• Title/Summary/Keyword: repeated error

Search Result 254, Processing Time 0.022 seconds

Precision Measurement of Ultrasonic Power the Milliwatt Range (밀리와트 영역의 초음파 파워 정밀 측정)

  • Jho, Moon-Jae;Hwang, Cheol-Ho;Suh, Sang-Joon;Cha, Il-Whan
    • The Journal of the Acoustical Society of Korea
    • /
    • v.9 no.2
    • /
    • pp.25-33
    • /
    • 1990
  • An ultrasonic power measurement system in milliwatt range was constructed. The ultrasonic power can be determined by measuring the radiation pressure on a target using self-compensating microbalance. Measurement was performed using a perfect reflector and a perfect absorber. In order to check the feasibility of the system, the ultrasonic power for the two targets was measured. Also, the systematic measurement errors and the reproducibility were examined. The relative error between two targets is proved to be within 2%. Also when the ultrasonic power range is larger than 10mW, the standard deviation for repeated measurement becomes smaller than ${\pm}$2%.

  • PDF

Determination of Optimum Threshold for Accuracy of People-counting System Based on Motion Detection

  • Ryu, Hanseul;Song, Junho;Lee, Boram;Lee, Kiyoung
    • Journal of Environmental Health Sciences
    • /
    • v.41 no.5
    • /
    • pp.299-304
    • /
    • 2015
  • Objectives: A people-counting system measures real-time occupancy through motion detection. Accurate people-counting can be used to calculate suitable ventilation demands. This study determined the optimum motion threshold for a people-counting system. Methods: In a closed room with two occupants moving constantly, different thresholds were tested for the accuracy of a people-counting system. The experiments were conducted at 150, 300, 450 and 600 lux. These levels of brightness included the illumination levels of most public indoor areas. The experiments were repeated with three types of clothing coloration. Results: Overall, a threshold of 16 provided the lowest mean error percentage for the people-counting system. Brightness and clothing color did not have a significant impact on the results. Conclusion: A people-counting system could be used with threshold of 16 for most indoor environments.

Feed forward Differential Architecture of Analog Parallel Processing Circuits for Analog PRML Decoder (아날로그 PRML 디코더를 위한 아날로그 병렬처리 회로의 전향 차동 구조)

  • Sah, Maheshwar Pd.;Yang, Chang-Ju;Kim, Hyong-Suk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.8
    • /
    • pp.1489-1496
    • /
    • 2010
  • A feed forward differential architecture of analog PRML decoder is investigated to implement on analog parallel processing circuits. The conventional PRML decoder performs the trellis processing with the implementation of single stage in digital and its repeated use. The analog parallel processing-based PRML comes from the idea that the decoding of PRML is done mainly with the information of the first several number of stages. Shortening the trellis processing stages but implementing it with analog parallel circuits, several benefits including higher speed, no memory requirement and no A/D converter requirement are obtained. Most of the conventional analog parallel processing-based PRML decoders are differential architecture with the feedback of the previous decoded data. The architecture used in this paper is without feedback, where error metric accumulation is allowed to start from all the states of the decoding stage, which enables to be decoded without feedback. The circuit of the proposed architecture is simpler than that of the conventional analog parallel processing structure with the similar decoding performance. Characteristics of the feed forward differential architecture are investigated through various simulation studies.

Reproducibility analysis of surface EMG spike variables during isometric voluntary contraction of the biceps brachii muscle (이두박근의 등척성 자의 수축시 표면근전도 신호에서 검출한 스파이크 변수들의 재현성 분석)

  • Lee, Jin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.6
    • /
    • pp.1246-1254
    • /
    • 2009
  • The reproducibility of initial value and change over time of surface EMG spike variables(MSA, MSF, MSS, MSD) was investigated in the biceps brachii muscle of 11 healthy subjects. Surface EMG signals were recorded during sustained isometric voluntary contractions for 30 seconds at three contraction levels, 20%, 50%, and 80%MVC, respectively. Each contraction was repeated three times in each of three different days for a total of nine contractions and 99 contractions per %MVC level across the eleven subjects. A total of 297 EMG signals across the different trials, days, subjects, and %MVC levels was saved for the subsequent analysis. The degree of reproducibility was investigated using the intraclass correlation coefficient(ICC) and the standard error of the mean(SEM) based upon the analysis of variance(ANOVA), Results for intercept showed higher reproducibility of the spike variables with about 60%-98% ICC than the variable(ARV, MNF) which had been analyzed before in other researches. And results for slope showed poor reproducibility of the spike variables with about 30%-70% ICC and they were comparable with the variables of other researches.

Effects of Premixed Flame on Turbulence Properties in a Pilot Flame Stabilized Jet Burner (파일럿 안정화 제트버너의 예혼합 화염이 미연가스 영역 난류특성에 미치는 영향)

  • Lee, Dae Hoon;Kwon, Sejin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.9
    • /
    • pp.1172-1177
    • /
    • 1999
  • Comparisons of measured turbulence properties in the unburned gas region of turbulent premixed flame stabilized by pilot flame, in cases of combusting and non-combusting flow conditions, are presented. Methane-air premixed jet at fuel equivalence ratio of 0.6 and 1.0 and Reynolds number of 7,000 was diagnosed using two-color laser velocimeter to obtain turbulence statistics. Same set of measurements was repeated at 21 locations within the unburned gas region of both combusting and non-combusting conditions. Velocity data were analyzed to evaluate the spatial distribution of turbulence properties including Reynolds stress, probability densities, joint probability densities and auto correlations. Contrary to assumptions of current theoretical models, significant influence of flame was observed in every property that was studied in the present investigation. The effective viscosity increased ten-fold when flame was on from cold flow values. The effect of mixing on joint probability as well as in turbulence intensity was suppressed by the flame. The measurements suggest that common assumptions of premixed flame model may result in sizable error in prediction of flame length and temperature distribution in near-field.

Evaluating Surface dose of Treatment Immobilization Devices according to their Electron Energy (전자선에너지에 따른 치료보조기구의 표면선량 평가)

  • Park, Chul-Woo;Im, In-Chul
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.6
    • /
    • pp.360-363
    • /
    • 2010
  • This study evaluated surface dose of treatment immobilization devices such as Themo-plastic, Vac-lock, Cotton and Plaster according to their electron energy. Using a linear accelerater, a plane parallel chamber was set up on 6Mev, 9Mev, 12Mev and 15Mev. A distance between a source and a surface was 100cm and a field size was 10cm*10cm. An incident angle was 0 degree and a radiation dose was 100MU. To decrease an error, the measurement repeated 3 times. The analysis reveals that the surface dose of Vac-lock was the highest and Themo-plastic, Plaster and Cotton were high in order.

Buildup Characteristics of Radiophotoluminescent Glass Dosimeters with Exposure Time of X-ray (엑스선의 조사시간에 따른 형광유리선량계의 빌드업 특성)

  • Kweon, Dae Cheol
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.5
    • /
    • pp.256-263
    • /
    • 2017
  • By using the buildup characteristics of the radiophotoluminescence glass dosimeter(RPLGD), it is aimed to help the measurement of the accurate dose by measuring the radiation dose according to the time of the glass element. Five glass elements were arranged on the table and the source to image receptor distance(SID) was set to 100 cm for the build-up radiation dose measurement of the fluorescent glass dosimeter glass element(GD-352M). Radiation doses and saturation rates were measured over time according to irradiation time, with the tube voltage (30, 60, 90 kVp) and tube current (50, 100 mAs) Repeatability test was repeated ten times to measure the coefficient of variation. The radiation dose increased from 0.182 mGy to 12.902 mGy and the saturation rate increased from 58.3% with increasing exposure condition and time. The coefficient of variation of the glass elements of the fluorescent glass dosimeter was ranged from 0.2 to 0.77 according to the X - ray exposure conditions. X - ray exposure showed that the radiation dose and saturation rate were increased with buildup characteristics, and degeneration of glass elements was not observed. The reproducibility of the variation coefficient of the radiation generator was included within the error range and the reproducibility of the radiation dose was excellent.

Simplified MMSE Detection with SoIC for Iterative Receivers in Multiple Antenna Systems (다중 안테나 시스템에서 연 간섭 제거를 이용한 저 복잡도 MMSE 신호 검출 방법)

  • Kim, Jong-Kyung;Seo, Jong-Soo
    • Journal of Advanced Navigation Technology
    • /
    • v.13 no.3
    • /
    • pp.385-392
    • /
    • 2009
  • Simplified minimum mean square error (MMSE) detection technique combined with soft interference cancellation(SoIC) is proposed for iterative receivers in multiple antenna systems. To avoid repeated matrix inversions required to obtain the MMSE filter coefficients during the iteration between the soft detector and decoder, simplified matrix inversion techniques are applied to calculate the filter coefficient matrix. Simulation results show that the proposed MMSE detections with SoIC indicate a comparable or slightly degraded detection performance while achieving a significantly reduced complexity as compared to the conventional MMSE detection with SoIC.

  • PDF

Sources of Variability of Multiple Self-reported 24-hour Recalls in Dietary Survey (식이조사방법중 자기 기록식 24시간 회상 반복 조사의 변이원에 관한 연구)

  • 김연희
    • Journal of Nutrition and Health
    • /
    • v.30 no.3
    • /
    • pp.349-359
    • /
    • 1997
  • This study was designed to study sources of variability(subjects, day by day, season, day of week, sequence, number of repeated days, compliance etc.) in multiple 24-hour dietary recall method. Dietary intakes of college women in Seoul were obtained using 24-hour dietary recalls, consecutive 7 days, 4 times for 1 year. The result of this study shows that 1) the reproducibility of multiple 24-hour recalls is low(intraclass correlation coefficient<0.3), 2) the intraindividual variations of all nutrients are more than 80%, 3) the major components of variation are interindividual vriability and intraindividual variability(within person variability and methodologic error). There were small but statistically significant season and compliance effects. 4) the ratio within-person varation to between-person variation for absolute and transformed nutrient intakes except some nutrients such as vitamin A, vitamin C, energy from protein and fat etc, was less than 1.7 the minimum numbers of days needed in 24-hour dietary recalls to estimate usual intake for this group were 1 to 21 days. And the numbers of days needed to get the usual intake of an individual varied among individuals and within individuals for different nutrients, ranged from 1 days for log carbohydrate(% energy) to 470 days for Na. 6) There were greater than 0.7 correlation coefficients between the average nutrient intakes of 12 days and intakes of 28 days. Therefore, it was desirable to take the 24-hour recall more than 12 times, repeating 3 days every season.

  • PDF

The Effect of System Characteristic of E-learning Systems and Self-Efficacy on Learning Performance (정보기술 e-서비스품질의 이용자 지각과 이용의도에 관한 연구)

  • Kim, Yong-Beom;Lee, Mee-Jeong
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2009.04a
    • /
    • pp.281-294
    • /
    • 2009
  • Recently the information system introduction and the application which use the computer are increasing. The efficient operation of information system helps corporations to improve productivity, customer service and corporate competitive power. SaaS(Software as a Service), which is the developed type of outsourcing in the area of information technology, is to use standardized and packaged application by hosting from the outside of enterprise. SaaS is not developed yet as much as people's interest about that in the initial stage, but its related technology and service capacity are accumulated after repeated trial and error, and it's ready to activate the industry. In the area of information system, studies on the measurement of service quality were followed. But there is little study on service quality measurement in the field of SaaS(Software as a Service). The purpose of this study was to divides the SaaS with e-SERVQUAL and it consider the relationship with the perceived recognition and the usage intention. According to this, variables of traditional research were rejected because SaaS is not developed yet in Korea. But information had a strong effect on perceived recognition. Therefore, business related with in SaaS must have provided a correct information about various applications.

  • PDF