• Title/Summary/Keyword: relative angle

Search Result 806, Processing Time 0.027 seconds

Effect of Load Condition on Turning Performance of a VLCC in Adverse Weather Conditions

  • Zaky, Mochammad;Yasukawa, Hironori
    • Journal of Advanced Research in Ocean Engineering
    • /
    • v.4 no.2
    • /
    • pp.53-65
    • /
    • 2018
  • The load condition significantly influences ship maneuverability in calm water. In this research, the effect of the load condition on turning performance of a very large crude oil carrier (VLCC) sailing in adverse weather conditions is investigated by an MMG-based maneuvering simulation method. The relative drift direction of the ship in turning to the wave direction is $20^{\circ}-30^{\circ}$ in ballast load condition (NB) and full load condition (DF) with a rudder angle $35^{\circ}$ and almost constant for any wind (wave) directions. The drifting displacement in turning under NB becomes larger than that under DF at the same environmental condition. Advance $A_d$ and tactical diameter $D_t$ become significantly small with an increasing Beaufort scale in head wind and waves when approaching, although $A_d$ and $D_t$ are almost constant in following wind and waves. In beam wind and waves, the tendency depends on the plus and minus of the rudder angle.

The Development of Turbo-Fan Blade for KTX (KTX용 터보팬 블레이드 개발)

  • Jang, Young-Min;Kwon, O-Woon;Kim, Sung-Joon
    • Journal of Industrial Technology
    • /
    • v.29 no.B
    • /
    • pp.41-45
    • /
    • 2009
  • The new cooling fan for various parts & equipments of KTX is developed and evaluated to improve fan performance and durability. The characteristic curve of the developed fan is obtained according to KSB 6311 of performance test regulation. 70 degree of the installation angle of blade makes the fan to produce a maximum flow rate. This angle is found out through trial-error and is confirmed through the verification test. In order to improve the blade strength, the blade is produced by a draw forming. The adoption of AL50 reduces a fan weight by 6 kg. The new blade makes a static pressure 170 (mmAq), a discharge rate $140(m^3/min)$, a rotational speed 2886 (rpm) at the power 10 kw. which results 54% of the static pressure improvement relative to the original blade.

  • PDF

Tracking Error Extraction Algorithm in Monopulse Active Homing Radar System

  • Kwon, Jun-Beom;Kim, Do-Hyun;Kim, Lee-Han;Byun, Young-Jin
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.158.5-158
    • /
    • 2001
  • Monopulse active homing radar requires velocity and angle information of target to track fast moving target. Target velocity can be estimated by measuring the frequency shift between transmitted and received frequencies. Angle information is obtained by measuring boresight error. Measurement of doppler frequency component in received signal is done through FFT analysis and interpolation algorithm for fine tuning. Boresight errors in azimuth and elevation axes are proportional to the power of each difference channel relative to sum channel. The target signal power in difference channel is estimated more precisely by measuring the power of FFT result cell of maximum ...

  • PDF

The Effects of Chlorination on the Friction Properties of SBR (염소화 반응조건이 SBR의 표면마찰 특성에 미치는 영향)

  • Park, Cha-Cheol;Kim, Ho-Jung
    • Fashion & Textile Research Journal
    • /
    • v.10 no.1
    • /
    • pp.101-105
    • /
    • 2008
  • This study was concerned with the influence of reaction conditions on the surface friction properties of Syrene-Butadiene Rubber(SBR) sheet when it was chlorinated by chemical treatment method using the sodium hypochlorite and sulfuric acid. The results of this study were as follows. SEM photographs of chlorinated SBR surface showed uneven etching caused by the chlorination. In the FTIR spectra, the intensity of C=C peak of SBR was decreased with increasing the concentration of sodium hypochlorite. Otherwise there was no trace of C=C peak in spectrum of SBR treated with 5 wt% NaOCl with pH 0.1 for 90 seconds. EDX spectra showed that relative content of chlorine of SBR was increased with increasing the amount of sodium hypochlorite, and also affected with pH condition of acid solution. Friction angle and friction coefficient of SBR were influenced with concentration of sodium hypochlorite, but were not with pH condition of acid solution.

Anti Roll Bar Force Computation Algorithm for Real Time Multibody Vehicle Dynamics (실시간 차량 동역학 해석을 위한 안티 롤 바 힘 계산 알고리듬)

  • Kim, Sung-Soo;Jeong, Wan-Hee;Ha, Kyoung-Nam
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.2
    • /
    • pp.170-176
    • /
    • 2008
  • Anti roll bar model for real time multibody vehicle dynamics model has been proposed using kinematic constraint. Anti roll bar have been modeled by kinematic relationship, and mass properties are neglected. Relative angle of torsion bar spring is computed by constraint about drop-link using Newton-Raphson iteration, and then the torque of torsion bar spring can be computed with the angle and torsion spring stiffness. Finally anti roll bar force acting on both knuckle can be calculated. To validate the proposed method, half car simulations of McPherson strut suspension and full car simulations are also carried out comparing with the ADAMS vehicle model with anti roll bar. CPU times are also measured to see the real-time capabilities of the proposed method.

Nonlinear Input-Output Feedback Linearizing Control of a Single Machine Infinite Bus Power System (1기 무한모선 전력계통의 배선형 입출력 되먹임 선형화 제어)

  • Kim, Dong-Gun;Kim, Seok-Kyoon;Yoon, Tae-Woong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.1
    • /
    • pp.1-5
    • /
    • 2007
  • Many nonlinear controllers for the power system are based on nonlinear models involving the power angle as an element of the state, and therefore the reference value for the power angle is needed. As this reference value is not generally available, it is difficult to apply such nonlinear control methods in practice. To deal with this problem, we present an input-output feedback linearizing control scheme by selecting the output as a combination of the squared voltage and the relative frequency. It is shown that the internal dynamics are locally stable with controllable damping, and that the frequency remains bounded for all time. Simulations illustrate the effectiveness of the proposed method.

Orientational deformation of ferroelectric liquid crystal molecules by bending performance of plastic substrate

  • Son, Ock-Soo;Lee, Ji-Hoon;Jang, Chi-Woong;Lim, Tong-Kun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.338-341
    • /
    • 2005
  • We have examined the aspects of the orientational ordering deformation of ferroelectric liquid crystal during bending performance of plastic substrate by analyzing the polarizing optical microscope texture and the birefringence of the cell. Striped texture becomes more prominent as the radius of curvature of substrate gets smaller. The optic axis of the adjacent stripes domain was not same and the relative angle between them becomes larger as the radius of curvature gets smaller. Especially, the optic axis rotation angle of one domain was lager than the other and the liquid crystal molecules in each domain became more coherent. In addition, the birefringence data with obliquely incident light shows the polar direction shift of liquid crystal molecule by bending performance.

  • PDF

Harmonics Analysis of Magnetostriction in 3% SiFe

  • Kim, C.G.;Ahn, S.J.;Jeong, M.H.;Kim, H.C.;Cha, S.Y.;Chang, S.K.
    • Journal of Magnetics
    • /
    • v.3 no.4
    • /
    • pp.120-122
    • /
    • 1998
  • The higher order harmonic components of magnetostriction during ac magnetization in 3% SiFe are measured as a function of the magnetizing angle respect to [001] axis using a constructed laser interferometry. The magnetostriction with magnetizing angle from [001] axis agrees ith the calculation based on domain reorientation. The relative amplitudes of odd and even harmonics respectively for magnetic induction and magnetostriction decrease with the order of harmonics, accompanying the contraction of the amplitudes. The contraction of harmonics order of magnetostriction harmonics is shown to be the even number times of that of magnetic induction.

  • PDF

Characterization of Surface Modified Polysulfone Membranes with Various Fluorine Chemicals

  • Lee, Choong-Sub;Rhim, Ji-Won
    • Korean Membrane Journal
    • /
    • v.4 no.1
    • /
    • pp.20-24
    • /
    • 2002
  • The surface of polysulfone membranes has been modified using the fluorine chemicals, ITFE (2-iodo-1,1,1-trifluoro-ethane F.W.=209.94) and PFPI (1H,1H-pentafluoro-n-propyl iodide F.W.=259.95), and PFI (1H,1H,2H,2H-perfluorohexyl iodide, F.W.=373.99) based on Friedel-Crafts reaction mechanism with varying reaction temperatures, reaction time, and catalysis types. The resulting membranes were characterized through mainly the contact angle measurement and pure water permeability. The smaller reactant shows the larger contact angles. FeBr$_3$ catalyst is more effective than AlCl$_3$. Typically, the PS film treated with ITFE at $25^{\circ}C$ under FeBr$_3$ catalyst showed the contact angle 78.5$^{\circ}C$ which indicated 10% over the value of unreacted PS films. More than 50% of pure water flux 8.0 g/$m^2$hr, reduced at reaction time 10 min relative to the original flux, 3.49 g/$m^2$hr.

Biomechanical Assessment of Lifting Chair with Hip-up Function (힙업기능이 적용된 기립보조의자의 생체역학적 평가)

  • Bae, Ju-Hwan;Moon, In-Huyk
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.3
    • /
    • pp.191-197
    • /
    • 2011
  • Lifting chair is a typical assistive product to aid for standing up and sitting down for persons with disability. It is particularly useful for the elderly persons whose muscular system is weakened by degenerative joint disease. This paper describes biomechanical assessments of lifting chair with hip-up function. In experiments we measured 3D motion and electromyographic(EMG) signal on the femoral muscle when subject performs the standing motion on the predetermined seat height. Based on assessment of the standing motion, we select the hip-up angle as 15 degrees to cover the relative femoral angle when EMG peak value is appeared. Using an implemented prototype lifting chair with hip-up function we perform standing experiments with five subjects. The experimental results show that the lifting and hip-up functions are effective to assist for standing up motion with less muscle force.