• Title/Summary/Keyword: repair technique

Search Result 683, Processing Time 0.035 seconds

Surgical anatomy of transversus abdominis muscle for transversus abdominis release

  • Pauline Shanthi;Femina Sam;Jenny Jacob;Beulah Roopavathana S;Suganthy Rabi
    • Anatomy and Cell Biology
    • /
    • v.57 no.3
    • /
    • pp.363-369
    • /
    • 2024
  • Transversus abdominis release (TAR) is a myofascial release technique which helps in surgical repair of large ventral abdominal wall defects. In this procedure, the medial margin of muscular part of transversus abdominis (TA) is of great importance. Hence, the authors sought to describe the extent of medial margin of TA muscle. The surgical steps of TAR were performed in 10 formalin-fixed cadavers and distance between medial margin of TA muscle, lateral margin of rectus abdominis, to linea alba at five anatomical levels were documented respectively. The distance between the inferior epigastric vessels and the medial border of TA muscle was also noted. The TA muscle was within the posterior rectus sheath in all cadavers, at the xiphisternum (R, 61.6 mm; L, 58.9 mm), and at midway between xiphisternum and umbilicus (R, 25.4 mm; L, 27.1 mm). The TA muscle exited the posterior rectus sheath between this point and the umbilicus. The mean incongruity at the next three levels were -24.6 mm, -24.9 mm, and -22.9 mm respectively on the right and -21.4 mm, -19.9 mm, and -18.9 mm respectively on the left. The mean distance between the medial border of TA and inferior epigastric vessels was 18.9 mm on the right and 17.2 mm on the left. The muscular part of TA was incorporated within the posterior rectus sheath above the umbilicus, and it completely exited the rectus sheath at the umbilicus. This is contrary to the traditional understanding of posterior rectus sheath formation.

Mitral Valvuloplasty using New Mitral Strip (Mitracon^{(R)}$) (새로운 Strip (Mitracon^{(R)}$)을 이용한 승모판막 성형술)

  • Kang, Seong-Sik;Kim, Sang-Pil;Song, Meong-Gum
    • Journal of Chest Surgery
    • /
    • v.41 no.3
    • /
    • pp.320-328
    • /
    • 2008
  • Background: Numerous surgical devices for mitral repair have been used in the past with good results. In this study we describe a simple annuloplasty technique with using a new device ($Mitracon^{(R)}$). The aim of this study was to assess its efficacy and surgical results with using $Mitracon^{(R)}$. Material and Method: From May 2003 to October 2005, 46 patients (21 women and 25 men (mean age of $51.4{\pm}17.8$ years) with mitral regurgitation from various causes were treated with either the $Mitracon^{(R)}$ (the $Mitracon^{(R)}$ group) or the Capentier Edward rigid ring (the CE group). The median follow-up duration was 18.9 months. Result: The mean grade of mitral regurgitation before and immediately after surgery in the $Mitracon^{(R)}$ group and the CE group decreased from $3.2{\pm}0.8$ to $0.6{\pm}0.7$ and $3.4{\pm}0.7$ to $0.3{\pm}0.5$, respectively. There were no significant changes in the ejection fraction either between the two groups or before and immediately after surgery. No deaths were seen in either group. Early postoperative echocardiography of all 46 patients showed only trivial mitral regurgitation or none at all. Echocardiography at a median of 18.9 months also showed no progression in mitral regurgitation. The mean grade of mitral regurgitation in the $Mitracon^{(R)}$ group at this time point decreased from $3.2{\pm}0.8$ to $0.8{\pm}0.7$ (p<0.05). The CE group also showed a similar degree of decrease from $3.4{\pm}0.7$ to $0.3{\pm}0.6$ (p<0.05). The mitral valve area in the $Mitracon^{(R)}$ group at 1 year follow-up was $3.3{\pm}0.9cm^2$. The mitral valve area in the CE group was $2.7{\pm}0.6cm^2$. The mean mitral pressure gradient in the $Mitracon^{(R)}$ group at 1 year follow-up was $3.1{\pm}1.3$ mmHg. The mean pressure gradient in the CE group was $4.5{\pm}2.1$ mmHg, although any statistical significant difference for this between the groups was not reached. Conclusion: The present study showed the described technique to be safe and effective in the intermediate term. Because long term results are unavailable, a more extensive prospective randomized multicenter trial may be warranted to determine whether this procedure should be generally applied for repair of mitral valve disease.

Coronary Artery Bypass Surgery with Radial Artery -Early Results (요골동맥을 이용한 관상동맥우회술 -조기성적)

  • 나찬영;이영탁;박국양;이해영;김욱성;박?현;홍민수;심재천;권오춘
    • Journal of Chest Surgery
    • /
    • v.30 no.3
    • /
    • pp.275-281
    • /
    • 1997
  • The radial artery as a graft for myocardial revascularization was introduced by Carpentier in the early 1970s. Mid-term results were unfortunately discoura ing, and the clinical experience with this graft was interrupted. At the end of the 1980s, these authors reproposed the same arterial conduit with more satisfying results, because of improved technique and pharmacological management of the graft. Between October 1994 and July 1995, 36 patients underwent myocardial revascularization with a radial artery graft in Seiong General Hospital. Left internal mammary artery was concomitantly used as a pedicled Vift in 34 patients. Fifteen patients (42%) had a complete arterial waft revascularization. A total of 12) distal anastomoses were performed (average 3.4 per patient), including 36 left internal mammary artery wafts (two sequential in 2 patients), and 23 saphenous vein grafts. The remaining 64 distal anastomoses were perFormed with radial artery grafts (mean 1.8 per patient). The radial arteries were anastomosed to the circumflex (n=38), diagonal (n= 18), right coronary(n=G), and left anterior descending coronary artery(n=2). The percent ge of radial artery graft anastomoses (64) to the total anastomoses(123) was 52%. The radial artery was used as a single graft in 10 patients, as a sequential graft in 25 patients, and two grafts in 1 patient. Twenty patients underwent associated procedures coronary endarterectomy (14), coronary artery patch angioplasty (4), mitral valve repair (1), and repair of ventricular septal rupture (1). One patient died of low cardiac output syndrome and the others had no perioperative myocardial infarction. There are no ischemic and functional complications in the arm or hand aftcr removal of the radial artery. Only 1 patient required reexploration of the am, for the hematoma evacuation, and 2 patients complained transient thumb dysesthesia of the side of the havested arm. This dysesthesia improved within one month. Postoperative angiovaphic controls were obtained in 11 patients(31%) postoperative 79 to 210 days (mean 126 days). The patency rate were as follows : left internal mammary artery (100%), saphcnous vein (100%), and radial artery(95%). We concluded that the radial artery is useful alternative graft, but long term clinical and angiographic studies are required to derterminc whether wider application is warranted.

  • PDF

Aortic Valvuloplasty Using Leaflet Extension Technique (판막첨 연장술을 이용한 대동맥판막 성형술의 중기성적 평가)

  • Ahn, Hyuk;Kim, Hyun-jo
    • Journal of Chest Surgery
    • /
    • v.30 no.7
    • /
    • pp.656-662
    • /
    • 1997
  • Aortic valvuloplasty has recently gained attention as an attractive alternative procedure for aortic valvular disease. Between March 1995 to August 1996, 14 patients with pure aortic regurgitation(AR) underwent aortic alvuloplasty using leaflet extension with glutaraldehydepreserved autologous pericardium. There were 11 males and 3 females, and the mean age was 34.8 $\pm$ 15.3 years. Preoperative echocardiography and cardiac catheterization revealed that the degree of AR was mean 3.4$\pm$0.65, and more than moderate degree of mitral regurgitation(MR) were detected in 4 patients. In 12 patients, 3 leaflets were extended and in another 2 patients only one deformed leaflet was extended. Concomitant mitral valvuloplasty (MVP) was performed in 4 patients. The competency of the aortic valve after completion of repair was evaluated by the transesophageal echocardiography in operating theater, and there was no aortic and mitral stenosis or regurgitation. In an early postoperative echocardiography, trivial AR was detected in 3 patients and mild MR in 1 patient. The end-systolic and end-diastolic dimensions of the left ventricle were decreased significantly(p<0.05) as compared with those of preoperative values. T ere was no mortality and no significant postoperative complication encountered. Late complication developed in 2 patients during the follow-up period(mean 7.9$\pm$ 5.9 months). One patient underwent AVR on postoperative 7th month due to endocarditis, and the another patient with Behcet's disease underwent Ross operation at postoperative 4th month. In conclusion, AVP of leaflet extension technique offers an excellent early clinical result and represents a good alterna!ivy surgical treatment for the pure AR especially in young age group, although long-term follow-up is necessary to determine the durability of glutaraldehyde-preserved autologous pericardium as a valve leaflet.

  • PDF

Outcome of Arthroscopic Suture Bridge Technique for Rotator Cuff Tear: Short Term Clinical Outcome In Full-thickness Tear With Fatty Degeneration Less Than Moderate Degree (회전근 개 파열에 대한 관절경적 교량형 봉합술의 결과: 지방 변성이 중등도 이하인 전층 파열에 대한 단기 추시 임상적 결과)

  • Cheon, Sang-Jin;Hur, Joon-Oh;Suh, Jeung-Tak;Yoo, Chong-Il
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.2
    • /
    • pp.180-188
    • /
    • 2009
  • Purpose: We evaluate the short-term clinical outcome of arthroscopic rotator cuff tendon repair with suture-bridge technique in patients with full thickness rotator cuff tear. Materials and Methods: 29 (male:17, female:12) consecutive shoulders treated with this index procedure and early rehabilitation were enrolled. Mean age was 56.4 years (range, 34~73 years) and mean follow-up period was 13 months (range, 12-15 months). Clinical outcomes were evaluated by using the University of California Los Angeles (UCLA) score, the Korean Shoulder Scoring System (KSS) and Visual Analogue Scale (VAS). Postoperative cuff integrity was evaluated through magnetic resonance imaging (MRI) and categorized by Sugaya classification. Results: Postoperative UCLA scores improved from 16.4 to 31.6 (p< 0.05) and KSS scores showed 88 at 6 months and 92 at last follow up. Preoperative VAS score was 8.6, which was decreased to 2.1 at 3 months and 1.4 at 6 months postoperatively. 28 patients (96.5%) had increase in range of motion. The follow up MRI was taken in 15 shoulders and the cuff integrity was type I in 6 cases, type II in 7, type III in 1 and type V in 1 by Sugaya classification. Conclusion: Arthroscopic suture-bridge technique resulted in good or excellent clinical outcome in 96.5% of the cases, so we think this technique is one of the reliable procedure for full-thicknes rotator cuff tear.

Clinical Results of Treatment of Distal Biceps Rupture (이두박근 원위부 파열의 임상적 치료 결과)

  • Chung, Duke-Whan;Hwang, Jung-Chul
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.8 no.1
    • /
    • pp.13-18
    • /
    • 2009
  • Purpose: To report the clinical results of patients treated for a rupture of the distal tendon of biceps brachii Materials and Methods: Between February 1987 and March 2004, we treated 16 patients with a rupture of the distal tendon of biceps brachii. 9 of 16 patients underwent surgical treatment. All cases were male, median age was 26.3(range, 16-48) years. The mean interval between injury and surgery was 4.7 days (range, 1~36 days). Operative correction was performed anatomically, using the two-incision technique(3 cases) or one-incision technique(6 cases). Clinical outcomes were evaluated one year after operation by assessing the review about the physical examination finding and radiologic findings with surgical findings, range of motion, muscle strength, subjective satisfaction, activity and return to previous occupation. and via telephone interview in cases of conservative treatment. Results: In cases of surgical treatment, 85.8%, 86.3% of flexion-extension and supination-pronation motion than healthy side were measured respectively. 75% of flexion power than healthy side was measured. Eight of nine(89%) were very satisfied. Eightl of nine returned to original job. In cases of conservative treatment, 65% of flexion power than pre-injury state was reported. Four of seven were satisfied, two were dissatisfied, one was very dissatisfied. Three of seven returned to original job. Conclusion: Early anatomic reconstruction can restore more strength and endurance for supination and flexion range and power. Conservative management may be considered for partial injuries, but operative repair must be considered in complete rupture, athletes, patient with high activity.

  • PDF

Hetzer Technique for Surgical Correction of Ebstein's Anomaly (Hetzer 술기를 이용한 엡스타인 기형의 수술적 교정)

  • Chung, Jin-Woo;Im, Yu-Mi;Jung, Sung-Ho;Yun, Tae-Jin
    • Journal of Chest Surgery
    • /
    • v.40 no.7 s.276
    • /
    • pp.473-479
    • /
    • 2007
  • Background: The Hetzer procedure for the correction of Ebstein's anomaly has the advantages of technical feasibility and incorporation of the atrialized right ventricle (RV) into the functional RV. Material and Method: We preformed a retrospective review of 11 patients with Ebstein's anomaly and they had undergone a Hetzer procedure between March 2002 and December 2006. Result: The median age at operation was 19.8 years (range: 6 months ${\sim}56$ years). There were 4 males and 7 females. All patients showed severe tricuspid regurgitation (TR) preoperatively, and arterial desaturation (<95%) was present in 3 patients. The original Hetzer technique was employed in 6 patients with the Carpentier type A anomaly. In the remaining 5 patients with the Carpentier type B or C anomalies, valve competence was restored at the level of the displaced tricuspid valve mechanism. Adjunct bidirectional cavo-pulmonary shunt, or one and a half ventricle repair strategy was employed for all the patients. The median follow-up was 8.6 months (range: $0.8{\sim}51.9$ months). There was no early or late death, and the immediate postoperative TR was trivial to mild in 8 patients. The median cardio-thoracic ratios on chest X-ray at the preoperative period and at postoperative 0, 1 and 6 months were 65%, 62%, 55% and 55%, respectively. Conclusion: The original or modified Hetzer procedure for Ebstein's anomaly shows excellent intermediate-term outcomes.

A Experimental Study on the Evaluation of Deteriorated Concrete Member Exposed One Side at High Temperature (고온에 일면 노출된 콘크리트부재의 손상깊이 평가를 위한 실험적 연구)

  • Lee, Joong-Won;Choi, Kwang-Ho;Hong, Kap-Pyo
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.3 s.93
    • /
    • pp.431-438
    • /
    • 2006
  • The determination of the depth of deteriorated concrete is one of the main problems in the structural assessment of concrete structures that have been subjected to a fire. This information is particularly important in order to optimize the future operations of repair/strengthening, or in decision-making concerning a possible demolition. The purpose of this study is to propose evaluation technique of damaged depth of concrete exposed at high temperature. In order to evaluate damaged depth of core picked at member under fire, the 24 specimens have been made with variables of concrete strength(20 MPa, 40 MPa, 60 MPa) and heating exposure condition in 600 and 800 for 2 hours. Color change analysis and water absorption after heating have been measured and split tensile stress test was performed to ka the residual compressive strength against the depth of specimen. The results show that the deeper of the depth from heating face, water absorption ratio is smaller and residual stress ratio is larger and the color of heated face is changed to red color. Using this technique at damage evaluation of fired structure, We evaluate damaged depth of member under fire and determine the reasonable strengthening range.

Development of the Phased Array Ultrasonic Testing Technique for Nuclear Power Plant's Small Bore Piping Socket Weld (원전 소구경 배관 소켓용접부 위상배열 초음파검사 기술 개발)

  • Yoon, Byung-Sik;Kim, Yong-Sik;Lee, Jeong-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.4
    • /
    • pp.368-375
    • /
    • 2013
  • Failure of small bore piping welds is a recurring problem at nuclear power plants. And the socket weld cracking in small bore piping has caused unplanned plant shutdowns for repair and high economic impact on the plants. Consequently, early crack detection, including the detection of manufacturing defects, is of the utmost importance. Until now, the surface inspection methods has been applied according to ASME Section XI requirements. But the ultrasonic inspection as a volumetric method is also applying to enforce the inspection requirement. However, the conventional manual ultrasonic inspection techniques are used to detect service induced fatigue cracks. And there was uncertainty on manual ultrasonic inspection because of limited access to the welds and difficulties with contact between the ultrasonic probe and the OD(outer diameter) surface of small bore piping. In this study, phased array ultrasonic inspection technique is applied to increase inspection speed and reliability. To achieve this object, the 3.5 MHz phased array ultrasonic transducer are designed and fabricated. The manually encoded scanner was also developed to enhance contact conditions and maintain constant signal quality. Additionally inspection system is configured and inspection procedure is developed.

Utility of a modified components separation for abdominal wall reconstruction in the liver and kidney transplant population

  • Black, Cara K;Zolper, Elizabeth G;Walters, Elliot T;Wang, Jessica;Martinez, Jesus;Tran, Andrew;Naz, Iram;Kotha, Vikas;Kim, Paul J;Sher, Sarah R;Evans, Karen K
    • Archives of Plastic Surgery
    • /
    • v.46 no.5
    • /
    • pp.462-469
    • /
    • 2019
  • Background Incisional hernia is a common complication following visceral organ transplantation. Transplant patients are at increased risk of primary and recurrent hernias due to chronic immune suppression and large incisions. We conducted a retrospective review of patients with a history of liver or kidney transplantation who underwent hernia repair to analyze outcomes and hernia recurrence. Methods This is a single center, retrospective review of 19 patients who received kidney and/or liver transplantation prior to presenting with an incisional hernia from 2011 to 2017. All hernias were repaired with open component separation technique (CST) with biologic mesh underlay. Results The mean age of patients was $61.0{\pm}8.3years\;old$, with a mean body mass index of $28.4{\pm}4.8kg/m^2$, 15 males (78.9%), and four females (21.1%). There were seven kidney, 11 liver, and one combined liver and kidney transplant patients. The most common comorbidities were hypertension (16 patients, 84.2%), diabetes (9 patients, 47.4%), and tobacco use (8 patients, 42.1%). Complications occurred in six patients (31.6%) including hematoma (1/19), abscess (1/19), seroma (2/19), and hernia recurrence (3/19) at mean follow-up of $28.7{\pm}22.8months$. With the exception of two patients with incomplete follow-up, all patients healed at a median time of 27 days. Conclusions This small, retrospective series of complex open CST in transplant patients shows acceptable rates of long-term hernia recurrence and healing. By using a multidisciplinary approach for abdominal wall reconstruction, we believe that modified open CST with biologic mesh is a safe and effective technique in the transplant population with complex abdominal hernias.