• 제목/요약/키워드: repaired concrete structures

검색결과 92건 처리시간 0.024초

Service life of concrete culverts repaired with biological sulfate-resisting mortars

  • Hyun-Sub, Yoon;Keun-Hyeok, Yang;Nguyen, Van Tuan;Seung-Jun, Kwon
    • Computers and Concrete
    • /
    • 제30권6호
    • /
    • pp.409-419
    • /
    • 2022
  • The purpose of this study is to examine the effectiveness of biological repairing mortars on restoring the structural performance of a sewage culvert deteriorated by sulfate attack. The biological mortars were developed for protecting concrete structures exposed to sulfate attack based on the block membrane action of the bacterial glycocalyx. The diffusion coefficient of sulfate ions in the biological mortars was determined from the natural diffusion cell tests. The effect of sulfate-attack-induced concrete deterioration on the structural performance of culverts was examined by using the moment-curvature relationship predicted based on the nonlinear section lamina approach considering the sulfuric-acid-induced degradation of the structure. Typical analytical assessments showed that biological mortars were quite effective in increasing the sulfate-resistant service life of sewage culverts.

Rapid retrofit of substandard short RC columns with buckled longitudinal bars using CFRP jacketing

  • Marina L. Moretti
    • Earthquakes and Structures
    • /
    • 제24권2호
    • /
    • pp.97-109
    • /
    • 2023
  • This experimental study investigates the effectiveness of applying carbon fiber reinforced polymer (CFRP) jackets for the retrofit of short reinforced concrete (RC) columns with inadequate transverse reinforcement and stirrup spacing to longitudinal rebar diameter equal to 12. RC columns scaled at 1/3, with round and square section, were subjected to axial compression up to failure. A damage scale is introduced for the assessment of the damage severity, which focusses on the extent of buckling of the longitudinal rebars. The damaged specimens were subsequently repaired with unidirectional CFRP jackets without any treatment of the buckled reinforcing bars and were finally re-tested to failure. Test results indicate that CFRP jackets may be effectively applied to rehabilitate RC columns (a) with inadequate transverse reinforcement constructed according to older practices so as to meet modern code requirements, and (b) with moderately buckled bars without the need of previously repairing the reinforcement bars, an application technique which may considerably facilitate the retrofit of earthquake damaged RC columns. Factors for the estimation of the reduced mechanical properties of the repaired specimens compared to the respective values for intact CFRP-jacketed specimens, in relation to the level of damage prior to retrofit, are proposed both for the compressive strength and the average modulus of elasticity. It was determined that the compressive strength of the retrofitted CFRP-jacketed columns is reduced by 90% to 65%, while the average modulus of elasticity is lower by 60% to 25% in respect to similar undamaged columns jacketed with the same layers of CFRP.

Experimental and FE investigation of repairing deficient square CFST beams using FRP

  • Mustafa, Suzan A.A.
    • Steel and Composite Structures
    • /
    • 제29권2호
    • /
    • pp.187-200
    • /
    • 2018
  • This paper handles the repairing of deficient square Concrete-Filled Steel-Tube (CFST) beams subject to bending through an experimental and numerical program. Eight square-CFST beams were tested. A 5-mm artificial notch was induced at mid-span of seven beams, four of them were repaired by using CFRP sheets and two were repaired by using GFRP sheets. The beam deflection, strain and ultimate moments were recorded. It was found that providing different cut-off points for the different layers of FRP sheets prohibited failure at termination points due to stress concentrations. Using different lengths of FRP sheets around the notch retarded crack propagation and prevented FRP rupture at the crack position. Finite element analysis was then conducted and the proposed FE model was verified against the recorded experimental data. The influence of various parameters as FRP sheet length, tensile modulus and the number of layers were studied. The moment capacity of damaged square-CFST beams was improved up to 77.6% when repaired by using four layers of CFRP, however, this caused a dramatic decrease in beam deflection. U-wrapping of notched-CFST beam with 0.75 of its length provided a comparable behaviour as wrapping the full length of the beam.

염해를 입은 RC 구조물의 최적 보수주기 산정 기법에 관한 연구 (Estimation of Optimum Maintenance Cycle for the Chloride Damaged RC Structure)

  • 윤선영;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2010년도 춘계 학술논문 발표대회 1부
    • /
    • pp.235-236
    • /
    • 2010
  • Since many structures in the sea environment are damaged by chloride, appropriate repair strategy is required. Therefore in the paper, optimum period for the RC structure's repair is calculated with consideration of economic efficiency. Moreover, when the concrete members are repaired with the other material such as polymer mortar forr section restoration, their expected service life also calculated to predict more accurate repair period during the life span.

  • PDF

탄산화가 진행된 기존 RC구조물의 보수 공법 적용 후 탄산화 진행 예측 (Predicting Carbonation Progress of Carbonation Repaired RC Structures Repair)

  • 이형민;이한승
    • 한국건축시공학회지
    • /
    • 제17권3호
    • /
    • pp.235-243
    • /
    • 2017
  • 본 연구에서는 탄산화가 이미 진행된 콘크리트 구조물을 대상으로 촉진 탄산화 실험을 실시하였다. 각 보수재별 탄산화 속도계수를 도출 후 보수후의 탄산화 진행 예측식을 이용하여 탄산화 진행 예측한다. 또한 신뢰성 확보를 위하여 FDM과 FEM 해석을 통한 탄산화 깊이 예측을 비교했다. 그 결과 보수후 탄산화 예측식을 이용하면 탄산화 깊이를 예측할 수 있으며, 초기 $Ca(OH)_2$ 농도 40%로 가정할 때 해석 값과 실험값이 거의 유사함을 알 수 있었다.

Evaluation of Models for Estimating Shrinkage Stress in Patch Repair System

  • Kristiawan, Stefanus A.
    • International Journal of Concrete Structures and Materials
    • /
    • 제6권4호
    • /
    • pp.221-230
    • /
    • 2012
  • Cracking of repair material due to restraint of shrinkage could hinder the intended extension of serviceability of repaired concrete structure. The availability of model to predict shrinkage stress under restraint condition will be useful to assess whether repair material with particular deformation properties is resistance to cracking or not. The accuracy in the prediction will depend upon reliability of the model, input parameters, testing methods used to characterize the input parameters, etc. This paper reviews a variety of models to predict shrinkage stress in patch repair system. Effect of creep and composite action to release shrinkage stress in the patch repair system are quantified and discussed. Accuracy of the models is examined by comparing predicted and measured shrinkage stress. Simplified model to estimate shrinkage stress is proposed which requires only shrinkage property of repair material as an input parameter.

섬유 보강 모르타르를 사용한 보수공법의 내구성능 평가에 관한 연구 (A Study on the Evaluation for Durability Performance of the Repair Method Using Fiber Reinforced Mortar)

  • 류금성;고경택;김방욱;윤필용;김진수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계 학술발표회 논문집(II)
    • /
    • pp.309-312
    • /
    • 2006
  • In this study, the repair method using PVA fiber reinforced mortar evaluated on durability performance. Test items are compressive strength, flexural strength, carbonation, freezing-thawing. As for the test results, it was found that durability performance of the repair method using PVA fiber mortar showed more better than the existing repair method. Therefore, appling on the repair method using PVA fiber mortar, the repaired concrete structures can be increased to service life.

  • PDF

사용중 보강되는 부재의 보강설계법 연구 (A Study for Numerical Procedure of Strengthening Capacity in Field Structure)

  • 한만엽;이원창
    • 콘크리트학회논문집
    • /
    • 제11권3호
    • /
    • pp.13-21
    • /
    • 1999
  • Recently, many strengthening methods are developed to repair damaged structures, especially, steel plate or carbon fiber sheet bonding methods are widely used. For the bonding methods, the strengthening materials are bonded when the original structure is under loading, with causes the difference of initial stresses between original member and bonded material. However, current design method or theory, which mostly depends on ultimately strength design, cannot account the difference of initial stresses between members, and it disregards the reduction of nominal strength. In this study, a new strengthening design theory and program which can account the difference of initial stresses are developed, and applied to the case when a structure in service is repaired. In order to verify the validity of the theory and the program, a test result is referred and compare with the results and it is showed that the calculated values are almost same as the referred data and finally proved that the program is reliable. The results showed that the amount of strengthening material depends on the status of damages of structure, and the nominal strength is reduced depending on the degree of damages.

구조물의 손상 상태에 따른 보강설계법 연구 (The Strengthening Desing Method Considering Damages of Structure)

  • 한만엽;이택성
    • 콘크리트학회논문집
    • /
    • 제11권3호
    • /
    • pp.35-45
    • /
    • 1999
  • Recently, many strengthening methods are developed to repair damaged structures, especially, steel plate or carbon fiber sheet bonding methods are widely used. For the bonding methods, the strengthening materials are bonded when the original structure is under loading, which causes difference of initial stresses between original member and bonded material. However, current design method or theory, which mostly depends on ultimately strength design, cannot account the difference of initial stresses between members, and it disregards the reduction of nominal strength. In this study, a new strengthening design theory and program which can account the difference of initial stresses are developed, and applied to the case when a structure in service is repaired. In order to verify the validity of the theory and the program, a test result is referred and compared with the results and it is showed that the calculated values are almost same as the referred data and finally proved that the program is reliable. The results showed that the amount of strengthening material depends on the status of damages of structure, and the nominal strength is reduced depending on the degree of damages.

PVA 섬유 보강 보수 모르타르의 내구성 평가 (Evaluation on the Durability of PVA Fiber Reinforced Mortar for Repair)

  • 고경택;류금성;이장화;강수태;윤필용;김진수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.621-624
    • /
    • 2006
  • In this study, the repair method using PVA fiber reinforced mortar evaluated on durability performance. Test of salt injury, carbonation, freezing-thawing, chemical attack, permeability was performed As for the test results, it was found that durability performance of the repair method using PVA fiber mortar showed more better than the existing repair method. Therefore, appling on the repair method using PVA fiber reinforced mortar, the repaired concrete structures can be increased to service life.

  • PDF