• Title/Summary/Keyword: repair cycle

Search Result 310, Processing Time 0.02 seconds

Design of Leakage Current Detecting Equipment of an Arrester Diagnostic Type in a Distribution Line (배전선로용 피뢰기 진단형 누설전류 검출장치 설계)

  • Yoon, Gi-Gab;Park, Jong-Beom;Yoon, Suk-Mu;Lee, Seung-Hak;Kim, Hong-Pil;Kim, Kwang-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.501-503
    • /
    • 2000
  • Since an arrester has been generally used at the distribution line and abroad for the protection of electrical equipments against overvoltage (or abnormal surge) taking place in or from an electrical system, a fault, especially, in the distribution line is very likely to result in the destruction of insulation of other protection devices to cause an overall paralysis of a power system, a chaos. Considering the importance of arresters, its earlier replacement than its proposed life cycle causes an economical loss, and a negligence not to replace or repair it in time gives rise to a crucial accidence. The purpose of this paper is to invent an electric leakage current detector and to solve such problems by the continuous and regular inspection of an arrester.

  • PDF

A Study on Remodeling Period by Cost Analysis of Finished and Equipped Materials in Apartment Building (공동주택 내/외장재 및 설비재의 비용분석을 통한 리모델링시기 검토를 위한 연구)

  • Oh Jin-Soo;Kim Ki-Hyung;Lee Myung-Sik
    • Korean Institute of Interior Design Journal
    • /
    • v.14 no.5 s.52
    • /
    • pp.218-225
    • /
    • 2005
  • In this apartment market, many apartments are being reconstructed within even less than 20 years from their first construction. This entails many problems in environmental and economical facets, for which many researches are under way in several institutions and universities. International cases show that the international trend goes for remodeling of maintenance, management, and repairing rather than new building. The purpose of this study is to investigate the factors of cost evaluation for establishing the time period of apartment based on durability of material and equipment while considering the economic feasibility of apartment, when remodeling as a concept of sustainability regarding building is being vitalized. This study investigates the proper period of remodeling in consideration of weight accruing to the LC(Life Cycle) and cost based on the standardized durability. The weight of cost, period establishment analysis, and LC according durability varies the data values of remodeling periods. The physical durability and cost from this data enable the investigation into not only the repair period of individual materials of the apartment but also remodeling period.

Experimental and numerical investigation on gas turbine blade with the application of thermal barrier coatings

  • Aabid, Abdul;Jyothi, Jyothi;Zayan, Jalal Mohammed;Khan, Sher Afghan
    • Advances in materials Research
    • /
    • v.8 no.4
    • /
    • pp.275-293
    • /
    • 2019
  • The engine parts material used in gas turbines (GTs) should be resistant to high-temperature variations. Thermal barrier coatings (TBCs) for gas turbine blades are found to have a significant effect on prolonging the life cycle of turbine blades by providing additional heat resistance. This work is to study the performance of TBCs on the high-temperature environment of the turbine blades. It is understood that this coating will increase the lifecycles of blade parts and decrease maintainence and repair costs. Experiments were performed on the gas turbine blade to see the effect of TBCs in different combinations of materials through the air plasma method. Three-layered coatings using materials INCONEL 718 as base coating, NiCoCrAIY as middle coating, and La2Ce2O7 as the top coating was applied. Finite element analysis was performed using a two-dimensional method to optimize the suitable formulation of coatings on the blade. Temperature distributions for different combinations of coatings layers with different materials and thickness were studied. Additionally, three-dimensional thermal stress analysis was performed on the blade with a commercial code. Results on the effect of TBCs shows a significant improvement in thermal resistance compared to the uncoated gas turbine blade.

Fiber optic smart monitoring of concrete beam retrofitted by composite patches

  • Kim, Ki-Soo;Chung, Chul;Lee, Ho-Joon;Kang, Young-Goo;Kim, Hong
    • Structural Engineering and Mechanics
    • /
    • v.17 no.3_4
    • /
    • pp.347-356
    • /
    • 2004
  • In order to extend the lifetime of buildings and civil infrastructure, patch type fibrous composite retrofitting materials are widely used. Retrofitted concrete columns and beams gain stiffness and strength, but lose toughness and show brittle failure. Usually, the cracks in concrete structures are visible to the naked eye and the status of the structure in the life cycle is estimated through visual inspections. After retrofitting of the structure, crack visibility is blocked by retrofitted composite materials. Therefore, structural monitoring after retrofitting is indispensable and self diagnosis method with optical fiber sensors is very useful. In this paper, we try to detect the peel out effect and find the strain difference between the main structure and retrofitting patch material when they separate from each other. In the experiment, two fiber optic Bragg grating sensors are applied to the main concrete structure and the patching material separately at the same position. The sensors show coincident behaviors at the initial loading, but different behaviors after a certain load. The test results show the possibility of optical fiber sensor monitoring of beam structures retrofitted by the composite patches.

Mechanism for Antioxidant Activity of Nardostachys chinensis root Extract

  • Heo, Jee-In;Kim, Jeong-Hyeon;Lee, Jeong-Min;Kim, Sung Chan;Park, Jae-Bong;Kim, Jaebong;Lee, Jae-Yong
    • Journal of Applied Biological Chemistry
    • /
    • v.57 no.1
    • /
    • pp.17-22
    • /
    • 2014
  • Nardostachys chinensis (N. chinensis) has been used in traditional medicine as a sedative and analgesic. It has been reported that N. chinensis extract has an antioxidant activity. However, the mechanism has not been elucidated. In this study, we showed that FOXO3a was activated by N. chinensis extract. FOXO3a is a transcriptional factor that involved in cell cycle arrest, DNA repair, apoptosis, and detoxification of reactive oxygen spices (ROS). Protein level of FOXO3a was increased by N. chinensis extract whereas phospho-FOXO3a (Thr 32) was not changed. Promoter activities of target genes of FOXO3a such as MnSOD, p27, and GADD45 were increased by N. chinensis extract. Among target genes, protein level of MnSOD was increased by N. chinensis extract, and this leads to removal of ROS level in human embryonic fibroblast (HEF) cells. These results suggested that N. chinensis extract has an antioxidant activity by upregulation of MnSOD through FOXO3a activation.

Clinical Experiences of Congenital Diaphragmatic Anomaly (선천성 횡경막 이상증의 임상적 경험)

  • Hyeon, Myeong-Seop;Im, Seung-Gyun;Jeong, Gwang-Jin
    • Journal of Chest Surgery
    • /
    • v.28 no.4
    • /
    • pp.381-386
    • /
    • 1995
  • In our hospital we have seen 20 cases of congenital diaphragmatic anomalies from June 1984 until December 1993. These were classified into 10 cases of diaphragmatic eventration, 8 cases of Bochdalek hernia, 1 case of Morgagni hernia, and 1 case of esophageal hiatal hernia. Diaphragmatic eventration cases were composed of 8 males and 2 females with ages varing from 3 hour to 42 year. They were discovered by symptoms: 5 cases of respiratory insufficiency; 3 cases of frequent respiratory infection; and 2 cases by chance; 6 cases involved the left side, 4 cases involved right side. Emergency operations were done to 4 patients. Among the 10 patients, only one operative mortality occurred; 3 hour old female.Bochdalek hernia cases composed 6 females and 2 males, 5 patients were less than 6 hour old. All patients were operated on an emergency status and three of them expired due to the vicious cycle of pulmonary hypertension and pulmonary vasoconstriction, persistent fetal circulation, hypoxia, and metabolic acidosis. Morgagni hernia was seen in one 69 year old female patient, she had no complaint of symptoms and was incidentally detected. Hernia was repaired through right thoracotomy. She was discharged with healthy appearence. Esophageal hiatal hernia was seen in a 10 month old male patient, his symptoms were persistent vomiting and coughing since birth. Sliding type of esophageal hiatal hernia repair was completed through left thoracotomy.

  • PDF

Application of Dynamic Reliability Model to Analysis of Armor Stability of Rouble-Mound Breakwaters (경사제 피복재의 안정성 해석에 대한 동적 신뢰성 모형의 적용)

  • Kim, Sung-Ho;Lee, Cheol-Eung
    • Journal of Industrial Technology
    • /
    • v.24 no.A
    • /
    • pp.215-226
    • /
    • 2004
  • A dynamic reliability model which can take into account the time history of loading sequences may be applied to the analyses of the hydraulic stability of armor units on rubble-mound breakwaters. All the parameters related to the stability of structures have been considered to be constants in the deterministic model until now. Thus, it is impossible to study the effects of some uncertainties of the related random variables on the stability of structures. In this paper, the dynamic reliability model can be developed by POT(Peak Over Threshold) method in order to take into account the time history of loading sequences and to investigate the temporal behaviors of stability of structure with its loading history. Finally, it is confirmed that the results of dynamic reliability model agree with straight- forwardly those of AFDA(Approximate Full Distribution Approach) of the static reliability model for the same input conditions. In addition, the temporal behaviors of probability of failure can be studied by the dynamic reliability model developed to analyze the hydraulic stability of armor units on rubble-mound breakwaters. Therefore, the present results may be useful for the management of repair and maintenance over the whole life cycle of structure.

  • PDF

Life Cycle Costing: Maintenance and Repair Costs of Hospital Facilities Using Monte Carlo Simulation

  • Kim, Tae-Hui;Choi, Jong-Soo;Park, Young Jun;Son, Kiyoung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.13 no.6
    • /
    • pp.541-548
    • /
    • 2013
  • During the administration of a construction project, various types of participants are engaged in the project. From the design phase to the maintenance phase, these participants may confront many risks. To avoid these risks, participants should utilize an insurance company or a bond company. The types of risks and liability that a construction manager may face are listed in the construction law or contract. But there are some arguments related to risk transferring and the content of risks. For this reason, construction managers must carefully consider any possible risks in the contract and the construction law. Therefore, for construction managers to deal with risks appropriately, the introduction of a legal requirement to carry professional liability insurance, a defined compensation range for damages, a method of guarantee in the event of defects, a defined compensation claim period for damage, and a method of damage claim were suggested in this study.

Study on the Development of Maintenance Process in Long-Life Housing - Focus on the Development of Maintenance Process for the Manager - (장수명공동주택의 유지관리업무프로세스 구축에 관한 연구 - 관리자를 위한 유지관리업무프로세스를 중심으로 -)

  • Ji, Jang-Hun;Kim, Soo-Am;Yoon, Sang-Cho
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2009.04a
    • /
    • pp.344-349
    • /
    • 2009
  • To be Low Carbon and Green Growth, it is necessary that Long-Life Housing based on Green Technology is supplied. The main concern at the moment is developing Sustainable Housing relative to Life-Cycle or Life-Style of the residents, and the resident of Remodeling or Redevelopment. This study is aim to be Development of Maintenance Process in order to make steady dwelling when supplying Long-Life Housing that separates Support(Skeleton) and Infill different from the existing Short-Life Housing, and has durability, alterability, available remodeling, easy maintenance. Long-Life Housing should consider the maintenance about movement and variableness. In contrast, the maintenance of the existing Housing is regular maintenance, change and repair by damage. As well as Long-Life Housing should be demanded proper Development of Maintenance Process because of difference of Housing in concept, design and Construction. Therefore, this study looks into problems when applying Development of Maintenance Process in Long-Life Housing, and shows Development of Maintenance Process about the efficient Long-Life Housing for the manager.

  • PDF

Integrity Evaluation for Stud Female Threads on Pressure Vessel according to ASME Code using FEM (유한요소해석에 의한 ASME Code 적용 압력용기 스터드 암나사산의 건전성 평가)

  • Kim, Moon-Young;Chung, Nam-Yong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.6
    • /
    • pp.930-937
    • /
    • 2003
  • The extension of design life among power plants is increasingly becoming a world-wide trend. Kori #1 unit in Korea is operating two cycle. It has two man-ways for tube inspection in a steam generator which is one of the important components in a nuclear power plant. Especially, stud bolts fur man-way cover have damaged by disassembly and assembly several times and degradation for bolt materials for long term operation. It should be evaluated and compared by ASME Code criteria for integrity evaluation. Integrity evaluation criteria which has been made by the manufacturer is not applied on the stud bolts of nuclear pressure vessels directly because it is controlled by the yield stress of ASME Code. It can apply evaluation criteria through FEM analysis to damaged female threads and to evaluated safety fer helical-coil method which is used according to Code Case-N-496-1. From analysis results, we found .that it is the same results between stress intensity which got from FEM analysis on damaged female threads over 10% by manufacture integrity criteria and 2/3 yield strength criteria on ASME Code. It was also confirmed that the helical-coil repair method would be safe.