• Title/Summary/Keyword: repeated measurements.

Search Result 441, Processing Time 0.027 seconds

Measurement of facial soft tissues thickness using 3D computed tomographic images (3차원 전산화단층찰영 영상을 이용한 얼굴 연조직 두께 계측)

  • Jeong Ho-Gul;Kim Kee-Deog;Han Seung-Ho;Shin Dong-Won;Hu Kyung-Seok;Lee Jae-Bum;Park Hyok;Park Chang-Seo
    • Imaging Science in Dentistry
    • /
    • v.36 no.1
    • /
    • pp.49-54
    • /
    • 2006
  • Purpose : To evaluate accuracy and reliability of program to measure facial soft tissue thickness using 3D computed tomographic images by comparing with direct measurement. Materials and Methods : One cadaver was scanned with a Helical CT with 3 mm slice thickness and 3 mm/sec table speed. The acquired data was reconstructed with 1.5 mm reconstruction interval and the images were transferred to a personal computer. The facial soft tissue thickness were measured using a program developed newly in 3D image. For direct measurement, the cadaver was cut with a bone cutter and then a ruler was placed above the cut side. The procedure was followed by taking pictures of the facial soft tissues with a high-resolution digital camera. Then the measurements were done in the photographic images and repeated for ten times. A repeated measure analysis of variance was adopted to compare and analyze the measurements resulting from the two different methods. Comparison according to the areas was analyzed by Mann-Whitney test. Results : There were no statistically significant differences between the direct measurements and those using the 3D images (p>0.05). There were statistical differences in the measurements on 17 points but all the points except 2 points showed a mean difference of 0.5 mm or less. Conclusion : The developed software program to measure the facial soft tissue thickness using 3D images was so accurate that it allows to measure facial soft tissues thickness more easily in forensic science and anthropology.

  • PDF

Repeated Records Animal Model to Estimate Genetic Parameters of Ultrasound Measurement Traits in Hanwoo Cows (반복모형을 이용한 한우 초음파 측정형질의 유전모수추정)

  • Park, Cheol-Hyeon;Koo, Yang-Mo;Kim, Byung-Woo;Sun, Du-Won;Kim, Jung-Il;Song, Chi-Eun;Lee, Ki-Hwan;Lee, Jae-Youn;Jeoung, Yeoung-Ho;Lee, Jung-Gyu
    • Journal of Animal Science and Technology
    • /
    • v.54 no.2
    • /
    • pp.71-75
    • /
    • 2012
  • The present study data were obtained from 36,894 cows in Korea Animal Improvement Association from 2001 to 2009 which was subjected for ultrasound measurements (eye muscle area, back-fat thickness, marbling score) and descent. Repeated record models were carried out using 7,913 of 36,894 of total animal traits. The ultrasound measured traits and performance test data were used to study the chest girth, body condition score, eye muscle area, back-fat thickness and marbling score with genetic correlation and parameters for the ultrasound measured traits using REMLF90 program. Genetic correlation of eye muscle area with back-fat thickness, marbling score and back-fat thickness with marbling score were noticed in repeated records animal model as 0.69, 0.54, and 0.59, whereas in multiple trait animal model method were 0.07, 0.66, and 0.39, respectively. Repeated records of animal models were used as positive correlation of traits. Multiple trait animal models were used as negative correlation of eye muscle area with marbling score. The analysis on repeat records of animal models using ultrasound measurements about Korean cattle showed positive effects for each traits. In comparison differences between the repeat records of animal models and multiple trait animal models was found with higher traits of her, the heritability and repeatability was found higher in repeat records animal models. In light of these assessments, carcass traits by ultrasound measurements are expected to help and improve an accurate analysis of each trait and if the research analysis using repeat records of animal models continue when we estimate genetic ability of these traits.

Accuracy of spring-style and friction-style mechanical implant torque wrench (스프링형과 마찰형 기계식 임플란트 토크 렌치의 정확도에 관한 연구)

  • Cha, Dong-Hee;Oh, Sang-Chun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.1
    • /
    • pp.8-13
    • /
    • 2016
  • Purpose: The aim of this study was to compare the accuracy of two different styles of mechanical implant torque wrenches before and after sterilization and repeated use. Materials and methods: Thirty new spring-style and friction-style mechanical implant torque wrenches from five different manufacturers were selected as subjects of study and assessed in terms of accuracy. Three manufacturers produced, spring-style (Dio, Neobiotech, Osstem) torque wrenches, and other three manufactures produced friction-style (Dentium, Osstem, Shinhung) torque wrenches. The procedure of target torque measurement was performed 10 times for each device and a digital torque gauge (MGT-12, Mark-10 Corp, USA) was used to record the measurements. All torque wrenches were used repeatedly for 20 times and then sterilized. This whole procedure was repeated 100 times and all torque wrenches were retested. The collected data was analyzed using a SPSS Statistics Analysis program to evaluate the accuracy of the torque wrenches and Mann-Whitney-U test was used for a comparative analysis. Results: After sterilization and repeated use procedure, results did not show any significant difference between error values in the spring-style torque wrench group. However, the results demonstrated an increase in error values within the friction-style torque wrench group (P<.05). Conclusion: There was no difference between the accuracy of new spring-style torque wrenches before and after 100 cycles of sterilization and repeated use (P>.05). There was significant difference between the accuracy of new friction-style torque wrenches before and after 100 cycles of sterilization and repeated use (P<.05). Within the limitation of this study, spring-style torque wrenches were more accurate than friction-style torque wrenches in delivering target torque values.

Comparison of measurements from digital cephalometric radiographs and 3D MDCT-synthetized cephalometric radiographs and the effect of head position (디지털 측방두부규격방사선사진과 MDCT의 3차원 재구성 영상을 이용한 합성측방두부규격방사선사진의 계측치 비교 및 머리 위치가 미치는 효과)

  • Kim, Mi-Ja;Choi, Bo-Ram;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-SUk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.39 no.3
    • /
    • pp.133-147
    • /
    • 2009
  • Purpose : To investigate the reproducibilities and compare the measurements in digital and MDCT-synthesized cephalometric radiograph, and to investigate the effect of head position on the measurement during imaging with MDCT. Materials and Methods : Twenty-two dry skulls (combined with mandible) were used in this study. Conventional digital cephalometric radiograph was taken in standard position, and MDCT was taken in standard position and two rotated position ($10^{\circ}$ left rotation and $10^{\circ}$ right tilting). MDCT data were imported in $OnDemand^{(R)}$ and lateral cephalometric radiograph were synthesized from 3D virtual models. Two types of rotated MDCT data were synthesized with default mode and with corrected mode using both ear rods. For all six images, sixteen angular and eleven linear measurements were made in V-$Ceph^{(R)}$ three times. Reproducibility of measurements was assessed using repeated measures ANOV A and ICC. Linear and angular measurements were compared between digital and five MDCT-synthesized images by Student t-test. Results : All measurements in six types of cephalometric radiograph were not statistically different under ICC examination. Measurements were not different between digital and MDCT-synthesized images (P>.05). Measurements in MDCT-synthesized image in $10^{\circ}$ left rotation or $10^{\circ}$ right tilting position showed possibility of difference from digital image in some measurements, and possibility of improvement via realignment of head position using both ear rods. Conclusion : MDCT-synthesized cephalometric radiograph can substitute conventional cephalometric radiograph. The error on head position during imaging with MDCT have possibility that can produce measurement errors with MDCT-synthesized image, and these position error can be corrected by realignment of the head position using both ear rods.

  • PDF

Effects of Lavender Aromatherapy on Insomnia and Depression in Women College Students (라벤더 향요법이 여대생의 불면증과 우울에 미치는 영향)

  • Lee, Inn-Sook;Lee, Gyung-Joo
    • Journal of Korean Academy of Nursing
    • /
    • v.36 no.1
    • /
    • pp.136-143
    • /
    • 2006
  • Purpose: The purpose of this study was to explore the effects of the lavender fragrance on sleep and depression in women college students, Method: Forty-two women college students who complained of insomnia were studied during a four-weekprotocol( control treatment week, $60\%$ lavender fragrance treatment week, washout week, $100\%$ lavender fragrance treatment week), All subjects were in the department of nursing in 'K' college and the study was a single blind repeated measurements experiment For the duration of the study, weekly evaluations of sleep, patterns of sleep disturbance, severity of insomnia scale, self satisfaction with sleep, and severity of depression were performed. Result: Among sleep variables, length of time taken to fall asleep, severity of insomnia, and self satisfaction with sleep were improved for the $60\%$(p=.000, p=.000, p=.000) and $100\%$(p=.000, p=.000, p=.000) week while the severity of depression was improved only for the $100\%$(p=.002)week. Conclusion: According to the study results, it can be concluded that the lavender fragrance had a beneficial effect on insomnia and depression in women college students. Repeated studies are needed to confirm effective proportions of lavender oil and carrier oil for insomnia and depression.

Effects of Microcurrent Delayed Onset Muscle Soreness on Creatine Kinase (지연성 근육통에 대한 미세전류자극치료가 통증과 CK에 미치는 영향)

  • Cho, Namjeong;Song, SeongHyeok
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.2 no.3
    • /
    • pp.31-37
    • /
    • 2014
  • Purpose : Delayed onset muscle soreness(DOMS) is a common problem that can interfere with rehabilitation as well as activities of daily living. The purpose of this study was to compare the effect of both trascutaneous electrical nerve stimulation(TENS) Micro current(MC) and only normal Therapy on Delyed Onset Muscle Soreness(DOMS). Method : The Methods ten untrained and male volunteer subjects were randomly assigned to one of two treatment groups: 1) a group that received TENS (60Hz) MC($60{\mu}A$, 3pps) a control group that received no MC treatment. Subjects performed repeated eccentric exercise of the non-dominant forearm flexor muscle with submaximal intensity by the simply designed eccentric exercise devices. Treatments were applied after 24hours and 48hours. Subjects attended on two consecutive days for treatment and measurement of paining(visual analogue scale: VAS) and CK(Creatine kinase) on a daily basis. Measurements were taken after treatment. Results : 1) There were no significant differences between TENS and MENS by two-way repeated ANOVA. The Results that t-test for VAS revealed significant differences within TENS group. 3) The t-test for VAS, and Creatine Kinase of time revealed significant differences within MC group. Conclusion : These findings suggest that both TENS and MENS had effect on DOMS.

Improvement of the repeatability and reproducibility of the meridian impedance measurement system MIR-2 (경락노선상 임피던스 측정기(MIR-2)의 측정신뢰도 개선방안 연구)

  • Yin, Chang-Shik;Lee, Hye-Jung;Kim, Jong-Yeol;Lee, Woo-Cheol
    • Korean Journal of Acupuncture
    • /
    • v.24 no.4
    • /
    • pp.55-67
    • /
    • 2007
  • Objectives : The repeatability and reproducibility of MIR-2, a newly developed impedance measurement device (four electrode method) on skin are of the meridian system, is evaluated and a method to improve the reliability is discussed. Methods : Multiple gage R&R studies were conducted for the impedance measurements over bilateral KI3 acupoint in ten participants by three assessors using MIR-2 device. Gage R&R studies were repeated after controlling the acupoint locating method or one value correction by replacing one assessor's outlying value with an average of the other assessors' values to explore any feasibility of improvement of measurement reliability. Results : Controlling acupoint locating method and replacing one value with an average of other assessors' value led to improved variation metrics in a gage R&R study. Conclusions : Measurement reliability can be improved by controlling measurement procedures or by using repeated measurement method, which will facilitate development of clinically applicable measurement device with reliability.

  • PDF

Low-temperature Reduction of N2O by H2 over Pt/SiO2 Catalysts (Pt/SiO2 촉매상에서 H2에 의한 저온 N2O 제거반응)

  • Kim, Moon Hyeon;Kim, Dae Hwan
    • Journal of Environmental Science International
    • /
    • v.22 no.1
    • /
    • pp.73-81
    • /
    • 2013
  • The present work has been devoted to the catalytic reduction of $N_2O$ by $H_2$ with $Pt/SiO_2$ catalysts at very low temperatures, such as $110^{\circ}C$, and their nanoparticle sizes have been determined by using $H_2-N_2O$ titration, X-ray diffraction(XRD) and high-resolution transmission electron microscopy(HRTEM) measurements. A sample of 1.72% $Pt/SiO_2$, which had been prepared by an ion exchange method, consisted of almost atomic levels of Pt nanoparticles with 1.16 nm that are very consistent with the HRTEM measurements, while a $Pt/SiO_2$ catalyst possessing the same Pt amount via an incipient wetness technique did 13.5 nm particles as determined by the XRD measurements. These two catalysts showed a noticeable difference in the on-stream $deN_2O$ activity maintenance profiles at $110^{\circ}C$. This discrepancy was associated with the nanoparticle sizes, i.e., the $Pt/SiO_2$ catalyst with the smaller particle size was much more active for the $N_2O$ reduction. When repeated measurements of the $N_2O$ reduction with the 1.16 nm Pt catalyst at $110^{\circ}C$ were allowed, the catalyst deactivation occurred, depending somewhat on regeneration excursions.

Effects of Kinesio Taping Applied on the Ankle Instability to Range of Motion and Balance (발목 불안정성에 키네시오 테이핑적용이 관절가동범위 및 균형에 미치는 영향)

  • Seo, Tae-hwa;Go, Hyun-min;Park, Jong-hang;Kim, Yoon-hwan;Kim, Tae-won;Park, Hyun-sik
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.23 no.1
    • /
    • pp.7-13
    • /
    • 2017
  • Background: To evaluate the effect of Kinesio taping applied on the ankle instability, joint range of motion and balance. Methods: The participants included in this study were male and female, 20~30 ages, who experiencing an ankle sprain or had chronic pain, did not exercise during the intervention, and did not experience severe exercise at least 3 weeks before. A total of twenty-four participants were divided into two groups: Kinesio taping applied group (n=12) and control group (n=12). The experiment was conducted for a three days. Measurements were taken for ankle joint range of motion using goniometer, and measurements were taken for balance using good balance system. Pre-test measurements were conducted on before Kinesio taping apply, and 24 hours after, 48 hours after, 72 hours after measurements were conducted. Statistical analysis was done using a independent samples t-test and repeated measure ANOVA. Results: There were significant differences to the duration of intervention in ankle joint range of motion and balance within the both group. However, there was a significant differences Kinesio taping group when comparing the groups. Conclusions: According to the results of this study, applying Kinesio taping to ankle instability is more effective on ankle joint range of motion and to recover balance.

  • PDF

Three-dimensional morphological evaluation of the hard palate in Korean adults with mild-to-moderate obstructive sleep apnea

  • Yu, Chen;Ahn, Hyo-Won;Kim, Seong-Hun
    • The korean journal of orthodontics
    • /
    • v.48 no.3
    • /
    • pp.133-142
    • /
    • 2018
  • Objective: The purpose of this study was to evaluate differences in three-dimensional (3D) morphology of the hard palate between Korean adults with and without mild-to-moderate obstructive sleep apnea (OSA) using cone-beam computed tomographic (CBCT) data. Methods: The protocol for the two-dimensional (2D) and 3D mathematical modeling was established by analyzing CBCT images of 30 adults with OSA and 30 matched controls without OSA, using MIMICS software. The linear and angular measurements were also determined using this software. The measurements were repeated for 30 palates, by the same operator, to assess reliability. Results: The palates of OSA patients were higher in the posterior part and narrower in the anterior-superior part than those of the control group (p < 0.05). The nasal cavities of patients with OSA were narrower (p < 0.05) than those of controls. The increasing angle of the first molar palatal root is a compensation of the upper dental arch to improve occlusion. However, for most palatal measurements, there were no significant differences between the OSA and control groups (p > 0.05). The results of 2D and 3D mathematical models were consistent for linear and angular measurements, indicating that 2D and 3D mathematical modeling of the palate is a reliable methodology. Conclusions: OSA is a multifactorial disease; the palates of adults with mild-to-moderate OSA do not have specific morphological features distinct from those of healthy controls.