• 제목/요약/키워드: release characteristics

검색결과 1,331건 처리시간 0.033초

콘칼로리미터를 이용한 섬유강화플라스틱(FRP)의 연소특성 (Combustion Characteristics of Fiber Reinforced Plastic by Cone Calorimeter)

  • 이근원;김관응;이두형
    • 한국화재소방학회논문지
    • /
    • 제18권2호
    • /
    • pp.67-72
    • /
    • 2004
  • 본 연구는 작업장의 건축물이나 구조물의 구성요소로 사용되어지는 섬유강화플라스틱의 연소특성을 평가하였다. 섬유강화플라스틱의 연소특성은 ISO 5660에 따라 콘칼로리미터를 사용하여 수행하였다. 섬유 강화플라스틱의 착화시간과 열방출율은 복사열과 난연제의 함량에 따라 달랐다. 섬유강화플라스틱의 열방출율은 복사열의 증가에 따라 증가하였다. 섬유강화플라스틱의 착화시간과 최대 열방출율을 이용하여 플래쉬오버(Flashover)의 가능성을 Petrella가 제시한 분류방법에 따라 검토하였다.

탄소재료의 적용 방법에 따른 파티클 보드의 연소 특성 (Evaluation of Fire Characteristics for Particle-board with Exfoliated Graphite Nanoplatelets Added)

  • 서현정;조정민;황욱;이민철
    • 한국연소학회지
    • /
    • 제22권4호
    • /
    • pp.1-8
    • /
    • 2017
  • This study was conducted to evaluate the fire retardant performance of exfoliated graphite nanoplatelets (xGnP) applied for particleboard. This work measured heat release rate(HRR), total heat release(THR) and smoke production rate(SPR) of xGnP added particleboard, using cone calorimeter to assess its fire characteristics according to the KS F ISO 5660-1 standard code. Heat release rates of all specimens treated by xGnP were less than the $200kW/m^2$ for a total experiment period of five minutes. Heat release rates of the specimens coated with xGnP were lower than those of the specimens made by mixing wood particles with xGnP directly. Meanwhile, the total heat release rates of xGnP coated specimen maintained quite lower level than the uncoated so the xGnP coating were effective in improving the fire retardant performance of particleboard. However, the smoke emission peaking problem at the initial combustion period, which was caused by adding base coating materials, should be resolved for further satisfaction as a fire retardant materials.

유동 섭동에 의한 난류예혼합화염의 열발생 모델에 관한 연구 (A Heat Release Model of Turbulent Premixed Flame Response to Acoustic Perturbations)

  • 조주형;백승욱
    • 대한기계학회논문집B
    • /
    • 제32권6호
    • /
    • pp.413-420
    • /
    • 2008
  • The unsteady heat release characteristics play a significant role in combustion instabilities observed in low emissions gas turbine combustors. Such combustion instabilities are often caused by coupling mechanisms between unsteady heat release rates and acoustic perturbations. A generalized model of the turbulent flame response to acoustic perturbations is analytically formulated by considering a distributed heat release along a curved mean flame front and using the flame's kinematic model that incorporates the turbulent flame development. The effects of the development of flame speed on the flame transfer functions are examined by calculating the transfer functions with a constant or developing flame speed. The flame transfer function due to velocity fluctuation shows that, when a developing flame speed is used, the transfer function magnitude decreases faster with Strouhal number than the results with a constant flame speed at low Strouhal numbers. The flame transfer function due to mixture ratio fluctuation, however, exhibits the opposite results: the transfer function magnitude with a developing flame speed increases faster than that with a constant flame speed at low Strouhal numbers. Oscillatory behaviors of both transfer function magnitudes are shown to be damped when a developing flame speed is used. Both transfer functions also show similar behaviors in the phase characteristics: The phases of both transfer functions with a developing flame speed increase more rapidly than those with a constant flame speed.

Prenatal effect of pyrantel pamoate on several hematological parameter of offspring in mice

  • Abdulwahab.A.Noorwall;Ghazi M. Al-Hachim;Award -Omar
    • Archives of Pharmacal Research
    • /
    • 제9권2호
    • /
    • pp.87-91
    • /
    • 1986
  • In attempt to develop a drug delivery system using serum albumin microspheres, bovine serum albumin microspheres containing antitumar agent. Cytarabine, were prepared. The shape, surface characteristics, size distribution, behavior of in vivo distribution, drug release behavior, and degradation of albumin microsphers in animal liver issue homogenate and proteolytic enzyme were investigated. The shape of albumin microspheres was spherical and the surface was smooth and compact. The size distribution of the albumin microspheres was effected by dispertion forces during emulsification and albumin concentration. Distribution of albumin microspheres after imtravenous administration in rabbit was achieved immediately. In vitro, albumin microsphere matrix was so hard that it retained most of cytarabine except initial burst during the first 10 minutes, and the level of drug release during the initial burst was affected by heating temperature, drug/albumin microsphere matrix was so hard that it retained most of cytarabine except initial burst during the first 10 minutes, and the level of drug release during the initial burst was affected by heating temperature, drug/albumin concentration ratio and size distribution. After drug release test, the morphology of albumin microspheres was not changed. Albumin microsphere matrix was degraded by the animal liver issue homogenate and proteolytic enzyme. The degree of degradation was affected by heating temperature.

  • PDF

대형서점 적재가연물의 초기 연소발열성상 (Heat Release Characteristics of Typical Live Fire Load in Large Bookstore)

  • 남동군
    • 한국화재소방학회논문지
    • /
    • 제25권2호
    • /
    • pp.88-94
    • /
    • 2011
  • 건축물 적재가연물의 연소성상 및 발열특성은 건물 내부의 화재전파속도와 화재규모 등을 크게 좌우하는 중요한 요인이다. 그러나 대형 서점의 적재가연물은 다른 건축용도에 비해 다량 적재되어 있기 때문에 화재시 건물 전체의 화재피해가 대형화할 가능성이 있지만 연소발열성상이 화재실험 등으로 파악되어 있지 않다. 따라서 본 연구는 대형서점의 적재가연물인 목재 서가 등을 재현한 시험체를 대상으로 연소실험을 실행하여 연소발열성상을 파악하였다. 또한 이 결과를 바탕으로 대형서점의 화재시 화재안전성을 검토하고 대형 서점의 화재안전설계에 필요한 적재가연물의 연소표면적당 최대열방출률과 화재성장률 등을 제시하였다.

Serious Complications of the Percutaneous A1 Pulley Release: Case Reports and Literature Review

  • Dong Chul Lee;Kyung Jin Lee;Hohyung Lee;Sung Hoon Koh;Jin Soo Kim;Si Young Roh
    • Archives of Plastic Surgery
    • /
    • 제51권1호
    • /
    • pp.110-117
    • /
    • 2024
  • Percutaneous first annular pulley (A1 pulley) release, which has been increasingly used to treat trigger fingers, has been widely established as a safe and simple procedure. Multiple studies have reported positive results of percutaneous A1 pulley release. In this study, however, we report cases of patients who developed complications after undergoing percutaneous A1 pulley release at local clinics. A total of six patients visited our hospital for infectious complications after percutaneous A1 pulley release. Various sequelae such as damage to normal structures, insufficient procedure, and tissue necrosis were observed during the exploration. A retrospective study was conducted to identify the cause and trend of the observed complications by instruments (HAKI knife or needle). In the HAKI knife group, there was a tendency for damage to normal structures, while in the needle group, an insufficient release or serious soft tissue necrosis was observed. Based on these cases, our findings confirm the existence and characteristics of infectious complications following the percutaneous A1 pulley release. We further identify that the type of instrument used predicts the nature of complications. Thus, reliable and skilled performance of the procedure by experts is essential for safe treatment.

Study on the Combustion Characteristics of Tulip Tree (Liriodendron tulipifera) for Use as Interior Building Materials

  • Min Ji KIM;Sang-Joon LEE;Sejong KIM;Myung Sun YANG;Dong Won SON;Chul-Ki KIM
    • Journal of the Korean Wood Science and Technology
    • /
    • 제51권5호
    • /
    • pp.410-418
    • /
    • 2023
  • In this study, the combustion characteristics of the Tulip tree, which is the representative broad-leaved afforestation tree in Korea, were analyzed. The flame retardant performance of the Tulip tree was analyzed by analyzing combustion characteristics on a total of three test samples; flame retardant treated, both flame retardant and oil stain-treated, and untreated. Then the flame retardance grade was classified for each of them. According to the result, test samples showed the strongest flame retardance were in order of flame retardant treated (C), both flame retardant and oil stain-treated (B), and untreated (A). As a result of analyzing the total heat emission and maximum heat emission rates, which is the evaluation standard for interior materials of Korean domestic buildings, test samples with flame retardant treat or flame retardant and oil stain treat were qualified for the flame-retardant standard. Both flame retardant and oil stain-treated samples showed higher total heat release (THR) and heat release rate compared to flame retardant-treated samples as the oil causes combustion with oxygen. On the other hand, they didn't qualify the THR in Quasi-non-combustible standards. To determine the correlation between the physical and combustion characteristics of wood, the combustion characteristics of other diffuse porous wood species, with which the Tulip tree is affiliated were analyzed, and noticed that the characteristic correlates with the density and quantity of wood. The results of this study are expected to be used as basic information on the combustion characteristics of the Tulip tree.

다중에멀젼법을 통한 슈도모나스를 함유하는 PCL 마이크로캡슐의 제조 및 특성 연구 (Preparation and Characteristics of Poly(ε-caprolactone) Microcapsules Containing Pseudomonas by W/O/W Emulsion)

  • 김기석;이승엽;이건웅;김형곤;박수진
    • 폴리머
    • /
    • 제36권2호
    • /
    • pp.202-207
    • /
    • 2012
  • 슈도모나스를 함유하는 poly(${\varepsilon}$-caprolactone)(PCL) 마이크로캡슐은 다중에멀젼 시스템에 의하여 제조하였고, 제조조건에 따른 마이크로캡슐의 특성과 방출거동에 대하여 조사하였다. 마이크로캡슐의 형태와 입도분포는 주사전자현미경과 입도분석기를 이용하여 관찰하였고, 방출거동은 액체배양법을 통하여 확인하였다. 다양한 제조조건에 따라 제조된 마이크로캡슐은 10~60 ${\mu}m$의 입자크기와 표면이 매끈하고 균일한 구형의 마이크로캡슐이 형성됨을 확인하였다. 열분석 결과, 마이크로캡슐은 약 $58^{\circ}C$에서 용융피크를 나타내었고 벽재물질의 함량 증가에 따라 용융열이 증가함으로써 벽재의 두께는 PCL 함량에 비례함을 확인할 수 있었다. 또한 슈도모나스의 방출속도는 유화제 함량, 교반속도, PCL 함량에 따라 조절이 가능하며 이는 유화제 함량과 교반속도 증가에 따른 입자 크기의 감소에 의한 비표면적 증가와 벽재물질의 두께 증가에 인한 방출속도의 감소에 의한 것으로 판단된다.

폴리에틸렌옥사이드를 이용한 세파트리진프로필렌글리콜 서방성매트릭스 정제의 제조 및 평가 (Pharmaceutical Formulation and Evaluation of Sustained - Release Hydrophilic Matrix Tablet of Cefatrizine Propyleneglycol Using Polyethylene Oxide)

  • 이언형;박선영;지웅길;김동출
    • Journal of Pharmaceutical Investigation
    • /
    • 제31권1호
    • /
    • pp.37-41
    • /
    • 2001
  • Various characteristics of polyethylene oxide (PEO) are useful for drug delivery systems. In this study, PEO was used as a sustained release matrix system containing cefatrizine propyleneglycol (Cefa-PG) which is a new semi-synthetic broad-spectrum and orally active cephalosporin. Five kinds of sustained release matrix tablets were formulated with various content of PEO and other ingredients. And three types of matrix tablets were formulated of which compositions were the same but the hardness was different. It was found that PEO content influenced drug release rate. Increasing PEO content, the drug release rate from matrix tablets was decreased. In addition, Avicel, one of the ingredients of matrix components, changed the drug release from the sustained release PEO matrix tablets. With increasing Avicel content, the rate of drug release was increased. For the effect of hardness of matrix tablets, the rate of drug release is decreased with increasing hardness. In comparison of bioavailability parameters after oral administration of Cefa-PG PEO matrix tablets and general Cefa-PG capsule in beagle dog, the sustained release PEO matrix tablets is more useful than a general dosage form. $AUC^{0-12}$ of the sustained release PEO matrix tablet and the general dosage form was 1.16 and 0.644 respectively.

  • PDF

폴리프로필렌 글리콜 하이드로겔의 가교도 및 고분자사슬 길이조절에 의한 약물방출특성 (Drug Release Characteristics from Chain-extended and Crosslinked Polypropylene Glycol Hydrogels)

  • 이승진
    • Journal of Pharmaceutical Investigation
    • /
    • 제24권4호
    • /
    • pp.251-256
    • /
    • 1994
  • Polypropylene glycol (M.W. 4000) was crosslinked and chain-extended by using triisocyanate and diisocyanate to synthesize rubbery and water swellable hydrogels. Model drugs, i.e., sodium salicylate and indomethacin were incorporated in the polymer matrices by swelling loading. The drug release rates of drugs could be regulated by varying the degrees of crosslinking and chain-extension. Whereas, no correlation was observed between the drug release profiles and the swelling behaviours of the matrices. The release of drugs from the matrices was considered to be governed by the mobility and mesh size of the polymer chains in the matrices.

  • PDF