• Title/Summary/Keyword: reliability assessment test

Search Result 694, Processing Time 0.027 seconds

Reliability Test Assessment Technique for Pressure Compensation Type Hydraulic Pump (압력보상형 유압펌프 신뢰성 시험평가 기술)

  • Jung, Dong-Soo
    • Journal of Applied Reliability
    • /
    • v.11 no.4
    • /
    • pp.371-385
    • /
    • 2011
  • Because consumer mostly utilizes company test standard, supplier spends burden of expenses on building test equipments and managing expert manpower to fulfill consumer's various tests. Therefore, it is urgent to standardize test assessment which has a bond of sympathy between consumer and supplier and evaluates reliability of their products. This study develops reliability assessment standard which is composed of 12 test items considering international and domestic test standards, company internal test standards of consumer companies and field conditions. Also this study introduces overall technical procedure on accelerated test with no failure which is used for the main technology of reliability assessment. To verify effectiveness of reliability assessment, the test results are herein analyzed through building the test equipments and performing the test items.

Reliability Assessment Criteria of Power Light Emitting Diodes for Lighting fittings (조명용 Power LED의 신뢰성평가기준)

  • Park, Chang-Kyu;Jeong, Hee-Suk;Jeong, Hai-Sung;Baik, Jai-Wook
    • Journal of Applied Reliability
    • /
    • v.9 no.3
    • /
    • pp.219-231
    • /
    • 2009
  • Power light emitting diodes(LED) for lighting fittings are so much environment-friendly, highly reliable and consume less energy that they are widely used at home and in industries such as electronics, telecommunications and industrial machineries. However, they are exposed to a very diverse environment and consists of complex components and, therefore needs careful approach to the enhancement and assessment of reliability of the item. In this article reliability assessment criteria for LED are established in terms of performance assessment test, reliability assessment test and accelerated test.

  • PDF

Construction of Reliability Assessment Infrastructure for Spacers in GIS (GIS용 절연스페이서 신뢰성령가기반 구축)

  • Lee, J.G.;Kim, M.K.;Kim, I.S;Jeong, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2006.10a
    • /
    • pp.180-181
    • /
    • 2006
  • In this paper, there have been brief review about the important consideration in laboratory planning and construction of the reliability assessment infrastructure including 400 kV, 120 kVA AC test system, which enable to evaluate the HV long-term overcharged withstand performance for spacers using in Gas Insulated Switchgears up to transmission class, Also it is described simply about its trial running of the whole test system and its assessment example. To inform the founded national code, RS C 0084, and the procedure for getting a reliability assessment certificate issued by the government, brief description of the code and summation of test results have been conducted.

  • PDF

Understanding the Degradative Effects of Different Climatological Conditions on Architectural Coatings: Progress Report on Korea Institute of Construction Materials Site Comparison Study of Seosan (Korea) Outdoor Exposure Testing Facility

  • Choi, Yoon;Pyo, Soonjin;Seo, Junsik;Yang, Inmo;Kim, Seungjin;Kim, Sangmyoung
    • Corrosion Science and Technology
    • /
    • v.8 no.3
    • /
    • pp.116-118
    • /
    • 2009
  • Korea Institute of Construction Materials founded Seosan Outdoor Exposure Test Site 2005 at Korea, which is a part of Worldwide Exposure Network (WEN). To evaluate the test site along with other exposure test sites, three different types of paints have been under real time weathering conditions at three major weathering test facilities around the world. Using these test specimens several spectroscopic experiments along with physical tests have been performed. Also acceleration tests have been performed using the same paints. The correlation of weathered paints among three different test facilities and accelerated test results has been compared. From the results the reliability of Seosan Weathering Test Facility and reasonable life time prediction tests are discussed.

Study on Properties and Accelerated Life-time Test of Rubber O-ring by Temperature Stress

  • Shin, Young-Ju;Kang, Bong-Sung;Chung, Yu-Kyung;Choi, Kil-Yeong;Shin, Sei-Moon
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2006.05a
    • /
    • pp.48-54
    • /
    • 2006
  • In this thesis, accelerated life test (ALT) method and procedure for rubber O-ring are applied to assure specified reliability of the products at guaranteeing the life of the products. Rubber O-ring is parts that keep intensity or make machine operation smoothly on attrition portion of machine and is used to prevent that oil is leaked. Usually. Rubber O-ring used NBR that is copolymer of acrylonitrile and butadiene. this are superior oil resistance, heat resistance, durability of abrasion, cold resistance, chemical resistance etc. The accelerated life test model for rubber O-ring are developed using the relationship between stresses and life characteristics of products. Using the accelerated life test method and the acceleration life test equipment which is developed, we performed life test, collected life data and analyzed the results of tests. The proposed accelerated life test method and procedure may be extended and applied to testing similar kinds of products to reduce test times and costs of the tests remarkably.

  • PDF

Study for the Reliability Evaluation of a Volute Pump (벌류트 펌프의 신뢰성 평가에 관한 연구)

  • Jung, Dong Soo;Lee, Yong Bum;Kang, Bo Sik
    • Journal of Drive and Control
    • /
    • v.15 no.4
    • /
    • pp.23-29
    • /
    • 2018
  • The objective of this paper is to evaluate the reliability of a volute pump and presents test results through performance and life tests. The performance and life test methods were presented by analyzing the failure modes of the volute pump. Zero failure test time was calculated to evaluate the reliability of the volute pump and then, the test was performed under accelerated conditions. The test was also carried out to check the failure modes of the field conditions. This study can be provided to improve the product reliability through failure analysis of the volute pump. And failure cause of typical failure case has been investigated and improvement design has been presented. The performance test results of before and after the accelerated life test were presented to confirm the improved reliability of the volute pump.

Reliability Assessment Criteria of Motorized Roller Conveyor (자체구동롤러 컨베이어의 신뢰성 평가기준)

  • Kim, Young-Joo;Go, Hee-Yang;Han, In-Sup;Kim, Yong Soo
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.24 no.5
    • /
    • pp.521-529
    • /
    • 2015
  • Owing to a reliance on imported products from Europe and Japan, the use of logistics equipment with poor energy efficiency coupled with high maintenance costs can lead to high operating costs for some domestic logistic centers. To lower their operating costs, the logistic centers use motorized roller conveyors. In order to commercialize this process, it is necessary to establish the test criteria and assess the reliability of the process. Currently, there exists no standard verification method to test the reliability of motorized roller conveyors. In this study, we propose reliability assessment criteria for a: i) reliability test, ii) environmental test, iii) safety test, and iv) lifetime test.

Reliability Assessment Criteria of Wiper Motor for Automobiles (자동차용 와이퍼 모터의 신뢰성평가기준)

  • Choi, Man-Yeop;Shin, Wae-Gyeong;Jeong, Hai-Sung;Baik, Jai-Wook
    • Journal of Applied Reliability
    • /
    • v.9 no.3
    • /
    • pp.195-218
    • /
    • 2009
  • Wiper motors are used in every automobile. They are exposed to a very diverse environment and consists of several components and, therefore needs careful approach to the enhancement and assessment of reliability of the item. In this article reliability standards for wiper motors are established in terms of quality certification test and failure rate test.

  • PDF

Reliability Assessment Criteria of Reflector for Lamp of BLU(Back Light Units) (BLU(Back Light Units) 램프 반사갓의 신뢰성평가기준)

  • Park, Chang-Kyu;Jeong, Hee-Suk;Jeong, Hai-Sung
    • Journal of Applied Reliability
    • /
    • v.11 no.1
    • /
    • pp.17-30
    • /
    • 2011
  • Many domestic manufacturers make reflectors for Lamps of BLU(back light units). However, color change and parting occur as a result of diverse usage environment. Therefore, many of the manufacturers are reluctant in R&D investment of reflectors for Lamps of BLU. Hence, in this article reliability assessment criteria for reflector for lamp of BLU are established in terms of performance test, environment test and life test.

Reliability assessment test for heavy sluice gate of hydraulic cylinder (수문용 대형 유압실린더의 신뢰성 평가)

  • 이용범;현동수;김형의;이근호;정동수
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2001.06a
    • /
    • pp.91-97
    • /
    • 2001
  • These Study are for the development of the reliability assessment test code and test equipment and test procedures of the heavy sluice gate hydraulic cylinder. Because there is no reliability test code for the heavy sluice gate hydraulic cylinder inside and outside of the country, the modified reliability test code is made reference for the related existing standards like as ISO, JIS, MIL, TUV, DIN, KS and etc. In this study, the novel method is proposed to evaluate efficiency of the heavy sluice gate hydraulic cylinder on the loading conditions and established the conditions of the acceleration life test to reduce the testing time and cycles. The testing equipments for life test, lode operating test, high and low temperature test and salt spray test have been established for 8 month, and the reliability tests are accomplished. The test results of the heavy sluice gate hydraulic cylinder which is produced and tested initially in Korea are satisfied the durability life cycle on the using conditions.

  • PDF