• Title/Summary/Keyword: release height

Search Result 168, Processing Time 0.027 seconds

A Study on the Evacuation Performance Review for the Office Buildings (업무용 빌딩의 피난 성능 검토에 관한 연구)

  • 오혁진;백승태;김우석;이수경
    • Fire Science and Engineering
    • /
    • v.17 no.3
    • /
    • pp.1-6
    • /
    • 2003
  • In this study, it reviewed about evacuation performance of a specified Office Building. assessment tools is FAST 3.1.7 (Estimation of Flash Over, Estimation of Layer Height Down Flow Time), SIMULEX 32-bit (Estimation of Evacuation Time), JASMINE 3.25d. (Smoke Flow Assessment of a specified time) Result from Fire Scenario # 1, Flash Over is not generated in Compartment. Evacuation Time is estimated 25.2 sec by SIMULEX 32-bit. layer height until this time (25.2 sec) was estimated 2.4 m by FAST 3.1.7. After ignition until this time (25.2 sec), smoke was not release to the a corridor. In consequence, We concluded that people in building are completing the safe evacuation without the damage of smoke. Result from Fire Scenario # 1, Flash Over generated 6 min 33.2 sec in Compartment. Evacuation Time is estimated 1 min 25.5 sec by SIMULEX 32-bit. layer height down flow time is 1 min 40.8 sec by FAST 3.1.7 and 5 min 23 sec by theoretical calculation. Also, total building evacuation time was estimated 2 min 26.6 sec. After ignition until this time (2 min 26.6 sec), smoke released to the a corridor but it amount was few little. Therefore, generated smoke in compartment not effected to the people in buildings.

Installed Spacing and Reponse Time Index of Heat Detection Devices (열감지장치의 응답시간지수와 경계구역)

  • 권오승;이복영;김동석
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.72-75
    • /
    • 1996
  • The objectives of this paper investigate the effect of installed spacing on the activation of spot type heat detection devices. The flow of hot gases under a ceiling resulting from the impingement of a fire plume activates heat detectors and sprinklers. Local temperature and velocity in this ceiling jet are usually expressed with the function of a ceiling height, the distance from a fire location and the heat release rate of fire. And detectors having different. RTI respond in different ways to the same temperature and velocity of ceiling jet. Thus great care should be taken to decide installed spacing of heat detection devices by considering above effects.

  • PDF

Experimental Study on Laminar Lifted Methane Jet Flame Diluted with Nitrogen and Helium

  • Sapkal, Narayan;Lee, Won June;Park, Jeong;Kwon, Oh Boomg
    • 한국연소학회:학술대회논문집
    • /
    • 2014.11a
    • /
    • pp.387-389
    • /
    • 2014
  • Laminar lifted methane jet flame diluted with nitrogen and helium in co-flow air has been investigated experimentally. This paper examines the role of chemistry, intermediate species responsible for stabilization of lifted flame. To elucidate the stabilization mechanism in lifted methane jet flames with Sc<1, the chemiluminescence intensities of $CH^*$ and $OH^*$ were measured using ICCD camera at various nozzle exit velocities and fuel mole fractions. It has been observed that the $OH^*$ species can play an important role in stabilization of lifted methane jet flame as they are good indicators of heat release rate which can affect on flame speed and increase stability through reduction in ignition delay time.

  • PDF

Experimental Study on Laminar Lifted Methane Jet Flame Diluted with Nitrogen and Helium

  • Sapkal, Narayan;Lee, Won June;Park, Jeong;Kwon, Oh Boomg
    • 한국연소학회:학술대회논문집
    • /
    • 2014.11a
    • /
    • pp.125-128
    • /
    • 2014
  • Laminar lifted methane jet flame diluted with nitrogen and helium in co-flow air has been investigated experimentally. This paper examines the role of chemistry, intermediate species responsible for stabilization of lifted flame. To elucidate the stabilization mechanism in lifted methane jet flames with Sc<1, the chemiluminescence intensities of $CH^*$ and $OH^*$ were measured using ICCD camera at various nozzle exit velocities and fuel mole fractions. It has been observed that the $OH^*$ species can play an important role in stabilization of lifted methane jet flame as they are good indicators of heat release rate which can affect on flame speed and increase stability through reduction in ignition delay time.

  • PDF

Non-linear study of mode II delamination fracture in functionally graded beams

  • Rizov, Victor I.
    • Steel and Composite Structures
    • /
    • v.23 no.3
    • /
    • pp.263-271
    • /
    • 2017
  • A theoretical study was carried-out of mode II delamination fracture behavior of the End Loaded Split (ELS) functionally graded beam configuration with considering the material non-linearity. The mechanical response of ELS was modeled analytically by using a power-law stress-strain relation. It was assumed that the material is functionally graded transversally to the beam. The non-linear fracture was investigated by using the J-integral approach. Equations were derived for the crack arm curvature and zero axes coordinate that are needed for the J-integral solution. The analysis developed is valid for a delamination crack located arbitrary along the beam height. The J-integral solution was verified by analyzing the strain energy release rate with considering material non-linearity. The effects of material gradient, non-linear material behavior and crack location on the fracture were evaluated. The solution derived is suitable for parametric analyses of non-linear fracture. The results obtained can be used for optimization of functionally graded beams with respect to their mode II fracture performance. Also, such simplified analytical models contribute for the understanding of delamination fracture in functionally graded beams exhibiting material non-linearity.

An Investigation of the Effect of Schotky Barrier-Height Enhancement Layer on MSMPD Dynamic Characteristics

  • Seo, Jong-Wook
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.2 no.2
    • /
    • pp.141-146
    • /
    • 2002
  • The effect of the wide-bandgap Schottky barrier enhancement cap layer on the performance of metal-semiconductor-metal photodetectors (MSMPD's) is presented. Judged by the dc characteristics, no considerable increase in recombination loss of carriers is resulted by the incorporation of the cap layer. However, about 45% of the detection efficiency is lost for the cap-layered MSMPD's even with a graded layer incorporated under pulse operation, and it was found to be due mainly to the capturing and slow release of the photocarriers at the heterointerface. The loss mechanism of the pulse detection efficiency is believed to be responsible for the intersymbol interference and the increased bit-error-rate (BER) observed in MSMPD's when used with a high bit rate pseudo-random-bit-stream (PRBS) data pattern.

The Water Curtain Installation Guideline for Fire Spread Prevention in Market (재래시장의 화재확산 방지를 위한 수막설비 설치 지침)

  • Choi, Jung-Uk;Cho, Sung-Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.7
    • /
    • pp.269-274
    • /
    • 2016
  • This paper aims to suggest the water curtain installation guideline for prevention of fire spread. The water curtain systems play a role in preventing fire spread which is caused by fire flames and radiation heat release from a fire source. The radiation attenuation ratio is affected by the water droplet size, vertical distance from the nozzle and flow rate. This study suggests the water curtain installation guideline as follows : (1) Investigation of a reference store array (2) Calculation of the number of drencher heads (3) Review of the relationship between droplet size and attenuation factor depending on the height of the drencher head (4) Review of a drencher head array and spray overlapping. The reference traditional market in which a fire compartment is installed using a water curtain can be predicted to have a radiation attenuation ratio of 50%.

Disposable Microfluidic Infusion Pump using Elastomeric Blister Actuator (탄성 블리스터 액츄에이터를 이용한 일회용 미세유체 주입펌프)

  • Jang, Woong Ki;Kim, Hyung Jin;Kim, Byeong Hee;Seo, Young Ho
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.2
    • /
    • pp.235-240
    • /
    • 2013
  • This paper presents a disposable microfluidic infusion pump using the restoring force of elastomeric membrane of Polydimethylsiloxane. Microfluidic infusion pump consists of hydraulic resistance control part, elastomeric blister actuator part, drug inlet and outlet. Expanded elastomeric blister actuator continuously pushes liquid in the chamber to outlet. At same time, microchannel diameter near the outlet was controlled by thin elastomeric membrane in hydraulic resistance control part. Eventually flow rate of infused liquid is controlled by air pressure. In experimental study, the amount of the filled liquid in the blister is precisely controlled by the height of the blister. Flow rate of infused liquid could be controlled, that is, controlled release of the drug over time was possible by adjusting hydraulic resistance and restoring pressure with the blister actuator.

Effects of a wall on the self-ignition of sudden release of high-pressure hydrogen through a tube (벽면에 의한 고압 수소 누출에 따른 자발화 현상 특성 변화)

  • Kim, Seihwan;Park, Ji Hyun;Lee, SeungBok;Lee, Hyung Jin;Jeung, In-Seuck
    • 한국연소학회:학술대회논문집
    • /
    • 2012.04a
    • /
    • pp.245-246
    • /
    • 2012
  • The possibility that self-ignition can be generated near an obstacle is high in practical applications such as a hydrogen car. In this paper, experimental investigations were suggested to understand the effects of a wall on self-ignition phenomena through high-speed images. The results showed that the existence of a wall could not change the ignition phenomena itself irrespective of wall height and burst pressure. However, when a strong flame was induced in the tube, a wall could promote the flame stabilization.

  • PDF

Sticking and Desorption of Atomic Hydrogen on the Armchair Edges of Bilayer Graphene

  • Natividad, Michelle;Arboleda Jr., Nelson;Kasai, Hideaki
    • Journal of Electrochemical Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.185-189
    • /
    • 2016
  • The coupled channel method via the Local Reflection (LORE) matrix is employed to investigate the quantum mechanical behavior of the sticking or adsorption and desorption of hydrogen (H) atom on bilayer graphene via the armchair edge. The sticking and desorption probabilities of H are calculated and are plotted against the initial translational energy of H. The sticking probability plot shows a barrierless reaction indicating that hydrogen is easily adsorbed on the armchair edge of graphene. The desorption probability plot, however, shows that desorption of H from the graphene sheets is an activated process with a barrier height of 4.19 eV suggesting that a strong bond exists between the adsorbed H atom and the edge carbon atom. Thus, temperatures higher than the operating temperatures (300 - 1500 K) of conventional fuel cells are necessary to release the adsorbed H atom from the armchair edge of graphene.