$ cortical bone anchors and a $4mm{\times}6mm$ cancellous bone anchor placed in the cortical bone of the distal scapula and the cancellous bone of the proximal humerus respectively. Two scapular bone anchors were then connected with a humeral bone anchor using heavy nylon suture to minimize shoulder abduction range of motion. On radiographs right after surgery and 6 weeks after surgery, the affected limb revealed no evidence of medial shoulder luxation. At 6 months, no evidence of lameness was noted on the right thoracic limb.

Analytical Study on the Shear Behavior of Prestressed Concrete Deep Beams (프리스트레스트 콘크리트 깊은 보의 전단거동에 관한 해석적 연구)

  • Kim, Tae-Hoon;Kim, Young-Jin;Shin, Hyun-Mock
    • Journal of the Korea Concrete Institute
    • /
    • 제22권4호
    • /
    • pp.511-517
    • /
    • 2010
  • The purpose of this study is to investigate the shear behavior of prestressed concrete deep beams and to provide the data for development of improved design criteria. The accuracy and objectivity of the assessment process may be enhanced by the use of sophisticated nonlinear finite element analysis program. Hence, in this study, the computer program, named RCAHEST (reinforced concrete analysis in higher evaluation system technology), was used. Material nonlinearity is taken into account by comprising tensile, compressive and shear models of cracked concrete and a model of reinforcing steel. A bonded or unbonded tendon element based on the finite element method, that can represent the interaction between tendon and concrete of prestressed concrete member, is used. The proposed numerical method for the shear behavior of prestressed concrete deep beams is verified by comparing the analytical results with test data by others.

Mesenchymal stem cells and osteogenesis

  • Jung, Cho-Rok;Kiran, Kondabagil R.;Kwon, Byoung S.
    • IMMUNE NETWORK
    • /
    • 제1권3호
    • /
    • pp.179-186
    • /
    • 2001
  • Bone marrow stroma is a complex tissue encompassing a number of cell types and supports hematopiesis, differentiation of erythreid, nyel and lymphoid lineages, and also maintains undifferentiated hematopoietic stem cells. Marrow-derived stem cells were composed of two populations, namely, hematopoietic stem cells that can differentiate into blood elements and mesenchymal stem cells that can give rise to connective tissues such as bone, cartilage, muscle, tendon, adipose and stroma. Differentiation requires environmental factors and unique intracellular signaling. For example, $TGF-{\beta}$ or BMP2 induces osteoblastic differentiation of mesenchymal stem are very exciting. However, the intrinsic controls involved in differentiation of stem cells are yet to be understood properly in order to exploit the same. This review presents an overview of the recent developments made in mesenchymal stem cell research with respect to osteogenesis.

  • PDF

Estimation of Friction Coefficients Based on Field Data (실측값에 근거한 마찰계수의 추정)

  • Jeon, Se Jin;Park, Jong Chil;Park, In Kyo;Shim, Byul
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • 제29권5A호
    • /
    • pp.487-494
    • /
    • 2009
  • Friction coefficients of the prestressing tendon are the basic information required to control the prestressing force introduced to PSC structure during jacking. However, the friction coefficients show considerable differences depending on the specifications, causing much confusion to designers. In this study, the ranges of the friction coefficients presented in domestic and foreign specifications are compared together to clarify the differences. Then, a procedure is proposed that can be used to estimate the wobble and curvature friction coefficients from field data such as elongation and prestressing force and from theory related to the friction. The procedure is applied to various tendon profiles of several PSC bridges constructed by ILM, FCM and MSS. The resulting values are compared with those presented in some specifications and assumed in jacking and a reasonable range of the friction coefficient is discussed. Lift-off tests are also performed in some bridges to further verify the results. The resulting wobble friction coefficients are not as small as those presented in AASHTO specifications but range from the lower limit to mid point of domestic specifications, while the curvature friction coefficients approach or slightly exceed the upper limit.

Transverse Stress of Slabs due tp Longitudinal Prestressing in Prestressed Concrete Box Girders (프리스트레스트 콘크리트 박스 거더의 종방향 프리스트레싱에 의한 슬래브의 횡방향 응력)

  • Yang, In-Hwan
    • Journal of the Korea Concrete Institute
    • /
    • 제15권5호
    • /
    • pp.679-688
    • /
    • 2003
  • For box girders in which the longitudinal tendon is profiled in the inclined webs, longitudinal prestressing force will induce transverse effects as well as longitudinal ones. In this paper, the method to estimate transverse effects induced by longitudinal prestressing is proposed. The concept of transverse equivalent loading which is calculated through longitudinal prestressing analysis is developed. The transverse stress in slabs of box girders due to longitudinal prestressing are investigated. The comparison of numerical results of the proposed method and those of folded plate method represents that the method is reasonable. Numerical analyses are carried out depending on the parameters such as web inclination and ratio of girder length to tendon eccentricity. Analysis results show that when only prestressing are considered the magnitude of transverse stress in slabs of box girder is not so large. However, if the other stresses due to dead and live load et al. are superposed on these stresses, it may be that the longitudinal prestressing effects are significant.