• 제목/요약/키워드: relaxation times

검색결과 388건 처리시간 0.022초

InSe 단일층의 vacancy 결함 특성 연구

  • 이서윤
    • EDISON SW 활용 경진대회 논문집
    • /
    • 제6회(2017년)
    • /
    • pp.468-472
    • /
    • 2017
  • 2차원 InSe 단일층에 존재할 수 있는 vacancy defect인 In vacancy, Se vacancy의 원자구조 및 전자구조 특성을 제일원리계산을 이용해 살펴보았다. InSe $5{\times}5$ supercell을 이용하였으며 total energy를 구해 어떤 구조가 가장 안정한지 찾았다. Relax된 결함구조들을 clean InSe와 비교하여 어떤 변화가 있었는지 특징을 분석하였다. 이러한 intrinsic 결함들이 각각 어떤 구조로 relaxation되는지 살펴보고 clean InSe와 비교해보았다. 또한 각 결함구조의 density of states (DOS), projected density of states (PDOS)와 band structure를 clean InSe와 비교해봄으로써 defect state가 어떻게 나타나는지를 찾아보았다.

  • PDF

Characteristics of HTS SQUID-based Susceptometer

  • Timofeev, V.P;Kim, C.G;Shnyrkov, V.I
    • Journal of Magnetics
    • /
    • 제3권3호
    • /
    • pp.82-85
    • /
    • 1998
  • A portable HTS RF SQUID-based system, weighing less than 20 kg has been built for susceptometry applications in weak magnetic fields, It includes a YBCO sensor for measuring the axial magnetic field component with a resolution of about $7{\times}10^{-13} T/Hz^{1/2}.$ This is determined by the intrinsic magnetic noise in the quasi-white noise region. There is a relaxation for a sudden increase in field due to magnetic flux creep in HTS. In this instance the time did not exceed 3~5 minutes.

  • PDF

Quantum Beats in Recombination of Spin-correlated Radical Pairs

  • Yu. N. Molin
    • Bulletin of the Korean Chemical Society
    • /
    • 제20권1호
    • /
    • pp.7-15
    • /
    • 1999
  • The present paper is a review of the current studies of quantum beats in recombination of spin-correlated radical pairs in solutions as well as of future applications of quantum beats technique for studying these pairs. Examples are given of the use of this method for determining the hfi constants and relaxation times of short-lived radical ions, for finding the rate constants of the reactions of alkane radical cations and for estimating a fraction of singlet-correlated pairs in the pairs in the tracks of ionizing particles. The potentialities of this method, its advantages and limitations are discussed.

Effects of the Endothelium on the Contractile Responses to Norepinephrine in Isolated Proximal and Distal Coronary Artery of Pigs

  • Kim, Jong-Hoon;Jeon, Byeong-Hwa;Chang, Seok-Jong;Park, Hae-Kun
    • The Korean Journal of Physiology
    • /
    • 제27권1호
    • /
    • pp.27-35
    • /
    • 1993
  • Effects of the endothelium on the contractile responses to norepinephrine (NE) were investigated in isolated helical strips of the proximal and distal coronaries artery of pigs. The helical strips were immersed in Tris-buffered Tyrode's solution equilibrated with 100% $O_2$ at $35^{\circ}C$ and its isometric tension was measured. NE relaxed the strips precontracted with acetylcholine from both the proximal and distal coronary artery. NE-induced relaxation, which might be induced mainly by $\beta$-adrenoceptor function was dominant in the distal coronary arteries. NE-induced relaxation was converted to a contraction after $\beta$-adrenoceptor blockade with propranolol $(3{\times}10^{-6}M)$. ${\alpha}$-adrenoceptor-mediated contraction by NE was greater in the proximal coronary artery than the distal coronary artery. Quantitatively, ${\alpha}_1$-adrenoceptor mediated contraction by NE was greater than ${\alpha}_2$-adrenoceptor mediated contraction by NE in both arteries. NE-induced relaxation was decreased by rubbing of endothelium in both arteries. ${\alpha}_1-and\;{\alpha}_2$-adrenoceptor mediated contraction by NE were potentiated by rubbing of endothelium in both arteries. Pretreatment with methylene blue, an inhibitor of soluble guanylate cyclase, increased ${\alpha}_1-\;and\;{\alpha}_2$-adrenoceptor mediated contraction by NE in both arteries with endothelium. From the above results, we suggest that the effect of activation of $\alpha$-adrenoceptors by NE may be modulated by endothelium in the proximal and distal coronary arteries of pigs. This effect may be mediated via endothelium derived relaxing factor.

  • PDF

계층적 분할 기법과 완화된 국부 탐색 알고리즘을 이용한 효율적인 광역 배치 (Efficient Global Placement Using Hierarchical Partitioning Technique and Relaxation Based Local Search)

  • 성영태;허성우
    • 대한전자공학회논문지SD
    • /
    • 제42권12호
    • /
    • pp.61-70
    • /
    • 2005
  • 본 논문에서는 "middle-down" 접근법에 기반한 기존의 표준 셀 배치기인 하이브리드 배치기$^{[25]}$의 단점을 보완한 효율적인 광역배치 알고리즘을 제안한다. hMETIS(클러스터링을 이용한 다단계 하이퍼그래프 분할기법)에 사용된 기법과 RBLS(Relaxation Based Local Search) 기법의 적절한 조합을 통해 기존 하이브리드 배치기의 광역배치 기능을 향상시킨다. hMETIS를 통한 분할기법을 "top-down" 방식으로 적용하고, 각 단계에서 RBLS를 사용하여 광역배치를 점진적으로 개선해 나가는 제안된 기법은 초기 배치에 크게 영향을 받는 기존 방법의 문제점을 해결하고, 실행 속도를 개선하면서도 배치의 질을 떨어뜨리지 않는 효과적인 기법이다. 제안한 알고리즘을 통해 구현된 개선된 배치기는 기존의 하이브리드 배치기나 FengShui와 같은 우수한 툴과 비교할 때 뒤지지 않는 성능을 보인다. 특별히 기존의 하이브리드 배치기에 비해 실행 속도 면에서 평균 5배 정도의 개선을 보였고, 큰 회로에 대해선 배선길이도 줄어드는 향상된 결과를 보였다.

유지시간 효과를 고려한 12Cr 내열강의 열피로 및 저주기 피로 특성 (Thermal-Mechanical and Low Cycle Fatigue Characteristics of 12Cr Heat Resisting Steel with Hold Time Effects)

  • 하정수;고승기;옹장우
    • 한국자동차공학회논문집
    • /
    • 제3권1호
    • /
    • pp.1-12
    • /
    • 1995
  • Isothermal and thermal-mechanical fatigue characteristics of 12Cr heat resisting steel used for high temperature applications were investigated including hold time effects. Isothermal low cycle fatigue test at $600^{\circ}C$ and in-phase, out-of-phase thermal-mechanical fatigue test at 350 to $600^{\circ}C$ were conducted using smooth cylindrical hollow specimen under strain-control with total strain ranges from 0.006 to 0.015. Regardless of thermal-mechanical and isothermal fatigue tests, cyclic softening behavior was observed and much more pronounced in the thermal-mechanical fatigue tests with hold times due to the stress relaxation during the hold time. The phase difference between temperature and strain in thermal-mechanical fatigue tests resulted in significantly shorter fatigue life for out-of-phase compared to in-phase. The differences in fatigue lives were dependent upon the magnitudes of plastic strain ranges and mean stresses. During the hold time in the strain-controlled fatigue tests, the increase in the plastic strain range and the stress relaxation were observed. It appeared that the increase in plastic strain range per cycle and the introduction of creep damage made important contributions to the reduction of thermal-mechanical fatigue life with hold time, and the life reduction tendency was more remarkable in the in-phase than in the out-of-phase thermal-mechanical fatigue. Isothermal fatigue tests performed under the combination of fast and slow strain rates at $600^{\circ}C$ showed that the fatigue life decreased as the strain rate and frequency decreased,especially for the low strain ranges.

  • PDF

Investigation of entanglement dynamics of flexible polymer chains via comparison of dielectric and viscoelastic properties: a review of recent findings

  • Watanabe, H.
    • Korea-Australia Rheology Journal
    • /
    • 제13권4호
    • /
    • pp.205-217
    • /
    • 2001
  • This review article summarizes results of recent viscoelastic and dielectric studies for entangled cis-polyisoprene (PI) chains. The PI chains have the so-called type-A dipoles parallel along the chain backbone, and their slow viscoelastic and dielectric relaxation processes reflect the same global chain motion. However, this motion is differently averaged in the viscoelastic and dielectric properties, the former representing the isochronal orientational anisotropy of individual entanglement segments while the latter detecting the orientational correlation of the segments at two separate times (0 and t). On the basis of this difference, the viscoelastic and dielectric data of the entangled PI chains were compared to elucidate detailed features of the chain dynamics. Specifically, the molecular picture of dynamic tube dilation (DTD) incorporated in recent models was tested for linear and star PI chain. The comparison revealed that the DTD picture was valid for linear PI chains but failed for the star PI chains in the dominant part of the terminal relaxation. The failure for the star chains was related to the pre-requisite for the DTD process, rapid equilibration of successive entanglement segments through their constraint release (CR) motion: For the star chains, the dilated tube diameter expected in the terminal regime was considerably large because of a broad distribution of motional modes of the chains, so that the CR-equilibration required for DTD could not occur in time. The terminal relaxation of the star chain appeared to occur through the CR process before the expected DTD process was completed. The situation was different for the linear chain exhibiting narrowly distributed motional modes. The dilated tube expected for the linear chain was rather thin and the required CR-equilibration occurred in time, resulting in the success of the DTD picture. These detailed features of the chain dynamics was revealed only when the viscoelastic and dielectric properties were compared, demonstrating the importance of this comparison.

  • PDF

Magnetization of the stack of HTS tapes

  • Osipov, M.A.;Abin, D.A.;Pokrovskiy, S.V.;Mineev, N.A.;Rudnev, I.A.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제17권1호
    • /
    • pp.21-24
    • /
    • 2015
  • New results of dependence of magnetic field, trapped by a stack of HTS tapes, on amount of tapes in a stack are reported. Commercial GdBCO tape 12 mm width and without Cu layer was used for the research. Tape was divided in square pieces $12{\times}12mm^2$ from which stacks were formed. Filling factor of the tape was about 1.4%. Measurements were carried out for stacks with height from 5 to 250 pieces and at wide temperature range from liquid helium to liquid nitrogen. Both FC (field cooling) and ZFC (zero field cooling) cooling methods were used in the research. These two methods show matching results with good accuracy. As a result dependences of trapped magnetic flux on amount of tapes for different temperatures were received. Research shows, that with increasing height of the stack trapped magnetic field value reach saturation at about 60 tapes in a stack for low temperatures. From 60 to 100 tapes increase of magnet flux is only 5%. Thus increase amount of tapes in a stack is not profitable. Also investigation of trapped magnet field relaxation was carried out. Relaxation speed decreases with increasing amount of elements. It means that the higher the stack is, the longer trapped flux will be held in cause of the same temperature.

NaMgCl3 단결정 내의 23Na 원자핵에 대한 핵 자기 공명 연구 (Nuclear Magnetic Resonance Study of 23Na in NaMgCl3 Single Crystal)

  • 염태호
    • 한국자기학회지
    • /
    • 제25권6호
    • /
    • pp.185-188
    • /
    • 2015
  • 본 연구에서는 FT-NMR 분광기를 사용하여 $NaMgCl_3$ 단결정의 구성 원자인 $^{23}Na$ 원자핵에 대한 핵 자기 공명 실험을 하였다. 이로부터 $^{23}Na$ 원자핵이 모결정 내에서 입방정계 대칭성 내에 존재한다는 것을 알았고, 200 K~410 K 온도 범위에서 $^{23}Na$ 원자핵에 대한 스핀-격자 완화 시간 $T_1$을 온도 변화에 따라 계산하였다. 온도가 증가함에 따라서 $^{23}Na$ 원자핵의 $T_1$ 값이 점차적으로 감소하였다. 스핀-격자 완화율 $1/T_1$ 이 온도 T에 선형적으로 비례하였고, $^{23}Na$ 원자핵의 스핀-격자 완화 메커니즘을 $^{23}Na$ 원자핵 스핀과 단일 포논이 직접적으로 작용하는 직접과정(direct process)으로 설명하였다. 또한 $^{23}Na$ 원자핵의 활성화 에너지를 계산하여 $E_a=4.82J/mol$를 얻었다.

A semispherical SQUID magnetometer system using high sensitivity double relaxation oscillation SQUIDs for magnetoencephalographic measurements

  • Lee, Yong-Ho;Hyukchan Kwon;Kim, Jin-Mok;Kim, Kwoong;Park, Yong-Ki
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제5권1호
    • /
    • pp.21-26
    • /
    • 2003
  • We designed and constructed a multichannel superconducting quantum interference device (SQUID) magnetometer system to measure magnetic fields from the human brain. We used a new type of SQUID, the double relaxation oscillation SQUID (DROS). With high flux-to-voltage transfers of the DROS, about 10 times larger than the dc SQUIDs, simple flux-locked loop circuits could be used for SQUID operation. Also the large modulation voltage of the DROS, typically being 100 $mutextrm{V}$, enabled stable flux-locked loop operation against the thermal offset voltage drift of the preamplifier. The magnetometers were fabricated using the Nb/AlOx/Nb junction technology. The SQUID system consists of 37 signal magnetometers, distributed on a semispherical surface, and 11 reference channels were installed to pickup background noises. External feedback was used to eliminate the magnetic coupling with the adjacent channels. The liquid helium dewar has a capacity of 29 L and boil-off rate of about 4 L/d with the total 48 channel insert. The magnetometer system has an average noise level of 3 fT/√Hz at 100 Hz, inside a shielded loon, and was applied to measure auditory-evoked fields.