• Title/Summary/Keyword: reliability sensitivity

Search Result 730, Processing Time 0.027 seconds

A Study on the Dip-pen Nanolithography Process and Fabrication of Optical Waveguide for the Application of Biosensor

  • Kim, Jun-Hyong;Yang, Hoe-Young;Yu, Chong-Hee;Lee, Hyun-Yong
    • Transactions on Electrical and Electronic Materials
    • /
    • v.9 no.4
    • /
    • pp.163-168
    • /
    • 2008
  • Photonic crystal structures have been received considerable attention due to their high optical sensitivity. One of the techniques to construct their structure is the dip-pen lithography (DPN) process, which requires a nano-scale resolution and high reliability. In this paper, we propose a two dimensional photonic crystal array to improve the sensitivity of optical biosensor and DPN process to realize it. As a result of DPN patterning test, we have observed that the diffusion coefficient of the mercaptohexadecanoic acid (MHA) molecule ink in octanol is much larger than that in acetonitrile. In addition, we have designed and fabricated optical waveguides based on the mach-zehnder interferometer (MZI) for application to biosensors. The waveguides were optimized at a wavelength of 1550 nm and fabricated according to the design rule of 0.45 delta%, which is the difference of refractive index between the core and clad. The MZI optical waveguides were measured of the optical characteristics for the application of biosensor.

Catalytic combustion type hydrogen micro gas sensor using thin film heater and nano crystalline SnO2 (나노 결정 SnO2와 백금 박막히터를 이용한 접촉연소식 마이크로 가스센서의 감응특성 연구)

  • Han, Sang-Do;Hong, Dae-Ung;Han, Chi-Hwan;Chun, Il-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.3
    • /
    • pp.178-182
    • /
    • 2008
  • Planar type micro catalytic combustible gas sensor was developed by using nano crystalline $SnO_2$ Pt thin film as micro heater was deposited by thermal evaporation method on the alumina substrate. The thickness of the Pt heater was around 160 nm. The sensor showed high reliability with prominent selectivity against various gases(Co, $C_3H_8,\;CH_4$) at low operating temperature($156^{\circ}C$). The sensor with nano crystalline $SnO_2$ showed higher sensitivity than that without nano crystalline $SnO_2$. This can be explained by more active adsorption and oxidation of hydrogen by nano crystalline $SnO_2$ particles. The present planar-type catalytic combustible hydrogen sensor with nano crystalline $SnO_2$ is a good candidate for detection of hydrogen leaks.

Risk-informed approach to the safety improvement of the reactor protection system of the AGN-201K research reactor

  • Ahmed, Ibrahim;Zio, Enrico;Heo, Gyunyoung
    • Nuclear Engineering and Technology
    • /
    • v.52 no.4
    • /
    • pp.764-775
    • /
    • 2020
  • Periodic safety reviews (PSRs) are conducted on operating nuclear power plants (NPPs) and have been mandated also for research reactors in Korea, in response to the Fukushima accident. One safety review tool, the probabilistic safety assessment (PSA), aims to identify weaknesses in the design and operation of the research reactor, and to evaluate and compare possible safety improvements. However, the PSA for research reactors is difficult due to scarce data availability. An important element in the analysis of research reactors is the reactor protection system (RPS), with its functionality and importance. In this view, we consider that of the AGN-201K, a zero-power reactor without forced decay heat removal systems, to demonstrate a risk-informed safety improvement study. By incorporating risk- and safety-significance importance measures, and sensitivity and uncertainty analyses, the proposed method identifies critical components in the RPS reliability model, systematically proposes potential safety improvements and ranks them to assist in the decision-making process.

A Study to Validate the Korean Child Development Review (0-5세를 위한 한국형 영.유아 발달 선별검사(K-CDR)의 타당성에 대한 연구)

  • Shin, Hee-Sun;Kim, Jeong-Mee;Lim, Seong-Or
    • Child Health Nursing Research
    • /
    • v.13 no.2
    • /
    • pp.222-229
    • /
    • 2007
  • Purpose: This study was done to evaluate the validity of the Korean - Child Development Review in screening children with developmental risks. Method: The participants in the study were 172 children aged 6-75 months old and their parents. Data were collected by questionnaire or interview. Korean Denver II and Bayley test were administered with K-CDR for validation of children who were referred for developmental assessment at D University Hospital or public health center. The data were analyzed using correlation, $X^2$ test, and cross tab analysis. Results: There was a significant relationship between the K-CDR and Korean Denver II. The correlation coefficients were .42 to .61 by developmental sector. The sensitivity and specificity of K- CDR were .84 and .66 respectively when "abnormal" with MDI of Bayley test defined as lower than 85 the score which was used as a diagnosis of developmental delay. The responses to 6 questions for parents showed significant differences according to 3 groups by developmental state. Parents of children in the developmental disability group more frequently checked problems from the 26 problem checklist about their children's development and behavior. Conclusion: The results show that K-CDR is valid and has good sensitivity and moderate specificity in screening developmental delay.

  • PDF

A Study on the Probabilistic Safety Assessment and Sensitivity Analysis of Success Criteria of Large LOCA for APR+ (APR+ 확률론적 안전성평가 및 대형냉각재상실사고 성공기준과 파단크기 민감도 분석)

  • Moon, Horim;Kim, Han Gon
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.6
    • /
    • pp.129-134
    • /
    • 2016
  • Standard design of APR+(advanced power reactor plus) was certified at 2014 by Korea regulatory body. Based on the experience gained from OPR1000 and APR1400, the APR1400 was being developed as a 1,500MWe class reactor using Korean technologies for design code, reactor coolant pump, and man-machine interface system. APR+ has been basically designed to have the seismic design basis of safe shutdown earthquake (SSE) 0.3g, a 4-train safety concept based on N+2 design philosophy, and a passive auxiliary feedwater system (PAFS). Also, safety issues on the Fukushima-type accidents have been extensively reviewed and applied to enhance APR+ safety. APR+ provides higher reliability and safety against tsunami and earthquake. The purpose of this paper is to implement probabilistic safety assessment considering these design features and to analyze sensitivity of core damage frequency for large loss of coolant accident of APR+.

The effects of different FRP/concrete bond-slip laws on the 3D nonlinear FE modeling of retrofitted RC beams - A sensitivity analysis

  • Lezgy-Nazargah, M.;Dezhangah, M.;Sepehrinia, M.
    • Steel and Composite Structures
    • /
    • v.26 no.3
    • /
    • pp.347-360
    • /
    • 2018
  • The aim of this paper is to evaluate the accuracy and reliability of the available bond-slip laws which are being used for the numerical modeling of Fiber Reinforced Polymer (FRP)/concrete interfaces. For this purpose, a set of Reinforced Concrete (RC) beams retrofitted with external FRP were modeled using the 3D nonlinear Finite Element (FE) approach. All considered RC beams have been previously tested and the corresponding experimental data are available in the literature. The failure modes of these beams are concrete crushing, steel yielding and FRP debonding. Through comparison of the numerical and experimental results, the effectiveness of each FRP/concrete bond-slip model for the prediction of the structural behavior of externally retrofitted RC beams is assessed. The sensitivity of the numerical results against different modeling considerations of the concrete constitutive behavior and bond-slip laws has also been evaluated. The results show that the maximum allowable stress of FRP/concrete interface has an important role in the accurate prediction of the FRP debonding failure.

A Study on Dip-Pen Nanolithography Process to fabricate Two-dimensional Photonic Crystal for Planar-type Optical Biosensor (평판형 광-바이오센서용 2차원 광자결정 제작을 위한 Dip-Pen Nanolithography 공정 연구)

  • Kim Jun-Hyong;Lee Jong-Il;Lee Hyun-Yong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.3
    • /
    • pp.267-272
    • /
    • 2006
  • Optical waveguide based on symmetric and asymmetric Mach-Zehnder interferometer(MZI) type was designed, fabricated and measured the optical characteristics for the application of biosensor. The wavelength of the input optical signal for the device was 1550 nm. And the difference of refractive index was $0.45\;{\Delta}\%$ between core and cladding of the device. The TM(Transverse Magnetic) mode optical properties of the biosensor were analyzed with the refractive index variation of gold thin film deposited for overclad. Nowadays, nano-photonic crystal structures have been paied much attention for its high optical sensitivity. There is a technique to realize the structure, which is called Dip-Pen Nanolithography(DPN) process. The process requires a nano-scale process patterning resolution and high reliability. In this paper, two dimensional nano-photonic crystal array on the surface was proposed for improving the sensitivity of optical biosensor. And the Dip-Pen Nanolithogrphy process was investigated to realize it.

Proposed Approach of Korean Ecological Risk Assessment for the Derivation of Soil Quality Criteria (토양준거치 도출을 위한 국내형 생태위해성평가기법 제안)

  • An, Youn-Joo;Lee, Woo-Mi;Nam, Sun-Hwa;Jeong, Seung-Woo
    • Journal of Soil and Groundwater Environment
    • /
    • v.15 no.3
    • /
    • pp.7-14
    • /
    • 2010
  • Ecological Risk Assessment (ERA) supports a decision-making process such as establishment of environmental quality criteria. Soil quality criteria (SQC) are essential to protect soil organisms from the exposure to various soil contaminants. In this study, ERA methodologies of advanced countries for soil pollution were extensively compared to propose the ERA approach suitable for soil ecosystem in Korea. The soil ERAs in European Chemical Bureau(ECB), The Netherlands, and Canada can be classified as deterministic ecological risk assessment (DERA), and probabilistic ecological risk assessment (PERA) based on species sensitivity distribution (SSD). We propose three ERA methods according to abundance and reliability of soil ecotoxicity data. The method considered land use such as residential/agricultural, and industrial/commercial uses. The taxonomic groups of soil organism were classified as 'Class' level including different trophic levels (Magnoliopsida or Liliopsida, Clitellata, and Insecta or Secernentea). This study can be used to estimate the soil quality criteria to protect soil biota.

Development of FBG Micro Cone Penetrometer for Layered Soil Detection (다층지반 탐지를 위한 광섬유 마이크로콘의 개발)

  • Kim, Rae-Hyun;Lee, Woo-Jin;Yoon, Hyung-Koo;Lee, Jong-Sub
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.341-348
    • /
    • 2009
  • Various types of micro cone penetrometers have been developed by using strain gages for the layered soil detection. Strain gages, however, are affected by several factors such as temperature, self heating and lead wire length. In this study, micro cone penetrometers with 3~7mm in diameter, are developed by using FBG sensor to overcome the defects of the strain gage, and compensate the effect of temperature during penetration. In order to verifiy the accuracy and reliability of the developed FBG cone, the cone penetration test is performed on the layered soil. The tip resistance of FBG snesor shows excellent sensitivity, and can detect the interface of the layered soils with higher resolution. In addition, the 3mm micro cone penetrometer which is impossible cone diameter by using strain gages presents much higher sensitivity than the 7mm cone penetrometer. This study suggests that FBG sensor is a useful sensor for manufaturing the ultra small sized cone, and effectively detects the interface of the layered soil.

  • PDF

Diagnostic Value on the Orthopaedic Tests for Sacroiliac Joint Dysfunction (천장관절 기능부전에 대한 검사방법들의 진단적 가치 : 정형도수치료적 평가를 중심으로)

  • Yoon, Hong-Il;Sim, Hyun-Po
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.16 no.1
    • /
    • pp.64-76
    • /
    • 2010
  • The sacroiliac joint is difficult to appropriately examine and treat because it is extremely complex and also is difficult to distinguish dysfunctions from those of the spine and hip which are highly intergrated functionally. In addition generally traditional x-rays and CT scans also are not beneficial in detecting sacroiliac joint dysfunction. The manipulative physiotherapist should seek to establish a series of relevant finding that build into a case implicating the sacroiliac joint. When deciding to use these diagnostic tests, the examiner must determine if the test will give reliable and useful information that will help in the diagnosis and subsequent treatment. To be useful diagnostic tests must give reliable data and be valid and the most useful methods of determining whether a test is a good test for pathology under consideration are sensitivity and specificity. In the ideal world, one would want a test that has both high sensitivity and high specificity. The purpose of this review is to ascertain diagnostic value on the tests for sacroiliac joint dysfunction by literature.

  • PDF