• 제목/요약/키워드: relative distance error rates

검색결과 7건 처리시간 0.02초

Statistical Assessment of Biosimilarity based on the Relative Distance between Follow-on Biologics in the (k + 1)-Arm Parallel Design

  • Kang, Seung-Ho;Shin, Wooyoung
    • Communications for Statistical Applications and Methods
    • /
    • 제22권6호
    • /
    • pp.605-613
    • /
    • 2015
  • A three-arm parallel design has been proposed to assess the biosimilarity between a biological product and a reference product using relative distance (Kang and Chow, 2013). The three-arm parallel design consists of two arms for the reference product and one arm for the biosimilar product. This paper extended the three-arm parallel design to a (k + 1)-arm parallel design composed of k (${\geq}3$) arms for the reference product and one arm for the biosimilar product. A new relative distance was defined based on Euclidean distance; consequently, a corresponding test procedure was developed based on asymptotic distribution. Type I error rates and powers were investigated both theoretically and empirically.

가우시안 잡음이 존재하는 무선채널에서 Chirp RTLS 시스템의 성능 특성에 관한 연구 (A Study on the Performance Characteristics of a Chirp RTLS over Wireless Channel with Gaussian Noise)

  • 강병권
    • 디지털융복합연구
    • /
    • 제11권7호
    • /
    • pp.201-207
    • /
    • 2013
  • 첩 신호는 그 양호한 코릴레이션 특성으로 인하여 전통적으로 레이더에서 주로 사용되어 왔으나, 최근에는 ISO/IEC 24730-5와 IEEE 802.15.4a 등에서 위치추적을 위한 표준규격으로 선정되어 여러 회사에서 이 방식을 구현하고 있다. 본 논문에서는 무선채널을 라이시안 채널로 모델링하고, 신호대 간섭 잡음비를 S/I = -30[dB], -20[dB], -10[dB]의 세가지 경우로 고려하고, 각 경우마다 라이시안 팩터 K=10과 K=20를 적용하여 성능을 시뮬레이션하여 평가하였다. 성능평가 결과, S/I = -30[dB]에서는 K=10에서 K=20으로 신호조건이 변화하면서 25%의 성능이 향상되었고, S/I = -20[dB]에서는 약 27%, S/I = -10[dB]에서는 약 50%의 성능이 향상되었다. 결과적으로 S/I=-20[dB] 미만인 경우 가시성분이 성능을 향상시킨다고 하더라도 신호의 전력은 필요한 최소값이 요구된다. 한편, 신호대 잡음비가 S/I=-20[dB] 이상으로 유지되는 경우 신호의 가시성분을 강화시킨다면 시스템의 성능을 크게 향상시킬 수 있다.

Optical-fiber Electronic Speckle Pattern Interferometry for Quantitative Measurement of Defects on Aluminum Liners in Composite Pressure Vessels

  • Kim, Seong Jong;Kang, Young June;Choi, Nak-Jung
    • Journal of the Optical Society of Korea
    • /
    • 제17권1호
    • /
    • pp.50-56
    • /
    • 2013
  • Optical-fiber electronic speckle pattern interferometry (ESPI) is a non-contact, non-destructive examination technique with the advantages of rapid measurement, high accuracy, and full-field measurement. The optical-fiber ESPI system used in this study was compact and portable with the advantages of easy set-up and signal acquisition. By suitably configuring the optical-fiber ESPI system, producing an image signal in a charge-coupled device camera, and periodically modulating beam phases, we obtained phase information from the speckle pattern using a four-step phase shifting algorithm. Moreover, we compared the actual defect size with that of interference fringes which appeared on a screen after calculating the pixel value according to the distance between the object and the CCD camera. Conventional methods of measuring defects are time-consuming and resource-intensive because the estimated values are relative. However, our simple method could quantitatively estimate the defect length by carrying out numerical analysis for obtaining values on the X-axis in a line profile. The results showed reliable values for average error rates and a decrease in the error rate with increasing defect length or pressure.

Verification of Mechanical Leaf Gap Error and VMAT Dose Distribution on Varian VitalBeamTM Linear Accelerator

  • Kim, Myeong Soo;Choi, Chang Heon;An, Hyun Joon;Son, Jae Man;Park, So-Yeon
    • 한국의학물리학회지:의학물리
    • /
    • 제29권2호
    • /
    • pp.66-72
    • /
    • 2018
  • The proper position of a multi-leaf collimator (MLC) is essential for the quality of intensity-modulated radiation therapy (IMRT) and volumetric modulated arc radiotherapy (VMAT) dose delivery. Task Group (TG) 142 provides a quality assurance (QA) procedure for MLC position. Our study investigated the QA validation of the mechanical leaf gap measurement and the maintenance procedure. Two $VitalBeam^{TM}$ systems were evaluated to validate the acceptance of an MLC position. The dosimetric leaf gaps (DLGs) were measured for 6 MV, 6 MVFFF, 10 MV, and 15 MV photon beams. A solid water phantom was irradiated using $10{\times}10cm^2$ field size at source-to-surface distance (SSD) of 90 cm and depth of 10 cm. The portal dose image prediction (PDIP) calculation was implemented on a treatment planning system (TPS) called $Eclipse^{TM}$. A total of 20 VMAT plans were used to confirm the accuracy of dose distribution measured by an electronic portal imaging device (EPID) and those predicted by VMAT plans. The measured leaf gaps were 0.30 mm and 0.35 mm for VitalBeam 1 and 2, respectively. The DLG values decreased by an average of 6.9% and 5.9% after mechanical MLC adjustment. Although the passing rates increased slightly, by 1.5% (relative) and 1.2% (absolute) in arc 1, the average passing rates were still within the good dose delivery level (>95%). Our study shows the existence of a mechanical leaf gap error caused by a degenerated MLC motor. This can be recovered by reinitialization of MLC position on the machine control panel. Consequently, the QA procedure should be performed regularly to protect the MLC system.

이동 보상과 분류 벡터 양자화기를 이용한 영상 부호화에 관한 연구 (Ⅱ: 하드웨어 실현) (A Study on the Interframe Image Coding Using Motion Compensated and Classified Vector Quantizer (Ⅱ : Hardware Implementation))

  • 전중남;신태민;최성남;박규태
    • 대한전자공학회논문지
    • /
    • 제27권3호
    • /
    • pp.21-30
    • /
    • 1990
  • 본 논문은 MC-CVQ(motion compensated and classified vector quantization) 알고리듬의 하드웨어 실현에 관한 것으로, $128{\times}128$화소로 구성된 흑백영상을 64Kbps채널로 1초에 약 10장의 화면을 전송할 수 있는 화면간 부호화장치의 제작에 대하여 설명하였다. 위의 조건하에서 보호화를 수행하기 위하여, 시스템을 MC부, CVQ부, 보호화부로 구분하여 마이크로프로그램 제어에 의한 멀티프로세서 구조로 구성하였다. 그리고 MC부와 CVQ부에서 최소 거리 오차를 효율적으로 계산하기 위하여 연산부에는 3~단 파이프라인 구조를 채택하였다. 시스템 제작 후 성능을 평가한 결과, 본 시스템의 화면전송율은 영상신호의 상대적 이동량에 따라 1초에 6~15장 정도임을 확인하였다.

  • PDF

초고속주행 하이퍼루프 포드의 정밀 위치측정 장치 구현 및 성능평가 (Implementation and Performance Evaluation of a Precision Localizing Device for Hyperloop Pods Driving at Ulta-High Speeds)

  • 옥민환;최수용;최재헌;이관섭
    • 한국정보전자통신기술학회논문지
    • /
    • 제13권5호
    • /
    • pp.443-451
    • /
    • 2020
  • 하이퍼루프는 튜브 내를 부상한 상태로 초고속주행하는 미래형 이동 시스템으로 제안되었다. 하이퍼루프에서 달리는 포드 차량은 선형 동기모터 상에서 주행하기에 위치측정이 근본적 중요성을 가진다. 1000km/h 이상의 속도로 주행하는 포드 차량의 가속과 감속에 정밀한 위치측정이 요구되며 또한 차량간 거리 유지를 위한 속도 조절에도 요구된다. 본 논문은 laser surface velocimeter를 개량하여 새로운 범위조건의 위치측정을 시도한다. 높은 정밀도로 초고속 이동체의 위치를 측정해야 하기에 지나가는 타일의 레이저 반사율 차이 검출로 변위를 계산하는 상대위치 측정장치를 구현하여 성능시험으로 평가하였다. 500km/h 미만의 포드 속도에서 cm 단위의 정밀도로 정확한 위치 측정을 보였으며, 500km/h 이상의 포드 속도에서도 0.1% 미만의 매우 낮은 오차율로 위치측정 결과를 보여주었다. 향후 500km/h 이상에서의 오차율도 0에 수렴하도록 연구를 진행해야 한다.

투과 감마선 계측신호의 Cross correlation 기법 적용에 의한 다중상 유체의 유량측정 (The Flow-rate Measurements in a Multi-phase Flow Pipeline by Using a Clamp-on Sealed Radioisotope Cross Correlation Flowmeter)

  • 김진섭;김종범;김재호;이나영;정성희
    • Journal of Radiation Protection and Research
    • /
    • 제33권1호
    • /
    • pp.13-20
    • /
    • 2008
  • 석유 및 정유관련 산업에서 다중상(multi-phase flow) 유체의 배관 내 흐름은 일반적인 현상의 하나이다. 그러나 각각의 상에 대한 정확한 유량측정은 항상 정확한 결과획득을 얻는데 장애의 근원으로 작용하였다. 일반 상업용 유량계는 일정 이상의 기포가 포함된 유체 흐름의 경우 유량계측에 상당한 오차를 유발한다. 본 연구에서는 ${\gamma}$-ray attenuation 기법을 이용하여 clamp-on 타입으로 배관 외부에서 다중상 유체흐름의 유량 측정을 수행하였다. 사용된 밀봉 감마선원으로는 $^{137}Cs$ 20 mCi와 17 mCi 두 개의 동위원소를 사용하였으며, 감마선 검출기로는 $2"{\times}2"$ NaI(Tl) 섬광계수관을 이용하였다. 방사선 검출기로부터 데이터를 수집하고 각각의 데이터에 대해 푸리에 변환과 필터링을 통해 노이즈를 최소화하였다. 복원된 신호에 대해 상호상관함수(cross correlation function)를 적용하여 두 검출기 사이의 통과시간(transit time)을 측정함으로써 유량을 산정하였다. 배관 내 기포함량 측정을 통해 유량을 보정해줌으로써 측정유량의 정확도를 높였다. 두 선원간의 거리가 4D(D; inner diameter) 그리고 본 실험의 측정조건(N/S: $0.12{\sim}0.15$, sampling time ${\Delta}\;t$: 4msec) 하에서 기포량(단면적 대비 $6.1\;%{\sim}9.2\;%$) 보정을 통해 산정된 유량은 계측오차가 실제 평균유량 대비 1.7 % 이하인 정확도를 보였다. 또한 두 밀봉 감마선원 간의 거리가 가까울수록 통과시간 측정에 정확도가 향상되므로 보다 정확한 유량측정이 가능하였다. 본 연구를 통해 다중상 혼합유체의 유량을 밀봉감마선원과 상호상관 기법으로 이용하여 계측할 수 있음을 확인하였다. 방사성동위원소의 선택 및 계측시스템의 최적화 조건 등에 대한 추가연구가 수행된다면 석유화학 산업과 같은 장치산업의 유지관리 측면에 경제적으로 크게 기여할 수 있을 것으로 판단된다.