• Title/Summary/Keyword: reliable control

Search Result 1,902, Processing Time 0.033 seconds

Design Modification of Bearing Walkout of Water Pump by a Finite Element Analysis (유한요소해석을 이용한 워터펌프 베어링돌출 설계 개선)

  • Yang, Chull-Ho;Han, Moon-Sik
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.3
    • /
    • pp.164-169
    • /
    • 2006
  • A systematic methodology has been proposed to establish a reliable design of water pump system. A simplified steady-state dynamic model of water pump system has been developed to study the response of water pump system to the dynamic load mainly due to the run-out and unbalance. Design modifications are needed to strengthen the structural integrity of existing designs. Increasing the natural frequency of system is pursued to prevent a resonance from occurring in the engine excitation range. A computational reliability methodology combined with finite element analysis is used to identify the most significant factor affecting the system performance. This method considered influence of design control parameters for the performance of design. By including control factors to the system model in a systematic way, more reliable design is expected.

A Study on Reliable Control System Using an Additive Redundant Adaptive Controller (가법적 중복적응 제어기를 이용한 신뢰성 제어 시스템에 관한 연구)

  • ;;Zeungnam Bien
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.3
    • /
    • pp.301-311
    • /
    • 1990
  • A multiple controller structure consisting of a typical feedback controller and an additive redundant controller is proposed for enhancing the reliability of the control system. For the case where the main controller is chosen as a pole assignment controller with input/output measurements and the redundant controller as the Model Reference Adaptive Controller (MRAC) whose reference model is the closed-loop combination of the plant and the main controller, it is proven that the tracking error between the command input and plant output converges to zero under failure in one of the controllers or parameter perturbations of the plant, and further that the reliability measured by Mean Time To Failure (MTTF) is greater than that of the system with only a single main controller. A simulation Example is provided to illustrate reliable operation of the proposed control system against the controller failure.

  • PDF

Design and Implementation of Tree-based Reliable Dissemination Multicast Protocol With Differential Control and Key Management (차별 제어와 키 관리 기능을 통한 트리 기반의 신뢰성 있는 멀티캐스트 프로토콜의 설계 및 구현)

  • Kim, Yeong-Jae;Park, Eun-Yong;An, Sang-Jun;Hyeon, Ho-Jae;Han, Seon-Yeong
    • The KIPS Transactions:PartC
    • /
    • v.9C no.2
    • /
    • pp.235-246
    • /
    • 2002
  • While the Internet is suffering from the massive data such as video stream, IP multicast can ease the load of the Internet by enabling one copy of digital information to be received by multiple computers simultaneously. But If multicast is based on UDP, packets are delivered using a best-effort Policy without any reliability, congestion control or flow control. Multicast group members can join or leave a multicast group at will, and multicast uses broadcast mechanism, it's very hard to keep security from unauthorized members. In this paper, we introduce a new reliable multicast protocol TRDMF proper for one-to-many multicast model with reliability, flow control, congestion control and key management.

Effective and Reliable Speed Control of Permanent Magnet DC (PMDC) Motor under Variable Loads

  • Tuna, Murat;Fidan, Can Bulent;Kocabey, Sureyya;Gorgulu, Sertac
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.5
    • /
    • pp.2170-2178
    • /
    • 2015
  • This paper presents the effective and reliable speed control of PMDC motors under variable loads and reference speeds. As is known DC motors are more preferred in industrial practices. This is that, the PMDC motors don’t require brush and commutator care and to increase in torque per motor depending on developments in power electronics. In this study, proportional-integral controller (PI) and fuzzy logic controller (FL) have been designed for speed control of PMDC motor. In the design of these controllers, characteristics such as minimum overrun time, response time to the load, settling time and ideal rise time have been taken into consideration for better stability performance. In this design, the best system response was searched by examining the effect of different defuzzification methods onto the fuzzy logic system response. In conclusion, it has been seen that FL controller has a better performance for variable speed-load control of PMDC motor compared to PI controller.

Development of the Remote Control System for Liquid Rocket Propulsion System (액체로켓 추진개관 원격제어시스템 개발)

  • 이주열;김재문;김영수;홍일희
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2003.05a
    • /
    • pp.207-210
    • /
    • 2003
  • The purpose of this work is to introduce the Remote Control System for KSR-III Liquid Rocket Propulsion System. We developed the high reliable Fire control System that needed for long distance control. We carried out a real time remote control and measuring for KSR-III lust Liquid Propulsion Rocket in Korea using TCP/IP Ethernet network method and Fiber-optic communication method. Also HMI operation program developed guarantee confidential control, monitoring and analysis for Fire control operation.

  • PDF

Implementation of Internet Based Control by Developing LonWorks Intelligent Control Modules

  • W.P. Hong;Park, W.G.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.70.5-70
    • /
    • 2001
  • This paper proposes a new Internet based control concept & design method and implementation of LonWorks network system for remote intelligent control. The experimental network system using i.LON Web server is designed and fabricated. It is also verified that the developed control modules with LonTalk protocol have available, interoperable, and reliable performance characteristics from the experimental results. Especially, the results provide a available technical data for remote home, building & plant automation control.

  • PDF

System design for simultaneous 2-axis control using custom LSI (전용 LSI를 이용한 2축동시제어 시스템 설계)

  • 강용근;김일환;정광조
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1986.10a
    • /
    • pp.586-591
    • /
    • 1986
  • In this paper, we designed simultaneous 2-axis control system using commercialized custom ICs for positioning and interpolation that is very compact and high reliable. This system is primarily designed for NC system, we verified it is more complete than the other hardware & software based system in its function, control accuracy and cost. Also, this system can be expanded for multi-axis control, it can be applied to the control of more complicated mechanism such as articulated robot.

  • PDF

The Assessing Comparative Study for Statistical Process Control of Software Reliability Model Based on Rayleigh and Burr Type (Rayleigh형과 Burr형 NHPP 소프트웨어 신뢰모형에 관한 통계적 공정관리 접근방법 비교연구)

  • Kim, Hee Cheul
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.10 no.2
    • /
    • pp.1-11
    • /
    • 2014
  • Software reliability in the software development process is an important issue. Software process improvement helps in finishing with reliable software product. In this field, SPC (Statistical process control) is a method of process management through application of statistical analysis, which involves and includes the defining, measuring, controlling, and improving of the processes. The proposed process involves evaluation of the parameter of the mean value function and hence the values of the mean value function at various inter failure times to develop relevant time control chart. In this paper, was proposed a control mechanism, based on time between failures observations using Rayleigh and Burr distribution property, which is based on Non Homogeneous Poisson Process (NHPP). In this study, the proposed model is reliable in terms of hazard function, because it is more efficient in this area can be used as an alternative to the existing model. Through this study, software developers are considered by the various intended functions, prior knowledge of the software to identify failure modes to feed to some extent shall be able to help.

Development of PSCF Model and Determination of Proper Values of Control Parameters (PSCF 모형의 개발과 제어변수의 결정)

  • Cheong, Jang-Pyo;Lee, Seung-Hoon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.1
    • /
    • pp.135-143
    • /
    • 2006
  • The objective of this study is to develop PSCF (potential source contribution function) program and determine the optimal values of control parameters to enhance the prediction of PSCF modeling. This study provides an important information and methodologies that can be used to get better results of locating influencing sources, especially unknown and fugitive sources. To determine proper values of control parameters in PSCF model, the diagnostic assessment on the results obtained by the various input conditions was carried out. PSCF model has created and improved from version 1.0 to version 7.0 since 200 I and the measured data (at least > 100) of receptor, and the values of control input parameters should be arranged and determined to obtain reliable results in PSCF modeling. The size of modeling domain must be determined to include enough trajectories to get reliable results. And the size of grid is recommended to be 2.5 $\sim$ 5 degrees for global scale, 0.2 $\sim$ 1 degrees for regional scale and 0.05 degree for local scale.

The Decision of the Optimal Shape of Inductive Loop for Real-Time Traffic Signal Control (실시간 교통신호제어를 위한 루프 검지기의 최적형태결정에 관한 연구)

  • 오영태;이철기
    • Journal of Korean Society of Transportation
    • /
    • v.13 no.3
    • /
    • pp.67-86
    • /
    • 1995
  • It requires the detector system which can collect highly reliable traffic data in order to perform the real-time traffic signal control. This study is to decide the optimal shape of inductive loop for the real-time traffic signal control .This loop is located at the stopline in the signalized intersection for DS(Degree of Saturation) control. In order to find out the optimal shape of loop, 6types of experiments were performed . The results of the basic experiments of loops are as follows ; -the optimal number of turns for loop is 3 turns. -the impedance values of the loop detectors are similar to that of NEMA standards -the 1.8${\times}$4.5M loop is excellent for sensitivity in actual detection range of car length comparing to other shape of inductive loops. At the experimental of establishments of the optimal loop shape, it found that 1.8 4.5M loop has the highest values of $\DeltaL$ comparing to other types of loops, It means that the range of Lead-in cable length of this loop. And this loop is highly reliable in occpupancy time. Conclusivley, the 1.8${\times}$4.5M inductive loop is the optimal solution as a stop line loop detector for real -time traffic signal control.

  • PDF