• 제목/요약/키워드: removal times

Search Result 1,397, Processing Time 0.023 seconds

Improvement of bacteria for removing of phosphate by spheroplast fusion (원형질체 융합에 의한 인산염 제거균주의 개량)

  • 윤성녀;조경주;조홍범;최영길
    • Korean Journal of Microbiology
    • /
    • v.29 no.2
    • /
    • pp.117-122
    • /
    • 1991
  • In order to improve the removal ability of phosphate, Spheroplast fusions were performed among auxotrophic mutants of Aeromonas hydrophila isolated from waste water, named A13 and A14, Aci37 auxotrophic mutant of Acinetobactercalcoaceticus, and auxotrophic E. coli HR262/pCE27 carring pit gene. Eight fusants obtained from this experiment showed different biochemical characteristics. When the rate of phosphate uptake among fusants (F1-F8) was investigated in Phosphate Uptake Medium (PUM), F8 strain showed the highest rate for phosphate removal, 7 times as much as control after two hours incubation. The role of cations ($Mg^{++}$ ,$Ca^{++}$ , $K^{+}$ in phosphate uptade by F8 was also investigated in PUM without each salt. $K^{+}$ seemed to be crucial. Being compared with phosphate untake rate in PUM, that in PUM without $K^{+}$ was reduced 1.5 times. Therefore, by applying F8 strain and $K^{+}$ in practical environmental system, the increased efficiency in phosphate removal can be derived.

  • PDF

Removal of OH Spectral Interferences from Aqueous Solvents in Inductively Coupled Plasma-Atomic Emission Spectrometry (ICP-AES) with Ar Cryogenic Desolvation

  • Cho, Young-Min;Pak, Yong-Nam
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.9
    • /
    • pp.1415-1420
    • /
    • 2005
  • The spectral interferences of OH from aqueous solvents in ICP-AES have been studied and eliminated using a cryogenic argon trap. The prominent lines of Bi I 306.772 nm, Al I 309.271 nm, and V II 310.230 nm, which are very seriously overlapped with the OH band, were examined. With an extended torch and high tangential flow of 20 L/min, water vapor from air entrainment was prevented. The combination of a condenser and argon cryogenic trap was able to eliminated most of water vapor carried by the argon sample gas. Removal of OH spectral interference could extend the linearity of the calibration curve 5-10 times on the lower concentration for ICP-AES. Interference Equivalent Concentration (IEC) has been reduced to 5.6, 5.9, and 12.4 times for Bi, Al and V, respectively.

A Study on Smoke Movement by Using Large Eddy Simulation I. Smoke Control Systems and Extraction Flowrate (대와류모사를 이용한 연기이동의 연구 I. 제연방식과 배기풍량)

  • 박외철
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.2
    • /
    • pp.40-45
    • /
    • 2003
  • To evaluate the smoke control systems, the large eddy simulation turbulence model based Fire Dynamics Simulate was applied to a 2m $\times$ 2m $\times$ 2.4m room with an opening. The smoke removal rate was investigated for three different smoke control systems: ventilation, extraction and pressurization. When the opening was closed, the smoke removal rates of the smoke control systems were almost the same as expected. The pressurization system showed a lower smoke removal rate compared with the other two smoke control systems for the room with the opening, and hence the pressurization system might not be efficient for a place with large openings. It was shown that the lower extraction flowrate is, the longer time the ventilation system requires to remove smoke. From these results, the ventilation system is recommended for subway stations where several large openings exist.

Shoot Cutting Effects on the Productivity and Nutrient Removal of Some Wetland Plants (습지식물의 지상부 제거가 생산력과 영양염류 제거량에 미치는 효과)

  • 정연숙;오현경;노찬호;황길순
    • Korean Journal of Environmental Biology
    • /
    • v.17 no.4
    • /
    • pp.459-465
    • /
    • 1999
  • This work focused on the effects of the timing and the frequency of shoot cutting to maximize the productivity and the nutrient removal of three emergent macrophytes, Phragmites communis, Zizania latifolia and Typha angustifolia in natural wetlands. Shoot cutting significantly enhanced biomass production and resulted in more nitrogen and phosphorus removal from water in these three experimental species, compared to those of control. However, the frequency and the timing of shoot cutting, and the enhancement ratio were different among three species. For Phragmites stands, the highest productivity was 1.9 times of control in June treatment of the first year experiment, while 1.3 times in May treatment of the second year experiment. Zizania and Typha stands were both 1.2 times of control in August treatment and June and August treatment. Calculating the total annual removal rate of nitrogen and phosphorus based on the highest productivities among treatments, in Phragmites stands, 2.0 times of nitrogen and 1.8 times of phosphorus were removed in the first year, and both 1.4 times in the second year experiment. Likewise, for nitrogen and phosphorus; 2.4 and L.8 times in Zizania stands, and 1.8 and 1.9 times in Typha stands were removed. Overall, these results suggested that cutting treatment of shoots be effective. Thus, shoot cutting of two times during a growing season were recommended to maximize the effects: that is, in May or June, and October for Phragmites stands, and in August and October fur Zizania and Typha stands.

  • PDF

Removing High Concentration Nitrogen by Electrolysis (전기분해에 의한 고농도 질소 제거의 특성)

  • Gil, Dae-Soo;Lee, Byung-Hun;Choi, Hae-Kyoung;Kwon, Dong-Min
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.2
    • /
    • pp.265-277
    • /
    • 2000
  • Laboratory experiments were conducted to investigate characteristics for removing ammonia-nitrogens by electrolysis methods. A stainless steel plate is used as the cathode and either $IrO_2{\backslash}Ti$ plate serves as the anode. Experiments were conducted to examine the effects of the operating conditions, such as the current density, retention time, electrode gap, $Cl^-/NH_4{^+}-N$ on the $NH_4{^+}-N$ removal efficiency. Possible optimum range for these operating variables are experimentally determined. The $NH_4{^+}-N$ removal efficiencies between plate type anode and net type anode were about same effect, but electrolytic power using net type anode is low than plate type anode. The $Cl^-/NH_4{^+}-N$ ratio was about $20.0kgCl^-/kgNH_4{^+}-N$ when $NH_4{^+}-N$ removal obtained 73 %, $Cl^-/NH_4{^+}-N$ ratio needs $27.6kgCl^-/kgNH_4{^+}-N$ so as to $NH_4{^+}-N$ completely remove. The removal efficiency of $NH_4{^+}-N$ increase with current density, retention time and $Cl^-/NH_4{^+}-N$ ratio, but decreased with increasing electrode gap. The relationship of operating conditions and $NH_4{^+}-N$ removal efficiencies are $$NH_4{^+}-N_{re}(%)=14.5364(Current\;density)^{0.7093}{\times}(HRT)^{1.0060}{\times}(Gap)^{-0.9926}{\times}(Cl^-/NH_4{^+}-N)^{1.0024}$$ With adding COD or/and alkalinity, relationships are $$NH_4{^+}-N_{re}(%)=9.8408(Current\;density)^{0.6232}{\times}(HRT)^{1.0534}$$ There existed a competition between the removals for $NH_4{^+}-N$ and $COD_{Cr}$ during electrolysis, the removal of $NH_4{^+}-N$ was shown to be dominant. $NH_4{^+}-N$ removal was high as addition of glucose and alkalinity.

  • PDF

Treatment Characteristics of Paper-mill Wastewater Using Pure Oxygen Activated Sludge Process (순산소 활성오니 공정을 이용한 제지폐수의 처리특성)

  • Kim, Sung Soon;Chung, Tai Hak
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.13 no.4
    • /
    • pp.27-34
    • /
    • 1999
  • An experimental study on improvement of the paper-mill wastewater treatment using the pure oxygen activated sludge process was conducted. The effects of hydraulic retention time(HRT) and BOD loading on organic removal efficiency were investigated. The BOD removal efficiencies were above 90% under all examined HRTs except for HRT of 3 hours. The increase of HRT from 3 hours to 6 hours, and to 12 hours significantly improved BOD and COD removal efficiencies, respectively. However, additional increase of HRT did not affect organic removal efficiency. F/M ratio change at fixed HRT did not affect organic removal efficiency. However, F/M ratio investigated in this study(0.11~1.98kgBOD/kgMLVSS/day) was 5 times greater in maximum than that of conventional activated sludge process, which implies that pure oxygen activated sludge process can treat wastewater with high organic strength. Under the same HRT, the volumetric BOD loading change cause no effect on organic removal efficiency also.

  • PDF

Factors Influencing the Removal of Nutrient by Seawater (해수에 의한 영양염 제거에 있어서 영향인자의 평가)

  • Cortes, Aiza;Kim, Woo-Hang
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2009.06a
    • /
    • pp.145-147
    • /
    • 2009
  • Nutrients in wastewater should be removed prior to release in the receiving waters to prevent the occurrence of eutrophication. In this study, seawater is used to remove ammonia and phosphate by the formation of struvite ($MgNH_{4}PO_{4}{\cdot}6H_{2}O$). It aims to know the optimum conditions for the removal of nutrients using seawater as source of magnesium ions. Experiments were performed using jar tester and pH of ammonium-phosphate solutions were adjusted Samples were drawn at different mixing times. It was shown that simultaneous removal of ammonia and phosphate is rapid, with no significant reduction beyond 10 min of mixing Another important parameter is pH, where range 10-11 showed the optimum nutrient removal. Increase in the volume of seawater, which meant an increase in magnesium ions also lead to better removal.

  • PDF

Synthesis of Removal Agent and Developement of Treatment Technology on Copper (효과적인 구리 제거제 합성 및 처리 기술 개발에 관하여)

  • Cho, Byeung-Rak
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.16 no.2
    • /
    • pp.35-39
    • /
    • 2013
  • This paper synthesized the new copper removal agent(PW-2001) and investigated removal efficiency of copper, COD, calcium, SS and sludge amounts. Removal efficiency of copper were 96.1% and 99.1% with the lime and PW-2001, respectively while COD removals reached up to 38% and 69.6% with the use of lime and PW-2001. The concentrations of calcium and SS with PW-2001 were decreased 2.68 and 4.95 times lower than those with lime. Amount of sludge with PW-2001 was 60% smaller than lime. Quantity of PW-2001 needed for coagulation only reached 58.7, compared to lime standard quantity(100), and total cost of copper removal with PW-2001 was saved 25% more than lime.

A Study on Fluid Dynamics for Effect of Agitation Velocity on Nutrients Removal in High Rate Algae Stabilization Pond (고율 조류 안정화지에서 교반속도가 영양염류 제거에 미치는 영향에 관한 유체동역학적 연구)

  • 공석기
    • Journal of Environmental Science International
    • /
    • v.10 no.1
    • /
    • pp.65-71
    • /
    • 2001
  • HRP(high rate pond) which had kept the manufactured clay of 3cm-thickness as benthic clay in reactor and the 6 flat-blade turbine as impeller for agitation was named HRASP(high rate algae stabilization pond). And the experiment for treatment of artificial synthesis wastewater containing COD :300mg/$\ell$, NH$_3$-N : 300mg/$\ell$, T-P : 9mg/$\ell$ as nutrients was been performed successfully. This reactor was been operated under conditions : 24hrs.-irradiation and water temperature, $25^{\circ}C$ and pH 7 and agitation velocity, 15, 30, 45rpm and the effect of agitation velocity on algal bioaccumulation of nutrients was been studied with view point of fluid dynamics. The next followings could be obtained as results. 1. The agitation with a turbine impeller blade in HRASP makes clay particle indicate superior suspension effect by means of forming of excellent curl/shear flow in reactor. 2. The excessive suspension of clay particle which is created at 45rpm as rotation velocity of impeller blade of turbine disturbs the light penetration and algal photosynthesis reaction. 3. Efficiencies for removal of nutrients come out as COD : 93.9%~94.3%, ($NH_3-N + NO_3-N$) : 81.9%~99.0%, T-P : 46.8%~53.6%. 4. Kuo values of $K_1$for algal growth come out seperately as 15rpm : $1.876{\times}10^{-2}, 30rpm : 4.618{\times}10^{-3}$. 5. Kuo values of $K_2$for removal of N, P come out seperately as 15rpm : $8.403{\times}10^{-1}$ and $1.397{\times}10^{-1}$, 30rpm : $4.823{\times}10^{-1} and 2.052{\times}10^{-1}$. 6. It can be guessed easily that the excessive agitation can inhibit the algal and bacterial symbiotic reaction if it is considered that micro organism\` sense to preservation of life is relied on natural function of metabolism. Therefore the studies for this matter should be followed continuously.

  • PDF

A Study on the Reduction Process of VOCs Emission from Paint Booth - A Hybrid Process of Biotrickling Filter and Activated Sludge Reactor

  • Lim Gye-Gyu
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.E2
    • /
    • pp.41-48
    • /
    • 2005
  • A novel hybrid system composed of a biotrickling filter and an activated sludge reactor was investigated under the conditions of four different SRTs (sludge retention times). The performance of the hybrid reactor was found to be directly comparable among the four different sludge ages. Discernible differences in the removal performance were observed among four different SRTs of 2, 4, 6, and 8 days. High removal efficiency was achieved by continuous circulation of activated sludge over the immobilized mixture culture, which allowed on pH control, addition of nutrients, and removal of paint VOCs (volatile organic compounds). The results also showed that the removal efficiency for a given pollutant depends on the activity of microorganisms based on the SRT. As the SRT increased gradually from 2 to 8 days, the average removal performance decreased. The highest removal rate was achieved at the SRT of 2 days at which the highest OUR (oxygen uptake rate), $6.1mg-O_2/liter-min$ was measured. Biological activity in the recycle microbes decreased to a much lower level, $3.6mg-O_2/liter-min$ at a SRT of 8 days. It is thus believed that young microorganisms were more active and more efficient for the VOCs removal of low concentrations and high flow rates. The apparent correlation of $R^2=0.996$ between the average removal efficiency and the average OUR at each SRTs suggests that VOCs degradation by young cells significantly affected the overall removal efficiency for the tested SRTs.