• Title/Summary/Keyword: removal efficiencies

Search Result 1,115, Processing Time 0.024 seconds

Effect of Coagulant addition on Nutrient Removal Efficiency in a Submerged Membrane Bioreactor (응집제의 첨가에 따른 Membrane bioreactor 의 고도처리 효율 연구)

  • Park, Jong-Bu
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.2
    • /
    • pp.235-241
    • /
    • 2011
  • This study was performed to investigate the characteristics of nutrient removal of municipal wastewater in the submerged membrane bioreactor by addition of alum directly into aerobic tank. Membrane bioreactor consists of three reactors such as two intermittent anaerobic tanks and the aerobic tank with hollow fiber membrane. The removal efficiencies of $COD_{cr}$, BOD, SS, TN and TP on the membrane bioreactor were 94.0%, 99.1%, 99.9%, 66.9%, and 58.9%, respectively. In addition, The removal efficiencies of $COD_{cr}$, BOD, SS, TN and TP on the membrane bioreactor with alum addition were 93.4%, 99.0%, 99.9%, 63.2%, and 96.8%, respectively. There was little difference between them on the nutrient removal efficiencies except phophorus removal. The estimated sludge production, specific denitrification rate, specific nitrification rate and phosphorus removal content on the membrane bioreactor were 1.76 kgTSS/d, $0.055mgNO_3-N/mgVSS{\cdot}d$, $0.031mgNH_4-N/mgVSS{\cdot}d$, and 0.095 kgP/d, respectively. And The estimated sludge production, specific denitrification rate, specific nitrification rate and phosphorus removal content on the membrane bioreactor with alum addition were 2.90 kgTSS/d, $0.049mgNO_3-N/mgVSS{\cdot}d$, $0.030mgNH_4-N/mgVSS{\cdot}d$, and 0.160 kgP/d, respectively. The alum content added was 1.7 molAl/molP on an average. The increasing ratio of tran-membrane pressure on the membrane bioreactor was $0.0056kgf/cm^2{\cdot}compared$ to $0.0033kgf/cm^2{\cdot}d$ on the membrane bioreactor with alum addition. There was a slightly reduction effect on membrane fouling by alum addition.

Evaluation of Removal Efficiencies of Micropollutants in Wastewater Treatment Plants (산업폐수처리장에서의 미량유해물질 제거율 평가)

  • Lee, In-Seok;Sim, Won-Jin;Oh, Jeong-Eun;Kim, Chang-Won;Chang, Yoon-Seok;Yoon, Young-Sam
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.2
    • /
    • pp.214-219
    • /
    • 2007
  • 66 micropollutants analyses in 9 wastewater treatment plants(WWTPs) along Nak-dong river were implemented to identify the concentrations and removal efficiencies before and after treatment processes. As a result of study, the concentration levels discharged from WWTP effluents to water system were below the water quality criteria and the levels of other studies. The removal efficiencies were 84.6%(DAF/CCR) and 81.6%(AC) for 1,4-dioxane. Phenol, Clphs and PAHs were removed 94.6%, 66.4% and 80.6% respectively by the activated sludge(AS) process. The removal efficiencies of Clbzs were 45.3% for the activated sludge(AS) process and 60.6% for the activated carbon(AC) process. However, other processes besides AS and AC, the removal efficiencies of Clbzs were very low(<20%). The sand filtration(SF) process that could remove particle matters showed the best efficiency for PCDDs / Fs removal$(\geq99%)$. However, in case of relatively low PCDDs/Fs concentration level in influent, the removal efficiency was not so high$(\leq50%)$.

Feasibility Study of a Shipboard Sewage Treatment Plant (Sequencing Batch Reactor and Membrane Bioreactor) in Accordance with MARPOL 73/78, Focusing Mostly on Nutrients (T-N and T-P) (MARPOL 73/78의 기준에 따른 선박오수 처리 장치(SBR 및 MBR 복합공정)의 사용 가능성 평가 : 영양염류 위주 (T-N 및 T-P))

  • Jung, Jin-Hee;Youn, Young-Nae;Choi, Young-Ik
    • Journal of Environmental Science International
    • /
    • v.25 no.9
    • /
    • pp.1233-1239
    • /
    • 2016
  • This study aimed to evaluate changes in the TN and TP removal efficiencies, depending on whether or not a settling process is applied, in a sequencing batch reactor (SBR) process with a membrane bioreactor (MBR). Nutrient removal was considered in terms of developing an advanced water treatment system for ships in accordance with water quality standards set forth by 227(64). For these purposes, the TN and TP concentrations in the inflow and outflow water were measured to calculate the TN and TP removal efficiencies, depending on whether or not a settling process was used. Water discharged from a bathroom, which was constructed for the experiment, was used as the raw water. The experiment that included a settling process was conducted twice, and the operating conditions were: aeration for 90 min, settling for 30 min, agitation for 15 min, and settling for 15 min for one experiment; and aeration for 150 min, settling for 45 min, agitation for 15 min, and settling for 15 min in the other. Operating conditions for the experiment that did not include a settling process were: aeration for 180 min and agitation for 60 min. The concentration of the mixed liquor suspended solids (MLSS) in the reactor was 3,500 mg/L, while the aeration rate was 121 L/min and the water production rate was 1.5 L/min. For the two experiments where a settling process was applied, the average TN removal efficiencies were 44.39% and 41.05%, and the average TP removal efficiencies were 47.85% and 46.04%. For the experiment in which a settling process was not applied, the average TN removal efficiency was 65.51%, and the average TP removal efficiency was 52.51%. Although the final nutrient levels did not satisfy the water quality standards of MEPC 227(64), the TN and TP removal efficiencies were higher when a settling process was not applied.

Evaluation of effective process for oxidation and coagulation by ferrous ion and hydrogen peroxide

  • Moon, H.J.;Kim, Y.M.;Lee, S.H.
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2003.11b
    • /
    • pp.319-321
    • /
    • 2003
  • This research was carried out to evaluate the removal efficiencies of CODcr and colour for the dyeing wastewater by ferrous solution in Fenton process. The results showed that COD was mainly removed by Fenton coagulation, where the ferric ions are formed in the initial step of Fenton reaction. On the other hand colour was removed by Fenton oxidation rather than Fenton coagulation. The removal mechanism of CODcr and colour was mainly coagulation by ferrous ion, ferric ion and Fenton oxidation. The removal efficiencies were dependent on the ferric ion amount at the beginning of the reaction. However the final removal efficiency of COD and colour was in the order of Fenton oxidation, ferric ion coagulation and ferrous ion coagulation. The reason of the highest removal efficiency by Fenton oxidation can be explained by the chain reactions with ferrous solution, ferric ion and hydrogen peroxide.

  • PDF

Nutrient removal from secondary effluent using filamentous algae in raceway ponds

  • Min, Kyung-Jin;Lee, Jongkeun;Cha, Ho-Young;Park, Ki Young
    • Membrane and Water Treatment
    • /
    • v.10 no.3
    • /
    • pp.191-199
    • /
    • 2019
  • In this study, we investigated the cultivation possibility using Hydrodictyon reticulatum in a continuous raceway pond as a tertiary sewage treatment plant. The cultivation possibility was evaluated by varying the light quantity, wavelength, and hydraulic retention time (HRT). Experimental results showed that the growth rates of algae and the removal efficiencies of nutrients increased as the light quantity increased, and the maximum photosynthetic rate was maintained at $100{\mu}mol/m^2{\cdot}s$ or higher. When wavelength was varied, nutrient removal efficiency and growth rate increased in the following order: green light, red light, white light, and blue light. The nutrient removal efficiencies and algae productivity in HRT 4 d were better than in HRT 8 d. We conclude that if Hydrodictyon reticulatum is cultivated in a raceway pond and used as a tertiary treatment facility in a sewage treatment plant, nutrients can be effectively removed, and production costs can be reduced.

Effects of the Variation of Aeration Time in Sequencing Batch Reactor (SBR) (1) - Nutrient Removal (Sequencing Batch Reactor (SBR)에서 포기시간 변경에 따른 영향 (1) - 영양염류 제거)

  • Jeong, No-Sung;Park, Young-Seek;Kim, Dong-Seog
    • Journal of Environmental Science International
    • /
    • v.20 no.1
    • /
    • pp.35-47
    • /
    • 2011
  • The effect of the variation of aeration time on the removal of organics, nitrogen and phosphorus using synthetic wastewater was investigated in sequencing batch reactors (SBRs) which included DNPAOs and DNGAOs. The cycling times in four SBRs were adjusted to 12 hours and then included different aerobic times as 1 hr, 2.5 hr, 4 hr and 5.5 hr, respectively. Four SBR systems have been operated and investigated for over 40 days. Average TOC removal efficiencies were about 71 % in all SBRs. The $NH_4^+$-N removal efficiency was increased as the increase of aeration time. After changing aeration time, the total nitrogen removal efficiencies of SBRs were shown as 35 %, 85 %, 75 % and 65 %, respectively. Higher phosphorus release and uptake were occurred as the decrease of the aeration time. After all, the overall phosphorus removal efficiency decreased and the deterioration of phosphorus removal was occurred when aeration time was over 4 hr. Denitrification in aerobic conditions was observed, which showed the presence of DNPAOs and DNGAOs. In batch experiments, PAOs were shown as the most important microorganisms for the phosphorus removal in this experiment, and the role of DNGAOs was higher than that of DNAPOs for the nitrogen removal.

Immobilization of Earthworm Casts to Treat the Waste Sludge Produced from Pulp & Paper Plants as a Biocarrier (제지공정 페슬러지처리용 지렁이 분변토의 담체화 기술)

  • Cho, Wook Sang;Lee, Eun Young;Cho, Nam Hyeuk
    • Clean Technology
    • /
    • v.8 no.3
    • /
    • pp.167-172
    • /
    • 2002
  • The adaptability of earthworm casts produced form the waste sludge of pulp and paper plants for a biocarrier used in the advanced wastewater treatment was investigated. Removal efficiencies of nutrients in the activated sludge technology without carrier were compared with those treated with carrier made of casts under the different conditions such as the composition of the input and kinds of carrier. When the waste water was treated in the activated sludge technology without carriers, removal efficiencies of T-P and T-N were average values of 31% and 52%, respectively. On the contrary, pellet type carrier and pack type carrier increased the removal efficiencies of T-P and T-N by 1.3~1.4 and 1.9~2.0 times, respectively. At the same time, the high removal of T-P and T-N were observed irrespective of the types of carrier in which many kinds of microorganisms were grown. The difference in the removal efficiencies of BOD and COD between the treatment with and without carrier was negligible. According to this research, the carrier made of casts was thought to be highly applicable in the advanced wastewater treatment.

  • PDF

Proteomic Analysis of Diesel Oil Biodegradation by Bacillus sp. with High Phosphorus Removal Capacity Isolated from Industrial Wastewater

  • Hee-Jung Kim;Deok-Won Kim;Jin-Hyeok Moon;Ji-Su Park;Eun-Ji Oh;Jin Yoo;Deok-Hyun Kim;Sun-Hwa Park;Keun-Yook Chung
    • Applied Chemistry for Engineering
    • /
    • v.34 no.6
    • /
    • pp.649-659
    • /
    • 2023
  • This study was initiated to evaluate the phosphorus (P) removal and diesel oil degradation by bacteria isolated from industrial wastewater. The bacteria isolated were identified as Bacillus sp. The P removal efficiencies by Bacillus sp. were 99% at the initial 20 mg/L P concentration. The diesel degradation efficiencies by Bacillus sp. were 86.4% at an initial 1% diesel concentration. Lipophilicity by bacteria was the highest in the log phase, whereas it was the lowest in the death phase. As the diesel was used as a carbon source, P removal efficiencies by Bacillus sp. were 68%. When glucose, acetate, and a mixture of glucose and acetate as second carbon sources were added, the diesel degradation efficiencies were 69.22%, 65.46%, and 51.46%, respectively. The diesel degradation efficiency was higher in the individual additions of glucose or acetate than in the mixture of glucose and acetate. When P concentration increased from 20 mg/L to 30 mg/L, the diesel degradation efficiency was increased by 7% from 65% to 72%, whereas when P concentration was increased from 30 mg/L to 40 mg/L, there was no increase in diesel degradation. One of the five proteins identified by proteome analysis in the 0.5% diesel-treated samples may be involved in alkane degradation and is known as the cytochrome P450 system. Also, two of the sixteen proteins identified in the 1.5% diesel-treated samples may be implicated in the fatty acid transport system and alcohol dehydrogenation.

Effect of Loading Rate in the Operation of DEPHANOX and Modified-DEPHANOX Processes (유입부하가 DEPHANOX 및 Modified-DEPHANOX 공정에 미치는 영향)

  • Ryu, Hong-Duck;Min, Kyung-Kook;Lee, Sang-Ill
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.1
    • /
    • pp.24-31
    • /
    • 2004
  • This study was initiated to evaluate the efficiencies of DEPHANOX and Modified-DEPHANOX, which were devoloped to enhance nitrogen removal efficiency in municipal wastewater treatment. In the results, removal efficiency of organic matters was not affected much by increased loading rate of organic matters which is contained in influent. The nitrogen removal efficiencies according to the loading rate of influent TN was decreased drastically in conditions of over $0.2kg/m^3{\cdot}day$, which is T-N loading rate, and the DEPHANOX process was affected more sensitively than the M-DEPHANOX was. When the temperature was altered from $25^{\circ}C$ to $16^{\circ}C$ at HRT 6hrs, the removal efficiency of ammonia nitrogen was still over 90% and it was concluded that both DEPHANOX and M-DEPHANOX were strong enough to endure temperature variation. Moreover, both processes showed over 90% in ammonia removal efficiencies in over HRT 5hrs, so it was concluded that they were strong in HRT variation. M-DEPHANOX process showed a higher value than DEPHANOX did in T-N removal efficiency to the extent of 4~21 %, which resulted from differency of denitrification rates and the biosorption efficiency of organic matter in both processes. In the condition of HRT less than 4hrs, concentrations of ammonia nitrogen contained in effluents and nitrification reactors, might be sensitively affected by biosorption efficiency of organic matters in first separation tank. In the effect of effluent nitrate concentration in phosphorus removal, the more effluent nitrate concentration was decreased, the more phosphorus removal efficiency was increased. This result is related to the decrease of concentration of effluent nitrate which resulted from nitrification inhibition by decreased HRT.

Effect of the Organic and Nitrogen Removal and Electricity Production on Changing the External Resistor and the Inflow Loading in the Biocathode Microbial Fuel Cell (생물환원전극 미생물연료전지에서 외부저항 및 유입부하에 따른 유기물 및 질소 제거와 전기생산에 미치는 영향)

  • Kim, Jiyeon;Kim, Byunggoon;Kim, Hongsuck;Yun, Zuwhan
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.5
    • /
    • pp.556-562
    • /
    • 2015
  • In order to remove the organic substances and the nitrate-nitrogen contained in wastewater, some researchers have studied the simultaneous removal of organics and nitrogen by using different biocathode microbial fuel cells (MFCs). The operating conditions for removing the contaminants in the MFCs are the external resistances, HRTs, the concentration of the influent wastewater, and other factors. This study aimed to determine the effect of the external resistors and organic loading rates, from the changing HRT, on the removal of the organics and nitrogen and on the production of electric power using the Denitrification Biocathode - Microbial Fuel Cell (DNB-MFC). As regards the results of the study, the removal efficiencies of $SCOD_{Cr}$ did not show any difference, but the nitrate-nitrogen removal efficiencies were increased by decreasing the external resistance. The maximum denitrification rate achieved was $129.2{\pm}13.54g\;NO_3{^-}-N/m^3/d$ in the external resistance $1{\Omega}$, and the maximum power density was $3,279mW/m^3$ in $10{\Omega}$. When the DNB-MFC was operated with increasing influent organic and nitrate loading by reducing the HRTs, the $NO_3{^-}-N$ removal efficiencies were increased linearly, and the maximum nitrate removal rate was $1,586g\;NO^3{^-}-N/m^3/d$ at HRT 0.6 h.