• Title/Summary/Keyword: reliability sensitivity

Search Result 730, Processing Time 0.03 seconds

A COMPARISON OF SCANORA$\textregistered$ RADIOGRAPHY WITH WATERS' AND PANORAMIC VIEWS FOR THE DETECTION OF MUCOSAL THICKENING OF MAXILLARY SINUS (워터스, 파노라마 방사선사진과 Scanora$\textregistered$ 방사선사진의 상악동 점막비후 진단 결과의 비교)

  • Yoon Suk-Ja;Jung Hyun-Dae;Kang Byung-Chul
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.25 no.2
    • /
    • pp.389-398
    • /
    • 1995
  • The purpose of this study was to compare the diagnostic performance of Waters' and panoramic view; maxillary sinus posteroanterior and lateral scanography of Scanora/sup (R)/ for mucosal thickening of maxillary sinus as well as to identify the utility of Scanora/sup (R)/ for the detection of maxillary sinus disease. The assessment was done at 66 maxillary sinuses in 45 patients and the results were as follows ; 1. Estimation of presence or absence of mucosal thickening. The sensitivity, specificity, and positive and negative predictive value of maxillary sinus posteroanterior and lateral scanography were 0.865, 0.860, 0.921, and 0.805 respectively and slightly higher than those of Waters' and panoramic views, which were 0.832, 0.835, 0.903, and 0.728 respectively. However, paired t-test showed no significant differences in the diagnostic performance of the two pairs of imaging modalities. 2. Estimation of the types of mucosal thickening. The diagnostic accuracy for type I, II, III was 75.3% on Waters' and panoramic view; 77.9% on maxillary sinus posteroanterior and lateral scanography. It was higher on the latter ,but showed no significant differences from that on the former. 3. Reliability of interpretation. In itraobserver and interobserver agreement, both overall rates of agreement and kappa-value were slightly higher on maxillary sinus posteroanterior and lateral scanography than on Waters' and panoramic views. There was no significant differences between the two pairs of imaging modalities. These results suggested that scanogram is a useful diagnostic radiography as well as Waters' and panoramic views for detection of maxillary sinusitis.

  • PDF

Statistical characteristics of sustained wind environment for a long-span bridge based on long-term field measurement data

  • Ding, Youliang;Zhou, Guangdong;Li, Aiqun;Deng, Yang
    • Wind and Structures
    • /
    • v.17 no.1
    • /
    • pp.43-68
    • /
    • 2013
  • The fluctuating wind induced vibration is one of the most important factors which has been taken into account in the design of long-span bridge due to the low stiffness and low natural frequency. Field measurement characteristics of sustained wind on structure site can provide accurate wind load parameters for wind field simulation and structural wind resistance design. As a suspension bridge with 1490 m main span, the Runyang Suspension Bridge (RSB) has high sensitivity to fluctuating wind. The simultaneous and continuously wind environment field measurement both in mid-span and on tower top is executed from 2005 up to now by the structural health monitoring system installed on this bridge. Based on the recorded data, the wind characteristic parameters, including mean wind speed, wind direction, the turbulence intensity, the gust factors, the turbulence integral length, power spectrum and spatial correlation, are analyzed in detail and the coherence functions of those parameters are evaluated using statistical method in this paper. The results indicate that, the turbulence component of sustain wind is larger than extremely strong winds although its mean wind speed is smaller; the correlation between turbulence parameters is obvious; the power spectrum is special and not accord with the Simiu spectrum and von Karman spectrum. Results obtained in this study can be used to evaluate the long term reliability of the Runyang Suspension Bridge and provide reference values for wind resistant design of other structures in this region.

The Application of the Clinician Administered Posttraumatic Stress Disorder Scale to Identify Combat Related Posttraumatic Stress Disorder (전투 관련 외상 후 스트레스 장애 진단에 있어서 임상가를 위한 외상 후 스트레스 장애 척도의 적용)

  • Kim, Hae Jung;Kim, Tae Yong;Choi, Jin Hee;So, Hyung Seok;Chung, Moon Yong;Kim, Dong Su;Bang, Yu Jin;Chung, Hae Gyung
    • Anxiety and mood
    • /
    • v.8 no.2
    • /
    • pp.113-119
    • /
    • 2012
  • Objective : The purpose of this study is to assess the utility of clinician administered posttraumatic stress disorder scale (CAPS) to diagnose combat related posttraumatic stress disorder (PTSD) in Korean veterans of the Vietnam War. Methods : Sixty-one Korean male veterans of the Vietnam war participated in this study. We compared the diagnostic values of CAPS, Korean version of mini international neuropsychiatric interview (MINI) against the Structured Clinical Interview for DSM-IV (SCID) in diagnosing PTSD. Results : The overall internal consistency of CAPS was 0.93. Compared to the SCID, total severity 45 (TSEV45) showed the best results among 5 CAPS scoring rules. In detail, sensitivity was 71.4%, specificity was 85.1, positive predictive value was 58.8%, negative predictive value was 90.9%, and accuracy was 82.0. Conclusion : CAPS was demonstrated as a reliable tool to diagnose combat related PTSD in the elderly. The optimum CAPS scoring was TSEV45.

A Study I on the Sizing Accuracy of the Characterized Defects of the Reactor Vessel Head Penetrations (원자로헤드 관통관 결함의 검출 정확성 연구)

  • Chung Tae-hoon;Kim Han-Jong
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.216-227
    • /
    • 2005
  • The head penetrations for control rod drive mechanism and instrumentation systems are installed at the reactor pressure vessel head of PWRs. Primary coolant water and the operating conditions of PWR plants can cause cracking of these nickel-based alloy through a process called primary water stress corrosion cracking (PWSCC). Inspection of the head penetrations to ensure the integrity of the head penetrations has been interested since reactor coolant leakages were found at U. S. reactors in 2000 and 2001. The complex geometry of the head penetrations and the very low echo amplitude from the fine, multiple flaws due to the nature of the see made it difficult to detect and size the flaws using conventional pulse-echo UT methods. Time-of-flight-diffraction technique, which utilizes the time difference between the flaw tips while pulse-echo does the flaw response amplitude from the flaw, has been selected for this inspection for it's best performance of the detection and sizing of the head penetration see flaws. This study defines the limits of the detectable and accurately sizable minimum flaw size which can be detected by the General TOFD and the Delta TOFD techniques for circumferentially and axially oriented flaws respectively. These results assures the reliability of the inspection techniques to detect and accurately size for various kind of flaws, and will also be utilized for the future development and qualifications of the TOFD techniques to enhance the detecting sensitivity and sizing accuracy of the flaws of the reactor head penetrations in nuclear power plants.

  • PDF

A Study of Crack Propagation and Fatigue Life Prediction on Welded Joints of Ship Structure (II) (선체 용접부의 균열진전 및 피로수명예측에 관한 연구(II))

  • Kim, Kyung-Su;Shim, Chun-Sik;Kwon, Young-Bin;Ko, Hee-Seung;Ki, Hyeok-Geun;Viswanathan, K.K.
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.45 no.6
    • /
    • pp.679-687
    • /
    • 2008
  • The fatigue life of ship structure under cyclic loading condition is made up of crack initiation and propagation stages. For a welding member in ship structure, the fatigue crack propagation life is more important than the fatigue crack initiation life. To calculate precisely the fatigue crack propagation life at the critical welding location, the knowledge of the residual stress sensitivity on the fatigue strength is necessary. In this study, thermo elastic-plastic analysis was conducted in order to examine the effect of residual stress on the fatigue crack propagation life. Also the fatigue crack propagation lives considering residual stress were calculated using fatigue crack growth code, AFGROW, on the basis of fracture mechanics. AFGROW is widely used for fatigue crack growth predictions under constant and variable amplitude loading. The reliability of AFGROW on the fatigue of ship structure was confirmed by the comparison of the estimated results with the fatigue propagation test results.

Effects of the Story Sharing Activity on Conflicting Situations by Using Children's Story on the Theory of Mind and Peer Competence of Preschoolers (동화를 활용한 갈등상황 이야기나누기 활동이 유아의 마음이론과 또래유능성에 미치는 영향)

  • Lee, Mi Hee;Lee, Soon Bok
    • Human Ecology Research
    • /
    • v.51 no.3
    • /
    • pp.293-306
    • /
    • 2013
  • The aim of this study is to examine the effects of the story sharing activity on-conflicting situations by the use of children's story on the theory of mind and peer competences of preschoolers so that appropriate teaching materials can be allocated for the actual preschool education site. The subjects of this study were 46 preschoolers under the age 4 at the attached kindergarten of P University in Pohang City, Gyeongbuk and in which 23 children among them were assigned to a test group and the other 23 to a control group. The collected data was analyzed by SPSS ver. 15.0 program and Cronbach's ${\alpha}$ coefficient was yielded to verify the reliability for each scale. The multivariate analysis of covariance (MANCOVA) was conducted. The analysis results are as follows. First, the story sharing activity on conflict situations by using children's story had a significant effect on the preschoolers' general appearance and actual task as sub-factors of the theory of mind, whereas no significant effects were found regarding the content change task and position change task. Second, the story sharing activity on conflict situations by using children's story had significant effect on the preschoolers' overall sensitivity, insecurity and pro-sociability as sub-factors of the peer competences, whereas no significant effects were found regarding the aggression, exclusivity and anti-sociability.

MRAS Based Sensorless Control of a Series-Connected Five-Phase Two-Motor Drive System

  • Khan, M. Rizwan;Iqbal, Atif
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.2
    • /
    • pp.224-234
    • /
    • 2008
  • Multi-phase machines can be used in variable speed drives. Their applications include electric ship propulsion, 'more-electric aircraft' and traction applications, electric vehicles, and hybrid electric vehicles. Multi-phase machines enable independent control of a few numbers of machines that are connected in series in a particular manner with their supply being fed from a single voltage source inverter(VSI). The idea was first implemented for a five-phase series-connected two-motor drive system, but is now applicable to any number of phases more than or equal to five-phase. The number of series-connected machines is a function of the phase number of VSI. Theoretical and simulation studies have already been reported for number of multi-phase multi-motor drive configurations of series-connection type. Variable speed induction motor drives without mechanical speed sensors at the motor shaft have the attractions of low cost and high reliability. To replace the sensor, information concerning the rotor speed is extracted from measured stator currents and voltages at motor terminals. Open-loop estimators or closed-loop observers are used for this purpose. They differ with respect to accuracy, robustness, and sensitivity against model parameter variations. This paper analyses operation of an MRAS estimator based sensorless control of a vector controlled series-connected two-motor five-phase drive system with current control in the stationary reference frame. Results, obtained with fixed-voltage, fixed-frequency supply, and hysteresis current control are presented for various operating conditions on the basis of simulation results. The purpose of this paper is to report the first ever simulation results on a sensorless control of a five-phase two-motor series-connected drive system. The operating principle is given followed by a description of the sensorless technique.

Coordinated Voltage Control Scheme for Multi-Terminal Low-Voltage DC Distribution System

  • Trinh, Phi Hai;Chung, Il-Yop;Kim, Taehoon;Kim, Juyong
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1459-1473
    • /
    • 2018
  • This paper focuses on voltage control schemes for multi-terminal low-voltage direct current (LVDC) distribution systems. In a multi-terminal LVDC distribution system, there can be multiple AC/DC converters that connect the LVDC distribution system to the AC grids. This configuration can provide enhanced reliability, grid-supporting functionality, and higher efficiency. The main applications of multi-terminal LVDC distribution systems include flexible power exchange between multiple power grids and integration of distributed energy resources (DERs) using DC voltages such as photovoltaics (PVs) and battery energy storage systems (BESSs). In multi-terminal LVDC distribution systems, voltage regulation is one of the most important issues for maintaining the electric power balance between demand and supply and providing high power quality to end customers. This paper focuses on a voltage control method for multi-terminal LVDC distribution system that can efficiently coordinate multiple control units, such as AC/DC converters, PVs and BESSs. In this paper, a control hierarchy is defined for undervoltage (UV) and overvoltage (OV) problems in LVDC distribution systems based on the control priority between the control units. This paper also proposes methods to determine accurate control commands for AC/DC converters and DERs. By using the proposed method, we can effectively maintain the line voltages in multi-terminal LVDC distribution systems in the normal range. The performance of the proposed voltage control method is evaluated by case studies.

Rank Decision of Ecological Environment Assessment Field Introducing Fuzzy Integral (퍼지적분을 도입한 생태환경평가부문의 순위결정)

  • You, Ju-Han;Jung, Sung-Gwan;Choi, Won-Young;Lee, Woo-Sung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.34 no.5 s.118
    • /
    • pp.39-51
    • /
    • 2006
  • This study was carried out to provide guidance to environmental policy makers when deciding which assessment fields (biotic, abiotic, qualitative, functional) should have priority for ecological preservation and to develop an objective and scientific methodology by introducing the engineering concept of the fuzzy integral. The grant of weights was used the eigenvalues calculated by factor analysis, and the converted values of indicators were obtained in multiplying the arithmetic values and eigenvalues. The results of the appropriateness and reliability of assessment fields were examined over 0.6, and the results showed that the design of questionnaire presented no great problems. When the fuzzy integral was calculated to determine the rankings at ${\lambda}$=1, 2, 3, 4, 5, respectively, they were 0.646, 0.630, 0.943, 1.423, and 1.167 for the biotic field, 1.298, 1.400, 0.901, 0.580, and 1.456 for the abiotic field, 0.714, 0.674, 0.346, 0.674, and 1.610 in the qualitative field and 1.000, 0.973, 0.943, 1.024, and 1.008 in the functional field. The sensitivity to ${\lambda}$ value showed that ${\lambda}=4$ was the most suitable. In comparison with ${\lambda}=0$ (the arithmetic mean), the range of change was narrow. Because the range for ${\lambda}=4$ was narrower than my other values, ${\lambda}=4$ was sure to be available in ranking-decision. The fuzzy integral is expected to be a method for analyzing and filtering human thoughts. In the future, in order to overcome linguistic uncertainty and subjectivity, other fuzzy integral models including Sugeno's method, AHP, and so forth should be used.

A Modified Quantum Dot-Based Dot Blot Assay for Rapid Detection of Fish Pathogen Vibrio anguillarum

  • Zhang, Yang;Xiao, Jingfan;Wang, Qiyao;Zhang, Yuanxing
    • Journal of Microbiology and Biotechnology
    • /
    • v.26 no.8
    • /
    • pp.1457-1463
    • /
    • 2016
  • Vibrio anguillarum, a devastating pathogen causing vibriosis among marine fish, is prevailing in worldwide fishery industries and accounts for grievous economic losses. Therefore, a rapid on-site detection and diagnostic technique for this pathogen is in urgent need. In this study, two mouse monoclonal antibodies (MAbs) against V. anguillarum, 6B3-C5 and 8G3-B5, were generated by using hybridoma technology and their isotypes were characterized. MAb 6B3-C5 was chosen as the detector antibody and conjugated with quantum dots. Based on MAb 6B3-C5 labeled with quantum dots, a modified dot blot assay was developed for the on-site determination of V. anguillarum. It was found that the method had no cross-reactivity with other than V. anguillarum bacteria. The detection limit (LOD) for V. anguillarum was 1 × 103 CFU/ml in cultured bacterial suspension samples, which was a 100-fold higher sensitivity than the reported colloidal gold immunochromatographic test strip. When V. anguillarum was mixed with turbot tissue homogenates, the LOD was 1 × 103 CFU/ml, suggesting that tissue homogenates did not influence the detection capabilities. Preenrichment with the tissue homogenates for 12 h could raise the LOD up to 1 × 102 CFU/ml, confirming the reliability of the method.