• Title/Summary/Keyword: repeated measurement data

Search Result 222, Processing Time 0.028 seconds

Measurement of facial soft tissues thickness using 3D computed tomographic images (3차원 전산화단층찰영 영상을 이용한 얼굴 연조직 두께 계측)

  • Jeong Ho-Gul;Kim Kee-Deog;Han Seung-Ho;Shin Dong-Won;Hu Kyung-Seok;Lee Jae-Bum;Park Hyok;Park Chang-Seo
    • Imaging Science in Dentistry
    • /
    • v.36 no.1
    • /
    • pp.49-54
    • /
    • 2006
  • Purpose : To evaluate accuracy and reliability of program to measure facial soft tissue thickness using 3D computed tomographic images by comparing with direct measurement. Materials and Methods : One cadaver was scanned with a Helical CT with 3 mm slice thickness and 3 mm/sec table speed. The acquired data was reconstructed with 1.5 mm reconstruction interval and the images were transferred to a personal computer. The facial soft tissue thickness were measured using a program developed newly in 3D image. For direct measurement, the cadaver was cut with a bone cutter and then a ruler was placed above the cut side. The procedure was followed by taking pictures of the facial soft tissues with a high-resolution digital camera. Then the measurements were done in the photographic images and repeated for ten times. A repeated measure analysis of variance was adopted to compare and analyze the measurements resulting from the two different methods. Comparison according to the areas was analyzed by Mann-Whitney test. Results : There were no statistically significant differences between the direct measurements and those using the 3D images (p>0.05). There were statistical differences in the measurements on 17 points but all the points except 2 points showed a mean difference of 0.5 mm or less. Conclusion : The developed software program to measure the facial soft tissue thickness using 3D images was so accurate that it allows to measure facial soft tissues thickness more easily in forensic science and anthropology.

  • PDF

A Comparison of Estimation Approaches of Structural Equation Model with Higher-Order Factors Using Partial Least Squares (PLS를 활용한 고차요인구조 추정방법의 비교)

  • Son, Ki-Hyuk;Chun, Young-Ho;Ok, Chang-Soo
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.36 no.4
    • /
    • pp.64-70
    • /
    • 2013
  • Estimation approaches for casual relation model with high-order factors have strict restrictions or limits. In the case of ML (Maximum Likelihood), a strong assumption which data must show a normal distribution is required and factors of exponentiation is impossible due to the uncertainty of factors. To overcome this limitation many PLS (Partial Least Squares) approaches are introduced to estimate the structural equation model including high-order factors. However, it is possible to yield biased estimates if there are some differences in the number of measurement variables connected to each latent variable. In addition, any approach does not exist to deal with general cases not having any measurement variable of high-order factors. This study compare several approaches including the repeated measures approach which are used to estimate the casual relation model including high-order factors by using PLS (Partial Least Squares), and suggest the best estimation approach. In other words, the study proposes the best approach through the research on the existing studies related to the casual relation model including high-order factors by using PLS and approach comparison using a virtual model.

Nausea/Vomiting and Anxiety of Hospitalized Cancer Patients Receiving Chemotherapy (항암화학요법을 받는 입원환자의 오심·구토 및 불안 정도에 관한 조사연구)

  • Choi, Ja Yun;So, Hyang-Sook;Cho, In Sook
    • Korean Journal of Adult Nursing
    • /
    • v.16 no.2
    • /
    • pp.211-221
    • /
    • 2004
  • Purpose: The purpose of this study was to describe the pattern of changes on the score of nausea/vomiting and anxiety during one cycle of chemotherapy. Method: A total of 53 subjects who were admitted to C University Hospital for a period of 3 days and 2 nights for chemotherapy were selected from February to April, 2003. Total scores of nausea/vomiting were measured twice a day 3 days for a total of 6 measurements. Anxiety, anorexia, and fatigue were also measured at the first and last measurement points. Data were analyzed by one-way repeated measures, ANOVA, t-test, paired t-test, & Pearson's correlation. Result: The score of nausea/vomiting increased over time except for the 4th measurement point but no changes were significant over time. There were the significant differences between 1st and 2nd, and 2nd and 3rd nausea/vomiting score at p < 0.05. The scores of anxiety, anorexia, and fatigue between the first and 6th points were significantly different(t=-5.69, p=.001; t=6.25, p=.0001; t=3.65, p=.0007). Conclusion: Further studies are needed to identify the relationship between anxiety, and anticipatory and acute nausea/vomiting respectively.

  • PDF

Uncertainty Study of Added Resistance Experiment (부가저항 실험의 불확실성 연구)

  • Park, Dong-Min;Lee, Jaehoon;Kim, Yonghwan
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.51 no.5
    • /
    • pp.396-408
    • /
    • 2014
  • In this study, uncertainty analysis based on ITTC(International Towing Tank Conference) Recommended Procedures is carried out in the towing-tank experiment for motion responses and added resistance. The experiment was conducted for KVLCC2 model in head sea condition. The heave, pitch and added resistance were measured in different wave conditions, and the measurement was repeated up to maximum 15 times in each wave condition in order to observe the uncertainty of measured data. The uncertainty analysis was carried out by adopting the ISO-GUM(International Organization for Standardization, Guide to the Expression of Uncertainty in Measurements) method recommended by ITTC. This paper describes the details about the analysis method, uncertainty and the measured uncertainty for each source. The uncertainty analysis results are summarized as a tabular form. To validate the accuracy of the present measurement, the experimental results are compared with the results of numerical computation and other experiment. From the present uncertainty analysis, the main sources of uncertainty are identified, which can be very useful to improve the accuracy for added resistance experiment.

New Approach of Evaluating Poomsae Performance with Inertial Measurement Unit Sensors (관성센서를 활용한 새로운 품새 경기력 평가 방법 연구)

  • Kim, Young-Kwan
    • Korean Journal of Applied Biomechanics
    • /
    • v.31 no.3
    • /
    • pp.199-204
    • /
    • 2021
  • Objective: The purpose of this study was to present a new idea of methodology to evaluate Poomsae performance using inertial measurement unit (IMU) sensors in terms of signal processing techniques. Method: Ten collegian Taekwondo athletes, consisting of five Poomsae elite athletes (age: 21.4 ± 0.9 years, height: 168.4 ± 11.3 cm, weight: 65.0 ± 10.6 kg, experience: 12 ± 0.7 years) and five breaking demonstration athletes (age: 21.0 ± 0.0 years, height: 168.4 ± 4.7 cm, weight: 63.8 ± 8.2 kg, experience: 13.0 ± 2.1 years), voluntarily participated in this study. They performed three different black belt Poomsae such as Goryeo, Geumgang, and Taebaek Poomsae repeatedly twice. Repeated measured motion data on the wrist and ankle were calculated by the methods of cosine similarity and Euclidean distance. Results: The Poomsse athletes showed superior performance in terms of temporal consistency at Goryeo and Taebaek Poomsae, cosine similarity at Geumgang and Taebaek Poomsae, and Euclidian distance at Geumgang Poomsae. Conclusion: IMU sensor would be a useful tool for monitoring and evaluating within-subject temporal variability of Taekwondo Poomsae motions. As well it distinguished spatiotemporal characteristics among three different Poomsae.

The Effects of Scapular Stabilization Exercise before Rotator Cuff Repair on Pain and ROM of Middle-aged Women (중년여성의 가시위근 봉합술전 어깨뼈 안정화운동이 통증과 ROM향상에 미치는 영향)

  • Kim, Taeyeob;Yoo, Byungkook
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.2 no.1
    • /
    • pp.63-76
    • /
    • 2014
  • Purpose : The purpose of this study was to ascertain the effects of scapular stabilization exercise before rotator cuff surgery on pain and range of motion of middle-aged women. Method : 20 subjects who agreed on this experiment and were diagnosed with rotator cuff rupture participated in this study. Experimental groups were treated while 40 minutes a day, 5 times per week, for 2 weeks before surgery. The effects of scapular stabilization exercise were evaluated on VAS and range of motion. Collected data were analyzed with SPSS for windows ver. 20.0 program. One-way repeated ANOVA was used to examine a significance of each variable by time. Two-way repeated ANOVA was applied to examine a significance of the experimental group against the control group. In all statistical tests, the significance level was set by ${\alpha}=.05$. Result : The results of this study are as follows: 1) In both control and experimental groups, VASs were decreased significantly according to intervention period. There was no significant difference between VASs of two groups. 2) In both control and experimental groups, ROMs of shoulder, flexion, abduction and external rotation were increased significantly according to intervention period. In these three flexibility measurement variables, there were significant differences between ROMs of two groups. Conclusion : In view of all the results in this study, scapular stabilization exercise on before rotator cuff surgery proved to be effective in improving their pain, range of motion after surgery. It will be sufficient data to perform with their own exercise program.

A Study on the Change of Clinical Self-Confidence according to the Number of Clinical Dental Hygiene Practices of Students in the Department of Dental Hygiene - Focusing on scaling practices -

  • Choi, Yong-Keum;Kim, Mi-Sun;Jeong, Su-Ra;Kim, Eun-Jeong
    • Journal of Korean Dental Hygiene Science
    • /
    • v.3 no.2
    • /
    • pp.39-49
    • /
    • 2020
  • The purpose of this study was to provide the basic data needed to plan the effective teaching design of scaling education and to measure the changes in students' confidence in performing scaling according to the number of scaling practices. Scaling education is presented as a core basic hygiene competency of dental hygienists and evaluated as the practical competency of dental hygienists. This study selected 48 third-year students from the department of dental hygiene at S University in Asan, and analyzed data from completed participant surveys. The degree of "confidence in facing the subject in clinical practice," "confidence in applying hand instrument to the subject," and "confidence in applying ultrasonic instruments to the subject" was assessed on a five-point Likert scale. The difference in confidence was analyzed during five practice sessions. Each response was compared using frequency analysis, chi-square test, and repeated measurement ANOVA. Students who complained of a lack of confidence in the 14.6%, 25.0%, and 12.5%, respectively, in face-to-face practice, hand instruments, and ultrasonic instrument application responses. The more the practice was repeated, the more confident students were in all three categories, and the more statistically significant (p<0.001). As the number of scaling practice sessions increased, students' confidence in performing scaling also improved. In particular, the level of self-confidence was higher after the third practice session when compared to the first session. Therefore, it is necessary to design effective courses for teaching scaling practices so that at least three repetitive practice periods can be provided in clinical dental hygiene practices.

Clinical efficacy of Gyeongshingangjeehwan16 according to obeisty related to measurement variables. (신체부위별 측정변인에 따른 경신강지환16의 비만 개선효과 평가)

  • Jung, Yang-Sam;Yoon, Ki-Hyeon;Choi, Seung-Bae;Yoon, Mi-Chung;Shin, Soon-Shik
    • Herbal Formula Science
    • /
    • v.16 no.1
    • /
    • pp.169-183
    • /
    • 2008
  • In this study, we measured body mass index, visceral fat ratio and 6 parts of body, neck circumference, circumference of upper arm, chest circumference, abdomen circumference, hip circumference, and thigh circumference by bioimpedence analysis system, after taking Gyeongshingangjeehwan16 (GGEx16) in five months except the first period before taking GGEx16 on 49 women who are obesity or high-level obesity. In order to examine the significance test for the effect of obesity improvement of GGEx16, we practices repeated measure ANOVA with values of measurement variables in 6 monthly times. As a result of all measurement variables, there were significant difference (P-value=0.001). Therefore, we can say that GGEx16 is effective about obesity improvement. As it dramatically decreased between second measure period and first measure period for all measure variables, we can see that there were the most effect of GGEx16 in the first time after taking GGEx16. It is known that a important measurement variable to have a effect for obesity improvement about two variable which are body mass index and visceral fat ratio is waist circumference through correlation analysis. The result of whether there are differences to effect of obesity improvement for GGEx16 around the climacteric, there were significant difference for the effect of obesity improvement for GGEx16 around the climacteric about all parts of body (P-value=0.001). There were also powerfully difference in effect of obesity improvement for GGEx16 around the climacteric about all parts of body (P-value=0.001). Especially, the climacteric before is more effective than the climacteric after in the aspect of the effect of GGEx16.

  • PDF

Effects of Pilates Exercises on Isokinetic Trunk Strength and Balance in Female Middle School Students with Lumbago (필라테스 운동이 여중생의 요통과 체간 등속성 근력 및 평형성에 미치는 영향)

  • Jung, In;Choi, Seung-Jun
    • PNF and Movement
    • /
    • v.19 no.2
    • /
    • pp.183-193
    • /
    • 2021
  • Purpose: The purpose of this research was to investigate the effects of performing Pilates exercises for eight weeks on the isokinetic trunk strength and balance of female middle school students with lumbago. Methods: Twenty-four female students who met the test requirements were recruited and randomly divided into a control group (CG, n = 16) and a Pilates exercise group (Pilates group; PG, n = 8). The PG performed a Pilates program, which consisted of lumbar muscle strengthening exercises, for 60 minutes three times a week for eight weeks. Data analysis was conducted by two-way repeated ANOVA, and a Bonferroni test was carried out when significant differences appeared. The alpha level was set at 0.05. Results: Following the experimental treatment, the PG showed an increased trunk flexion peak torque of 17% and 13% at angular velocities of 180°/sec and 300°/sec, respectively. The intergroup comparison showed no significant difference at pre-measurement, while the PG increased about 31% (180°/sec) and 15% (300°/sec) higher than the control group at post-measurement. Following the experimental treatment, the PG showed an increased trunk extensor peak torque of approximately 29% and 21% at angular velocities of 180°/sec and 300°/sec, respectively. The intergroup comparison showed no significant difference at pre-measurement, while the PG increased approximately 27% (180°/sec) and 15% (300°/sec) higher than the control group at post-measurement. Both the CG and the PG showed a 20% and 50% decrease in pain index after the experimental treatment, respectively. After the experimental treatment, the PG had about 50% lower pain than the CG. The average error rate of static balance in the PG reduced by 19% from 3.28±0.45 to 2.65±0.36, confirming a significant improvement. Conclusion: Regular Pilates exercise for eight weeks improved the isokinetic trunk muscle strength of female middle school students with lumbago and relieved their pain. Pilates was also shown to be effective in improving balance.

Mass Transfer Characteristics of the Carbon Dioxide-Water Slug Flow in Vertical Small-Bore Tubes (작은 직경의 수직관을 흐르는 이산화탄소-물 슬러그 유동의 물질전달 특성)

  • Lee, Kyung-Jae;Kim, Dong-Seon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.5
    • /
    • pp.401-408
    • /
    • 2012
  • Volumetric mass transfer coefficient was measured with carbon dioxide and deionized water for the gas-liquid cocurrent slug flow in 2, 5 and 8 mm tubes. Measurement was repeated with and without a vertical section in an experimental setup and entrance effect was found greater for smaller tubes. Volumetric mass transfer coefficient in the vertical section was found generally a strong function of gas- and liquid-phase superficial velocities. 5 mm- and 8 mm-tube data are highly consistent each other but not with 2 mm tube.