• 제목/요약/키워드: repeated addition

검색결과 868건 처리시간 0.033초

모터부하 특성에 따른 국내 전력계통의 전압 지연 회복 현상 분석 (An Analysis of Delayed Voltage Recovery Phenomenon according to the Characteristics of Motor Load in Korean Power System)

  • 이윤환
    • 전기학회논문지P
    • /
    • 제65권3호
    • /
    • pp.178-182
    • /
    • 2016
  • FIDVR(Fault Induced Delayed Voltage Recovery) is a phenomenon that recovery of the system voltage level delays after the fault. Cause of FIDVR phenomenon is motor load characteristic about voltage and reactive power. In low voltage condition, the motor go to stall state that consume large amount of reactive power. As a result, the voltage recovery problem is that of repeated occurrences of sustained low voltage following faults on the system. In this paper, analysis the characteristics of the motor load. And using the korean power system actual data, perform a case studies to voltage delay recovery phenomenon alleviation method. Change of each parameters by analyzing the effect on system and selecting an influence parameter. In addition, dynamic characteristic analysis of the resulting difference in the proportion by the motor load in power systems, considering the effect on the voltage stability.

코카인으로 유도된 행동과다, 역내성 및 Dopamine 수용체 초과민성에 미치는 인삼 Saponin의 효과 (Effects of Ginseng Saponins on Cocaine-Induced Hyperactivity, Reverse Tolerance and Dopamine Receptor Super-sensitivity in Mice)

  • 김학성;정주연
    • Journal of Ginseng Research
    • /
    • 제19권2호
    • /
    • pp.101-107
    • /
    • 1995
  • The present study was undertaken to examine the effects of ginseng saponins [ginseng total saponin (GTS), protopanaxadiol saponin (PD) and protopanaxatriol saponin (PT)] on the hyperactivity, reverse tolerance and dopamine receptor super-sensitivity induced by cocaine. A single treatment with cocaine produced hyperactivity. Repeated administration of cocaine developed reverse tolerance and dopamine receptor super-sensitivity was also developed in reverse tolerant mice which had received the same cocaine. The hyperactivity and the developments of reverse tolerance and dopamine receptor super-sensitivity by cocaine were inhibited by ginseng saponins. From these results, it is proposed that ginseng saponins may be useful for the prevention and therapy of the adverse actions of cocaine. In addition, the rank order of inhibitory potential was observed as PT>GTS>PD. Key words Cocaine, hyperactivity, reverse tolerance, dopamine receptor super-sensitivity, ginseng saponins.

  • PDF

멧돼지에 의한 농작물 피해 방지를 위한 유해조수 퇴치 시스템 (Wild Animal Repellent System For Prevention of Crop Damage By Wild Boars)

  • 하영서;심재창
    • 한국멀티미디어학회논문지
    • /
    • 제24권2호
    • /
    • pp.215-221
    • /
    • 2021
  • The agricultural is plagued by agricultural damage from wild boars every year. As a result, research on systems to repelling wild boars continues, and most of the systems are to detect objects with body temperature through sensors and then repelling them with actions such as light and sound. The problems of these system are operating regardless of wild boars and people, which can cause significant accident when using electric fence. In addition, If the same repelling action is repeated, wild boars can be adapted to that repelling action. As a solution to the two problems, Adaptation problem can be solved by random sounds and distinction problem can be solved by YOLO V4.

수소 충전소용 유량제어밸브(FCV)의 구조 및 피로해석을 통한 내구 성능 평가 (Durability Assessment by Structural and Fatigue Analysis of Flow Control Valves (FCVs) for Hydrogen Refueling Stations)

  • 최인호;하태일;김한상
    • 한국수소및신에너지학회논문집
    • /
    • 제33권3호
    • /
    • pp.240-246
    • /
    • 2022
  • This study was conducted to develop a domestic product for a flow control valve for a hydrogen refueling station, and a domestic prototype was manufactured and the durability performance evaluation was conducted through comparison with an imported products. The stress generated by the internal pressure was checked and safety was confirmed using a commercial structural analysis program, ABAQUS, in accordance with the withstand pressure test standards. In addition, after identifying the weak areas the fatigue life was predicted through a commercial software, fe-safe. This fatigue analysis showed that the hydrogen gas repeated test criteria were satisfied.

Immunogenicity of botulinum toxin

  • Wee, Syeo Young;Park, Eun Soo
    • Archives of Plastic Surgery
    • /
    • 제49권1호
    • /
    • pp.12-18
    • /
    • 2022
  • Botulinum toxin treatment is the most common non-surgical cosmetic treatment. Although there are many available treatments using botulinum toxin, their effects are temporary and repeated injections are required. These frequent injections can trigger an immunological response. In addition, botulinum toxin acts as an antigen in the body; thus, its effect disappears progressively due to this immunological reaction, which may cause treatment failure. Active botulinum toxin consists of a core neurotoxin and complexing proteins, the exact effects of which remain unclear. However, the complexing proteins are closely related to the immune response and the formation of neutralizing antibodies. Since neutralizing antibodies can lead to treatment failure, their formation should be prevented. Furthermore, various methods of detecting neutralizing antibodies have been used to predict treatment failure.

측두하악장애 치료에서 환자교육 및 자가 요법의 방법과 그 역할에 대한 고찰 (The role of patient education and self-management method in the treatment of temporomandibular disorder)

  • 최영윤
    • 대한치위생과학회지
    • /
    • 제1권1호
    • /
    • pp.65-71
    • /
    • 2018
  • In the treatment of temporomandibular disorders, patient education and self-management method are necessary in addition to other specialized treatments to prevent recurrence of symptoms or development of chronic pain. The causes of temporomandibular disorders are very diverse, but in many cases the patients continue to suffer or experience recurrence because of the repeated exposure to micro traumas such as oral parafunctions, bad habits, and harmful eating habits. Much better prognosis is expected if a dental hygienist who is teamed up with a specialist in the dental clinic can perform patient education and management based on the understanding of temporomandibular disorder.

일정 및 변동 축력을 받는 철근콘크리트 기둥의 내진성능 평가 (Seismic Performance Evaluation of Reinforced Concrete Columns Under Constant and Varying Axial Forces)

  • 이도형
    • 한국지진공학회논문집
    • /
    • 제28권1호
    • /
    • pp.59-65
    • /
    • 2024
  • This paper describes the seismic performance evaluation of reinforced concrete bridge columns under constant and varying axial forces. For this purpose, nine identical circular reinforced concrete columns were designed seismically by KIBSE (2021) and KCI (2021). A comparison of lateral forces with theoretical strength shows that the safety factor for columns under varying axial forces is less marginal than those under constant axial forces. In addition, columns under varying axial forces exhibit significant fluctuations in the hysteretic response due to continuously varying axial forces. This is particularly prominent when many varying axial force cycles within a specific lateral loading cycle increase. Moreover, the displacement ductility of columns under varying axial forces does not meet the code-specified required ductility in the range of varying axial forces. All varying axial forces affect columns' strength, stiffness, and displacement ductility. Therefore, axial force variation needs to be considered in the lateral strength evaluation of reinforced concrete bridge columns.

엔지니어링 플라스틱 슬릿댐퍼의 수치해석적 연구 (Numerical Analysis of Engineering Plastics Slit Damper)

  • 김유성;김기철
    • 한국공간구조학회논문집
    • /
    • 제24권3호
    • /
    • pp.79-86
    • /
    • 2024
  • Recently, steel dampers are widely used as seismic reinforcement devices. Steel dampers have the advantage of being easy to manufacture and being able to absorb a lot of energy through stable hysteresis behavior. However, there is a possibility that the steel damper may be damaged due to fatigue caused by repeated seismic loads. In this study, the seismic performance of steel dampers and engineering plastic dampers with different physical characteristics were compared and analyzed. In addition, numerical analysis was performed on a hybrid damper that combines a steel damper and an engineering plastic damper. It is more effective to apply engineering plastic dampers to structures that experience significant displacement due to seismic loads. The behavior of hybrid dampers combining steel dampers and engineering plastic dampers is dominated by steel dampers. A hybrid damper in which an engineering plastic damper yields after a steel damper yields can effectively respond to various seismic loads and secure high ductility and excellent seismic performance.

Evaluation of durability performance for maintenance of tunnel structures due to repeated freezing and thawing

  • Jai-Wook An;Joon-Shik Moon;Hong-Kyoon Kim
    • Geomechanics and Engineering
    • /
    • 제38권6호
    • /
    • pp.593-601
    • /
    • 2024
  • In this paper, the quantitative evaluation method is presented for the durability performance of mountain tunnel concrete linings experiencing freezing and thawing during winter season. To analyze the freeze-thaw characteristics of lining, the freezing time of the concrete lining was measured by the outside temperature. The heat flow analysis was conducted based on the freezing time measured through the indoor experiment, and based on this, the energy required to freeze the concrete lining by the temperature of the outside air could be analyzed. In addition, the temperature change during the winter season was measured through an instrument installed on the actual tunnel concrete lining, and based on the results of indoor and field experiments, criteria for freeze-thaw environment evaluation and progress evaluation were prepared. Also, an equation using the freezing index was proposed through regression analysis.

유전자 재조합 Human Factor VIII(GC-γ AHF)의 안전성에 관한 연구 (Safety Evaluation of Recombinant Human Factor VIII(GC-γ AHF))

  • 김민영;손장원;신민기;배미옥;김현우;최진혁;김준성;문서현;김정현
    • Toxicological Research
    • /
    • 제18권1호
    • /
    • pp.87-98
    • /
    • 2002
  • This study was conducted to evaluate the safety of a recombinant human Factor VIII(GC-$\gamma$ AHF) manufactured by Korea Green Cross Company with different technology according to the Regulation of Korean Food and Drug Administration (l 998. 12. 3). In acute toxicity test, both genders of Sprague-Dawley rats and Beagle dogs were administered intravenously with GC-$\gamma$ AHF of three doses (3,125, 625 and 125 IU/kg), and single dose of 3,125 IU/kg, respectively. No dead animal and abnormal autopsy findings were found in Control and GC-$\gamma$ AHF treated group. Therefore, the 50% lethal dose ($LD_{50}$) of GC-$\gamma$ AHF was conidered to be higher than 3,125 IU/kg in rats and dogs. In the four weeks repeated intravenous toxicity study, GC-$\gamma$ AHF was administrated intravenosly to both genders of rats and dogs with 3 doses (500, 150, 50 IU/kg). There were neither dead animals nor significant changes of body weights during the experimental Period. In addition, no significant GC-$\gamma$ AHF related changes were found in clinical sign, urinalysis and other finding. Statistically changes were observed in hematological, biochemical and organ weight parameters of treated groups: however these changes were not dose dependent. No histopathological lesion were observed in both control and treated animals. Above data suggest that no observed adverse effect level of test materials in rats and dogs might be over 500 IU/kg/day in this study. In ocular irritation test, any injury on iris, conjunctiva and cornea in rabbits were not observed. The acute ocular irritation index (A.O.I.), mean ocular irritation index (M.O.I.) and Day-7 individual ocular irritation Index (I.O.I.) of GC-$\gamma$ AHF were 0. In the primary skin Irritation test, the primary irritation index (P.I.I.) oj GC-$\gamma$ AHF were 0. Therefore, the GC-$\gamma$ AHF is considered not to have the primary skin and eye toxicity in rabbits. In active systemic anaphylaxis (ASA) test, GC-$\gamma$ AHF and GC-$\gamma$ AHF emulsified with Freund's complete adjuvant (FCA) did not induce any symptom of anaphylactic shock in guinea pigs. In passive cutaneous anaphylxis (PCA) test, after sensitization with antisera of GC-$\gamma$ AHF sensitized mice, blue spots were observed on the hypodermis of back of rats, but diameter of each spot was smaller than 5 mm in each test groups except the positive control group. Based on the results of this study, GC-$\gamma$ AHF is not conidered to have any antigenic potential. In conclusion, at levels of up to 500 IU/kg, GC-$\gamma$ AHF did not produce treatment-related toxicity under the conditions of these acute-, four week repeated-toxicity, primary skin and eye toxicity, and antigenicity test.