• 제목/요약/키워드: required pressure

검색결과 2,296건 처리시간 0.032초

An experimental study on the hydraulic fracturing of radial horizontal wells

  • Yan, Chuanliang;Ren, Xu;Cheng, Yuanfang;Zhao, Kai;Deng, Fucheng;Liang, Qimin;Zhang, Jincheng;Li, Yang;Li, Qingchao
    • Geomechanics and Engineering
    • /
    • 제17권6호
    • /
    • pp.535-541
    • /
    • 2019
  • Combining the radial well drilling and hydraulic fracturing technique, the production capacity of the reservoirs with low-permeability can be improved effectively. Due to the existence of radial holes, the stress around the well is redistributed, and the initiation and propagation of hydraulic fractures are different with those in traditional hydraulic fracturing. Therefore, it is necessary to study the influences of radial horizontal wells on hydraulic fracturing. The laboratory experiment was conducted to simulate the hydraulic fracturing on the physical model with radial holes. The experimental results showed that, compared with the borehole without radial holes, the sample with radial hole in the direction of maximum horizontal stress was fractured with significantly lower pressure. As the angle between direction of the horizontal hole and the maximum horizontal stress increased, the breakdown pressure grew. While when the radial hole was drilled towards the direction of the minimum horizontal stress, the breakdown pressure increased to that needed in the borehole without radial holes. When the angle between the radial hole and the maximum horizontal stress increase, the pressure required to propagate the fractures grew apparently, and the fracture become complex. Meanwhile, the deeper the radial hole drilled, the less the pressure was needed for fracturing.

CFD를 활용한 태양열 공기가열기 내 사각저항체 설치 조건에 따른 열전달 및 압력강하에 관한 연구 (Research on the Heat Transfer and Pressure Drop by Installation Conditions of Rectangular Obstacle in a Solar Air Heater Based on CFD)

  • 최휘웅;김영복;손창효;윤정인;최광환
    • 한국태양에너지학회 논문집
    • /
    • 제39권1호
    • /
    • pp.77-89
    • /
    • 2019
  • The solar air heater has various performances according to an obstacle installed in the air duct. Many studies on thermal performance have been conducted. But many of these studies were using a kind of rib type obstacle attached at the bottom of absorbing plate, but they are so hard to be manufactured. In this study, characteristics of the heat transfer and pressure drop in the solar air heater with various horizontal rectangular obstacles was investigated by CFD (Computational Fluid Dynamics) analysis. As a result, the heat transfer performance was improved from 1.2 to 3.32 times depending on installation conditions of rectangular obstacle. The pressure drop, however, also increased with increment of heat transfer performance from 2.8 to 180 times only by changing installation conditions of rectangular obstacle. Thus, the performance factor presenting the thermal performance enhancement on the same pressure drop was also confirmed. As a result, the highest value of 0.828 as better performance factor was obtained at the lower height of rectangular obstacle and this value has started to decrease with increment of heat transfer performance. In the end, it could be confirmed that the pressure drop was carried higher than the quantity of improvement of the heat transfer performance when the heat transfer performance was increased by change of installation conditions of rectangular obstacle. Both heat transfer enhancement and pressure drop to be required for system need to be considered before the rectangular obstacles are applied to the solar air heater.

유입 공기의 배출 성능 개선방안에 관한 연구 (A Study on the Performance Improvement Plan of Inflowing Air Emission)

  • 이혜영
    • 한국재난정보학회 논문집
    • /
    • 제18권2호
    • /
    • pp.241-251
    • /
    • 2022
  • 연구목적: 고층 건물 화재시 제연구역이 효과적으로 보호되지 않으면 수직피난경로에 연기나 화염이 유입되어 대피가 어려워진다. 국가화재안전기준에서는 제연구역에 차압 및 방연풍속을 공급하여 능동적으로 연기 유입을 억제하고, 제연구역으로부터 옥내로 유입되는 공기는 옥외로 배출되도록 하고 있다. 본 연구는 유입 공기의 배출로 인한 문제점을 확인하고 성능개선 방안에 대하여 알아보고자 하였다. 연구방법: CONTAM 프로그램을 사용하여 기본조건과 변경조건으로 시뮬레이션을 수행하였다. 연구결과: 밀폐된 복도에서 유입 공기가 배출되면 제연구역에서 과압이 발생하여 개방력을 초과하였고 유입공기가 배출되지 않는 층 에서는 방연풍속이 미달하였다. 결론: "차압 배출댐퍼" 적용, 배출댐퍼 2개층 동시 개방, 복도와 옥외 사이 자동식 창문 설치로 유입공기의 배출 성능이 개선되었다.

연속탈진형 충격기류식 여과집진장치의 여과포 유효탈진거리 예측 (A Study on Prediction of On-line Type Pulse Air Jet Bag Filter Effective Pulsing Distance)

  • 손정삼;서정민;박정호
    • 한국환경과학회지
    • /
    • 제32권8호
    • /
    • pp.555-561
    • /
    • 2023
  • A study is to predict the effective pulsing distance following to the pulsing pressure, nozzle diameter, filtration velocity using numercial analysis techniques and use it as an efficient operation condition and economic data for on-line type pulse air jet bag filter. Filtration area 6 m2 condition, calculate filter resistance coefficient for simulation through the primary experiments using coke dust. For CFD simulation, analysis pulsing characteristics about nozzle diameter, filtration velocity and pulsing pressure. The maximum pulsing length of on-line type pulse air jet bag filter, in 10mm nozzle, filtration velocity 1.5m/min and pulsing pressure 5 bar conditions, is 2,285 mm, maximum length is 76.2% of the total filter bag, which is sufficient to pulsing. In 12mm nozzle, pulsing pressure 5 bar and filtration area 1.22 m2 conditions, the maximum pulsing length of on-line type pulse air jet bag filter is 1,744~2,952 mm, and the maximum length is 2,952 mm indicates pulsing air can be reached to the bottom of filter bag. When the nozzle diameter is increased 8mm to 10mm, maximum pulsing length is extended 40~47%, and increased 10mm to 12 mm, maximum pulsing length is extended 10~17%. For effective pulsing, over the 5bar of pulsing pressure and larger than 10 mm of nozzle diameter are required.

복열테이퍼 롤러베어링 지지특성에 따른 오버헝 회전축 시스템의 동적 거동 예측 및 접촉부 압력 해석 (Prediction of the Dynamic behavior and Contact Pressure of Overhung Rotor Systems According to the Support Characteristics of Double-row Tapered Roller Bearings)

  • 김태우;서준호;김민수;유용훈
    • Tribology and Lubricants
    • /
    • 제39권4호
    • /
    • pp.154-166
    • /
    • 2023
  • This study establishes a numerical analysis model of the finite element overhung rotor supported by a DTRB and describes the stiffness properties of the DTRB. The vibration characteristics and contact pressure of the RBR system are predicted according to the DTRB support characteristics such as the initial axial compression and roller profile. The stiffness of the DTRB significantly varies depending on the initial axial compression and external load owing to the occurrence of rollers under the no-load condition and increase in the Hertz contact force. The increase in the initial axial compression increases the rigidity of the DTRB, thereby reducing the displacement of the RBR system and simultaneously increasing the natural frequency. However, above a certain initial axial compression, the effect becomes insignificant, and an excessive increase in the initial axial compression increases the contact pressure. The roller crowning radius, which gives a curvature in the longitudinal direction of the roller, decreases the displacement of the RBR system and increases the natural frequency as the value increases. However, an increase in the crowning radius increases the edge stress, causing a negative effect in terms of the contact pressure. These results show that the DTRB support characteristics required for reducing the vibration and contact pressure of the RBR system supported by the DTRB can be designed.

HCNG 충전 시스템 공정모사 (Process Simulation of HCNG Refueling System)

  • 김상민;한정옥;이영철;이중성;김용철;채정민;홍성호
    • 한국가스학회지
    • /
    • 제17권5호
    • /
    • pp.1-7
    • /
    • 2013
  • 수소와 압축천연가스가 30 : 70비율로 혼합되는 HCNG 공급 시스템의 공정모사를 수행하였다. 수소 생산은 천연가스로부터 수증기 개질 공정을 이용하는 방법이며, 수증기 개질반응기 운전조건으로 SCR은 증가할수록 천연가스의 전환율은 증가하지만 SCR이 3이상부터는 큰 차이가 없었고, GHSV는 증가할수록 연료처리량이 증가하지만 전환율은 감소하여 $1700h^{-1}$일 때 전환율 및 연료처리량이 최적상태가 되었다. CNG는 저압 천연가스가로부터 압축되어 공급되는 시스템이다. 혼합용 수소와 천연가스는 고압상태에서 HCNG로 혼합된다. 수소와 천연가스는 각각 400 bar와 250 bar의 고압으로 압축된다. 고압압축을 위해 단일압축보다 압축소요동력이 적게 사용되는 다단 압축을 사용하였다. 수소와 천연가스압축에 각각 사용된 압축기들의 압축 총 소요 동력을 최소화하는 중간 설정압력으로 각각 61 bar, 65 bar의 중간압력을 도출하였다.

가압가스 온도에 따른 극저온 추진제탱크 가압가스 요구량 (Required Pressurant Mass for Cryogenic Propellant Tank with Pressurant Temperature Variation)

  • 권오성;김병훈;조인현;고영성
    • 한국항공우주학회지
    • /
    • 제38권12호
    • /
    • pp.1202-1208
    • /
    • 2010
  • 추진제가 배출되는 동안 발사체 추진제탱크의 압력을 유지하기 위해 필요한 가압가스의 요구량을 예측하는 것은 가압시스템의 설계를 위해 반드시 필요하다. 추진제탱크로 유입되는 가압가스의 온도는 가압가스의 요구량에 가장 큰 영향을 미치는 요소로서, 저장탱크의 무게, 열교환기의 크기 등 가압시스템의 개발에 있어 중요한 설계기준이 된다. 이에 극저온 추진제탱크 내에 저장된 추진제를 가압하여 배출하는 실험을 수행하였고, 가압가스 온도 조건에 따른 가압가스 요구량과 얼리지 온도분포를 측정하였다. 그 결과 가압가스의 온도가 높을수록 요구량 자체는 감소하였지만, 이상적인 가압가스 요구량 대비 실제 필요량의 비율은 증가하였다.

야구 타격시 숙련자와 미숙련자의 족저압력 분석 (Plantar Pressure in Skilled and Unskilled Players during Baseball Batting)

  • 문원호;이중숙;김창현;장영민;정진우
    • 한국운동역학회지
    • /
    • 제23권1호
    • /
    • pp.25-35
    • /
    • 2013
  • This study examined 24 right-handed amateur baseball players. Twelve who had played baseball for more than 6 years were grouped as skilled players, while 12 who had played for 1-3 years were the unskilled player group. The swing motion was divided into four event phases: stance, backswing, impact, and follow-through. The mean and maximum plantar pressure, center of pressure, and ground reaction force were measured during each event phase. The mean and standard deviations for each variables were calculated and differences were validated with the independent sample t-test. A p-value <0.05 was considered statistically significant. The results were as follows. 1)The ideal stance is a stable, balanced position with more than 65% of weight on the right foot. There was significant difference in mean left plantar pressure, while the maximal plantar pressure and mean right plantar pressure did not differ significant. 2)The effective backswing of a skilled player is comprised a rightward shift in weight to build maximum energy. More than 90% of the weight was on the right foot. There was a significant difference in the mean left plantar pressure, while the maximal plantar pressure and mean right plantar pressure did not differ significantly. 3) For an effective impact, a rapid shift in weight to the left foot is essential, so that a power hit is obtained. Significant difference in the mean and maximum plantar pressures of both feet were observed. 4)Follow-through requires wight balance, more on the right than the left, without leaning leftward. There was no significant difference in the mean or maximum plantar pressure. 5)The center of plantar pressure should move from the center of the foot to the toe. 6)The analyses of the ground reaction force suggest that a good swing involves a gradual shift in weight to the right side and a rapid leftward shift at impact. Good balance, with the center of gravity on the right side at follow-through, is also required.

임플랜트 식립부위 형성시 골조직의 온도변화에 관한 연구 (A STUDY ON THE TEMPERATURE CHANGES OF BONE TISSUES DURING IMPLANT SITE PREPARATION)

  • 김평일;김영수;장경수;김창회
    • 대한치과보철학회지
    • /
    • 제40권1호
    • /
    • pp.1-17
    • /
    • 2002
  • The purpose of this study is to examine the possibility of thermal injury to bone tissues during an implant site preparation under the same condition as a typical clinical practice of $Br{\aa}nemark$ implant system. All the burs for $Br{\aa}nemark$ implant system were studied except the round bur The experiments involved 880 drilling cases : 50 cases for each of the 5 steps of NP, 5 steps of RP, and 7 steps of WP, all including srew tap, and 30 cases of 2mm twist drill. For precision drilling, a precision handpiece restraining system was developed (Eungyong Machinery Co., Korea). The system kept the drill parallel to the drilling path and allowed horizontal adjustment of the drill with as little as $1{\mu}m$ increment. The thermocouple insertion hole. that is 0.9mm in diameter and 8mm in depth, was prepared 0.2mm away from the tapping bur the last drilling step. The temperatures due to countersink, pilot drill, and other drills were measured at the surface of the bone, at the depths of 4mm and 8mm respectively. Countersink drilling temperature was measured by attaching the tip of a thermocouple at the rim of the countersink. To assure temperature measurement at the desired depths, 'bent-thermocouples' with their tips of 4 and 8mm bent at $120^{\circ}$ were used. The profiles of temperature variation were recorded continuously at one second interval using a thermometer with memory function (Fluke Co. U.S.A.) and 0.7mm thermocouples (Omega Co., U.S.A.). To simulate typical clinical conditions, 35mm square samples of bovine scapular bone were utilized. The samples were approximately 20mm thick with the cortical thickness on the drilling side ranging from 1 to 2mm. A sample was placed in a container of saline solution so that its lower half is submerged into the solution and the upper half exposed to the room air, which averaged $24.9^{\circ}C$. The temperature of the saline solution was maintained at $36.5^{\circ}C$ using an electric heater (J. O Tech Co., Korea). This experimental condition was similar to that of a patient s opened mouth. The study revealed that a 2mm twist drill required greatest attention. As a guide drill, a twist drill is required to bore through a 'virgin bone,' rather than merely enlarging an already drilled hole as is the case with other drills. This typically generates greater amount of heat. Furthermore, one tends to apply a greater pressure to overcome drilling difficulty, thus producing even greater amount heat. 150 experiments were conducted for 2mm twist drill. For 140 cases, drill pressure of 750g was sufficient, and 10 cases required additional 500 or 100g of drilling pressure. In case of the former. 3 of the 140 cases produced the temperature greater than $47^{\circ}C$, the threshold temperature of degeneration of bone tissue (1983. Eriksson et al.) which is also the reference temperature in this study. In each of the 10 cases requiring extra pressure, the temperature exceeded the reference temperature. More significantly, a surge of heat was observed in each of these cases This observations led to addtional 20 drilling experiments on dense bones. For 10 of these cases, the pressure of 1,250g was applied. For the other 10, 1.750g were applied. In each of these cases, it was also observed that the temperature rose abruptly far above the thresh old temperature of $47^{\circ}C$, sometimes even to 70 or $80^{\circ}C$. It was also observed that the increased drilling pressure influenced the shortening of drilling time more than the rise of drilling temperature. This suggests the desirability of clinically reconsidering application of extra pressures to prevent possible injury to bone tissues. An analysis of these two extra pressure groups of 1,250g and 1,750g revealed that the t-statistics for reduced amount of drilling time due to extra pressure and increased peak temperature due to the same were 10.80 and 2.08 respectively suggesting that drilling time was more influenced than temperature. All the subsequent drillings after the drilling with a 2mm twist drill did not produce excessive heat, i.e. the heat generation is at the same or below the body temperature level. Some of screw tap, pilot, and countersink showed negative correlation coefficients between the generated heat and the drilling time. indicating the more the drilling time, the lower the temperature. The study also revealed that the drilling time was increased as a function of frequency of the use of the drill. Under the drilling pressure of 750g, it was revealed that the drilling time for an old twist drill that has already drilled 40 times was 4.5 times longer than a new drill The measurement was taken for the first 10 drillings of a new drill and 10 drillings of an old drill that has already been used for 40 drillings. 'Test Statistics' of small samples t-test was 3.49, confirming that the used twist drills require longer drilling time than new ones. On the other hand, it was revealed that there was no significant difference in drilling temperature between the new drill and the old twist drill. Finally, the following conclusions were reached from this study : 1 Used drilling bur causes almost no change in drilling temperature but increase in drilling time through 50 drillings under the manufacturer-recommended cooling conditions and the drilling pressure of 750g. 2. The heat that is generated through drilling mattered only in the case of 2mm twist drills, the first drill to be used in bone drilling process for all the other drills there is no significant problem. 3. If the drilling pressure is increased when a 2mm twist drill reaches a dense bone, the temperature rises abruptly even under the manufacturer-recommended cooling conditions. 4. Drilling heat was the highest at the final moment of the drilling process.

측정도구와 방법에 따른 간접혈압측정치의 비교연구 (Comparative Study About The Indirect Blood Pressure (measured by different Instruments and Methods))

  • 서길희
    • 기본간호학회지
    • /
    • 제1권1호
    • /
    • pp.51-68
    • /
    • 1994
  • One aim of this study was to find out the difference of indirect blood pressure between the types of instruments. The difference of indirect blood pressure was measured with mercury sphygomomanometer and electronic blood pressuremeter. Another was to determine the difference of indirect blood pressure according to width of cuff and site of cuff. Indirect blood pressures were measured with the diaphragmatic side of sphygomomanometer. The subjects were 40 female volunteers, whose arm circumferences were from 22 to 34cm. The data were analyzed by SPSS-PC program and pared t-test was used. The results are summarized as follows ; 1. Mercury sphygomomanometer systolic pressure was higher(average 2.20mmhg) than electronic blood pressuremeter. It was statistically significant(p=0.026). 2. The value of Mercury sphygomomanometer diastolic pressure was lower(2.00mmhg) than electronic's. It was statistically significant(p=0.03) 3. In the mercury sphygomomanometer systolic pressure, the value of standard cuff($12{\times}23cm$) was higher(2.40mmhg) than large one's($14{\times}45cm$). It was statistically significant(p=0.007). 4. In diastolic pressure(K4), the value of standard cuff was higher(0.65mmhg) than large cuff's. It was not statistically significant(p=0.481). In K5, the value of standard cuff($12{\times}23cm$) was higher(0.55mmhg) than large cuff's. It was not statistically significant(p=0.541). 5. Difference according to site of showed that the values of systolic pressure over elbow joint were higher(20.00mmhg, 26.45mmhg) than ones at site of elbow joint. It was significant statistically(p=0.000) and clinically. 6. The values of diastolic pressure(K4) over elbow joint were higher(17.10mmhg, 21.60mmhg) than ones at site of elbow joint. It was significant statistically (p=0.000) and clinically. The values of K5 over elbow joint were higher(17.25mmhg, 22.15mmhg) than ones at site of elbow joint. It was significant statistically(p=0.000) and clinically. I think similar studies about indirect blood pressure according to diseases and positions are necessary. In addition, similar studies, are required about accuracy of method electronic blood pressuremeter according to site of mesurement.

  • PDF